GasSense NDIR User Manual

Similar documents
Datasheet: K-30 ASCII Sensor

FTC130 Transmitter. Operating Manual

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

MANUAL KPS Pressure Control Valve

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

SEC Signature DIR Process Monitor

O3 3E 1 F Gas Sensor Module

Sensoric 4-20 ma Transmitter Board Operation Manual

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Operating Instructions Temperature Measuring System MF420-5T-100

CSA Sample Draw Aspirator Adapter Operator s Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Technical Data Sheet MF010-O-LC

The Univentor 1250 Anaesthesia Unit

AUTO PUMP STATUS CENTER

Transmitter CS 21 Operation Manual

Columbus Instruments

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Instruction and Maintenance Manual

Overview. Front Panel: Keypad and Display

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

SonoMeter 30 Energy Meters

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

Transmitter CS 21 Operation Manual

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Model PDT Dewpoint Transmitter

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

PRELIMINARY DATASHEET

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Coriolis Mass Flow Meter

Precision pressure sensor Basic version Model CPT6020

Additel 761 Automated Pressure Calibrators Selection Guide

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

COSMO INSTRUMENTS CO., LTD.

Additel 761 Automated Pressure Calibrators Selection Guide

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

RGC-IR Remote Gas Calibrator for IR400

Additel 761 Automated Pressure Calibrators

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Additel 761 Automated Pressure Calibrators

ASDX Series Silicon Pressure Sensors

BUBBLER CONTROL SYSTEM

[Instruments for vacuum measurement, checking and adjustment] 3

BI-680 Online Dissolved Oxygen Controller Instruction Manual

deltaflowc deltaflowc Venturi or Probe

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

BUBBLER CONTROL SYSTEM

TH-1800-T TRX-700-CNG Converter

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

In Vivo Scientific, LLC INSTRUCTION MANUAL

RK-IR Sample Draw Aspirator Adapter Operator s Manual

HLM-2000-TX Gas Transmitter User Manual

DPC-30 DPC-100. Reference Manual

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

C-Flow Coriolis Mass Flow Meters

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

AMS 6916 Board mount pressure sensor with ratiometric analog output

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

GAS FUEL VALVE FORM AGV5 OM 8-03

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instruction and Maintenance Manual

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

Pneumatic high-pressure controller Model CPC7000

BUYER S GUIDE AQUAlogger 530WTD

Additel 761 Automated Pressure Calibrators

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

RK LEL Sample Draw Aspirator Adapter Operator s Manual

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Alphasense Application Note AAN NDIR: Gas Concentration Calculation Overview

M iniature Amplified Pressure Sensors

Electronic gas volume corrector model DGVC-04

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Model 601CV. Mass Flow Controller. Product Features:

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

AMS 2710 PCB pressure sensor module with V output

HTD series digital differential pressure sensors

INSTALLATION & MAINTENANCE INSTRUCTIONS

HumiSys HF High Flow RH Generator

Operating Instructions Part No

IRceL Operating Instructions

Electro-Pneumatic Converter YT-940 SERIES

RG2 Gripper Datasheet Version 1.6

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

FAS-W. Features. Applications. Automatic condensation hygrometer

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

BUYER S GUIDE AQUAlogger 520

Control units. Installation and operating instructions Series: DP-Control

Transcription:

INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION PROCEDURE... 10 7. MAINTENANCE... 11 8. WARRANTY AND LIMITATIONS OF LIABILITY... 11

1. OVERVIEW The GasSense NDIR gas sensor, with integrated transmitter, is an innovative measurement module for the detection of CO2, CO, N2O, CH4 or related hydrocarbons. The sensor can be easily integrated as an OEM component into controls, measurement systems and monitoring instruments. The sensor uses dual channel Non-Dispersive Infrared Detection (NDIR) and detects the net increase or decrease of light that occurs at the wavelength where absorption of the detecting gas takes place. The light intensity is then correlated to gas concentrations. To ensure a reliable and stable measurement, the module is temperature compensated. The gas cell has been designed using non-sequential ray tracing techniques in order to ensure the best compromise between accuracy and sensor dimensions. Additionally, a dedicated rugged gas sensor cell option is available to minimise corrosive effects in harsh industrial environments, like biogas applications. The GasSense electronic board features a native wireless module managed with Ultra Low Power techniques, a fault diagnostics system and a power module suited to manage charging and energy recovery systems. The GasSense sensor can be used with a pneumatic pump or can simply work by natural diffusion mode.

2. TECHNICAL DATA Detection Method Dual channel Non-Dispersive Infrared (NDIR) Dimensions Depending on the sensor model (type of gas and range, see 5.1) Source drive frequency Data refresh rate Response time (t90) Warm up time Operating conditions 1 to 2Hz 5 to 10 seconds 15 to 40s @ 20 C ambient and @ 1 l/min <30s @ 20 C operational, <30 minutes @ 20 C (full spec) Temperature 0 C to 50 C linear compensated Humidity Pressure 0-95% RH (non-condensing) not compensated 800-1150hPa not compensated Pressure dependency +1.5% reading per kpa deviation from normal pressure of 100kPa Storage temperature -40 C to 85 C Analog Output 4-20mA, 0-5V Analog Input Digital I/O 2 available for third-party devices 4OUT: Open collector, ground referred, protected; 4 IN: 0-5 V protected up to 24Vdc On module connector Mating connector Power Supply: SL3.5/2/180G3.2 BL3.5/2 Analog I/O: SL3.5/2/180G3.2 BL3.5/6 Connector type Pump: SL3.5/2/180G3.2 BL3.5/2 Digital I/O: 215307-5 826656-5 Analog Out (0-5V): 8-215464-6 8-215079-6 Power Supply & UART TTL level (0-5V) (J20): 7-215464-6 7-215079-6 Pipe connections For tube with diameter ø4 / ø2.5mm Interface connection UART (TTL level 0-5V), baud rate: 9600 (default) - 19200-38400 MTBF Power supply Power consumption > 5 years 9-24V DC, reverse protected max 90mA @ 9VDC, excluding pump power absorption

3. SPECIFICATIONS Gas Measurement Range* Accuracy** Zero Res. (ppm) Full Scale Res. Zero Repeatability (ppm) Full Scale Repeatability (ppm) GasSense Model 0-1000ppm ±1% FS 1 1% FS ±5 ±10 A-7 0-2000ppm ±1% FS 1 1% FS ±10 ±25 A-8 0-5000ppm ±1% FS 1 2% FS ±10 ±50 A-1 CO2 0-1% ±2% FS 1 2% FS ±25 ±200 A-9 0-5% ±2% FS 1 2% FS ±25 ±250 A-6 0-10% ±2% FS 1 2% FS ±25 ±250 A-2 0-25% ±2% FS 1 1% FS ±50 ±500 A-3 0-100% ±1% FS 1 1% FS ±1000 ±5000 A-4 CO 0-2000ppm ±1% FS 5 1% FS ±10 ±70 B-1 0-2000ppm ±4% FS 5 4% FS ±15 ±100 C-1 CH4 0-100% LEL ±2% FS 15 4% FS ±50 ±500 C-2 0-100% vol. biogas*** ±2% FS 500 2% FS ±1000 ±5000 C-3I 0-100% vol. ±2% FS 300 2% FS ±500 ±3000 C-4 HC 0-2000ppm ±4% FS 5 4% FS ±15 ±100 D-1 0-100% LEL ±2% FS 15 4% FS ±50 ±500 D-2 N2O 0-2000ppm ±1% FS 1 1% FS ±10 ±20 F-1 * Other measurement ranges available on request ** Stated accuracy excludes calibration gas tolerance of ± 1% *** Corrosion-proof sensor cell and housing

4. PRODUCT DESCRIPTION The GasSense combines an electronic circuit board and a measurement gas chamber, connected to the board with two connectors. The dimensions of the gas chamber vary depending upon the model and two input and output connectors are provided. The GasSense is provided with firmware to manage the measuring cycle (gas inlet through pneumatic pump and gas concentration calculation), temperature compensation and communication. The working frequency and other parameters can be modified according to customer requirements. Please contact Euro-Gas for details. 4.1 Mechanical details The GasSense transmitter board, common to all models, is 56mm x 48mm wide. Three holes (shown in black in the drawing below) allow the board to be secured according to customer requirements:

GasSense NDIR sensor dimensions vary depending on the sensor model (appropriate to the type of gas and range required): Models: A-1, A-2, A-4, A-6, A-7, A-8, A-9, C-2, D-2 Models: B-1, C-1, D-1, F-1 Model: A-3

4.2 Piping The GasSense NDIR sensor has two connections available for pipe connections. The sensor performs best if the gas flows in a controlled direction inside the gas cell. Looking at the GasSense sensor from the top, with the WEIDMULLER (orange) connectors positioned at the bottom, the connector on the right side is the gas inlet and the connector on the left side is the gas outlet. The following diagram shows the gas inlet/outlet position in relation to the gas cell and orange connectors. Connectors vary according to the GasSense sensor model. 4.3 Connections The diagram below shows the top layer of the GasSense board and the board terminals. Terminals vary depending on the version and some may not be mounted or functioning.

4.3 Connections (continued) Connector J4 J6 J7 J8 J9 J10 J13 J14 J15 J17 J18 Function Jumper for power supply selection SPI bus interface SPI bus interface Source Detector Digital I/O Pin1, 3, 5, 7: IN (0-5V protected up to 24Vdc) Pin2, 4, 6, 8: OUT (Open collector, ground referred, protected) Pin9, 10: gnd Power supply. Solar panel input Pin1: plus (+); Pin2: gnd Power supply. Battery input Pin1: pack thermistor; Pin2: gnd; Pin3: plus (+) Power supply. 9-24V DC Pin1: plus (+); Pin2: gnd Analog output (4-20mA; 0-5V), two analog inputs (4-20mA or 0-5V) Pin1: 0-5V; Pin2: 4-20mA; Pin3: gnd; Pin4: analog input (+); Pin5: analog input (+); Pin6: gnd Pneumatic pump power supply Pin1: plus(+); Pin2: minus (-)

4.3 Connections (continued) The diagram below shows the bottom layer of the GasSense board and highlights the available connectors: Connector J5 J16 J20 Function UART 9600-115200 Baud ( 0-3V TTL level) Pin1: Tx Pin2; Pin4: gnd Pin3: Rx Analog output (0-5V) Pin10: 0-5V; Pin9: gnd Power supply 0-24V DC; UART TTL level (0-5V) required 0-5V external power supply Pin1: ext UART supply; Pin2: 9-24VDC; Pin3: Tx UART; Pin4: Rx UART; Pin5: nc; Pin6: gnd

4.3 Connections (continued) Notes: The DC power input is protected against reverse, over-voltage (up to 33V) and short circuit (max absorption 250mA). The external pump power supply is by default 3V (5V optional) and the max power absorption is 160mA. J17 connector: there are two analogue input 4-20mA (0-5V optional). Digital input are protected against over-voltage (up to 35V) and short circuit (max absorption 250mA). Digital output are protected against short circuit (max absorption 160mA). Use rechargeable batteries (Ion-Li 7.4V with NTC thermistore). Tyco connectors are available on the board bottom layer. They are used for board power supply (9-24V protected against reverse, over-voltage (up to 33V) and short circuit (max absorption 250mA), UART TTL level (0-5V) serial bus, 5V DC power supply for the UART, analogue output 0-5V. 5. INSTALLATION The GasSense sensor is factory calibrated and ready for use directly after power up. There are 3 alternative ways to power supply the sensor board: 1. Using the J15 terminal for DC voltage input 2. Using the J14 terminal for battery input 3. Using the J20 terminal for DC voltage input 6. CALIBRATION PROCEDURE Please refer to the Calibration Procedure document. Please discuss your application with us for advice on calibration.

7. MAINTENANCE The GasSense sensor is maintenance free under normal conditions. The sensor is a safety device and must only be repaired by the manufacturer. Do not modify the sensor and do not reconstruct it. It might otherwise no longer measure the gas concentration reliably. 8. WARRANTY AND LIMITATIONS OF LIABILITY Euro-Gas grants a warranty for this device for a period of 12 months from commissioning, documented by a commissioning report. Within this warranty period, we will at our discretion repair or replace the device free of charge if found to be defective as to workmanship or material. The warranty excludes: damages attributable to improper use, normal wear and defects that have only a negligible influence on the device's value or suitability for use. Liability for the functioning of the sensor shall pass at all events to the owner or operator if the sensor is improperly maintained or repaired or if it is used other than for its intended purpose. Euro-Gas accepts no liability for damage caused by failure to observe the above information. The warranty expires in the event that work is carried out by agents we have not authorised or if parts are used other than original spare parts. Claims under the warranty may be made in all countries where this device is sold by authorised dealers. In the event of any claim under the warranty, please return the device to us. The buyer shall bear the costs of transportation and the risk while the device is in transit. The execution of work under the warranty does not affect the warranty period in any way. The above information does not extend the conditions of warranty and liability contained in the Terms and Conditions of Sale and Delivery of Euro-Gas Management Services Limited. Any sensor can potentially fail to meet specification without warning. Euro-Gas makes every effort to ensure reliability of all sensors but where life safety is a performance requirement of the product and, where practical, Euro-Gas recommends that all gas sensors and instruments using sensors are checked for response to gas before use. The data contained in this document is believed to be accurate and reliable. The data given is for guidance only. Euro-Gas Management Services Ltd accepts no liability for any consequential losses, injury or damage resulting from the use of this datasheet or the information contained in it. Customers should test the sensors under their own conditions to ensure that the sensors are suitable for their own requirements and in accordance with the plans and circumstances of the specific project and any standards/regulations pertaining to the country in which the sensors will be utilised. Performance characteristics on this data sheet outline the performance of newly supplied sensors. Output signal can drift below the lower limit over time. This datasheet is not intended to form the basis of a contract and in the interest of product improvement, Euro-Gas reserves the right to alter design features and specifications without notice. 03/17