inflatables pfd s ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

Similar documents
ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

INFLATABLE PFD S INSTRUCTIONS FOR ANNUAL SERVICE AND SELF INSPECTION

The Service label can be found

CREWFIT 165 SPORT. self care and maintenance manual

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

MANUAL/AUTOMATIC - INFLATABLE PERSONAL FLOATATION DEVICE

MANUAL - INFLATABLE PERSONAL FLOATATION DEVICE

INSTRUCTION MANUAL. Featuring - Quick Burst Zipper Survival Operations Specialist SOLAS (74/96) Approved Lifejacket

Service Manual. Mullion Hi-Rise 275N SOLAS dot twin chamber lifejacket with Hammar hydrostatic mechanism.

SMA1060 OWNERS MANUAL

Personal Flotation Devices (PFDs) Lifejackets & Buoyancy Aids - The Facts

Owner s Manual. MD3196 and MD3091 Compact Tactical Life Preservers. *Shown with the MA3090 Chest Belt/Crotch Strap Assembly

Hammar LifeJacket Inflator

PFD 1 275N INFLATABLE JACKET

Rapid Survival System

Inflatable PFD Owner s Manual

SOS DAN BUOY DON T BE SECOND BEST INSTRUCTION MANUAL WHEN THE SECONDS COUNT READY TO GO MAN OVERBOARD RESCUE MARINE DESIGNED BY SOS MARINE, AUSTRALIA

INFLATABLE PFDs. MD2010 Manual Inflation Model. MD2012 Manual with Automatic Backup Inflation Model

THIS CARD IS MAINTAINED TO PROVIDE PROCEDURAL TEXT ONLY AND IS NOT REPORTED TO ACMS

Owner s Manual. MD3085 Inflatable PFD Manual Inflation Model Recreational: USCG Approved Type III Uninspected Commercial Vessels: USCG Approved Type V

MD5183 ELITE INFLATABLE PFD

SMA2100 Series CONSTANT WEAR LIFE PRESERVER VEST (CWLP) SMA2160 OWNERS MANUAL

Inflatable Personal Flotation Device (PFD) OWNER S MANUAL

M.E.D. / S O LA S TWO YEARS GUARANTEE SIZE kg SIZE kg. to M.E.D./SOLAS MSC 200 (80) and EN ISO ART NO 2105 EN ISO

OWNERS MANUAL FOR MODEL TD2401 Inflatable Throwable Device (Type IV PFD).

WE SAVE LIVES FOR A LIVING

DO NOT REMOVE PRIOR TO SALE MD1250

FOR MODEL NUMBERS MD2981 (MANUAL) / MD2983 (AUTO) OWNER'S MANUAL DLX 38 INFLATABLE PFD

SURVIVOR SERIES AIRCREW FLOTATION VEST PACKING INSTRUCTIONS

AUXILIARY ACR PLB Monthly Inspection and Test For use by Auxiliary members issued ACR PLBs within District Eleven North Revised Jan 2016

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model No. 1212

Inflatable Personal Flotation Device (PFD)


MD2014 INFLATABLE PFD Manual Inflation Model USCG APPROVALS: RECREATIONAL: TYPE III UNINSPECTED COMMERCIAL VESSELS: TYPE V

LPU- 40 Flotation Collar

The same as the 3005 but with integrated safety harness. Double nonmagnetic

COMFORT MAXTM BELT PACK

AirForce Owner s Manual MD3031 Manual with Automatic Backup Inflation Model

ALPS Flotation Collar. User s Manual

CBP LPU- 40 Flotation Collar User s Manual

Owner s Manual RESCUE STICK TM MRD100 THROWABLE EMERGENCY RESCUE INFLATABLE

FLOTATION CLOTHING STANDARDS IN CANADA ITS SESSION ~ OCTOBER 7, 2014

more information please contact us

Rescue Services Life Raft Manual

Owner's Manual SMA2000 Series

OWNER'S MANUAL EP 38 HYDROSTATIC INFLATABLE PFD WITH HARNESS

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model 24MSPT-1

MD1250 TACTICAL INFLATABLE SIDE POUCH LP

Owner s Manual. MD3184 Inflatable PFD Hydrostatic Inflation Model - Manual with Automatic Backup with Harness Recreational: USCG Approved Type V

INFLATABLE LIFE JACKET BASICS Stu Soffer, N-MS

Sea Rebel Kayak Owner s Manual

Owner s Manual. MD Inflatable Vest with LIFT TM Hydrostatic Inflation Model - Manual with Automatic Backup

ALSO AVAILABLE WITH HAMMAR VALVE ALSO AVAILABLE WITH HAMMAR VALVE

DO NOT REMOVE PRIOR TO SALE! Model Nos or 6340 OWNER S MANUAL HIGH WEARABILITY TYPE V USER ASSISTED INFLATABLE BELT PERSONAL FLOTATION DEVICE

Operation Manual Guillotine Cutter RC-5

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model 33M42-V17

MD3183 / Hydrostatic Inflation Model / Manual with Automatic Backup USCG Approvals: Recreational: Type II Uninspected Commercial Vessels: Type V

Personal Flotation Collar (PFC-1)

LEAK SEALING SYSTEMS

IMMERSION SUIT MAINTENANCE GUIDE IMMERSION SUIT MAINTENANCE GUIDE 1409 SERIES. SCMG003A Maintenance Guide - Immersion Suits USA ENGLISH.

McMurdo S20 & Kannad Marine R10 AIS MOB Devices

Anchor Harness Instruction Manual

INDUSTRIAL LIFEJACKETS SWEDEN

MAINTENANCE PROCEDURE FOR X 650

industrial lifejackets sweden

T3200 TransPlate Harness

INFLATABLE PFD s THE SEQUEL Stu Soffer, N-MS

isup MANUAL THANK YOU FOR PURCHASING A KAHUNA isup, WE HOPE YOU HAVE MANY YEARS OF PADDLING ENJOYMENT.

PFD GUIDANCE FOR COMMERCIAL FISHING RNLI A518pp Booklet V7.indd 1 26/04/ :49

AP100 AUTO AIR. User Instruction Manual

M.E.D./SOLAS LIFEJACKETS INFLATABLE LIFEJACKETS

Safety & Survival Catalog

Ships and marine technology Servicing of inflatable life-saving appliances

NORTHERN DIVER PFD MANUAL

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

Product Name: Hold Me Rope Anchor

Rescue Pro PFD User Manual

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

Fruity Chutes Hawk CO2 Release Valve

RG2200 BC Integrated Octopus

Step By Step How to Establish, Manage and Implement a Fall Protection Program

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

IRATA International code of practice for industrial rope access. Part 3: Informative annexes Annex H: Equipment inspection checklist

Aqua Jump Eclipse Bongo 20 (Models AJ150/AJ200 and Bongo 20) Anchor Harness Instruction Manual

Navaro Buggy Instruction Manual INSTRUCTION BOOKLET

Tactical Flotation Support System (TFSS) User s Manual

Nanofold Highchair Instruction Manual

TOOL BOX 031- SERVICE OF CARTRIDGE EXTINGUISHERS

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50. User manual English

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL

INDOOR CYCLING BIKE SF-B1110 USER MANUAL

Inflatable Dock Slide Owner s Manual

Product Information News

BELT DRIVE PREMIUM INDOOR CYCLING BIKE SF-B1509 USER MANUAL

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

SURFACE SUPPLIED HARNESS

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50 READ CAREFULLY. YOUR COMFORT AND SAFETY IS WORTH MORE THAN 15 MINUTES.

Transcription:

inflatables pfd s ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

inflatables pfd s ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS It is recommended that an accredited service agent conducts a full inspection of your PFD every third year. Read/Print this owner s self-inspection manual in conjuction with Owner s Manual 1. Read the following instructions carefully. If you require any assistance regarding self-servicing of your inflatable PFD you are advised to contact one of our accredited service centres for advice. The self-service instructions are for Marlin manufactured PFD s for recreational use only not for commercial. If PFD is used commercially, servicing should only be by an authorised accredited service centre every 12 months. 2. The green firing indicator located on the side of the CO2 inflation mechanism will be broken, ensure you have purchased green firing indicators before starting, as well as CO2 cylinders and automatic cartridge/ bobbins. Bobbin should not be older than 3 years - all these parts are available through Marlin retailers or authorised certified service centres. 3. Always use the Marlin self-inspection certificate to maintain a record of the inspection/service. WARNING: If a component fails any of the inspection steps or indeed the PFD fails to operate - the PFD must be replaced or the faulty component replaced before further use. In this circumstance the PFD must be sent to Marlin authorised accredited service centre for further tests to be conducted. WARNING: You must not repair any part of the PFD during inspection/service. Inspection 1: 1.1 General Visual Inspection a. No wear or damage to the outer cover of the PFD b. Outer cover closure is not working (zipper if applicable or hook/loop) c. No damage to webbing straps d. Buckle operation is correct (open and close buckle) e. Load indicator thread is not broken if applicable 1.2 Open outer cover and check a. Oral inflation tube has no damage. b. Whistle (Blow to check operation) c. Grab strap no visual damage d. Retro reflective tape is firmly attached and not damaged. 1.3 Models fitted with integral safety harness check that all harness components have no visible damage or excessive wear. a. Check webbing b. Stainless steel buckles c. Stainless steel D-Ring d. Stitching e. Load indicator for broken stitch f. Grab strap g. Whistle attachment h. Crotch strap/holding down strap Page 1

Inspection 2: 1.1 Inspection of the Bladder a. Open cover and inspect bladder has no signs of excessive abrasion or wear. Pay extra attention to folds and area around inflation systems. b. Inflate bladder by using red oral tube. leave the inflatated PFD 12hrs in a room with stable temperature of around 20C. If the temperature goes down overnight, this will affect pressure. Check there is no loss of pressure and no visible damage to the bladder. 12h If the bladder is damaged or the pressure falls, the PFD must be replaced or sent to an accredited service station for further tests. Under no cicumstances must you attempt to repair the PFD. Inspection of mouth inflation tube and its valve. Check mouth inflation tube and valve operate correctly. Deflate the life jacket by inverting the cap and placing the tab onto the top of the mouth inflation tube. Press cap gently to expel air. When PFD is fully deflated replace cap to normal position.do not put anything other than the inverted cap down the oral inflation tube to deflate as foreign objects may damage the valve. Page 2

Inspection 4: Inspection of CO2 Cylinder. Check that correct type/size of CO2 cylinder is fitted to the inflation head (size is printed on the bladdder near inflation head or the cylinder/inflation head protective cover). Remove the CO2 cylinder by unscrewing it counter clockwise and inspect thoroughly. it should be intact with no rust or corrosion. Replace the cylinder if the end cap has been pierced, it is damaged or the cylinder exhibits signs of rust or corrosion. If the CO2 cylinder is serviceable check weight of the cylinder on a kitchen or letter scales to ensure that the weight of the cylinder corresponds to the minimum gross weight engraved on the cylinder, (GR.WT) +/- 2 g. If the weight is incorrect or the cylinder is in any way defective it must be replaced. (A replacement cylinder should also be checked in the same manner). Record engraved GR.WT. and actual weight of cylinder on your self inspection certificte. NB! Make sure that all scraped CO2 cylinders are disposed of at once. Inspection 5: With the C02 cylinder removed, pull the manual lanyard sharply to ensure that the lever moves freely, and that the piercing cutter appears undamaged. If the lever moves freely and the piercing cutter appears undamaged, rearm the inflation head by folding back the lever into the normal position and secure with a new green firing indicator clip. If the inflation head does not operate properly, or if you are concerned about the operation of the mechanism, you must send the PFD to an accredited service agent for inspection and further action. United Moulders Halkey Roberts Page 3

Inspection 6: Inspection and rearming of automatic inflation head (automatic models only) Cartridge or Bobbin (as applicable) must be replaced if it has been immersed in water, is past its expiry date or if the expiry date falls before PFD s next scheduled service. a. For automatic models fitted with United Molders automatic inflation head with water sensing cartridge (Fig 1) UML cartridge has 3 year lifespan and is printed with an expiry date. 1. Unscrew the cartridge turn counter clockwise. 2. Check that the cartridge is clean and completely dry. 3. Record the expiry date printed on the cartridge on the inspection certificate and check that the green indicator is in place. Discard and replace cartridge if expiry date falls within next 12 months or green indicator at base of cartridge is not visible. 4. Rearm by screwing cartridge clockwise onto base of inflated head. Ensure thread is not obstructed and tigthen firmly using light hand force only. Ensure that the green auto firing indicator (at base of cartridge) is present on any auto cartridge fitted to the inflator head. Fig 1. United Molders automatic inflation head. b. For automatic models fitted with Halkey Roberts automatic inflation head with transparent cartridge and water sensing bobbin (Fig 2.) The Halkey Roberts Bobbin has a lifespan of three years and is printed with the date of manufacture. Calculate when replacement bobbin is due. There are two different formats for the date. Example 0650 denotes year 2006 on the 50th day. Alternatively Feb 19 06HRC, denotes the 19th of February 2006. In recreational use the bobbin must be replaced no later than the third year from its manufacturing date. 1. Check if green indicator is showing at the base of head. Remove the bobbin by unscrewing the transparent cartridge counter clockwise. Discard bobbin if expiry date (see paragraph above) falls within next 12 months or green indicator at base of transparent head is not visible when armed. To rearm the Halkey Roberts automatic inflation head. 2. Fit the bobbin (the bobbin will only fit one way round). 3. Refit transparent cartridge by screwing it clockwise until hand tight. 4. Check that the green firing indicator is visible. Fig 2. Halkey Roberts automatic inflation head The water sensing bobbin is inside the transparent cartridge Page 4

Inspection 7: Refitting the CO2 Cylinder a. Ensure that CO2 cylinder has passed inspection (Refer Instruction 4) b. Ensure that the inflation head has passed inspection and rearmed (Refer Instruction 5) c. Ensure that automatic cartridge has passed inspection and is rearmed. (Refer Instruction 6) d. Hold the unit firmly and screw the CO2 cylinder clockwise into top of the inflator head. Hand tighten until firm. DONOT USE ANY TOOL OR UNDUE FORCE Warning: When replacing with a new CO2 cylinder the new cylinder should be inspected as per Instruction 4. For the piercing cutter to work correctly both the CO2 cylinder and automatic cartridge (when fitted) must be firmly hand tightened onto inflation head. Inspection 8: Record service inspection on your PFD. If the PFD has passed all applicable self inspection instructions described in Instructions 1 through 7, using permanent laundry marker Sign and date the Service Inspection label located on the inflation head side of the PFD bladder. Format for dating a self inspection should be SI-YY-MM (the prefix SI is to indicate self inspection) For example for a self inspection completed in August 2010 service schedule should show SI-10-08 Inspection 9: Repack PFD. repack the PFD according to model instructions as described in your PFD owners manual. make sure the manual pull lanyard is not tangled and that the lanyard knob is hanging outside the PFD cover. Inspection 10: Certify PFD inflatable Self Inspection Certificate Sign self inspection certificate and record the date self inspection was completed. It is also recommended that the next inspection due date is noted in space provided and that the signed and dated certificate is placed in boat s safety equipment log for future reference. Page 5

MARLIN INFLATABLE PFD ANNUAL SELF INSPECTION CERTIFICATE Applicable for inflatable PFD s in recreational use only Before you start please read Marlin Annual Self Inspection and Service Instructions. Record each inspection instruction as described in the steps on the this certificate as it is completed. If the PFD or a component of the PFD fails any of the checks listed in Instructions 1-6 the PFD or the faulty component must be replaced before further use, alternatively the PFD should be sent to an accredited service agent for further inspection. Under no circumstances must you attempt any repairs yourself. Product PI No: Or Serial No: Model Last serviced date or date of purchase if no service YY MM Check Status at each Instruction by marking box Inspection 1 1.1 General visual inspection 1.2 Open outer cover and check 1.3 Harness component Inspection 2 2.1 Check bladder for abrasion wear 2.2 Performed bladder leakage test Inspection 3 3.1 Operation of mouth inflation tube and valve Pass - YES NA - Not Applicable Fail - NO Inspection 4 4.1 CO2 Cylinder for damage or corrosion 4.2 Check weighed cylinder Record engraved GR.WT Actual Weight Inspection 5 5.1 Operation of inflation head and secured new firing indicator clip Inspection 6 6.1 Expiry date and green indicator is in place United Moulders 6.2 Expiry date and green indicator is in place Halkey Roberts Inspection 7 7.1 Refit inspected or new CO2 Cylinder (Refer Instruction 4) Inspection 8 8.1 Sign and date PFD service schedule attached to PFD Inspection 9 9.1 Repack PFD (Refer: Owners Instructions manual supplied with PFD) Inspection 10 I hereby certify that this PFD has been inspected and serviced in accordance with the Marlin Annual Self Inspection and Service Instructions describe in Instructions 1 through 9. Next Inspection Due Name Signature Date Address