SPECIALIST GAS VALVES AND FITTINGS

Similar documents
CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

// ADapters GUIDelines

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

RESIDENTIAL REGULATORS

HERZ-Motorised flow controler

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

OPERATING INSTRUCTIONS

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

TECHNICAL DATA. Trimpac 244a. September 16, 2013

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

Continental Industries TRANSITION FITTINGS or FAX Visit

INSERT FITTINGS INSERT FITTINGS

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Pressure ranges and accuracy classes for outlet pressure and safety devices

Continental Industries STEEL SERVICE TEES or FAX Visit

VERTICAL BLADDER TANK

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Simple to install connection fails. The Talbot Pushfit fitting is pressure rated PN 16.

screw fittings - nickel plated brass series SC

TECHNICAL DATA. Trimpac 256a. October 31, 2013

How Do I Install My Garden Master Bucket Garden?

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL Pressure Relief Device LPT

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Installation and commissioning instructions 255 series and 256 series

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Self-operated Pressure Regulators for special applications

SECTION 2 RING MOUNT

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Industrial Products Catalog Tank Valves

HORIZONTAL BLADDER TANK

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

DS06D,G Dial Set Pressure Regulating Valve

12S 1st Stage. -Maintenance Procedure-

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Installation and Maintenance Manual. Compact Medical Gas Outlets

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957

Pneumatic valve islands

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

MyControl Bathing System Signature Series

RegO Adapters, Connector, & Fittings

differential pressure regulating valve - threaded

FITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel)

Horizontal Bladder Tanks

13kW Patio Heater. Assembly & User Instructions

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Type 4708 Supply Pressure Regulator

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Water Safety Shut-off Valve HON 790

Materials : Brass body dezincification-resistant up to DN1 1/4

Pneumatic spool valve islands

Vertical Bladder Tanks

Pressure Dump Valve Service Kit for Series 2300 Units

Underground irrigation

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

FIREFIGHTING EQUIPMENT

SIMPLAIR PIPING TOOL. JXT Company

MINITHERM THE FEATHERWEIGHT WELDING AND HEATING TORCH

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

Spare parts list ( ) Spare parts list HD 1.8/13 C Ed

GM Series Dual-Block Multi-Function Gas Control Valves

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

SIT Group 710 MINISIT MULTI-FUNCTIONAL GAS CONTROL THERMOELECTRIC FLAME SUPERVISION DEVICE PRESSURE REGULATOR TEMPERATURE CONTROL PIN 0085AQ0287

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

A rising main is a system of pipe work and valves that enables water to be delivered for fire fighting purposes to all floors in buildings over 18

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

SPECIFICATIONS ATTENTION

PRESSURE REGULATOR LBM SERIES

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

General Performance Data Hose Ref Minimum Bend. Safety Pressure at 20 C (BAR) Working Pressure at. Flow Rate at 3 bar (lit/min) Working Pressure

Gas Pressure Regulator HON 300

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue

INSTALLATION GUIDELINES

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Model MTB-ASME Vertical Bladder Tanks

Transcription:

SPECIALIST GAS VALVES AND FITTINGS 0

HISTORY 1830 1900 1987 1997 1998 2007 2009 Creation of Chuchu Decayeux Chuchu Decayeux manufactures and creates gas lighting systems Chuchu Decayeux begins to specialize on the gas markets Abandonment of the other ranges Development of new products in collaboration with the technical departments of Gaz de France Creation of the export department Factory moving in premises adapted to its industrial ambitions Chuchu Decayeux is winner of the innovation competition at the Expogaz fair for its PE Clip connection system The VIGIGAZ concept brings new perspectives in terms of active security ACTIVITY Valves and fittings for distribution networks In constant dialogue with our clients, we intervene in the definition, design and production of fittings for all types of gas connections. We discover innovative and high performance solutions, complying with the imposed market specifications. Quarter turn ball valves complying with current international and French national standards, ND 12 to 50mm, with all types of connections and various types of locking devices and test points Fittings for brazing to copper pipe, welding to steel, or connecting to polyethylene pipe, inlet and outlet risers for all type of meter positions Conception and design of bespoke meter boxes Pre-fabricated gas risers Design, conception and manufacture of bespoke fittings 1

VALVES Automatic shut-off ball valve - ROAI Double male gas Version ½ 12 Brushed 0120-011 ½ 12 Chrome 0120-811 Maximal use pressure: 37 mbar For flexible fitting (Vissogaz) Valve way of assembly marked on the body by an arrow Shut-off valve double male flat washer ¾ 15 3815-922 1 20 3820-920 1 ¼ 25 3825-925 1 ½ 32 3832-928 2 40 3840-932 2 ¼ 50 3850-936 Temperature class: from -20 C to + 60 C Shut-off gas valve - inside of the buildings and outside in red emergency shut-off cabinets All gas distributed by network - Installation only above ground Security gas valve double male flat washer 2" 40 6840-040 2"1/4 50 6850-050 Shut-off gas valve inside of the buildings and outside in red emergency shut-off cabinets All gas distributed by network installation only above ground Rearmament by an enable person 2

SECUROC double male with sphero-conical junctions and fixation bracket Without pressure point ¾ 15 7915-061 1 ¼ 25 7925-062 1 ½ 32 7932-063 SECUROC double male with sphero-conical junctions and fixation bracket With pressure point ¾ 15 7915-076 1 ¼ 25 7925-077 1 ½ 32 7932-078 SECUROC for PE with sphero-conical junctions and fixation bracket With pressure point PE pipe 20 ¾ 15 7915-067 32 1 ¼ 25 7925-068 40 1 ½ 32 7932-069 40 1 ¼ 32/25 3225-073 3

Gas valve double male with sphero-conical junction and fixation bracket With locking screw - Without pressure point ¾ 15 4915-011 1" ¼ 25 4925-013 1" ½ 32 4932-015 G as valve for PE with sphero-conical junction and fixation bracket With locking screw - Without pressure point PE pipe With cranck 20 ¾ " 15 4915-236 32 ¾ " 25/15 4915-232 32 1" ¼ 25 4925-234 40 1" ¼ 32/25 3225-230 40 1" ½ 32 4932-244 G as valve double male with sphero-conical junction and fixation bracket Without pressure point ¾ " 15 8915-088 1" ¼ 25 8925-089 1" ½ 32 8932-090 4

G as valve for PE with sphero-conical junction and fixation bracket Without pressure point PE pipe 20 ¾ " 15 8915-294 32 ¾ " 25/15 8915-232 32 1" ¼ 25 8925-295 40 1" ½ 32 8932-296 40 1" ¼ 32/25 8225-200 Gas valve for PE and with copper pipe fitting Without locking screw and pressure point PE pipe Copper pipe 32 28 25 3826-070 40 35 32 3826-071 Connection PE inlet to weld on lead or braze on copper All gas Gas valve double fittings copper pipe Without locking screw and pressure point Copper pipe Copper pipe 28 28 3826-052 35 35 3826-054 54 54 3826-056 Connection with two fittings in copper pipe to weld on steel or braze on copper All gas 5

Meter valve Ds type flat seal With locking screw Male meter Fitting to type meter With square 6/20 6/20 20 G4 3765-090 10/32 10/32 32 G6/G10 3760-092 With handle 6/20 6/20 20 G4 3765-091 10/32 10/32 32 G6/G10 3760-093 25/50 25/50 50 G16 40/50 40/50 G25 3750-050 Temperature class from -20 C to +60 C Meter inlet and gas riser low pressure, only pressure above ground All gas C type gas valve for gas riser bottom 1" ¼ 25 3825-025 1" ½ 32 3832-028 2" ¼ 50 3850-036 Temperature class: from -20 C to +620 C Shut-off gas valve double male with sphero- conical junctions With locking screw Double male meter With square ¾ 15 3915-020 1 20 3920-001 1 ¼ 25 3925-022 1 ½ 32 3932-025 With crank ¾ 15 3915-021 1 20 3920-000 1 ¼ 25 3925-023 1 ½ 32 3932-026 MPB gas riser all gas distributed by network (caliber 15) MPB gas riser 6

Gas valve for substitution shut-off ¼ turn flat washer With locking screw Double male Valve gas length With cranck 1 20/25S 80 3820-000 1 25S 95 3825-003 Delivered with aramid seal Shut-off gas valve for PE and with sphero-conical junctions With fixation bracket - With locking screw - With pressure PE pipe 20 3/4" 15 4915-036 32 3/4" 25/15 4915-132 32 1"1/4 25 4925-034 40 1"1/2 32 4932-044 40 1"1/4 32/25 3225-030 Model reserved to gas distributors in cabinet and elevation and buried regulation block All gas distributed by network Security gas valve for PE and with sphero-conical junction With fixation bracket - With pressure PE pipe 20 ¾ 15 8915-094 32 ¾ 25/15 8915-032 32 1" ¼ 25 8925-095 40 1" ½ 32 8932-096 40 1" ¼ 32/25 8225-000 Model reserved to gas distributors in cabinet and elevation and buried regulation block All gas 7

Gas valve double male with sphero-conical junctions with fixation bracket With locking screw With pressure point With cranck ¾ 15 4915-025 1 ¼ 25 4925-026 1 ½ 32 4932-027 Model reserved to gas distributors Security gas valve double male with sphero-conical junctions with fixation bracket With pressure point ¾ 15 8915-018 1 ¼ 25 8925-019 1 ½ 32 8932-020 Model reserved to gas distributors in cabinet and elevation and buried regulation block All gas 8

FITTINGS Straight fitting 2 pieces flat washer To braze on copper Nut gas Copper pipe Version Delivered in bulk Delivered in bags of 2 ½ 12 12 Brushed 0122-003 0122-063 ½ 14 12 Brushed 0122-004 0122-064 ½ 14 12 Chrome 0122-804 0122-864 ½ 16 12 Brushed 0122-005 0122-065 ½ 16 12 Chrome 0122-805 0122-865 ½ 16 12 Brushed 0122-006 0122-066 ¾ 16 15 Brushed 0794 - J03 0794 - J63 ¾ 18 15 Brushed 0794 - J04 0794 - J64 ¾ 20 15 Brushed 0794 - J02 0794 - J62 ¾ 22 15 Brushed 0794 - J05 0794 - J65 1 22 20 Brushed 0794 - J07 0794 - J67 1 28 20 Brushed 0794 - J12 0794 - J612 1 ¼ 28 25 Brushed 0794 - J09 0794 - J69 1 ¼ 32 25 Brushed 0794 - J10 0794 - J610 1 ½ 35 32 0794 - J13 0794 - J613 2 42 40 0794 - J16 0794 - J616 2 ¼ 54 50 0764 - J20 0794 - J620 Delivered with aramid seal complying with the NF E29-533 standard Respect imperatively the tightening torques ¾ 16 15 0794-003 ¾ 18 15 0794-004 ¾ 22 15 0794-005 1 22 20 0794-007 1 28 25S 0794-011 1 ¼ 28 25 0794-009 1 ½ 35 32 0794-013 2 42 40 0794-016 2 ¼ 54 50 0764-020 Delivered without seal 9

Straight fitting 2 pieces flat washer To weld on steel Steel pipe Delivered in bulk Delivered in bags of 2 ½ 21.3 (15-21) 12 0550 - J02 0550 - J62 ¾ 21.3 (15-21) 15 0550 - J04 0550 - J64 ¾ 26.9 (20-27) 15 0550 - J05 0550 - J65 1 26.9 (20-27) 20 0550 - J06 0550 - J66 1 ¼ 33.7 (26-34) 25 0550 - J08 0550 - J68 1 ½ 42.4 (33-42) 32 0550 - J11 0550 - J611 2 48.3 (40-49) 40 0550 - J13 0550 - J613 2 ¼ 60.3 (50-60) 50 0550 - J15 0550 - J615 Delivered with aramid seal complying with the NF E29-533 standard Respect imperatively the tightening torques ¾ 21.3 (15-21) 15 0550-004 ¾ 26.9 (20-27) 15 0550-005 1 26.9 (20-27) 20 0550-006 1 ¼ 33.7 (26-34) 25 0550-008 1 ½ 42.4 (33-42) 32 0550-011 2 48.3 (40-49) 40 0550-013 2 ¼ 60.3 (50-60) 50 0550 015 Delivered without seal Elbow 2 pieces flat washer Version delivered in bulk 1/2" 1/2" 12 Brushed 0124-003 1/2" 1/2" 12 Chrome 0124-803 Delivered with aramid seal complying with the NF 229-533 standard Respect imperatively the tightening torques Enables the link between the gas cooker and the flexible Elbow 2 pieces flat washer Conical 6.25% Male conical Version delivered in bulk 1/2" 1/2" 12 Brushed 0124-004 1/2" 1/2" 12 Chrome 0124-804 Delivered with aramid seal complying with the NF E29-533 standard Respect imperatively the tightening torques For build in wall arrival 10

Elbow 2 pieces flat washer To braze on copper Copper pipe Version delivered in bulk 1/2" 14 12 Brushed 0125-004 1/2" 16 12 Brushed 0125-006 Delivered with aramid seal complying with the NF E29-533 standard Respect imperatively the tightening torques Cap female flat washer Female gas Version 1/2" 14 Zamak 0126-001 1/2" 16 Brass 0126-002 1/2" 12 Brass with link 0126-003 3/4" 15 Brass 0126-004 Delivered with aramid seal version 1/2 Closing of the ROAI compulsory awaiting the gas cooking fitting Cap male flat washer Version 1/2" 12 Brushed 0786-003 Delivered with aramid seal Closing of the flexible compulsory awaiting the fitting to the gas cooker Straight fitting 2 pieces flat washer Conical 6.25% Male conical 6,25% Version delivered in bulk 1/2" 1/2" 12 Brushed 0130-012 1/2" 1/2" 12 Chrome 0130-812 Delivered with aramid seal complying with the NF E29-533 standard Respect imperatively the tightening torques For build in wall arrival 11

Straight fitting 1 piece flat washer Female gas Male metric Version delivered in bulk 1/2" M20x150 12 Brushed 0130-001 1/2" M20x150 12 Chrome 0130-801 Delivered with aramid seal complying with the NF E29-533 standard Respect imperatively the tightening torques Enables the link of the flexible Vissogaz butane propane with the ROAI Straight lengthen flat washer For PE PE pipe 1 ¼ 32 25 1035-025 1 ½ 40 32 1035-032 2 ¼ 63 50 1035-050 Fitting to valves with manoeuvre handle for PE pipings and valves with IDENTICAL calibers For reductions: please consult us Straight nipple flat washer To braze on copper Copper pipe Delivered in bulk ¾ 18 15 0855-062 1 22 20 0855-065 1 ¼ 28 25 0855-067 1 ½ 35 32 0855-070 2 42 40 0855-073 2 ¼ 54 50 0855-076 12

Straight nipple flat washer To weld on steel Steel pipe Delivered in bulk ¾ 21.3 (15-21) 15 0540-052 1 26.9 (20-27) 20 0540-054 1 ¼ 33.7 (26-34) 25 0540-056 1 ½ 42.4 (33-42) 32 0540-059 2 48.3 (40-49) 40 0540-061 2 ¼ 60.3 (50-60) 50 0540-063 Female cap flat washer 1 ¼ 25 0325-011 1 ½ 32 0332-013 2 40 0340-014 2 ¼ 50 0350-015 Straight fitting 2 pieces with sphero-conical junction To braze on copper Copper pipe Tightening torques Delivered in bulk Delivered in bags of 2 ¾ 12 15 40 Nm 0315-001 ¾ 16 15 40 Nm 0315-015 ¾ 18 15 40 Nm 0315-003 0315-063 1 22 20 0315-005 0315-065 1 ¼ 28 25 60 Nm 0315-007 0315-067 1 ½ 35 32 80 Nm 0315-009 0315-069 2 ¼ 54 50 140 Nm 0315-012 Complying with the NF E29-536 standard Respect imperatively the tightening torques thanks to a torque wrench 13

Straight reduction fitting 2 pieces with sphero-conical junction To braze on copper Copper pipe Tightening torque 1 ¼ 18 25 60 Nm 0326-021 1 ¼ 22 25 60 Nm 0326-023 Complying with the NF E29-536 standard Respect imperatively the tightening torques thanks to a torque wrench Straight fitting 2 pieces with sphero-conical junction To weld on steel Steel pipe Tightening torque Delivered in bulk Delivered in bags of 2 ¾ 21.3 (15-21) 15 40 Nm 0520-002 0520-062 1 26.9 (20-27) 20 0520-003 0520-063 1 ¼ 33.7 (26-34) 25 60 Nm 0520-004 0520-064 1 ½ 42.4 (33-42) 32 80 Nm 0520-006 0520-066 1 ½ 60.3 (50-60) 32/50 80 Nm 0520-008 2 ¼ 60.3 (50-60) 50 140 Nm 0520-010 Complying with the NF E29-536 standard Respect imperatively the tightening torques thanks to a torque wrench Straight reduction fitting 2 pieces with sphero-conical junction To weld on steel Steel pipe Tightening torque 1" ¼ 21,3 (15-21) 25/15 60 Nm 0520-021 Complying with the NF E29-536 standard Respect imperatively the tightening torques thanks to a torque wrench Straight fitting with sphero-conical junction For PE PE pipe Tightening torque ¾ 20 15 40 Nm 1030-013 1" ¼ 32 25 60 Nm 1030-014 1" ½ 40 32 80 Nm 1030-017 ¾ 32 25/15 40 Nm 1070-052 1" ¼ 20 15/25 40 Nm 1070-053 1" ¼ 40 32/25 80 Nm 1070-055 All gas distributed by network Complying with the EN 1555-3 Respect imperatively the tightening torques thanks to a torque wrench 14

Female cap 2 pieces with sphero-conical junction ¾ 15 0415-052 1 20 0415-054 1 ¼ 25 0415-055 1 ½ 32 0415-056 Pending cap Insulating fitting with sphero-conical junctions ¾ " ¾ " 15 2270-052 1" ¼ 1" ¼ 25 2270-054 1" ½ 1" ½ 32 2270-056 Model reserved to gas distributors in cabinet and regulation block (above ground) for metallic inlet All gas distributed by network Straight nipple with sphero-conical junction for regulators inlet To braze on copper To weld on steel Regulator Copper pipe Steel pipe B6 B10 B25 BCH30 From C40 to BCH120 ¾ 12 15 1560-002 ¾ 16 15 1560-015 ¾ 18 15 1560-054 ¾ 21.3 (15-21) 15 0570-052 1 ¼ 28 25 1560-057 1 ¼ 33.7 (26-34) 25 0570-054 1 ½ 35 32 1560-060 1 ½ 42.4 (33-42) 32 0570-056 2 ¼ 54 50 1560-063 2 ¼ 60.3 (50-60) 50 0570-060 All gas distributed by network 15

Straight nipple flat seal for regulators outlet To braze on copper To weld on steel Regulator B6 B10/25 Male meter Copper pipe Steel pipe 6/20 22 20 0977-052 6/20 26.9 (20-27) 20 0510-052 6/20 28 20 0977-054 6/20 33.7 (26-34) 20 0510-054 10/32 28 32 0977-056 10/32 33.7 (26-34) 32 0510-056 10/32 35 32 0977-058 10/32 42.4 (33-42) 32 0510-058 All gas distributed by network Straight nipple flat washer for regulators outlet To braze on copper To weld on steel Regulator Copper pipe Steel pipe BCH30 1 ¼ 28 25 0855-067 1 ¼ 33.7 (26-34) 25 0540-056 All gas distributed by network Straight lengthen regulator outlet flat seal and flat washer With collar and fixation spacer Male meter Regulator 6/20 1" ¼ 20/25 B6 0311-026 10/32 1" ½ 32 B10 / B25 0311-029 For S200 cabinet shut-off regulation regulator outlet (maintenance) Straight lengthen regulator outlet B type for PE With collar and fixation spacer Male meter PE pipe Meter / PE calibre Regulator 6/20 32 20/25 B6 0323-021 10/32 40 32/32 B10/B25 0323-023 For S200 cabinet shut-off regulation regulator outlet (maintenance) 16

Assembly fitting To weld on steel To braze on copper Copper pipe Steel pipe 18 21,3 (15-21) 15 0590-012 22 26,9 (20-27) 20 0590-013 28 33,7 (26-34) 25 0590-014 35 42,4 (33-42) 32 0590-017 42 48,3 (40-49) 40 0590-020 54 60,3 (50-60) 50 0590-022 When the assembly is made on a lead pipe, the maximal use pressure is 500 mbar All gas distributed by network Female fitting 3 pieces with sphero-conical junction - To braze on copper Female gas Copper pipe ½ 16 15 2600-070 ½ 18 15 2600-071 ¾ 22 20 2600-072 1 28 25 2600-073 1 ¼ 35 32 2600-074 1 ½ 42 40 2600-076 2 54 50 2600-077 Female fitting 3 pieces with sphero-conical junction - To weld on steel Female gas Steel pipe ½ 21.3 (15-21) 15 2600-041 ¾ 26.9 (20-27) 20 2600-042 1 33.7 (26-34) 25 2600-043 1 ¼ 42.4 (33-52) 32 2600-044 1 ½ 48.3 (40-49) 40 2600-045 2 60.3 (50-60) 50 2600-047 Male fitting 3 pieces with sphero-conical junction - To braze on copper Male conical 6.25% Copper pipe ½ 18 15 2600-081 ¾ 22 20 2600-082 1 28 25 2600-083 1 ¼ 35 32 2600-084 1 ½ 42 40 2600-085 2 54 50 2600-086 17

Male fitting 3 pieces with sphero-conical junction - To weld on steel Male conical 6.25% Steel pipe ½ 21.3 (15-21) 15 2600-051 ¾ 26.9 (20-27) 20 2600-052 1 33.7 (26-34) 25 2600-053 1 ¼ 42.4 (33-52) 32 2600-054 1 ½ 48.3 (40-49) 40 2600-055 2 60.3 (50-60) 50 2600-056 Gas steel connection for PE PE pipe Steel pipe 20 21.3 (15-21) 15 1050-009 20 33.7 (26-34) 25/15 1050-016 32 33.7 (26-34) 25 1050-023 40 42.4 (33-42) 32 1050-031 Welded on buried steel pipe Do not weld without taking apart the fitting Straight fitting 2 pieces flat seal - To braze on copper Copper pipe Fitting to type meter 6/20 22 20 G4 0795 - J07 6/20 28 20 G4 0795 - J09 10/32 28 32 G6/G10 0795 - J12 10/32 35 32 G6/G10 0795 - J15 16/40 42 40 0795 - J20 25/50 40/50 25/50 40/50 42 50 G16 G25 54 50 G16 G25 0795 - J23 0795 - J28 Delivered with aramid seal for meter outlet 6/20 22 20 G4 0795-007 6/20 28 20 G4 0795-009 10/32 28 32 G6/G10 0795-012 10/32 35 32 G6/G10 0795-015 16/40 42 40 0795-020 25/50 42 50 G16 0795-023 25/50 54 50 G16 40/50 G25 0795-028 Delivered without seal for meter outlet 18

Straight fitting 2 pieces flat seal with fixation To braze on copper Copper pipe Fitting to type meter 6/20 22 20 G4 0795 - J08 6/20 28 20 G4 0795 - J10 Delivered with aramid seal (meter outlet for S2300 cabinet) 6/20 22 20 G4 0795 - J08 6/20 28 20 G4 0795 - J10 Delivered without seal (meter outlet for S2300 cabinet) Bent fitting 90 2 pieces flat seal To braze on copper Copper pipe Fitting to type meter 6/20 22 20 G4 0796 - J52 6/20 28 20 G4 0796 - J54 10/32 28 32 G6/G10 0796 - J57 10/32 35 32 G6/G10 0796 - J59 25/50 40/50 54 50 G16 G25 0796 - J66 Delivered with aramid seal for meter outlet 6/20 22 20 G4 0796-052 6/20 28 20 G4 0796-054 10/32 28 32 G6/G10 0796-057 10/32 35 32 G6/G10 0796-059 25/50 40/50 54 50 G16 G25 0796-066 Delivered without seal for meter outlet Bent fitting 90 2 pieces flat seal To braze on copper Copper pipe Fitting to type meter 6/20 22 20 G4 0796 - J53 6/20 28 20 G4 0796 - J55 Delivered with aramid seal for meter outlet (S2300 cabinet bottom) 6/20 22 20 G4 0796-053 6/20 28 20 G4 0796-055 Delivered without seal for meter outlet (S2300 cabinet bottom) 19

Straight fitting 2 pieces flat seal To weld on steel Steel pipe Fitting to type meter 26.9 (20-27) 6/20 20 G4 0501 - J13 33.7 (26-34) 6/20 20 G4 0501 - J15 33.7 (26-34) 10/32 32 G6/G10 0501 - J17 42.4 (33-42) 10/32 32 G6/G10 0501 - J19 48.3 (40-49) 16/40 40 0501 - J22 60.3 (50-60) 25/50 40/50 50 G16/G25 0501 - J25 Delivered with aramid seal for meter outlet 26.9 (20-27) 6/20 20 G4 0501 - J13 33.7 (26-34) 6/20 20 G4 0501 - J15 33.7 (26-34) 10/32 32 G6/G10 0501 - J17 42.4 (33-42) 10/32 32 G6/G10 0501 - J19 48.3 (40-49) 16/40 40 0501 - J22 60.3 (50-60) 25/50 40/50 50 G16/G25 0501 - J25 Delivered without seal for meter outlet Outlet swanneck swivel bent at 180 flat seal with fixation To braze on copper Copper pipe Fitting to type meter 6/20 22 20 G4 0778 - J22 6/20 28 20 G4 0778 - J25 Delivered with aramid seal (meter outlet S2300 cabinet) 6/20 22 20 G4 0778 - J22 6/20 28 20 G4 0778 - J25 Delivered without seal for meter outlet Outlet swanneck swivel bent at 180 flat seal For PE pipe PE pipe Fitting to type meter Inter axis meter 10/32 40 S-bent 32 G6/G10 250 0778-227 For S300 cabinet PE inlet 20

Bent fitting at 180 flat seal To braze on copper Copper pipe Fitting to type meter 6/20 22 20 G4 0786-022 6/20 28 20 G4 0786-028 Meter outlet Only use for maintenance Bent fitting at 180 flat seal For PE pipe PE pipe Fitting to type meter Inter axis meter 6/20 32 20/25 20 160 0322-015 6/20 32 20/25 20 110 0322-016 For S300 cabinet Meter outlet Only use for maintenance Bent fitting at 180 flat seal Male meter Inter axis meter 6/20 20 110 0384-040 6/20 20 160 0384-041 10/32 20 250 0384-042 Awaiting or for meter temporary replacement Male cap with flat seal With six sides head Male meter 6/20 20 0770-052 10/32 32 0770-054 25/50 40/50 50 0770-058 Pending cap 21

Male cap with flat seal With square head Male meter Square dimension Delivered 6/20 14 20 0770-053 6/20 14 20 With seal 0770 - J53 10/32 14 32 0770-055 16/40 22 40 0770-057 25/50 22 50 0770-059 Pending cap Female cap with flat seal 6/20 20 0775-078 10/32 32 0775-080 16/40 40 0775-082 25/50 50 0775-084 Pending cap Lengthen with flat seal Male meter Length 6/20 6/20 20 50 0313-016 10/32 10/32 32 50 0313-025 10/32 10/32 32 90 0313-027 Calibration periodic check of domestic meters S -bent fitting with fla t seal Male meter Inter axis variation 6/20 6/20 20 160/110 0321-086 10/32 6/20 32/20 250/160 0380-076 Calibration periodic check of domestic meters 22

Lengthen with flat seal Male meter Inter axis variation 10/32 16/40 32/40 0314-055 10/32 25/50 32/50 0314-058 16/40 25/50 40/50 280/250 0314-059 16/40 10/32 40/32 280/250 0314-060 25/50 10/32 50/32 335/280 0314-061 25/50 25/50 50/50 335/280 0314-050 Calibration periodic check of industrial meters S -bent fitting flat seal Male meter Inter axis variation 16/40 10/32 40/32 280/250 0380-077 25/50 10/32 50/32 280/250 0380-078 25/50 10/32 50/32 335/250 0380-079 25/50 25/50 50/50 335/280 0380-080 Calibration periodic check of industrial meters S -bent fitting flat seal (set) Male meter Inter axis variation 10/32 6/20 32/20 250/110 0380-090 16/40 25/50 40/50 335/280 0380-094 25/50 25/50 50/50 335/280 0380-095 Calibration periodic check of industrial meters Straight nipple flat seal To braze on copper Male meter Copper pipe Regulator 6/20 22 20 B6 0977-052 6/20 28 20 B6 0977-054 10/32 28 32 B10/25 0977-056 10/32 35 32 B10/25 0977-058 25/50 54 50 0977-067 For regulator outlet 23

Straight nipple flat seal To weld on steel Male meter Steel pipe Regulator 6/20 26.9 (20-27) 20 B6 0510-052 6/20 33.7 (26-34) 20 B6 0510-054 10/32 33.7 (26-34) 32 B10/25 0510-056 10/32 42.4 (33-42) 32 B10/25 0510-058 16/40 48.3 (40-49) 40 0510-061 25/50 60.3 (50-60) 50 0510-062 For regulator outlet Straight fitting 2 pieces flat washer for gas riser bottom To braze on copper Copper pipe Delivered in bulk Delivered in bags of 2 1 ¼ 28 25 0794 - J09 0794 - J69 1 ½ 35 32 0794 - J13 0794 - J613 2 ¼ 54 50 0794 - J20 0794 - J620 Delivered with seal 1 ¼ 28 25 0794-009 1 ½ 35 32 0794-013 2 ¼ 54 50 0794-020 Delivered without seal Straight fitting 2 pieces flat washer for gas riser bottom To weld on steel Steel pipe Delivered in bulk Delivered in bags of 2 1 ¼ 33.7 (26-34) 25 0550 - J08 0550 - J68 1 ½ 42.4 (33-42) 32 0550 - J11 0550 - J611 2 ¼ 60.3 (50-60) 50 0550 - J15 0550 - J615 Delivered with aramid 1 ¼ 33.7 (26-34) 25 0550-008 1 ½ 42.4 (33-42) 32 0550-011 2 ¼ 60.3 (50-60) 50 0550-015 Delivered without seal 24

Straight T flat seal To braze on copper Fitting to Copper pipe type meter 6/20 28 20/25 G4 2599-028 6/20 35 20/32 G4 2599-035 6/20 54 20/50 G4 2599-054 Production of feeder tank for supply in technical locales and multi-counting boxes Bent fitting 180 male / female flat seal Male meter Fitting to type meter 6/20 6/20 20 G4 0383-075 Meter fitting to pipes with riser outlet Double female sleeve in gas quality copper To braze on copper Copper pipe 18 15 CM18 - M18 22 20 CM22 - M22 28 25 CM28 - M28 35 32 CM35 - M35 54 50 CM54 - M54 Maximal use pressure: 5 mbar Enables fitting of gas risers elements Male cap flat seal for G4 meter Male meter With square head 14 6/20 20 0770-053 With 6 sides head 6/20 20 0770-052 Installed on valve awaiting meter putting in 25

Cap 3 pieces flat seal To braze on copper Meter nut Squared Copper pipe dimension 28 6/20 20 14 2550 - J28 35 10/32 32 14 2550 - J35 54 25/50 50 22 2550 - J54 Pending cap on gas riser Female cap with flat seal Female cap flat seal 6/20 20 0775-078 Pending cap Bent fitting 90 male / female with sphero-conical junctions ¾ ¾ 15 0316-016 1" ¼ ¾ 25/15 0316-018 Fitting from pipe to valve Female straight T with sphero-conical junctions To braze on copper Copper pipe ¾ 18 15/15 2435-052 ¾ 22 15/20 2435-054 ¾ 28 15/25 2435-056 ¾ 35 15/32 2435-058 Fitting between pipe elements by brazing and connection to valve 26

Cap 3 pieces with sphero-conical junction To braze on copper Copper pipe ¾ 18 15 2560-015 1" 22 20 2560-020 1" ¼ 28 25 2560-025 1" ½ 35 32 2560-032 Pending cap Cap 3 pieces with sphero-conical junction To weld on steel Steel pipe ¾ 21,3 (15-21) 15 2570-015 1" 26,9 (20-27) 15 2570-020 1" ¼ 33,7 (26-34) 25 2570-025 1" ½ 42,4 (33-42) 32 2570-032 Pending cap Fitting for PE To braze on copper PE pipe Copper pipe 20 18 15 1120-003 32 22 25/20 1120-002 32 28 25 1120-005 40 22 32/20 1120-006 40 35 32 1120-007 63 54 50 1120-012 Take apart the fitting before brazing All gas distributed by network Fitting for PE To weld on steel PE pipe Steel pipe 20 21,3 (15-21) 15 1100-005 32 33,7 (26-34) 25 1100-007 40 42,4 (33-42) 32 1100-010 63 60,3 (50-60) 50 1100-043 90 88,9 (80-90) 80 1100-047 110 114,3 (102-114) 100 1100-049 Take apart the fitting before welding All gas distributed by network 27

Fitting sleeve for PE pipe PE pipe 20/20 15/15 1020-096 32/32 25/25 1020-098 40/40 32/32 1020-003 63/63 50/50 1020-005 All gas distributed by network Pending cap for PE pipe PE pipe PE side thickness 20 15 3 1040-051 32 25 1040-053 40 32 1040-057 20 15 2 1040-050* All gas distributed by network * 1040-050 reference is only used in maintenance, on PE pipe connections first generation Ø 20 outside Thickness 2mm (Ø 20 x Ø 16) Straight fitting with sphero-conical junction for PE PE pipe 20 ¾ 15 1030-013 32 1 ¼ 25 1030-014 40 1 ½ 32 1030-017 Reduction 32 ¾ 25/15 1070-052 20 1 ¼ 15/25 1070-053 40 1 ¼ 32/25 1070-055 All gas distributed by network Respect imperatively the tightening torques thanks to a torque wrench 28

Fitting T for PE pipe PE pipe 20/20/20 15/15/15 1080-051 32/32/32 25/25/25 1080-053 40/40/40 32/32/32 1080-058 32/20/32 25/15/25 1080-081 40/20/40 32/15/32 1080-082 63/40/63 50/32/50 1080-083 All gas distributed by network Bent fitting 90 with sphero-conical junction for PE pipe PE pipe ¾ 20 15 0318-022 ¾ 32 15 0318-024 For buried cabinet with PE inlet All gas distributed by network Straight lengthen BCH regulator outlet for PE With collar and fixation spacer PE pipe Regulator 1 ¼ 32 25 BCH30 0323-026 For S200 cabinet (maintenance) Connection grip to screw on iron for PE pipe PE pipe Tapping on iron 32 ¾ 20 1060-084 32 1 25 1060-085 40 1 ¼ 32 1060-086 63 2 50 1060-087 29

Cap to screw on iron Tapping on iron ¾ 20 0780-059 1 25 0780-060 1 ¼ 32 0780-061 2 50 0780-062 Fitting to weld on steel for PE pipe PE pipe Steel pipe 20 18 x 1.25 15 1110-003 Take apart the fitting before welding All gas distributed by network Bent fitting 90 flat seal With fixation Male meter 6/20 6/20 20 0773-089 For S2300 cabinet B6 regulator outlet and G4 meter inlet Bent inlet fitting 180 with sphero-conical junction and flat seal With fixation Meter type 1 ¼ 6/20 25/20 G4 6/20 0319-002 For S2300 cabinet low pressure assembly G4 meter inlet Transformable in medium pressure 30

Male / female collector 180 flat washer 2 ¼ 2 ¼ 50 2465-049 Shut-off S2300 cabinet with ¼ turn or security valve Bent inlet fitting 180 with sphero-conical junction and flat seal With fixation ¾ 15 2200-001 Fitting swanneck swivel G2.5 propane meter inlet (1.5 bar) Male / female straight lengthen with sphero-conical junctions Length in mm ¾ ¾ 15 100 0312-016 For fitting from security shut-off valve to inlet swanneck swivel Only cabinet with security shut-off valve / PE pipe connection S -bent lengthen with sphero-conical junctions With collar and fixation spacer Length ¾ ¾ 15 154 0312-015 ¾ 1 ¼ 15/25 0652-003 For S300 cabinet medium pressure assembly, B10 or B25 regulator (maintenance) 31

Bent fitting 90 flat seal With fixation spacer Male meter Regulator 10/32 10/32 32 B10/B25 0773-090 1 ¼ 10/32 25/32 BCH30 0779-095 For S300 cabinet medium pressure assembly, regulator outlet, G6/G10 meter inlet Bent fitting 180 with sphero-conical junction and flat seal With collar and fixation spacer Inter axis meter 1 ¼ 6/20 25/20 160 0319-003 1 ¼ 10/32 25/32 160 0319-006 1 ¼ 10/32 25/32 100 0319-007 For S300 cabinet low pressure assembly, G6/G10 meter inlet Collector with flat seal With collar and fixation spacer Male meter 10/32 6/20 32/20 0650-001 For S300 cabinet low pressure assembly G4 double counting Bent fitting 90 with sphero-conical junctions and flat seal 1 ¼ 10/32 25/32 0653-004 For S300 cabinet low pressure assembly 32

Straight lengthen with sphero-conical junctions Length ¾ ¾ 15 100 0312-016 1 ¼ 1 ¼ 25 105 0312-012 1 ¼ 1 ¼ 25 70 0312-013 For S300 cabinet and regulation post, above ground All gas Inlet collector with sphero-conical junctions for 2 regulators With collar and fixation spacer ¾ ¾ ¾ 15 0657-008 For S300 cabinet medium pressure assembly, B6 regulator double inlet, G4 double meter Bent fitting 90 flat washer for copper pipe Copper pipe 2 ¼ 54 50 2450-054 Elbow for regulator battery outlet from 50 to 120 m 3 /h Bent fitting 180 with sphero-conical junctions With collar and fixation spacer ¾ ¾ 15 0381-005 1 ¼ 1 ¼ 25 0381-007 For shut-off S100 cabinet 33

Bent fitting 180 with sphero-conical junctions With collar and fixation spacer 1 ¼ 1 ¼ 25 0386-016 1 ½ 1 ½ 32 0386-018 For shut-off S200 cabinet (maintenance) Bent nipple 90 flat seal To braze on copper With fixation spacer Male meter Copper pipe Regulator 6/20 22 20 B6 0772-065 6/20 28 20 B6 0772-066 10/32 28 32 B10/B25 0772-067 10/32 35 32 B10/B25 0772-068 For shut-off regulation S2200 cabinet regulator outlet Bent nipple 90 flat washer To braze on copper With fixation spacer Copper pipe Regulator 1 ¼ 28 25 BCH30 0771-080 For shut-off regulation S220 cabinet regulator outlet Bent fitting 90 flat seal with sphero-conical junction ¾ 6/20 15/20 0310-002 ¾ 10/32 15/32 0310-006 1 ¼ 10/32 25/32 0310-008 1 ¼ 6/20 25/20 0310-010 For low pressure assembly transformable in medium pressure (regulator pending) 34

Adapter with flat seal Female meter Male meter Length 6/20 10/32 20 16 0314-065 Enables to get from a B6 to a B10/B25 regulator during a flow increase without putting off the downstream installation Reduction lengthen with sphero-conical junctions Length 1 ¼ ¾ 25/15 143 0312-018 1 ¼ ¾ 25/15 38 0312-019 1 ½ ¾ 32/15 38 0312-021 For getting from low pressure to medium pressure B6/B10/B25/BCH30 regulator inlet Bent fitting 90 flat washer and flat seal Gas nut Meter nut 1" 6/20 25S/20 0385-005 Delivered without seal Female cap flat washer Gas nut 1" 20/25S 0785-001 Delivered without specific cap seal for CM73 valve 35

OTHERS Flexible natural gas and propane gas in network with mechanical connectors Without delay of use Length Shell Bag 1/2" 0,50 m 12 0128-050C 0128-050 1/2" 0,75 m 12 0128-075C 0128-075 1/2" 1,00 m 12 0128-100C 0128-100 1/2" 1,25 m 12 0128-125C 0128-125 1/2" 1,50 m 12 0128-150C 0128-150 1/2" 2,00 m 12 0128-200C 0128-200 Maximal use pressure: 37 mbar Delivered with seal For ROAI fitting to the domestic gas cooker in natural gas or propane distributed by network Flat washer - Aramid For fitting gas Dimension Tightening torque 1/2" Ø 12,4 x Ø 18,2 x 2 12 30 Nm 0123-046 3/4" Ø 18,4 x Ø 23,8 x 2 15 30 Nm 0123-047 1" Ø 22,4 x Ø 30 x 2 20 40 Nm 0123-048 1" Ø 26.1 x 30 x 2 25S 30 Nm 0123-049 1"1/4 Ø 30,4 x Ø 38,5 x 2 25 60 Nm 0123-053 1"1/2 Ø 38,5 x Ø 44,5 x 2 32 70 Nm 0123-050 2" Ø 45,5 x Ø 52,5 x 2 40 100 Nm 0123-051 2"1/4 Ø 53,5 x Ø 59 x 2 50 120 Nm 0123-052 Flat washer - Elastomer For fitting Tightening Dimension gas torques 1/2" Ø 11,4 x Ø 17,2 x 2 12 0123-000 3/4" Ø 17,4 x Ø 22,8 x 2 15 0123-002 1" Ø 21,4 x Ø 29 x 2 20 0123-105 1"1/4 Ø 29,4 x Ø 37,5 x 2,5 25 25 Nm 0123-008 1"1/2 Ø 37,5 x Ø 43,5 x 2,5 32 0123-013 2" Ø 44,5 x Ø 55 x 2,5 40 0123-016 2"1/4 Ø 52,5 x Ø 65 x 2,5 50 50 Nm 0123-018 36

Torque wrenches Case of fork wrenches for gas connection Habitat case Habitat and industry case Composition 1 spanner 4 forks 1 spanner 9 forks Forks for 6 sides nuts on flat 24-32 - 36-50 2807-001 24-32 - 36-41 - 50-55 - 65-70 - 75 2807-002 For the seal tightening to the torques defined in the NF E29-533 (flat washer) and NF E29-532 (flat seal) standards Airtight control device of inside installations Composition 1 plastic box with inside wedge 1 pressure gauge Ø63-0 to 60 mbar integrated in a metal box with hang strap 1 inflating manual system with fast clip 1 flexible turning connector for pressure point 1 adaptation fitting for pressure point 1 adaptation fitting M1/2 x M6/20 (meter) 1 adaptation fitting M1/2 x M20 x 150 1 foaming product aerosol (leak research) 2420-006 Enables to control lack of permanent piping leak Option: Air micro-compressor cabinet Composition 1 plastic box 1 micro compressor maximal pressure 100 mbar 1 delivered LR20 alkaline battery (1,5 volt) 1 flexible turning connector for pressure point 1 adaptation fitting for pressure point 2420-008 Replaces the inflating manual system during the airtight control of inside installations 37

Buffer tank When it is necessary to plan a buffer space to absorb the fast pressure variations, especially when the solenoids are situated after a B type regulator, the piping volume from the regulator to the consumption point has to be at least equal: - in BP (21,27,37 mbar) to 1/500 of the regulator nominal flow - in MPA (300 mbar) to 1/1000 of the regulator nominal flow Designation Fitting double female 2 transition fittings pressure gauge Tank 10 L 1" ¼ ¼ 2420-010 Tank 25 L 1" ½ ¼ 2420-025 Tank 50 L 1" ½ ¼ 2420-050 Horizontal or vertical assembly Delivered with caps on both transition fittings Fixation plate of meter replacement Fixation on wall Male meter Inter axis variation 6/20 6/20 20 160/110 0301-010 10/32 6/20 32/20 250/110 0301-020 Calibration periodic check of domestic meters Fixation plate of meter replacement Fixation on Lovaert plate Male meter Inter axis variation 6/20 6/20 20 160/110 0301-011 10/32 6/20 32/20 250/110 0301-021 Calibration periodic check of domestic meters Flat seal in aramid Synthetic fibres elastomer For nut Dimension Tightening torque 6/20 Ø22.6 x Ø27.5 x 2 20 30 Nm 0345-040 10/32 Ø34.2 x Ø40 x 2 15 50 Nm 0345-041 16/40 Ø47.2 x Ø54 x 2 20 100 Nm 0345-043 25/50 Ø54.2 x Ø60 x 2 25 120 Nm 0345-044 Respect imperatively the tightening torques 38

Flat seal in flexible elastomer For nut Tightening Dimension torque 6/20 Ø21.4 x Ø26.3 x 2.5 20 25 Nm 0345-002 10/32 Ø33 x Ø38.8 x 2.5 15 30 Nm 0345-005 16/40 Ø46 x Ø52.8 x 2.5 20 40 Nm 0345-009 25/50 Ø53 x Ø58.8 x 2.5 25 50 Nm 0345-011 Respect imperatively the tightening torques Plumbing pin for valve Ø Length 2.5 30 0210-012 2.5 40 0210-014 3 40 0210-016 3 60 0210-018 For locking of older valves Locking screw for ¼ turn, security and Securoc valve 0220-008 Rearmament key for emergency shut-off valve Kind of valve Clesse / Chuchu 0220-018 3 uses key 3 functions Cabinet door opening 1. Rectangular keyhole 2. Triangular keyhole 0220-019 3. Manoeuvre of ¼ turn valve 14 mm head with square 39

EQUIPPED CABINETS Chuchu Decayeux offers a wide range of cabinets which match all types of gas installations, distributed by network, for all network connections to buildings. Cabinets enable to shut-off the gas (shut-off), reduce pressure from network (regulation) and ensure metering in m 3 (metering). There are several selection criteria: the cabinet main function (shut-off, shut-off/regulation, shut-off/regulation/metering, shut-off/metering), inlet and outlet piping (copper, steel or PE), cabinet external dimensions, inlet maximal use pressure (from 21 mbar and 4 bar) and outlet maximal use pressure (from 21 to 300 mbar). Bases are always optional In order to ease your request, we have created a document which enables to gather cabinet descriptive Consult us by phone +33 3 22 20 75 25 or fax +33 3 22 30 37 65 copying and filling in the following document 40

EQUIPPED CABINETS Fact sheet for cabinets equipment Document to copy and fax well-filled to +33 3 22 30 37 65 Society: _ Town: _ Country: Name, Surname: _ Phone Number: _ Fax: Date: _ Distributed Gas: Natural gas Network propane Cabinet Function: Shut-off Shut-off/regulation Shut-off/regulation/metering Meters number _ Regulators number _ Cabinet type: S22 S2300 S300 Simple Full door Full door High Window Window Base Base Base Post Shut-off valve: ¼ turn Security Emergency shut-off Securoc Inlet pressure: 4 bar 1.5 bar 300 mbar 21, 27 or 37 mbar Outlet pressure: 300 mbar 21 mbar 27 mbar 37 mbar Other: mbar Flow: m 3 /h natural gas Kg/h propane network Power: Kw/h Inlet fitting external Ø in mm: Copper Ø 18 22 28 35 54 Steel Ø 21.3 26.9 33.7 42.4 60.3 PE Ø 20 32 40 63 Outlet fitting external Ø in mm: Copper Ø 18 22 28 35 54 Steel Ø 21.3 26.9 33.7 42.4 60.3 PE Ø 20 32 40 63 41

INNOVATIONS Vigigaz is the first gas ball valve which shuts off automatically via a radio signal from gas detector. Much more than a simple ball valve, Vigigaz is an innovative concept dedicated to the safety of people and possessions. Vigigaz can be installed in all types of gas installations. The VIGIGAZ concept: the gas supply is automatically closed when the slightest smoke, carbon monoxide or gas leak is detected 42

PE CLIP is a simple and reliable solution for all your mechanical Pe transition fitting requirements. Direct Pe insertion with no prior disassembly No special tools, a standard spanner is all that is required Positive nut stop with no specific tightening torque Rapid installation with visual control Reusable fitting with no need to change the sealing elements Fitting certified by NF EN 1555 standard 43

CONTENTS History & Activity 1 VA L VE S Automatic shut-off ball valve ROAI 2 Shut-off valve double male flat washer 2 Security gas valve double male flat washer 2 SECUROC double male with sphero-conical junctions and fixation bracket Without pressure point 3 SECUROC double male with sphero-conical junctions and fixation bracket With pressure point 3 SECUROC for PE with sphero-conical junctions and fixation bracket With pressure point 3 Gas valve double male with sphero-conical junction and fixation bracket With locking screw - Without pressure point 4 Gas valve for PE with sphero-conical junction and fixation bracket With locking screw - Without pressure point 4 Gas valve double male with sphero-conical junction and fixation bracket Without pressure point 4 Gas valve for PE with sphero-conical junction and fixation bracket Without pressure point 5 Gas valve for PE and with copper pipe fitting Without locking screw and pressure point 5 Gas valve double fittings copper pipe Without locking screw and pressure point 5 Meter valve Ds type flat seal With locking screw 6 C type gas valve for gas riser bottom 6 Shut-off gas valve double male with sphero-conical junctions With locking screw 6 Gas valve for substitution shut-off ¼ turn flat washer With locking screw 7 Shut-off gas valve for PE and with sphero-conical junctions With fixation bracket - With locking screw - With pressure 7 Security gas valve for PE and with sphero-conical junction With fixation bracket - With pressure 7 44

Gas valve double male with sphero-conical junctions with fixation bracket With locking screw With pressure point 8 Security gas valve double male with sphero-conical junctions with fixation bracket With pressure point 8 F I T TI N G S Straight fitting 2 pieces flat washer To braze on copper 9 Straight fitting 2 pieces flat washer To weld on steel 10 Elbow 2 pieces flat washer 10 Elbow 2 pieces flat washer Conical 6.25% 10 Elbow 2 pieces flat washer To braze on copper 11 Cap female flat washer 11 Cap male flat washer 11 Straight fitting 2 pieces flat washer Conical 6.25% 11 Straight fitting 1 piece flat washer 12 Straight lengthen flat washer For PE 12 Straight nipple flat washer To braze on copper 12 Straight nipple flat washer To weld on steel 13 Female cap flat washer 13 Straight fitting 2 pieces with sphero-conical junction To braze on copper 13 Straight reduction fitting 2 pieces with sphero-conical junction To braze on copper 14 Straight fitting 2 pieces with sphero-conical junction To weld on steel 14 Straight reduction fitting 2 pieces with sphero-conical junction To weld on steel 14 Straight fitting with sphero-conical junction For PE 14 Female cap 2 pieces with sphero-conical junction 15 Insulating fitting with sphero-conical junctions 15 Straight nipple with sphero-conical junction for regulators inlet To braze on copper To weld on steel 15 Straight nipple flat seal for regulators outlet To braze on copper To weld on steel 16 Straight nipple flat washer for regulators outlet To braze on copper To weld on steel 16 Straight lengthen regulator outlet flat seal and flat washer With collar and fixation spacer 16 Straight lengthen regulator outlet B type for PE With collar and fixation spacer 16 Assembly fitting To weld on steel To braze on copper 17 Female fitting 3 pieces with sphero-conical junction - To braze on copper 17 Female fitting 3 pieces with sphero-conical junction - To weld on steel 17 Male fitting 3 pieces with sphero-conical junction - To braze on copper 17 Male fitting 3 pieces with sphero-conical junction - To weld on steel 18 45

Gas steel connection for PE 18 Straight fitting 2 pieces flat seal - To braze on copper 18 Straight fitting 2 pieces flat seal with fixation To braze on copper 19 Bent fitting 90 2 pieces flat seal To braze on copper 19 Bent fitting 90 2 pieces flat seal To braze on copper 19 Straight fitting 2 pieces flat seal To weld on steel 20 Outlet swanneck swivel bent at 180 flat seal with fixation To braze on copper 20 Outlet swanneck swivel bent at 180 flat seal For PE pipe 20 Bent fitting at 180 flat seal To braze on copper 21 Bent fitting at 180 flat seal For PE pipe 21 Bent fitting at 180 flat seal 21 Male cap with flat seal With six sides head 21 Male cap with flat seal With square head 22 Female cap with flat seal 22 Lengthen with flat seal 22 S-bent fitting with flat seal 22 Lengthen with flat seal 23 S-bent fitting flat seal 23 S-bent fitting flat seal (set) 23 Straight nipple flat seal To braze on copper 23 Straight nipple flat seal To weld on steel 24 Straight fitting 2 pieces flat washer for gas riser bottom To braze on copper 24 Straight fitting 2 pieces flat washer for gas riser bottom To weld on steel 24 Straight T flat seal To braze on copper 25 Bent fitting 180 male / female flat seal 25 Double female sleeve in gas quality copper To braze on copper 25 Male cap flat seal for G4 meter 25 Cap 3 pieces flat seal To braze on copper 26 Female cap flat seal 26 Bent fitting 90 male / female with sphero-conical junctions 26 Female straight T with sphero-conical junctions To braze on copper 26 Cap 3 pieces with sphero-conical junction To braze on copper 27 Cap 3 pieces with sphero-conical junction To weld on steel 27 Fitting for PE To braze on copper 27 Fitting for PE To weld on steel 27 Fitting sleeve for PE pipe 28 Pending cap for PE pipe 28 Straight fitting with sphero-conical junction for PE 28 Fitting T for PE pipe 29 46

Bent fitting 90 with sphero-conical junction for PE pipe 29 Straight lengthen BCH regulator outlet for PE With collar and fixation spacer 29 Connection grip to screw on iron for PE pipe 29 Cap to screw on iron 30 Fitting to weld on steel for PE pipe 30 Bent fitting 90 flat seal With fixation 30 Bent inlet fitting 180 with sphero-conical junction and flat seal With fixation 30 Male / female collector 180 flat washer 31 Bent inlet fitting 180 with sphero-conical junction and flat seal With fixation 31 Male / female straight lengthen with sphero-conical junctions 31 S-bent lengthen with sphero-conical junctions With collar and fixation spacer 31 Bent fitting 90 flat seal With fixation spacer 32 Bent fitting 180 with sphero-conical junction and flat seal With collar and fixation spacer 32 Collector with flat seal With collar and fixation spacer 32 Bent fitting 90 with sphero-conical junctions and flat seal 32 Straight lengthen with sphero-conical junctions 33 Inlet collector with sphero-conical junctions for 2 regulators With collar and fixation spacer 33 Bent fitting 90 flat washer for copper pipe 33 Bent fitting 180 with sphero-conical junctions With collar and fixation spacer 33 Bent fitting 180 with sphero-conical junctions With collar and fixation spacer 34 Bent nipple 90 flat seal To braze on copper With fixation spacer 34 Bent nipple 90 flat washer To braze on copper With fixation spacer 34 Bent fitting 90 flat seal with sphero-conical junction 34 Adapter with flat seal 35 Reduction lengthen with sphero-conical junctions 35 Bent fitting 90 flat washer and flat seal 35 Female cap flat washer 35 47

O T H ER S Flexible natural gas and propane gas in network with mechanical connectors Without delay of use 36 Flat washer Aramid 36 Flat washer Elastomer 36 Torque wrenches Case of fork wrenches for gas connection 37 Airtight control device of inside installations 37 Option: Air micro-compressor cabinet 37 Buffer tank 38 Fixation plate of meter replacement Fixation on wall 38 Fixation plate of meter replacement Fixation on Lovaert plate 38 Flat seal in aramid Synthetic fibres elastomer 38 Flat seal in flexible elastomer 39 Plumbing pin for valve 39 Locking screw for ¼ turn, security and Securoc valve 39 Rearmament key for emergency shut-off valve 39 3 uses key 39 E Q UI P P ED CA BI N E TS Equipped cabinets presentation 40 Fact sheet for cabinets equipment 41 I N NO VA TI ONS Vigigaz 42 PE Clip 43 48