Instruction Manual for Intrinsically Safe - Reed Switches

Similar documents
I/P Transducer Positioner Module

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

Certificate of Compliance

Installation and Operation Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

CERTIFICATE OF COMPLIANCE

AND OPERATION INSTRUCTIONS

210 Series Transmitter with External Electrochemical Sensor

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

TRYCLOPS. X Purge Controller XP Version. User s Manual

120 Series Explosion-Proof Pressure and Differential Pressure Switches

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Technical Data. Dimensions

Electro-Pneumatic Converter YT-940 SERIES

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

COMPACT METAL bender 99826

VG5 Supplementary instructions

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Part I - Installation

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Technical Data. Dimensions

Deep Submersible Level Transducer Series 300DS

Technical Data. Dimensions

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

GEMS SENSORS & CONTROLS

700 SERIES BMS II BUBBLER MONITORING SYSTEM

800 Series. 800 Series INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES

Ocean Technology Systems ComBox

PurgEx. X Purge Controller N Version. User s Manual

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

J Air and Water Kit Instructions Part# 02584

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PT-400 User Manual APG

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

! Warning, refer to accompanying documents.

Pressure switch, Differential pressure switch and Thermostat RT-E

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Technical Data. Dimensions

Magnetic level switch type MR783 Instruction Manual

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

HLM-2000-TX Gas Transmitter User Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

D Series Air and Water Kit Part# 02550

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

North American Pressure Switches

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Part I - Installation

623 Series Dome Load Regulators

Pressure switch KP-E. Data sheet

Further technical information is available on

453 Series Steam Heated Vaporizing Regulator

User s Guide Temperature Sensor Converter TSC-599

Technical Data. Dimensions

TV-114 TV-114-A Wind Speed Sensor User s Manual

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

Technical Data. General specifications. Rated operating distance s n 2 mm

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Technical Data. General specifications. Rated operating distance s n 5 mm

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

OEM Manual. MODEL ½ Digit DRUM SCALE

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Pressure control, differental pressure control and thermostat Type RT

PRESSURE SWITCHES Bulletin 8757

PRESSURE, VACUUM AND TEMPERATURE

Operating Instructions

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

92831 TEL: (714) FAX:

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

GAS FUEL VALVE FORM AGV5 OM 8-03

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

TELEDYNE HASTINGS INSTRUMENTS MODEL 40 POWER SUPPLY INSTRUCTION MANUAL

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

Orifice Plate Flow Meter

Pressure Switches Application Guideline

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Purge Gas Inlet Kits

Technical Data. Dimensions

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

RTD temperature probes

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

INSTALLATION & MAINTENANCE INSTRUCTIONS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Transcription:

Instruction Manual for Intrinsically Safe - Reed Switches Option Code: -1S2-IS-LED or -2S2-IS-LED -1S2-IS or -2S2-IS ATEX RCM Industries, Inc. Direct Reading Differential Pressure Flowmeters 110 Mason Circle, Suite D Concord, CA 94520 Telephone: 925-687-8363 Toll Free: 1-800-flo-gage (356-4243) Fax: 925-671-9636 E-mail: sales@flo-gage.com Web: www.flo-gage.com Page 1 of 12

Table of Contents Page 1. Introduction 3 2. Installation Planning 4 3. Specifications and Rating 4 4. Conduit Connection & Wiring (-1S2-IS-LED or -2S2-IS-LED) 5 5. Control Drawing #6932 6 6. Conduit Connection & Wiring (-1S2-IS or 2S2-IS) 7 7. Control Drawing #6931 8 8. Adjustment and Calibration Instructions 9 9. Hazardous Location 10 10. Intrinsic Safe System 11 11. Warranty 12 12. Declaration of Conformity Illustrations Conduit Connection & Wiring -1S2-IS-LED or -2S2-IS-LED Figure 1 Control Drawing # 6932 Figure 2 Conduit Connection & Wiring - -1S2-IS or -2S2-IS Figure 3 Control Drawing # 6931 Figure 4 Intrinsic Safety System Figure 5 Conforms to the following Standards: EN 60079-0: 2009 - Electrical Apparatus for Explosive Gas Atmospheres - Part 0: General Requirements EN 60079-11: 2007 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety i EN 60079-26: 11: 2007 - Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga Page 2 of 12

1. WARNING Failure to comply with the installation instructions provided in this manual could result in death or serious personal injury. Introduction This installation instruction manual is provided with each Flo-Gard II ordered with the following option code designation: -1S2-IS (1-single pole double throw reed switch and intrinsic safe approval) -1S2-IS-LED (1-single pole double throw reed switch, intrinsic safe approval and 1-LED). -2S2-IS (2-single pole double throw reed switches and intrinsic safe approval). -2S2-IS-LED (2-single pole double throw reed switches, intrinsic safe approval and 2-LED s). This product has been certified intrinsically safe when used with an approved barrier by the following recognized testing laboratories: Canadian Standards Association (CSA), Canada. KEMA is the issuer of the ATEX EC Type Examination Certificate. CAUTION Only qualified, service trained personnel who are aware of the hazards should perform the connection of external wiring to this product. Intrinsic Safety insures that a circuit operated under normal or specified fault conditions is not capable of causing ignition of the prescribed explosive atmosphere. WARNING Potential spark hazard impact to the enclosure must be avoided when installed in a Zone 0 hazardous area per EN 60079-0. Page 3 of 12

2. Installation Planning 2.1 Installation Planning Considerations Determine site selection and piping recommendations and damage prevention. Select a site which is convenient for viewing when ordered with the LED s and provides service access. Do not exceed the pressure and temperature limits marked on the nameplate. Ratings are determined by the effects on the bellows, elastomer seals and electronics and/or switches. Protect from freezing liquids, water hammer, surge and vibration. 3. 3.1 Cable / Conduit Recommendation Use NEC / CEC approved 20 AWG cable with 3 or 6 conductors with drain wire and CSA Certified watertight conduit or cable gland (not included). See below for cable / conduit recommendation. Specifications & Rating Recommended: Liquid Tight Strain Relief Connector & Grounding Locknut, multiconductor shielded communication cable 20 AWG 7/28, CSA, UL Certified, CE, OSHA Acceptable. Ratings: 3.2 Entity Parameters General Purpose Vmax = 28V Contact Rating 10W max Imax = 110mA Voltage 125Vac max Pmax = 1.2W 175Vdc max Ci = 0uF 0.35 Amp max switching Li = 0uH Current 1.5 Amp max carry Hysteresis 13% F.S. 3.3 LED Rating: Voltage 0.50 Watts Metal Film Resistor 24V, 20mA Rating based intrinsic safe approvals (Entity Parameters) and manufacturer specifications (General Purpose). Page 4 of 12

5. Conduit Connection & Wiring 5.0 Conduit Connection and Wiring (Flo-Gage) -1S2-IS-LED or -2S2-IS-LED Important: Terminate shield inside outer housing but outside inner shield housing. Refer to Figure 1 for details. Select one of the following connection methods based on the option designation. 24Vdc power supply required (Option PS-24), not included. See control drawing # 6932 for details. Connection for Switch # 1 (-1S2-IS-LED) 5.1 Connect the positive wire from 24Vdc power supply to terminal #1 (+ 24Vdc). 5.2 Low (Normally Closed Contact) Connect Common (-) to terminal # 2 or Low (Normally Open Contact) Connect Common (-) to terminal # 3. Connection for Switch # 2 (-2S2-IS-LED) 5.3 Connect the positive wire from 24Vdc power supply to terminal #1 (+ 24Vdc). 5.4 High (Normally Closed Contact) Connect Common (-) to terminal # 2 or High (Normally Open Contact) Connect Common (-) to terminal # 3. Refer to Figure 1 for details on connecting and setting switches. RCM Industries, Inc. 110 Mason Circle Suite D Concord, CA 94520-1238 Intrinsically Safe Per DWG 6932 C US 09 2151967 X Ex ia IIC T 4 Zone 0 Class I, Groups A,B,C,D Class II, Groups E,F,G II 1 G 0 C Ta +50 C KEMA 10 ATEX 0021 X PH : 925-687 -8363 www.flo -gage.com Hazardous Location Labels Option Code -1S2-LED-IS or -2S2-LED-IS Figure 1 Page 5 of 12

5. Control Drawing #6932 Figure 2 Page 6 of 12

6. Conduit Connection & Wiring 6.0 Conduit Connection and Wiring (Flo-Gard II) -1S2-IS or -2S2-IS Important: Terminate shield inside outer housing but outside inner shield housing. Refer to Figure 1 for details. Select one of the following connection methods based on the option designation. See control drawing # 6931 for details. Connection for Switch # 1 (-1S2-IS) 6.1 Low (Normally Closed Contact) Connect (COM) terminal #1 and (NC) terminal #2 or Low (Normally Open Contact) Connect (COM) terminal #1 and (NO) terminal #3. Connection for Switch # 2 (-2S2-IS) 6.2 High (Normally Closed Contact) Connect (COM) terminal #1 and (NC) terminal #2 or High (Normally Open Contact) Connect (COM) terminal #1 and (NO) terminal #3. Refer to Figure 2 for details on connecting and setting switches. RCM Industries, Inc. 110 Mason Circle Suite D Concord, CA 94520-1238 C US 09 2151967 X Intrinsically Safe Per DWG 6931 AEx ia IIC T 4 Zone 0 Class I, Groups A,B,C,D Class II, Groups E,F,G PH : 925-687 -8363 www.flo -gage.com II 1 G 0 C Ta +50 C KEMA 10 ATEX 0021 X Figure 3 Page 7 of 12

6. Control Drawing #6931 Figure 4 Page 8 of 12

Adjustments Adjustments are made by rotating the adjustment screw clockwise to raise the set point or counterclockwise to lower the set point. Use the Green mark on the adjustment disc as a reference. Factory set at 30% of full scale for switch #1 and 95% of full scale for switch #2. Important: Rotating clockwise moves the set point upscale. See chart below for % of full scale setting. To set switches accurately, connect a continuity tester to common and the selected normally open or normally closed contact. Establish flow at the desired set point and turn the adjustment screw until switching occurs. Increase and decrease the flow rate and verify desired set point switching. Adjustment Screw Turns % of Full Scale 0 (factory setting) 30 1/2 60 1 80 1 1/2 90 2 100 Calibration Procedure: Re-calibration of the switches can be performed in the field using a continuity tester, multimeter with buzzer or indicator light. Normally Open Contacts: When wired using to the N.O. (Normally Open Contact) turn the adjustment screw clockwise until the switch stops, the light should be ON. Turn the adjustment screw counterclockwise until the light goes OFF, continue turning the screw until the light just comes ON again and stop. Turn the adjustment screw clockwise until the green dot (reference mark) is facing 3:00 o clock (closest to the terminal strip). The light should be OFF this is approximately 30% of the full scale flow rate. Important: Rotating clockwise moves the set point upscale. Page 9 of 12

Normally Closed Contacts: When wired using to the N.C. (Normally Closed Contact) turn the adjustment screw clockwise until the switch stops, the light should be OFF. Turn the adjustment screw counterclockwise until the light comes ON, continue turning the screw until the light just goes OFF again and stop. Turn the adjustment screw clockwise until the green dot (reference mark) is facing 3:00 o clock (closest to the terminal strip). The light should be ON this is approximately 30% of the full scale flow rate. Important: Rotating clockwise moves the set point upscale. Repeat the above procedures when ordered with two switches (2S2 Option) refer to the adjustment chart 2.0 for the number of turns required to obtain 90% of the full scale flow rate. Replace the cover and secure using 4 #6-32 flat head screws. Hazardous Location The RCM Flo-Gard with the -1S2 or -2S2 switches are listed as Intrinsically Safe for Hazardous Locations. This means that the circuits within these flow meters are designed to be incapable of producing a spark or thermal effect that could ignite a mixture of flammable or combustible gases when properly installed in accordance with Hazardous Location requirements. It does not mean that these flow meters are Explosion Proof. If proper safety precautions are not followed, or if the equipment is not installed properly, there is a serious potential for explosion. Be sure to review all safety precautions, installation, and wiring practices throughout this manual. DANGER Although some RCM products are designed and certified for installation in hazardous locations as defined by the National Electrical Code, many RCM products are not suitable for use in hazardous locations. It is the responsibility of the individuals who are installing the products in hazardous locations to determine the acceptability of the product for the environment. Additionally, to ensure safety, the installation of instrumentation in hazardous locations must be as per the manufacturer's control drawing specifications. Any modification to the instrumentation or the installation is not recommended and may result in life threatening injury and/or damage to facilities. Page 10 of 12

Intrinsically Safe Installation Requirements It is important that the installer of an Intrinsically Safe system reference the requirements of the authority having jurisdiction at the installation site. In the United States, reference should be made to Article 504 of the National Electric Code and ANSI/ISA RP 12.6. RCM flow meters that are approved intrinsically safe should be installed in accordance to these requirements and in accordance with the approved control drawings in the manual. CAUTION In order to have a fire or explosion, fuel, oxygen and a source of ignition must be present. An intrinsically safe system assumes the fuel and oxygen is present in the atmosphere, but the system is designed so the electrical energy or thermal energy of a particular instrument loop can never be great enough to cause ignition. Intrinsically Safe System Intrinsically safe apparatus never stand alone. Generally, it is part of a system in which the certified components are used to guarantee the safety of the system. A simplified schematic of an intrinsically safe system is shown below in figure 4. Figure 5 Page 11 of 12

Warranty Our products are guaranteed to satisfy period. Products may be returned within 30 days of receipt without restocking charges. (Expediting and freight charges are not refundable.) After the initial 30 day trial period, any returned merchandise, unless defective as defined in the Warranty, will be subject to a 20% restocking charge. Merchandise may be returned only with the permission of RCM Industries, Inc. Merchandise returned for credit is to be shipped with transportation charges prepaid. Credit allowed will be determined by the condition of merchandise returned. This credit can only be applied to future orders or to accounts outstanding at the time of issue of the credit memorandum. Prices and discounts are subject to change without notice. These terms and conditions supersede all previous terms and conditions. RCM Industries, Inc. warrants the equipment manufactured by it to be free of defects in material and workmanship for a period of one year from shipment. RCM will repair or replace, at its option, any equipment which it determines to contain defective material or workmanship and will return said equipment to the purchaser, FOB factory shipping point. RCM Industries shall not be obligated to repair or replace equipment which has been repaired by others, abused, improperly installed, altered, or otherwise misused or damaged in any way. RCM Industries shall not be responsible for any dismantling, reassembly or reinstallation charges. This warranty is in lieu of all other warranties, expressed or implied, and Buyer hereby waives all other warranties, guaranties, conditions or liabilities, expressed or implied, arising by law or otherwise (including without limitation any obligation of Seller with respect to any special, indirect, incidental or consequential damages, including damages claimed in connection with any rescission of this agreement by Buyer) and whether or not occasioned by Seller s negligence. Specification may change without notice. The information we supply is believed to be accurate and reliable as of printing. However, we assume no responsibility for its use. While we provide our customer with applications assistance through our literature and web site, it is up to the customer to determine the suitability of our products in a given application. Contact our factory if you have questions regarding these terms and conditions at 1-800-flo-gage (356-4243) or www.flo-gage.com. RCM Industries policy is to provide products and service which meet or exceed the expectations of our customer and all established requirements. Our mission is to serve industrial and commercial customers with flow measuring products which are rugged and reliable, and easy to apply, and provide outstanding service and delivery commitments which are as reliable as our products. Page 12 of 12