HART Communications Board

Similar documents
Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Technical Bulletin, Communicating with Gas Chromatographs

Ultima. X Series Gas Monitor

4000 series (includes 4100, 4200 & 4900)

ACV-10 Automatic Control Valve

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

PRODUCT MANUAL. Diver-MOD

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

Built-in Purge Control Functions

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

BUBBLER CONTROL SYSTEM

HOT SPOT MONITOR (HSM)

CNC Communication Protocol

APPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S

Device Description User Manual Logix 520MD Positioners

M2110P SMART PRESSURE GAUGE USER S MANUAL

DeeterFlow Automatic Liquid Dispenser

Description of Device Parameters Proline Prowirl 200 HART. Vortex flowmeter. Products Solutions Services. Main menu Language.

BUBBLER CONTROL SYSTEM

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

CONTROL and INSTRUMENTATION

SHIMADZU LC-10/20 PUMP

QIRF REFRIGERANT GAS TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL

PTG100 Precision Test Gauge

Fixed Ozone Monitor User Manual December, Automatikprodukter

RAM Operation Manual

2.5 Electrical Installation

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Overview. Front Panel: Keypad and Display

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Sample Draw Oxygen Monitoring System (OMS) User Manual

STANDARD OPERATING PROCEDURE

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

Detcon MicroSafe Model DM-534C Oxygen Deficiency Sensor (0-25% O2)

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

Datasheet: K-30 ASCII Sensor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Hydro-Control V User Guide

Design Envelope Booster. Sequence of operation

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.

Trace Oxygen Analyzer

QRAE II Quick Reference Covers Diffusion & Pump Models with Firmware Version 3.12 and higher

MODEL ITS-8000 SERIES NON-INTRUSIVE CALIBRATION INDUSTRIAL TRANSMITTER/SENSOR

A TECHNICAL REFERENCE

Sensoric 4-20 ma Transmitter Board Operation Manual

Special Documentation Proline Promass 80, 83

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

HyperSecureLink V6.0x User Guide

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Pneumatic high-pressure controller Model CPC7000

Controlling the prefeeder

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Series OV-110 Omni-Valve

RAM 4021-DPX Operation Manual

Valve Communication Solutions Axiom

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

IMVS2000v2 INSTALLATION OPERATING MANUAL MAN720. Integrated Monitoring Valve System. Copyright by BIFFI ITALIA. All rights reserved.

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

Operation & Maintenance Manual GDS-68XP

Helium Level Measurement Unit

Using the UltraRAE. Firmware 2.35

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

HY-OPTIMA 740 In-Line Process Hydrogen Analyzer (%H 2 S & CO)

Series OV-110 Omni-Valve

User Manual. asense miii. / CO sensor with built-in general purpose controller

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

Connect with Confidence NO POWER NO PROBLEM

User manual CF8-D/W-IN

Pneumatic high-pressure controller Model CPC7000

AN-140. Protege WX SALLIS Integration Application Note

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

MONSOON 6V Pump Control System

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

EX-5150-MOS Sensor/Transmitter For PPM or %LEL Manual

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

CTS-M1816 CARBON MONOXIDE TRANSMITTER/SENSOR

PRELIMINARY DATASHEET

210 Series Transmitter with External Electrochemical Sensor

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Operating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

RAM 4021 Operation Manual

Installation and Operation Manual

NOVATECH OXYGEN /CARBON DIOXIDE ANALYSER /TRANSMITTER MODEL 1537

PRODUCT MANUAL. Diver-DCX

Transcription:

- HART Communications Board (Highway Addressable Remote Transducer) User Manual Document No. Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602 +1 727-539-0550 [fax] web: www.sensidyne.com e-mail: info@sensidyne.com Sensidyne Document 1

Set Up NOTE The HART Communications Board is installed at the factory and prewired to the Three wire Non IS Power Supply Board. Make certain you preserve the prewired connections when you wire the power supply during transmitter installation (Refer to the Transmitter User Manual [PN 360-0152- 01]). HART communications wiring should connect to the labeled terminals of TP1 on the Three wire Non IS power supply board in the base of the transmitter. 2 Sensidyne Document

Refer to SensAlert ASI User Manual (P/N: 360-0152-01) The following section is reprinted from the SensAlert ASI User Manual. A properly installed HART Communication Board will indicate Hart Comm at step 5.2.5.5. If Modbus Comm. Or No Comm Installed appears, an improper Board has been installed in the transmitter. 5.2 Main Menu As shown on the example display to the right, the top level (main) menu allows the selection of several submenus, documented below. Selecting ACK brings up the submenus. Main Menu Calibration Mode Maintenance Mode Data Review Test On Demand > System Configuration Lost Password 5.2.5 System Configuration The System Configuration menu provides a large number of functions for configuring the operation of the unit. These include conducting a self test, alarm and relay setup, adjusting the 4 ma & 20 ma outputs, setting the date and time, communications setup, adjusting TOD cell functions, setting combustible sensor parameters, and setting a password. System Configuration > Self Test Alarm Settings 4/20 ma Adjustment Adjust Date/Time Communication Setup TOD Mode Adjustment --more-- 5.2.5.5 Communication Setup This menu provides adjustment for both standard and optional installed communications methods. Options installed will be displayed. Possible options are Hart Comm Modbus Comm (If no Communications Option is installed Display will read) No Comm Installed Communication Setup > 4/20mA Communication Modbus Comm Hart Comm HART Comm No User Adjustments Through this Interface Use Current Loop Sensidyne Document 3

5.2.3 Data Review Data review allows the examination of data stored by the unit. Data reviews are available for the Test-On-Demand gas generating cell, the installed sensor, Fault Currents, Active Alarms/Faults, Rly Alm Fault Config., Calibration Info, and Communication Review. Data Review > Calibration Info Sensor Status Sensor Data Active Alarms/Faults Fault Currents Fault Current Delay -- more -- Data Review -- more -- Rly Alm Fault Config TOD Data Review Communication Review Firmware Review 5.2.3.7 Communication Review The Communication Review screen displays the present setting Of the 4/20mA Current Loop (SensAlert sensor ID or None). Depending on which Communications Option is installed (None, HART, or Modbus) the display will vary. 4 Sensidyne Document

5.1 Menu Map 5.2.3.6 Communication Setup 5.2.3.6.1 4-20ma Communications 5.2.3.6.1.1 None 5.2.3.6.1.2 SensAlert Sensor ID 5.2.3.6.2 Communication Set Up 5.2.3.6.2.1 Hart Comm 5.2.3.6.2.1.1 No User Adjustments Through this Interface Use Current Loop 5.2.3.6.2.2 Modbus Comm 5.2.3.6.2.2.1 Modbus Address 5.2.3.6.2.2.2 Baud Rate 5.2.3.6.2.2.3 Parity 5.2.3.6.2.2.4 Stop bits 5.2.3.6.2.3 No Comm Installed 5.2.3.6.2.3.1 No Communications Board Installed Sensidyne Document 5

5.2.3.7 Communications Review 5.2.3.7.1 4/20mA Communications 5.2.3.7.1.1 None or SensAlert Sensor ID 5.2.3.7.2 HART Comm or Modbus or No Comm Installed 5.2.3.7.2.1 HART 5.2.3.7.2.1.1 No User Adjustments Through this Interface Use Current Loop 5.2.3.7.2.2 Modbus 5.2.3.7.2.2.1 Modbus Address XXX 5.2.3.7.2.2.2 Baud Rate 5.2.3.7.2.2.2.1 9600 or 19200 or 38400 5.2.3.7.2.2.3 Parity 5.2.3.7.2.2.3.1 None or Odd or Even 5.2.3.7.2.2.4 Stop Bits 5.2.3.7.2.2.4.1 1 or 2 5.2.3.7.2.3 No Comm Installed 6 Sensidyne Document

Implemented HART Commands This section provides information about the implementation of the HART Protocol on the Sensidyne SensAlert ASI Transmitter. The basis of Sensidyne s implementation of the HART protocol is HART Revision 5 with one device specific command to allow updating of certain dynamic variables. This command will allow the HART host software to change alarm levels, enable/disable alarms, etc. The following HART Commands have been implemented in the SensAlert ASI device. Hart commands are divided as follows: Universal Commands (UC), Common Practice Commands (CPC), and Device Specific Command (DSC). Universal Commands Command Label 0 Read unique identifier 1 Read primary variable Function / Description Mfg ID = 81 Device Type = 239 Device ID = 001 (SensAlert boards are not serialized; all will report Device ID 001) Primary Variable is Gas Concentration. [Dynamic variable #1 ]. Appropriate units will be reported. 2 Read current & % of range 3 Read current and four (predefined) dynamic variables Loop current is reported in ma.[dynamic variable #0 ]. Percent of range is reported in %. Loop current is reported in ma. [Dynamic variable #0 ] Primary Variable is Gas Concentration. [Dynamic variable #1 ] Secondary Variable is TWA Gas Concentration. [Dynamic variable #2 ] Third Variable is Sensor Temperature. [Dynamic variable #3 ] Fourth Variable is Sensor Type.[Dynamic variable #4 ] 12 Read message 13 Read tag, descriptor, date The 32 character message is read from internal non-volatile memory and reported to the HART host. The 8 character TAG, 16 character DESCRIPTOR and the DATE are read from internal non-volatile memory and reported to the HART host. 17 Write message 18 Write tag, descriptor, date The 32 character message provided by the HART host is written to internal non-volatile memory. The 8 character TAG, 16 character DESCRIPTOR and the DATE provided by the HART host are written to internal non-volatile memory. Sensidyne Document 7

Common Practice Commands Command 33 Read Dynamic Variable. Up to four dynamic variables can be requested by the HART host and their current values will be reported with appropriate units to the host. The following table lists the dynamic variables. Var # Description Units 0 Loop Current ma 1 Primary Variable (PV) - Gas Concentration Gas Units 2 TWA Gas Concentration Gas Units 3 Sensor Temperature Deg Celsius 4 Sensor Type - 16-bit value (Converted to 32-bit float for HART) No Units 5 Maximum / Full Scale Value Gas Units 6 Minimum Span Gas Units 7 Maximum Span Gas Units 8 Alarm 1 Setpoint Gas Units 9 Alarm 2 Setpoint Gas Units 10 Alarm 3 Setpoint Gas Units 11 TWA Alarm Setpoint Gas Units 12 Cal Pre Exposure Gas Units 13 Cal Gas Concentration Gas Units 14 Date of Last Calibration - Year No Units 15 Date of Last Calibration Month No Units 16 Date of Last Calibration Day Days 17 Time of Last Calibration - Hour Hours 18 Time of Last Calibration - Minute Minutes 19 Time of Last Calibration - Second Seconds 20 TOD Peak Value Gas Units 21 Date of Last TOD - Year No Units 22 Date of Last TOD - Month No Units 23 Date of Last TOD - Day Days 24 Time of Last TOD - Hour Hours 25 Time of Last TOD Minute Minutes 26 Time of Last TOD - Second Seconds 27 Display S/W Version No Units 28 Comm S/W Version No Units 29 Head Unit S/W Version No Units Table Continued on next page 8 Sensidyne Document

Var # Description Units 30 Sensor S/W Version No Units 31 Maximum Gas Concentration Gas Units 32 Date of Maximum Gas Concentration - Year No Units 33 Date of Maximum Gas Concentration - Month No Units 34 Date of Maximum Gas Concentration - Day Days 35 Date of Maximum Gas Concentration - Hour Hours 36 Date of Maximum Gas Concentration - Minute Minutes 37 Date of Maximum Gas Concentration - Second Seconds 38 Minimum Sensor Temperature Deg Celsius 39 Date of Minimum Temperature - Year No Units 40 Date of Minimum Temperature - Month No Units 41 Date of Minimum Temperature - Day Days 42 Date of Minimum Temperature - Hour Hours 43 Date of Minimum Temperature - Minute Minutes 44 Date of Minimum Temperature - Second Seconds 45 Maximum Sensor Temperature Deg Celsius 46 Date of Maximum Temperature - Year No Units 47 Date of Maximum Temperature - Month No Units 48 Date of Maximum Temperature - Day Days 49 Date of Maximum Temperature - Hour Hours 50 Date of Maximum Temperature - Minute Minutes 51 Date of Maximum Temperature - Second Seconds Note: When a gas sensor is plugged into the head, the appropriate units for that type of gas is reported to the HART communications board. The correct units for the selected gas will be used for any of the variables that have Gas Units in the units column. Sensidyne Document 9

Command 48 Read Additional Device Status. At the HART host s request, 48 status bits (i.e., 6 status bytes) are reported to the hosts. The table below lists the definitions of the 48 status bits reported by Command 48. Byte 0 Bit 0 TOD Failed Bit 1 Not Used Bit 2 Not Used Bit 3 Not Used Bit 4 Not Used Bit 5 Not Used Bit 6 Not Used Bit 7 Not Used Byte 1 Bit 0 Zero Started Bit 1 Zero Good Bit 2 Zero Failed Bit 3 Calibration Started Bit 4 Calibration Good Bit 5 Calibration Failed Bit 6 TOD Started Bit 7 TOD Good Byte 2 Bit 0 Relay 1 Latching Bit 1 Relay 2 Latching Bit 2 Relay 3 Latching Bit 3 Relay 4 Latching Bit 4 Not Used Bit 5 Not Used Bit 6 TOD Test Fail Active Bit 7 TOD Fail Enable Byte 3 Bit 0 Alarm 1 Active Bit 1 Alarm 2 Active Bit 2 Alarm 3 Active Bit 3 Alarm 4 Active Bit 4 Alarm 1 Enabled Bit 5 Alarm 2 Enabled Bit 6 Alarm 3 Enabled Bit 7 Alarm 4 Enabled Byte 4 Bit 0 Head Fail Enable Bit 1 Sensor Missing Enable Bit 2 Sensor Fail Enable Bit 3 Sensor End of Life Enable Bit 4 TOD End of Life Enable Bit 5 Loop Current Out of Tolerance Fault Enable Bit 6 Calibration Mode Active Fault Enable Bit 7 Maintenance Mode Active Fault Enable Byte 5 Bit 0 Head Fail Bit 1 Sensor Missing Bit 2 Sensor Fail Bit 3 Sensor End of Life Bit 4 TOD End of Life Bit 5 Loop Current Out Of Tolerance Bit 6 Calibration Mode Active Bit 7 Maintenance Mode Active 10 Sensidyne Document

Device Specific Command Device Specific Command 79 Write Dynamic Variable. This command is borrowed from HART Revision 6 and is formatted in the same way. A single HART variable number along with a floating point value is provided by the HART host. The action performed by the SensAlert ASI device in response to this command is outlined below. The following 4 variables can be directly updated by the HART host: Dynamic Variable 8 = Alarm 1 Setpoint Dynamic Variable 9 = Alarm 2 Setpoint Dynamic Variable 10 = Alarm 3 Setpoint Dynamic Variable 11 = TWA Alarm Setpoint Various bit functions can be changed through special use of this command. Bit functions have coil numbers assigned to them. To turn on a bit function, Dynamic Variable 40 is loaded with the coil number related to the selected bit function. To turn off a bit function, Dynamic Variable 41 is loaded with the coil number related to the selected bit function. Any requests to update variables other than 8, 9, 10, 11, 40 or 41 will be ignored. The table below lists the Coil Numbers writable by the HART host along with their designated functions. Coil 0 Coil 3 Coil 6 Coil 9 Coil 16 On -> Start Zeroing Sensor On -> Start Sensor Calibration On -> Start TOD On -> Stop Sensor Calibration On -> Clear Latched Relays Coil 20 Enable/Disable Alarm 1 Coil 21 Enable/Disable Alarm 2 Coil 22 Enable/Disable Alarm 3 Coil 23 Enable/Disable Alarm 4 Coil 24 Coil 25 Coil 26 Coil 27 Enable/Disable Relay 1 Latching Enable/Disable Relay 2 Latching Enable/Disable Relay 3 Latching Enable/Disable Relay 4 Latching Coil 31 Coil 40 Coil 41 Coil 42 Coil 43 Coil 44 Coil 45 Coil 46 Coil 47 Enable/Disable TOD Fail Enable/Disable Head Fail Enable/Disable Sensor Missing Enable/Disable Sensor Fail Enable/Disable Sensor End Of Life Enable/Disable TOD End of Life Enable/Disable Loop Calibration Out Of Tolerance Enable/Disable Calibration Mode Active Fault Enable/Disable Maintenance Mode Active Fault Sensidyne Document 11

For further information about the HART protocol contact the HART Communication Foundation at www.hartcomm.org HART Communication Foundation 9390 Research Blvd., Suite I-350 Austin TX 78759 Tel: 512-794-0369 Fax: 512-794-3904

Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602 +1 727-539-0550 [fax] web: www.sensidyne.com e-mail: info@sensidyne.com Sensidyne Document 13