The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Similar documents
NAMIC Fluid Management

Xcela Hybrid PICC. Clinician Reference Tool

Disposable Transducers

DIAGNOSTIC CARDIOLOGY

Critical Disposables. Non-Sterile Angiographic Accessories. for Medical Device Manufacturers & Kit Packers

INTERVENTIONAL CARDIOLOGY

PRODUCT CATALOGUE OF

SPECIALTY DEVICES YOUR SOURCE FOR SPECIALTY DEVICES

Tridak Model 1050 User Guide

C O L O G Y. New. g u O N. l o t a C a. The high security connection

BIOCLOSURE SYSTEM ASSEMBLIES

Blood Pressure Monitoring: Arterial Line

Compatible Baxter IV Sets

New. The high security connection

PreludeSYNC. Radial Compression Device INSTRUCTIONS FOR USE

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

MyoSure Setup Simplified

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

MyControl Bathing System Signature Series

Varithena Delivery System Instructions for Use

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE

Instruction Manual Updated 7/26/2011 Ver. 2.2

RESPIRATORY HEALTH PRODUCTS

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING

BD Cytopeia Fluidic Kit User s Guide

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Research Grade Blood Pressure Transducer User's Manual

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Reference Guide. Correct Usage of EasySpray and Duplospray Pressure Regulator

ACCU-PULSE Installation and Operation Instructions

Patients Guide for Self Administering Intravenous Antibiotics General points

Rev. B. Operating Instructions

BPS-2, Rev TABLE OF CONTENTS

Making Life Easier Easypump II

RESPIRATORY HEALTH PRODUCTS

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

1020 Industrial Drive, Orlinda, TN fax

TJF-Q180V Cleaning and Disinfection Checklist

RD(H)20/25 Pressure-Reducing Regulator User Manual

Schroeder Check Test Point System

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Santa Fe Cycles Assembly Guide Introduction

MARK III Manometric Perfusion Pump Ve rtical Deck

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Training. Testor Training Manual

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

OPERATING INSTRUCTIONS

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

TJF-Q180V Cleaning and Disinfection Checklist

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

ARTERIAL MONITORING. Final Approval: VP Operations, Chief Nursing Officer Distribution: ICU, PACU POLICY:

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

ATS430 turbidity sensor Retractable insertion assembly

Bubble Tube Installations

Domiciliary Oxygen Switch. Instructions for Use

Rejuvenation Instructions

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

Manual Solvent Purification System. Innovative Technology, Inc.

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Parts identification:

6900 Maintenance Instruction System Flush

Models: C62/63/64-A/D

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

GI Series Diaphragm Pressure Gauge Guard

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

Safety Huber Needles

V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy.

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

Masoneilan* 78 Model Air Filter Regulator

TEST SPECIFICATION NYT-909-C

WE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel:

D05T Compact Design Pressure Regulating Valves

Constant Pressure Crude Oil Container Model CPCCP

Types 749B and R130 Changeover Manifolds

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

A complete family of Pediatric Perfusion Systems

Solvent System Walkthrough

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

Instruction for Use of Balloon Inflator JS-CE-SM-12-01, A/0

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Tourniquet Systems Pressure Infusion

Pitfalls & Practical Tips

Model 10. Low-Medium Pressure Reducing Regulator

Transcription:

Dream Kit

The NAMIC Dream Kit Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more than 40 years, NAMIC * Fluid Management products have been providing cardiologists, technicians and nurses with the Gold Standard in quality and reliability. As procedures, techniques and clinical requirements continue to evolve, AngioDynamics is committed to bringing you solutions to help meet your lab s changing needs. Introducing the NAMIC Dream Kit through our Fluid Management program, designed to: Help increase lab efficiencies Reduce number of hand tighten connection points Minimize contrast waste and maximize contrast budgets Dual back check valve eliminates the need to turn a stopcock when drawing contrast Compensator * Manifold Take pressure readings at any level 1 Integral transducer is 100% tested for accuracy Single operator set-up and re-zeroing Transducer closer to the pressure source How the Compensator Manifold Works: Compensator Port Unique Star Handle Design Large gripping surface Pressure Transducer OPEN POSITION CLOSED POSITION flexcil * Contrast Injection Line Allows for high pressure injections Provides flexibility Various lengths available to provide a single solution for both femoral and radial access 360 Star Handle Continuous Pressure Monitoring 2 Fewer manipulations 3

Squeeze * Contrast Controller Minimize contrast waste by utilizing larger bottles of contrast for multiple patients 4 Prevent cross contamination to the contrast source 4 Green Ball provides air embolization protection when fluids have depleted from the chamber Contrast Management Line available with and without chamber Dual Back Check Valve Decrease hand manipulations Allows for single-hand injection Designed to aspirate and inject contrast without manual manipulation of a stopcock handle 3 Acceler-8 * Syringe Slim barrel design designed to reduce the amount of force during injection and aspiration 5 Split collar retention designed to prevent plunger pull out Provides smoother aspiration and injection 5 1. Must have fluid filled pressure monitoring line attached to Compensator Port and after initial zero at heart level 2. Except during injections 3. Fewer manipulations than Standard Manifolds with non-360 handles. 4. Refer to contrast manufacturer s instructions for use 5. Data on file

Pre-bonded Manifold Assemblies Select a pre-bonded manifold assembly based on your labs needs. Type of Manifold Length Tubing Type Compensator Manifold Manifold Extension Line Manifold Syringe Extension Line Number of Ports Handle Style On/Off Contrast Port Saline Fluid Delivery Length Tubing Type 1 Off Dual Back Check Valve 45627268 15 cm (6 ) Extension 2 Star Off 49000050 2 Star Off Dual Back Check Valve 49000087 2 Star Off Dual Back Check Valve 49000183 2 Star Off Dual Back Check Valve w/ Vented Chambered Spike 76 cm (30 ) LPCIL 49000336 25 cm (10 ) flexcil 3 Star Off 25 cm (10 ) LPCIL 48807105 25 cm (10 ) flexcil 3 Star Off Dual Back Check Valve 48807128 25 cm (10 ) flexcil 3 Star Off 49000073 25 cm (10 ) flexcil 3 Star Off Dual Back Check Valve 76 cm (30 ) LPCIL 49000505 25 cm (10 ) flexcil 3 Star Off 25 cm (10 ) flexcil 49000147 25 cm (10 ) flexcil 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL 49000500 51 cm (20 ) flexcil 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL 49000086 51 cm (20 ) flexcil 3 Star Off 25 cm (10 ) flexcil 49000303 51 cm (20 ) flexcil 3 Star Off Dual Back Check Valve 51 cm (20 ) LPCIL 49000503 51 cm (20 ) flexcil 3 Star Off Dual Back Check Valve 49000506 76 cm (30 ) flexcil 3 Star Off Dual Back Check Valve 48807056 76 cm (30 ) flexcil 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL 49000510 3 Star Off Dual Back Check Valve 183 cm Vented Chamber (72 ) 48807017 3 Star Off Dual Back Check Valve 76 cm (30 ) LPCIL 48807074 3 Star Off Dual Back Check Valve w/ Chambered Spike 48807096 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL 48807139 3 Star Off Dual Back Check Valve w/ Vented Chambered Spike 51 cm (20 ) LPCIL 49000055 3 Star Off Dual Back Check Valve 49000187 NAMIC Manifold 25 cm (10 ) flexcil 4 Star Off Dual Back Check Valve 76 cm (30 ) flexcil 48807053 25 cm (10 ) HPCIL 3 Star Off Dual Back Check Valve 48807034 30 cm (12 ) Extension 3 Off Dual Back Check Valve 46627331 46 cm (18 ) Extension 3 Off Dual Back Check Valve 49000064 15 cm (6 ) Extension 3 Off Dual Back Check Valve 45627384 Perceptor Manifold 15 cm (6 ) Extension 3 Off Dual Back Check Valve 49000355 2 Off Dual Back Check Valve 49000171 Each pre-bonded kit is set up for right-handed configuration, with medium manifold pressure. Single sterile numbers and units are not available.

Components Adult Pressure Monitoring Lines Fittings Length Female Male 122 cm (48 ) 40701482 H965907014821 Box/25 Female Male 152 cm (60 ) 40701602 H965907016021 Box/25 Angiographic Control Syringes As shown: 70095007 As shown: 70095107 Barrel Size Plunger Style Barrel Style Fitting 0.5 ml Reservoir 7 ml Thumb Ring Finger Ring Fixed MLL Yes 40083003 H965700830031 Box/25 7 ml Thumb Ring Finger Ring Fixed MLL No 40083013 H965700830131 Box/25 7 ml Thumb Ring Finger Ring Rotating Adaptor Yes 40083007 H965700830071 Box/25 7 ml Thumb Ring Finger Ring Rotating Adaptor No 40083017 H965700830171 Box/25 8 ml Thumb Ring Finger Ring Fixed MLL Yes 40084003 H965700840031 Box/25 8 ml Thumb Ring Finger Ring Fixed MLL No 40084013 H965700840131 Box/25 8 ml Thumb Ring Finger Ring Rotating Adaptor Yes 40084007 H965700830071 Box/25 8 ml Thumb Ring Finger Ring Rotating Adaptor No 40084017 H965700830171 Box/25 10 ml Thumb Ring Finger Ring Fixed MLL Yes 40085003 H965700850031 Box/10 10 ml Thumb Ring Finger Ring Fixed MLL with 5 cm (2") Extension Yes 40085004 H965700850041 Box/10 10 ml Thumb Ring Finger Ring Rotating Adaptor Yes 40085007 H965700850071 Box/10 10 ml Thumb Ring Finger Grip Rotating Adaptor Yes 40085107 H965700851071 Box/10 10 ml Thumb Ring Finger Ring Extended RA Yes 40085005 H965700850051 Box/10 10 ml Palm Pad Finger Ring Fixed MLL Yes 40095003 H965700950031 Box/10 10 ml Palm Pad Finger Ring Rotating Adaptor Yes 40095007 H965700950071 Box/10 10 ml Palm Pad Finger Grip Rotating Adaptor Yes 40095107 H965700951071 Box/10 Contrast Management Systems As shown: H749904004351 Squeeze Chamber Chamber w/ Green Ball One-Way Check Valves Tubing Length Tubing Type Stopcock Fitting Yes Yes Yes 183 cm (72") IV No No No Yes 183 cm (72 ) IV Yes Male/Male Luer Lock Male/Male Luer Lock 40400435 H749904004351 Box/10 40400010 H965640000101 Box/10 Angiographic Guidewires OD inch OD mm Length Tip Description Core Coating 0.035 <0.94 145 cm 3 mm J Fixed PTFE 19700202 H965970002021 Box/10 0.035 <0.94 175 cm 3 mm J Fixed PTFE 19700210 H965970002101 Box/10 0.035 <0.94 260 cm 3 mm J Fixed PTFE 97000405 H965970004051 Box/10 0.038 <1.01 145 cm 3 mm J Fixed PTFE 19700205 H965970002051 Box/10 0.038 <1.01 175 cm 3 mm J Fixed PTFE 97000211 H965970002111 Box/10 Contrast Controller Spike Assembly Pressurized or Non-Pressurized Vented or Non-Vented Chamber or Spike Head Tubing Length Stopcock Fitting Convenience Kit Part Number Non-Pressurized Vented Spike Head 4 cm (1.5") 1-way Female 40400039 H965904000391 Box/25

Program By providing the NAMIC Dream Kit through our Convenience Kit program, you can tailor the accessories and components within the kit to meet your lab s needs and provide a full solution for your angiographic procedures. Contact your AngioDynamics NAMIC sales representative to make your dream kit a reality for your lab. Consult your AngioDynamics representative for country specific product availability. Distributed by Navilyst Medical Images may not represent actual products IMPORTANT RISK INFORMATION Refer to Directions for Use provided with products for indications, complete instructions, warnings, and precautions. NAMIC COMPENSATOR MANIFOLD INTENDED USE/INDICATIONS FOR USE: Physiological pressure transducers are utilized during invasive pressure monitoring, catheterization procedures and fluid delivery. WARNINGS: Do not exceed the following pressures when using this device - Main lumen: Medium Pressure Manifolds 1379 kpa (200 psi/14bar) Static pressure; High Pressure Manifolds 3447 kpa (500 psi/35 bar) Static pressure; Transducer Side Port 41 kpa (6 psi/300 mmhg). Do not use if package is opened or damaged. PRECAUTIONS: The Compensator line must be completely filled with saline to produce accurate pressure readings. The female luer end of the Compensator line (placed in a compatible mounting plate) must be at heart level in order to produce accurate readings. During fluid injection through the main lumen of the manifold, ensure proper orientation of the handles so that fluid does not enter the side ports. Do not use transducer Zero/Compensator Port as an injection site for fluids. NAMIC SQUEEZE CONTRAST CONTROLLER INTENDED USE/INDICATIONS FOR USE: The purpose of this system is to minimize contrast waste and allow one container of contrast media to be used on more than one patient. WARNINGS: Maintenance of sterility can only be achieved through proper set-up and use. Use proper aseptic technique when handling this device. Do not attempt to flush contrast media or air bubbles back through the contrast delivery system when the Squeeze Contrast Controller chamber is full of fluid. Flushing back through a full Squeeze chamber could damage the two check valves above the chamber and compromise the sterility of the spike assembly and contrast container. Do not use the spike assembly on more than one container of contrast media. Do not use the tubing assembly on more than one patient. Do not leave the spike assembly intact in a container of contrast for longer than six (6) hours. Do not replace the tubing assembly more than two (2) times. If there is any possibility that contamination may have occurred during set-up or use, disassemble and set up new sterile product. Ensure that you are making secure connections when using this device to prevent the introduction of air into the system that could result in embolism and in rare instances death. All connections should be finger tightened. Over tightening can cause cracks and leaks to occur that could result in embolism and or exposure to biohazards. Examine product carefully for entrapped air and fully debubble prior to injection to minimize the potential for embolism and in rare instances death. PRECAUTIONS: Carefully read these instructions completely prior to use. The chamber must hang vertically for the green ball to operate effectively. NAMIC ANGIOGRAPHIC CONTROL SYRINGE INTENDED USE/INDICATIONS FOR USE: The NAMIC Angiographic Control Syringe is intended to be used for the intraarterial or intravenous administration of radiographic contrast media. WARNINGS: Do not store fluid in product. Inject immediately after filling. This syringe does not have a pressure gauge device. Therefore, it is not intended for balloon catheter inflation. Over inflation may result in the rupturing of the balloon. NAMIC DEVICES: FLUID DELIVERY SETS, CONTRAST INJECTION LINES AND PRESSURE MONITORING LINES INTENDED USE/INDICATIONS FOR USE: These devices are intended to be used in fluid management and/or invasive pressure monitoring systems. NAMIC ANGIOGRAPHIC GUIDEWIRES INTENDED USE/INDICATIONS FOR USE: The Navilyst Medical Angiographic Guidewires are intended for use in percutaneous introduction of catheters. CAUTION: Federal Law (USA) restricts these devices to sale by or on the order of a physician. USA > 14 Plaza Drive, Latham, NY 12110 > tel: 800-772-6446 or 518-798-1215 > fax: 518-798-1360 International > Haaksbergweg 75 (Margriettoren), 1101 BR, Amsterdam Z-O > The Netherlands tel: +31 (0)20 753 2949 > fax: +31 (0)20 753 2939 Legal Manufacturer: Navilyst Medical, Inc. 26 Forest Street, Marlborough, MA 01752 www.angiodynamics.com AngioDynamics, the AngioDynamics logo, NAMIC, the NAMIC logo, Compensator, Squeeze, Acceler-8, flexcil and Navilyst Medical are trademarks and/or registered trademarks of AngioDynamics, Inc., and affiliate or subsidiary. May be covered by or for use under one or more of the following U.S. patents: 5,533,978; 5,779,666; 5,911,708 and foreign counterparts. 2013 AngioDynamics, Inc. NAVB 410 Rev. 1 11/13