Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

Similar documents
Target Cleanliness Worksheet. Systemic Contamination Control

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

SULLAIR SX Filtration Series ,000 scfm

PRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED.

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Directional Controls

Directional Controls

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

ACTUATORS AND INSTRUMENTS

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

TECHNICAL DATA. Q = C v P S

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIRLINE-SERIES HELMET AIR FILTER

Pilot Check Valve: Metal Body Type

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

INSTRUCTION MANUAL FOR UNDERWATER OPERATION

Copyright, 2005 GPM Hydraulic Consulting, Inc.

TECHNICAL DATA. Q = C v P S

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

MUD 1. Vent check valves. Instruction and maintenance manual.

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

TURBINE SEAL: AXIAL TYPE DESIGN

Float Operated Level Controllers

Liquid Level Controllers

Installation, Operation and Maintenance Manual for Back Pressure Regulator

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

PVQ 13 A2 R SE 1 S 20 C-11 D

TECHNICAL DATA OBSOLETE

Purge Star & Ring Purge Systems

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Advanced Fluid Handling Cart Owner s Manual

INSTRUCTION MANUAL FOR UNDERWATER OPERATION

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

TECHNICAL DATA. Q= Cv S

MF2M Monnier Miniature Compressed Air Filter

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Unit 24: Applications of Pneumatics and Hydraulics

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Nitrogen Tyre Inflator Owner s Manual

Compressed Air - Food/Bev. Presented By: Adam Zimmerman

TECHNICAL DATA CAUTION

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Full Internal Relief Valves Instruction Manual

Inert Air (N2) Systems Manual

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

BS Series Basket Strainer

Maintenance handbook

FILTER TYPE PRESSURE SNUBBER

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Pre-filter for Brushless Blower Instruction Manual

4400 TwinHybrid Gas Seal

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Series BLK Oil - air cooler

Electro-Pneumatic Converter YT-940 SERIES

Series IRV1000/2000/3000

GRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS

Electropneumatic Transducer (I/P) Installation, Operation and

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Guardian Membrane Separators

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Tri-Tech Medical Inc.

VB-7263 Series. Application. Features. Applicable Literature

Related Products: Auto Drain Valve. Model/Specifications. Model

444C DUAL PERFORMANCE VALUE PACK

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Transcription:

Vickers Filters Reservoir Vent Filters Spin-on Air Filters & Adaptors Rev. 3/98 73

Introduction Prevent Airborne Ingression A key element of contamination control is reservoir vent filtration. Reservoir vents are a common source of both water and particulate contamination from the atmosphere surrounding a hydraulic system. Fluid contamination can increase: Equipment wear Cause corrosion Reduce fluid performance and life Hydraulic components have become more complex and operate at higher pressures, flows and temperatures thus making fluid cleanliness a key to longer component life and system reliability. Vickers reservoir vent breathers make it easier to attain higher cleanliness levels, and can extend fluid filter life in the system. Vickers Offers Hi-Tech Options Vickers recognizes the variety of atmospheric conditions which hydraulic systems encounter, so we offer a complete line of vent filters to prevent airborne contamination. Requirement H2O-Gate DIRT-Gate V211 V191 Visual Indication* Particle Control Water/Moisture Control Corrosion Resistant Housing * For systems where a visual indicator cannot be seen for inspection and subsequent action, Vickers recommends service for the vent filter after 5 hours of machine operation. Contents H 2 O-Gate Model Code & Installation....................................................................... 3 H 2 O-Gate Pressure Drop................................................................................ 3 DIRT-Gate Model Code & Installation...................................................................... 4 DIRT-Gate Pressure Drop............................................................................... 4 V211 and V191 Spin-on Elements....................................................................... 5 Spin-on Vent Filter Adaptors............................................................................. 6 Bayonet Adaptors...................................................................................... 7 Bayonet Adaptors Pressure Drop.......................................................................... 7 System Sampling Frequency Chart....................................................................... 8 2

H 2 O-Gate Element Model Code BR11 Specifications Housing Material - ABS Plastic Temperatures - Up to 121 C (25 F) Efficiency - 99% at 3 micron Features & Benefits Rugged ABS plastic housing can be exposed to temperatures as high as 121 C (25 F), and is corrosion resistant. Visual mechanical indicator, which triggers at P,7 bar (1 psid) (during exhalation). Easy installation. Lightweight design requires only hand tightening. Low pressure drop across filter media reduces stress on reservoir and system components. Reversible flow-through media in the H 2 O-Gate allows moisture to exit while filter regenerates its capacity to prevent moisture ingression. Plated steel core prevents filter media distortion. Inhalation Á Exhalation Temperature Difference C ( F) 5 (9) 45 (81) 4 35 3 25 2 15 1 5 (72) (63) (54) (45) (36) (27) (18) Installation Dimensions mm (inches) (9) Effective applications 133,4 (5.25) Á Á Inches of water 3. 2.7 2.2 2. 1.7 1.2 1..7.2 Pressure Drop Fluid Displacement l/min (USgal) 283 (75) 85 (225) 19 (.75) 12 (.47) 1.5 UN Straight Thread 184,2 (7.25) 416 (375) 1982 (525) 246 (675).75 (.18).5 (.73).25 (.36) bar (psi) Performs as a gate. During the inhalation cycle, the H 2 O-Gate proprietary media blocks the water vapor from entering the reservoir. During the exhalation cycle, the media allows the moisture in the reservoir air to exit. The moisture is blown off the media by the exiting air, restoring the media s water barrier capacity, and the moisture barrier mechanism is not affected by the amount of exposure to moisture. The reservoir air is maintained at a low relative humidity, and more importantly, at a lower dew point temperature than the ambient temperature. 1 2 3 4 5 6 7 8 9 1 % Air Exchange Highly effective In an operating system, the H 2 O-Gate vent breather creates a moisture barrier when there is a 2 C (5 F) degree difference between reservoir and ambient temperature and when there is a 1% exchange of air volume above the fluid. 1 2 3 4 5 6 7 8 9 Air Flow, SCFM Low pressure drop across media. The P indicator triggers at P,7 bar (1 psid) (during exhalation). NOTE: Mobile systems may actuate the indicator due to vibrations, in which case the element should be changed after 5 hours of operation. 3

DIRT-Gate Element Model Code BR21 DIRT-Gate media is made of a strong graded matrix especially designed for removing airborne contamination. This media is pleated to maximize surface area (high dirt holding capacity) and provides high efficiency (99% at 2 micron) with very low pressure drop. Specifications Housing Material - ABS Plastic Temperatures - Up to 121 C (25 F) Efficiency - 99% at 2 micron Installation Dimensions mm (inches) 133,4 (5.25) Á 19 (.75) 12 (.47) 15 (4.13) Features & Benefits Rugged ABS plastic housing can be exposed to temperatures as high as 121 C (25 F), and is corrosion resistant. Visual mechanical indicator, which triggers at,7 bar (1 psid) (during exhalation). Easy installation. Lightweight design requires only hand tightening. Low pressure drop across filter media reduces stress on reservoir and system components. Plated steel core prevents filter media distortion. Pressure Drop Inches of water 3. 2.7 2.2 2. 1.7 1.2 1..7.2 1.5 UN Straight Thread Fluid Displacement l/min (USgal) 283 (75) 85 (225) 1416 (374) 1982 (524) 246 (636).75 (.18).5 (.73).25 (.36) bar (psi) 1 2 3 4 5 6 7 8 9 Air Flow, SCFM NOTE: Mobile systems may actuate the indicator due to vibrations, in which case the element should be changed after 5 hours of operation. 4

V211 and V191 Spin-on Elements V211 Series Pressure Drop 3 Fluid Displacement l/min (USgal) 284 (75) 568 (15) 852 (225) 1136 (3) 1419 (375),7 (.18) Element Model Code V211B*R3 Element length 1-184 (7.3) 2-286 (11.3) Dimensions mm (inch) V211B1R3 Breather Pressure Inches of Water 2 1,5 (.73),2 (.3) Pressure bar (psi) 286 (11.3) 184 (7.3) V211B2R3 Breather 1 2 3 4 5 Air Flow SCFM 126 (5.) See pages 5 & 6 for available adaptor options. V191 Series Pressure Drop Pressure Inches of Water Fluid Displacement l/min (USgal) 189 (5) 284 (75) 379 (1) 568 (15) 757 (2) 852 (225) 3,7 (.18) 2 1 V191B1R3 Breather V191B2R3 Breather,5 (.73),2 (.3) Pressure bar (psi) Element Model Code V191B*R3 Element length 1-147 (5.8) 2-23 (8.) 23 (8.) 147 (5.8) Dimensions mm (inch) 5 1 15 2 25 3 Air Flow SCFM 97,5 (3.84) See pages 6 & 7 for available adaptor options. 5

Spin-On Vent Filter Adaptors Models & Part Numbers Bayonet Adaptor Installation Part Number Description Vent Filters Applicable 92479 Bayonet,,4 bar (6 psi) check V211, BR11, BR21 93865 Bayonet,,2 bar (3 psi) check V211, BR11, BR21 Vent Filter 92471 Bayonet, no check V211, BR11, BR21 P-772 Threaded pipe V211, BR11, BR21 932182 Threaded pipe V191 9324 Bayonet, no check V191 Bayonet Adaptor Threaded Pipe Adaptors Installation Dimensions For V211, BR11 & BR21 Part: P-772 3rd angle projection Standard Mounting Flange of a reservoir filler/breather assembly 21,7 (.853) 19,1 (.75) 82,6 (3.25) 25,4 (1.) All Vickers Vent Filters are easily applied to reservoirs via Spin-On adaptors. For V191 Part: 9324 1 1 / 4 NPT 1 1 / 2-16 UN For V191 Part: 932182 12,7 (.5) 63,5 (2.5) 19 (.75) 1 1 / 8-16 UN Bayonet style 1 / 4 turn connection with gasket 44,2 (1.74) 54,4 (2.14) 1 1 / 8-16 UN 3 / 4 NPT Roll pin 38,1 (1.5) 63,5 (2.5) 6

Bayonet Adaptors For V211, BR11 & BR21 W/Pre-vent Part: 92479,4 bar (6 psid) Part: 93865,2 bar (3 psid) Checked exhaust,2 bar (.3 psid) intake 3rd angle projection Pre-Vent Option In a system where the fluid level drops and rises with cylinder actuation, the Pre-Vent feature minimizes the amount of air exchange through the vent filter. As the oil level drops, air enters the reservoir and is cleaned as it passes through the vent filter. As the oil level begins to rise, the pressure-vent stops the air from escaping the reservoir, and the tank becomes pressurized up to a maximum of the pressure vent setting (either,2 bar or,4 bar (3 or 6 psi)). The next time the system cycles, and the oil level drops, the air inside the reservoir will expand to make up the difference in volume. CAUTION: The reservoir tank and system must be designed to withstand a pressure of either,2 bar or,4 bar (3 or 6 psi). 1 1 / 2-16 UN Pre-Vent exhale check Inhale check Bayonet style 1 / 4 turn connection with gasket Roll pin 38,1 (1.5) 63,5 (2.5) 61,5 (2.42) 73,4 (2.89) 7,6 (2.78) Note: Max. drain port pressure for variable pumps - Pump Pressure PVH,5 bar (7 psi) PVQ,35 bar (5 psi) PVB,35 bar (5 psi) PVE,35 bar (5 psi) VVA 2, bar (29 psi) VVB 1, bar (15 psi) 92479 Pre-Vent breather adaptor Hi fluid level @,4 bar (6 psi) (pressurized) Lo fluid level @,2 bar (3 psi) Bayonet Adapter with,4 bar (6 psid) Pressure Vent bar (psi),7 (1) For V211, BR11 & BR21 Part: 92471 Inhalation cycle Flow (CFM) Note: 2 CFM = 57 l/min 2 1 1 / 2-16 UN bar (psi),56 (8) Bayonet style 1 / 4 turn connection with gasket 61,5 (2.42) 73,4 (2.89),42 (6),28 (4) Exhalation cycle,14 (2) Flow (CFM) 2 Roll pin 38,1 (1.5) 63,5 (2.5) 7

Vickers Recommended System Sampling Frequency Chart Systems with target cleanliness 17/15/12 or lower System Pressure < 14 bar (2 psi) 14-21 bar > 21 bar (3 psi) (2-3 psi) 8 hours or less operation per day 4 months 3 months 3 months Over 8 hours of operation per day 3 months 2 months 2 months Systems with target cleanliness 18/16/13 or higher System Pressure < 14 bar (2 psi) 14-21 bar > 21 bar (3 psi) (2-3 psi) 8 hours or less operation per day 6 months 4 months 4 months Over 8 hours of operation per day 4 months 3 months 2 months Initial commissioning or major rebuild Large system (2 liters (53 USgal) or more) and systems with servovalves Sample fluid before start-up Sample fluid during first day running Sample fluid after one week Sample fluid after one month operation Other systems Sample during first day running Sample after one month operation Systems in distress or immediately after a maintenance event (i.e. increased heat, erratic operation, unusual sound etc.) Immediate 8