Autocalibration Systems For In Situ Oxygen Analyzers

Similar documents
Autocalibration Systems for In Situ Oxygen Analyzers

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

780S Ultra High Purity Series

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

GAS FUEL VALVE FORM AGV5 OM 8-03

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Zirconia Oxygen Analyzer Systems

Oxymitter 4000 Hazardous Area Oxygen Transmitter

Features. Description

BUBBLER CONTROL SYSTEM

Design Features. General Description

analytical bulk flow distance FLOW level pressure temperature industrial communication

Royce Interface Level Analyzer and Sensors

BUBBLER CONTROL SYSTEM

Pro-V Multivariable Flowmeter

PRODUCT CONFORMITY CERTIFICATE

Ultra High Purity Model 780S

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Model EXAxt AV550G. Averaging Oxygen Analyzer

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pneumatic high-pressure controller Model CPC7000

Steel-Mass Model 640S

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

For Multi-Parameter Meters see mvx

Pneumatic high-pressure controller Model CPC7000

RCD - Ultra-Rugged Differential Pressure Flowmeter

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

SSL. Smart Valve Positioner.

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Valve Proving System VDK 200 A S06*

Tightness controls TC 1 3 and TC 4

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Best Practice Guide, Servomex 2700

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Manual Oxygen Analyzer A4009T

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Level transmitter LT 100

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Valve Proving System VDK 200 A S02

Torque Tube TB300 Digital Transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ30 Combustion oxygen monitor

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

TH-1800-T TRX-700-CNG Converter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ20 oxygen monitor Combustion gas analysis

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

SSR. Smart Valve Positioner.

For Multi-Parameter Meters see mvx

Steel-Mass Model 640S

SPECIFICATIONS ATTENTION

Columbus Instruments

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

OXYGEN MONITORING SYSTEM OMS

Porter Analytical & Industrial Products

Z, Y, and X PURGE INDICATORS / CONTROLLERS

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Orifice Plate Flow Meter

Mass Flow Controllers

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

User and Installation Manual

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

DTG - LCD Digital Temperature Gauge USER MANUAL

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

High-performance submersible pressure transmitter For level measurement Model LH-10

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Instruction Manual. Analyser AMS for AMS ZrO 2 - Probes

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Automatic Valve Proving Control

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

9700 Transmitter Submersible hydrostatic level transmitter

Electropneumatic Transducer (I/P) Installation, Operation and

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Section GAS CHLORINATION SYSTEM

HYDRA-line. HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG. Pressure Systems. Applications. Special features. Description

Industrial pressure controller Model CPC4000

ACV-10 Automatic Control Valve

Technical Data Sheet MF010-O-LC

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

Transcription:

Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from one to four oxygen analyzers Unique Single Probe Sequencer can be mounted directly to Oxymitter 4000 Can be easily added to existing O 2 installations HART digital communications offers remote calibration Autocalibration systems take full advantage of unique Oxymitter 4000 Calibration Recommended diagnostics; ensures Oxymitter 4000 is always in calibration SPS 4000 Autocalibration Sequencer is ideal in applications of one or two oxygen probes IMPS 4000/MPS 3000 Autocalibration Sequencers are ideal in applications of up to four oxygen probes KEEPS YOUR ANALYZERS IN CALIBRATION; KEEPS YOU OFF THE DUCT An oxygen flue gas analyzer is one of the few industrial instruments which enables a calibration standard to be permanently piped to the instrument. Most instruments that measure pressure, flow, or temperature require that a calibration standard be brought to the instrument or that the instrument be taken to the calibration source, usually located in the instrument shop. Automatic calibration systems have been utilized with in situ oxygen flue gas analyzers for years with success. However, the introduction of the Rosemount SPS 4000 Single Probe Autocalibration Sequencer and the IMPS 4000 Multiprobe Autocalibration Sequencer, coupled to the unique features of the Rosemount Oxymitter 4000 and World Class 3000 Analyzers, makes autocalibration for in situ oxygen analyzers an invaluable operations tool. Plant personnel often ask how often an oxygen analyzer requires calibration. The answer is very applicationdependent, based upon the fuels being burned, normal levels of oxygen, and the sulfur content in the flue gases. The Oxymitter 4000 address this concern by providing an on-line diagnostic that determines when a calibration should be conducted. Once every hour, the Oxymitter 4000 initiates an on-line impedance measurement of the sensing cell which directly correlates to cell accuracy. This feature will trigger a fully automatic calibration via the SPS 4000, ensuring that the analyzer is always accurate. Also, many needless calibrations based on time in service are eliminated. A contact closure notifies the control room when a calibration is taking place. Oxygen output signal can be held at last value, or released during calibration. Both Oxymitter and World Class products can also initiate calibrations by traditional methods. Contact closure from the user s control room Time since last calibration feature established by the autocalibration system Oxymitter 4000 has a button on the front panel of the electronics to initiate calibration HART Communications or Asset Management Solution

SPS 4000 AND IMPS 4000 AUTOCALIBRATION SYSTEMS FEATURES AND BENEFITS FEATURES Flexible installation allows SPS 4000 to be installed as either an integral component to the Oxymitter 4000 or as a remote component to your Oxymitter or World Class 3000 analyzers. Both SPS 4000 and IMPS 4000 can initiate autocalibration based on a contact created by the Calibration Recommended feature of the Oxymitter 4000 Oxygen Transmitter. Both SPS 4000 and IMPS 4000 are enhancements to the HART digital communications when used with Oxymitter 4000 and World Class 3000 Analyzers. Both SPS 4000 and IMPS 4000 are enhancements to the Fisher-Rosemount Asset Management Systems (AMS) capability. BENEFITS Enables the user to minimize installation costs and maximize human and material resources. Combination of this patented feature coupled with autocalibration eliminates the need for a maintenance or service person to ever manually calibrate the analyzer on the flue duct. Needless calibrations are eliminated. The use of HART communications coupled with an autocalibration system enables the user to set up, calibrate, and troubleshoot an oxygen analyzer from any location where the analyzer s 4-20mA signal is terminated and accessible. The ability to view and diagnose Oxymitter 4000 or World Class 3000 Oxygen Analyzers from a single console coupled to an autocalibration system enables the user to initiate and perform analyzer calibration from the control room. ROSEMOUNT ANALYTICAL AUTOCALIBRATION SYSTEM INSTALLATION OPTIONS OXYMITTER 4000 WORLD CLASS 3000 INTEGRALLY MOUNTED SPS 4000 A (1 PROBE) INTEGRAL OR REMOTE IMPS 4000 (1 TO 4 PROBES) REMOTE MOUNTED SPS 4000 B (1 PROBE) (EXPLO VERSIONS MUST BE REMOTE MOUNTED) MPS 3000 (1 TO 4 PROBES) Page 2

SPS 4000 SINGLE PROBE SEQUENCER The SPS 4000 is specifically designed for users who mount only one or two in situ oxygen flue gas analyzers to each combustion process. The SPS 4000 is a new arrangement which can be mounted directly to the Oxymitter 4000 Oxygen Flue Gas Transmitter. It can also be mounted at a location remote from the Oxymitter 4000 or World Class 3000 probe. The SPS 4000 can also be used with previously installed Oxymitter 4000 and World Class 3000 Analyzers. The figure on page 2 shows both the integral-mounted and the remote-mounted arrangements for the SPS 4000 Single Probe Autocalibration Sequencer. The SPS 4000 utilizes a manifold block that serves three functions: 1. Calibration gases are piped into and sequenced through solenoids mounted on the manifold. 2. The manifold provides a mounting platform for the circuit card and terminations 3. Electrical feedthroughs are drilled into the manifold The SPS 4000 can be provided in either an integral or remote installation. Reference air regulator and rotometer are optional. Test gas bottles which will provide three to five years of service in normal operation can also be included as an option. The SPS 4000 can be provided with either Teflon tubing and brass fittings or stainless steel tubing and fittings depending on the application. The Oxymitter 4000 utilizes its one contact output signal as a handshake interface with the SPS 4000 which fires the solenoids to introduce test gas to the probe. Additional alarm contacts to the user s control room are also provided by the SPS 4000 system: 1 cal initiate input contact per probe 1 in cal output contact per probe 1 cal failed output contact per probe (Includes cal gas pressure low) SPECIFICATIONS Mounting: Integral to Oxymitter 4000 Remote from Oxymitter 4000 Materials of constructions: Manifold/electronics encl.: Aluminum Mounting brackets: 316 stainless steel Pneumatic fittings: 1/8 in. brass NPT (SS optional) Pneumatic tubing: 1/4 in. Teflon (SS optional) Assembly hardware: galvanized and stainless steel Humidity range: 100% Relative humidity Ambient temperature range: -40 o to 149 o F (-40 o to 65 o C) Electrical classification: NEMA 4X (IP56) Electrical feedthroughs: 1/2 in. NPT Input power: 90 to 250V, 50/60Hz Power consumption: 5VA max External electrical noise: EN 50 082-2, includes 4KV electrostatic discharge Handshake signal to/from Oxymitter (self-powered): 5V (5mA Max) Cal. initiate contact input from control room (1 per probe): 5VDC (self-powered) Relay outputs to control room: 5 to 30VDC, Form A (SPST) (1 In-Cal, 1 Cal Failed ) Cabling distance between SPS 4000 and Oxymitter Electronics package: Maximum 1000 ft (303 m) Piping distance between SPS 4000 and probe: Maximum 300 ft (91 m) Approximate shipping weight: 10 lbs (4.5 kg) Fisher-Rosemount has satisfied all obligations coming from the European legislation to harmonize the product requirements in Europe. Page 3

Page 4 SPS 4000 A MOUNTING DIMENSIONS - AS INTEGRALLY MOUNTED TO OXYMITTER 4000 PROBE

REMOTE MOUNTED SPS 4000 B MOUNTING DIMENSIONS 0.94 (23,88) 0.94 (23,88) 1/8 NPT HIGH CAL GAS IN 1/8 NPT LOW CAL GAS IN 1/8 NPT TO TEST GAS FLOWMETER TEST GAS FLOWMETER (TEST GAS OUT TO ANALYZER) 9.00 (228,60) REFERENCE AIR FLOWMETER (OPTIONAL) (REFERENCE AIR OUT TO ANALYZER) 1/2 NPT REMOTE CONTACT INPUT/ STATUS INDICATOR OUTPUT CONDUIT CONNECTION 2.00 (50,80) 11.88 (301,75) 4.25 (107,95) 14.00 (355,60) 1/2 NPT WORLD CLASS 3000 ELECTRONICS CONDUIT CONNECTION 2.00 (50,80) CLEARANCE TO REMOVE COVER INSTRUMENT AIR IN (OPTIONAL) 1/2 NPT LINE VOLTAGE CONDUIT CONNECTION 5.00 (127,00) 1/2 NPT CONDUIT CONNECTION FOR OXYMITTER 4000 LOGIC I/O SIGNAL NOTE: DIMENSIONS ARE IN INCHES WITH MILLIMETERS IN PARENTHESES. Page 5

SPS 4000 ORDERING INFORMATION SPS 4000 A Integrally Mounted to Oxymitter 4000 The information in the table below should be included in the matrix selection for the Oxymitter 4000. REFERENCE AIR SET (1) FITTINGS/TUBING OXYMITTER MOUNTING ENCODE ENTRY NO YES BRASS/TEFLON STAINLESS STEEL HORIZONTAL VERTICAL 03 X X X 04 X X X 05 X X X 06 X X X 07 X X X 08 X X X 09 X X X 10 X X X SPS 4000 B Mounted Remote from an Oxymitter 4000 or World Class 3000 Probe SPS 4000 B Autocalibration System for Oxymitter 4000 and World Class 3000 Oxygen analyzer systems. Mounted separate from the probe. SPS 4000 Autocalibration System - Instruction Bulletin Code Oxygen analyzer system 10 Used with World Class 3000/IFT system (remote mounted only) 20 Used with Oxymitter 4000 system (remote mounted only) Code Reference Air 1 No reference air required (1) 2 Reference air provided Code Fittings and Tubing (2) 1 Brass Fittings, Teflon Tubing 2 Stainless Steel Fittings and Tubing Code Electrical Classification 10 NEMA 4X 20 Hazardous Area Classifications - Cenelec EExd IIB + H2 - PENDING (3) 30 Hazardous Area Classifications (Class I, Div. I, Group B,C,D) - PENDING (3) Code Disposable Gas Bottles 00 None provided 10 Two bottles provided, 0.4% O 2 and 8% O 2, balance N 2 [145.3 gal. (550 liters), 10 lbs (4.5 kg) each] (4) Code Regulators for Bottles 00 None provided 10 2 regulators provided SPS 4000 B 20 1 1 10 10 10 Example Notes: (1) Reference air is recommended with 9 ft (2.74 m) and 12 ft (3.66 m) long probes. Reference air is also recommended when ambient air may not contain the normal 20.95% O 2, such as when the probe is mounted into a positive pressure duct with leaks or where there is a process unit nearby with leaks. (2) Customer to pipe from remote SPS to probe. (3) Hazardous area classifications require stainless steel fitting and tubing. (4) When used with calibration recommended feature, bottles should provide 2 to 3 years of calibration in normal service. Page 6

IMPS 4000/MPS 3000 MULTIPROBE AUTOCALIBRATION SEQUENCERS The IMPS 4000 and MPS 3000 Sequencers are multiprobe autocalibration sequencer systems capable of calibrating up to four in situ oxygen analyzers. It is provided in a NEMA 4X (IP56) enclosure which meets all standard (non-hazardous) industrial environments and applications with the following hardware: 1 common filter/regulator for reference air 1 reference flow rotometer per probe 1 test gas flow rotometer per probe solenoid valves and manifold termination board micro-programmable Logic Controller (PLC) (IMPS, only) The IMPS 4000 and MPS 3000 NEMA 4X enclosure can be Z or X-purged to meet Class I Div II Group B, C, and D hazardous area applications. It also utilizes a universal power supply which can accept any voltages from 85-264V, 50/60Hz. The IMPS 4000 is ideal for use with up to four Oxymitter 4000 Oxygen Transmitters. The IMPS 4000 utilizes the micro-plc to provide the necessary contacts for actuating the various solenoids within the autocalibration system. The Oxymitter 4000 utilizes its single contact output signal as a handshake interface with the IMPS 4000 which then fires the solenoids which introduce test gas to the Oxymitter 4000 probe for calibration. The PLC also offers additional alarm contacts to the user s control room: 1 cal initiate input contact per probe 1 in cal output contact per probe 1 common high gas on output contact 1 common low gas on output contact 1 cal failed output contact per probe (Includes 1 gas bottle pressure low pressure switch) SPECIFICATIONS Electrical classification: NEMA 4X (IP56) Humidity range: 95% Relative humidity Ambient temperature range: 32 o to 131 o F (0 o to 55 o C) with optional heater: -35 o to 131 o F (-31 o to 55 o C) Input power: 85 to 264V, 50/60Hz, 50VA External electrical noise: Minimum interference Handshake signal to/from Oxymitter (self-powered): 5V (5mA Max) IMPS only Cal. initiate contact input from control room (1 per probe): 24VDC (self-powered) Relay outputs to control room: 5 to 30VDC, Form A (SPST) (1 In-Cal per probe, Low Gas Flowing, High Gas Flowing, 1 Cal Failed per probe, Gas Pressure Low ) Cabling distance between IMPS 4000/MPS 3000 and electronics package: Maximum 1000 ft (303 m) Cabling distance between IMPS 4000/MPS 3000 and status relay indicator: Maximum 1000 ft (303 m) Piping distance between IMPS 4000/MPS 3000 and probe: Maximum 300 ft (91 m) Approximate shipping weight: 40 lbs (18 kg) IMPS 4000 ORDERING INFORMATION (used with Oxymitter 4000) Part Number Description Number of Probes 3D39695G01 Intelligent Multiprobe Sequencer (IMPS) 1 3D39695G02 Intelligent Multiprobe Sequencer (IMPS) 2 3D39695G03 Intelligent Multiprobe Sequencer (IMPS) 3 3D39695G04 Intelligent Multiprobe Sequencer (IMPS) 4 3D39695G05 IMPS with 115V Heater 1 3D39695G06 IMPS with 115V Heater 2 3D39695G07 IMPS with 115V Heater 3 3D39695G08 IMPS with 115V Heater 4 3D39695G09 IMPS with 220V Heater 1 3D39695G10 IMPS with 220V Heater 2 3D39695G11 IMPS with 220V Heater 3 3D39695G12 IMPS with 220V Heater 4 MPS 3000 ORDERING INFORMATION (used with World Class 3000) Part Number Description Number of Probes 3D39425G01 Multiprobe Sequencer (MPS) with 115V Heater 1 3D39425G02 Multiprobe Sequencer (MPS) with 115V Heater 2 3D39425G03 Multiprobe Sequencer (MPS) with 115V Heater 3 3D39425G04 Multiprobe Sequencer (MPS) with 115V Heater 4 3D39425G05 MPS with 230/240V Heater 1 3D39425G06 MPS with 230/240V Heater 2 3D39425G07 MPS with 230/240V Heater 3 3D39425G08 MPS with 230/240V Heater 4 3D39425G09 MPS with 100V Heater 1 3D39425G10 MPS with 100V Heater 2 3D39425G11 MPS with 100V Heater 3 3D39425G12 MPS with 100V Heater 4 3D39425G13 MPS with 220V Heater 1 3D39425G14 MPS with 220V Heater 2 3D39425G15 MPS with 220V Heater 3 3D39425G16 MPS with 220V Heater 4 Page 7