MODEL LW74E, LW76E. Unit of Total Plate Front Cover Fitting HEX Soc. Bolt TAG (Ratings Shown) Register Front Cover

Similar documents
Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

Integral type Differential pressure flowmeter VNT Series

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

GAS FUEL VALVE FORM AGV5 OM 8-03

Model 130M Pneumatic Controller

Booster Regulator/Air Tank

TH-1800-T TRX-700-CNG Converter

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

TECHNICAL DATA. Q = C v P S

CCT-7320/ROC-2313 Reverse Osmosis Controller

TECHNICAL DATA. Q = C v P S

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

Time-Delay Electropneumatic Applications

SPECIFICATIONS ATTENTION

Torque Tube TB300 Digital Transmitters

SSL. Smart Valve Positioner.

Digital Flow Switch. Series PFM7

Operation Manual Air Saver Unit ASV5000 Series

TECHNICAL DATA. Q = C v P S

BUBBLER CONTROL SYSTEM

AHE58/59 AC Servo System

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

Flow and check valves Logic valves series 551. Brochure

For Multi-Parameter Meters see mvx

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Installation and Use Manual

For Multi-Parameter Meters see mvx

EXPERIMENT 2 LEVEL CONTROL SYSTEM

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Alimak Lift Control, ALC II User s Manual

ACV-10 Automatic Control Valve

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Built-in Purge Control Functions

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Air preparation units

INSTALLATION,OPERATION AND MAINTENANCE INSTRUCTIONS DRY AIR COOLER

NOTICE. Issued: February 12, 2010 AO# Dundas Street West, Oakville, ON CANADA Phone: (905) Fax: (905)

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

SSR. Smart Valve Positioner.

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

[Instruments for vacuum measurement, checking and adjustment] 3

SonoMeter 30 Energy Meters

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Introduction to Pneumatics

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

North American 7339 High Pressure Gas Regulators

Type 4708 Supply Pressure Regulator

Valve Proving System VDK 200 A S02

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Valve Proving System VDK 200 A S06*

Mod. M M M063..

Operating instructions Electrical switching facility pco

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

HERZ-Motorised flow controler

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Fisher DSA Steam-Atomized Desuperheater

Type 4660 High-Low Pressure Pilot

V43 Pressure Actuated Water Regulating Valve

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

KIT. Small Automatic Water Boosters KIT MODELS

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

Magnetic level switch type MR783 Instruction Manual

Autocalibration Systems For In Situ Oxygen Analyzers

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

LUGB Vortex Flowmeter

Pressure Independent Control Series

INSTRUCTION MANUAL Pressure Relief Device LPT

TECHNICAL DATA OBSOLETE

627 Series Pressure Reducing Regulators

Visualize Nitrogen Gas Consumption

Roller AC Servo System

Fisher DVI Desuperheater Venturi Inline

Quick Installation Guide Doc nr.: C Date:

Design DSA Steam-Atomized Desuperheater

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Vibration isolation system 1VIS10W. User manual

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Type 4708 Supply Pressure Regulator

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

TFC TM - Touch Force Control

How to specify a product. Process Sensors and Mechanical Instruments

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Electro-Pneumatic Converter YT-940 SERIES

Safe Accurate Reliable. CWM-301 Anesthesia System

Table 1: Safety Function (SF) Descriptions

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

Transcription:

Total-counter type Register ULTRA OVAL with BATCH CONTROLLER MODEL LW74E, LW76E GENERAL SPECIFICATION GS.No.GBC201E 5 GENERAL This unit is designed specifically to mount integrally on the ULTRA OVAL, a high-precision flowmeter, to provide a userfriendly batch processing system that is controllable in the field. Its battery-powered electronic register is programmable with front pushbuttons for batch processes (or quantities of the process material to be delivered). When used in combination with a pneumatic shutoff valve, you can build an automatic metering system which opens the shutoff valve upon depression of the start button and shuts it off when a preset quantity of the process material is reached. The register comes in two models: the LW74E with onestep open, one-step close arrangement and the LW76E with two-step open, two-step close (or one-step open, two-step close) arrangement. Applications include batch processes in chemical plants, blending, or filling, processes in the food, pharmaceutical, paint, petroleum, and chemical industries to save time and effort, streamline processes, and achieve product uniformity. FEATURES 1. An electronic arrangement offers reliability and long life. 2. Battery powered, it requires no external power source (battery life 4 years approx.). 3. Improved performance from previously offered mechanical models LW74 and LW76. Improved safety features, too. a. Figures in the LCD display are 12.7mm high. b. The selectable add or subtract mode total counter with a switch for a target batch setpoint. c. Can resume a metering cycle for the remainder of a batch that has been interrupted by an emergency stop. d. Batch setpoint (6-digit) and cumulative total count (8-digit) are selectable with a switch for management of totals. e.has safety features as i ) Missing pulse detection and alarm ii ) Overshoot (overmeasurement) detection and alarm iii) Low battery alarm 4. Waterproof construction (JIS C 0920 weathertight). Intrinsically safe explosionproof models conforming to the IEC standards also available. 5. Constructed of independent subassemblies to simplify maintenance. PART NAMES LCD Display (Total Count and Operation Status) Unit of Total Plate Front Cover Fitting HEX Soc. Bolt TAG (Ratings Shown) Meter Body (See note.) Flow Direction Arrow Connecting Flange Register Front Cover Stop Button (ROT.Button) Air Signal Connections OUT1 OUT2 Reset Button ( Button) Start Button ( Button) Register Body (Battery Pack Builtin) NOTE: Shown here combined with Size 57 meter body. http://www.oval.co.jp/english Head Office (Tokyo): Tel. +81 3-3360-5121 Fax. +81 3-3365-8605 International Sales Division Email: SK10@oval.co.jp Overseas Branch Offices: Beijing, Seoul, Singapore, Taipei

REGISTER SPECIFICATIONS Pneumatic Circuit Display Setup Item Type of Control Signal Air Pressure Air Signal Line Connection Distance to the Shutoff Valve Batch Setpoint Readout or Accumulated Total Readout (selectable with front pushbuttons) Operation Status Indicators Low Battery Alarm Type of Operation Operation and Programming Initial Setting (op) and Final Setting (cl) Missing Pulse Setup (PL) Overshoot Setup (ov) Scaler Coefficient (F) Setup Frequency Divide (d) Repeat Feature Emergency Stop Feature Backup Feature Power Supply Water-proof Construction Explosionproof Configuration LW74E Pneumatic one-step open, one-step close 0.20 to 0.69MPa (depends on the valve rating.) (Must be clean and dry air.) Description Rc 1/8 with a bite-type fitting for ø6 ø4 copper tubing provided 3 meters max. Batch setpoint: 6-digit, 7-segment LCD except for the 1st and 8th Cumulative total: 8-digit, 7-segment LCD (characters 12.7mm high) Total counter units of measure: Meter size 39 0.1mL, 1mL (standard), 10mL Size 41, 45 1mL, 10mL (standard), 0.1L Size 50, 52, 53 10mL, 0.1L (standard), 1L Size 55, 56, 57 0.1L, 1L (standard), 10L Shows in the 1st and 8th digit of the LCD only in the batch setpoint readout. RUN: Blinks while in operation OUT: Lights relative to valve operating signal output ALM: Lights to indicate missing pulses, or exceeding a preset overshoot, etc. COUNT: Lights while totalizer counts. END: Lights upon completion of a batch cycle. Front-panel LCD BATT lights when the battery life has approached. Select either add or subtract mode (subtract mode is standard). STOP, RESET, START manually with three front-panel pushbuttons. Batch setpoint (6 digits) Can be changed in the RUN mode. Cumulative total reading (8 digits) Can be changed in the SET mode. LW76E Pneumatic two-step open, two-step close (Set the initial setting to 0 to change to one-step open mode.) Set to any point from 0 to 999 counts in the Always set to 0 SET mode.(a setpoint at 0 establishes the one-step open, one close mode.) Set to any point from 0 to 15 sec. in the SET mode. (A setpoint at 0 disables the missing pulse setting.) Set to any point from 0 to 99 counts in the SET mode. (A setpoint at 0 disables the overshoot detection.) Set to any point from 0.0001 to 1.9999 in the SET mode. Selectable from one of 1/1, 1/10, and 1/100 in the SET mode. Provided Front-panel pushbuttons (STOP or RESET). Can resume measurement for the remaining cycle. Retains parameters, batch setpoint, total reading, cumulative total in an EEPROM. Dedicated battery (Good for 4 years approx. depending on operating conditions.) JIS C 0920 weather-proof (IP65) Select one of the following: 1 Non-explosionproof 2 Intrinsically safe explosionproof: Ex ia IIB T3 (1) TIIS explosionproof (Battery powered) (2) NEPSI explosionproof (Battery powered) Ambient Temperature Range 10 to +60 C (Valve actuating fluid must not contain drain or mist at low temperatures.) External Finish Munsell 2.5PB 5/8 (finished in baked melamine) Housing Material Aluminum die casting Physical Orientation Horizontal or vertical (view angle is adjustable) Option Air set (one set) includes a mist separator, Install a reducing valve with filter (mesh size 5μm approx.), etc. Mounts on ULTRA OVAL models up to size 31. Consult factory for application assistance. 2

Operation Time Chart and Pneumatic Circuit LW74E (Pneumatic one-step open, one-step close) (1) Combined with a double-acting torque cylinder ball valve (2) Combined with a diaphragm valve or springloaded torque cylinder valve Open signal ON (OUT1) Close signal ON (OUT2) Valve Position (Flow rate) Batch Setpoint Start signal A Time B Stop signal C End of batch Overshoot Open signal ON (OUT1) Valve Position (Flow rate) A Batch Setpoint Start signal Time : Use OUT 2 with a blind plug in place. B Stop signal C End of batch Overshoot LW76E (Pneumatic two-step open, two-step close) Initial Flow Control (Initial setting) OUT 2 (SV) (MV) ON ON Start signal Target batch setpoint One-step Open signal Full Open signal Final Flow control (Final Setting) Stop signal NOTE: Shown in this chart is the 2-step open, 2-step close arrangement. In the one-step open or one-step close mode, set both the initial and final setting to 0. Valve Position (Flow rate) Initial flow rate A B Time C Upper Limit Flow rate D Final Flow rate E End of A Batch Anticipated overshoot OPERATION Setup procedure for a batch: To establish a new batch setpoint, while the LCD (6-digit) shows a batch setpoint, reset the current setpoint and depress button for more than 3 seconds. The LCD (batch setpoint) then begins to blink, indicating that a new setpoint is acceptable. button adjusts the figure. button carries the figure to the next column. At a desired figure, press button. The batch setpoint is illuminated for approx. 2 sec. and goes to the RUN mode. (In the subtract counter, the display shows the new batch setpoint, and in the add counter, it shows "0,") Start metering: Press button to reset the batch setting. Making sure of the desired setpoint, press the button. When the initial setting is at "0." the shutoff valve in the pipeline opens fully and both the upper and lower indicator in the display light up. (The LW74E always behaves like this.) Except that the initial setting is at "0," only the lower indicator lights (the LW76E only). Metering: The process fluid begins to flow and the counter starts counting (the blinks on and off in sync with incoming counts). Initial controlled flow: (LW76E only) Except that the initial setting is at "0," a full open signal is generated when the fluid delivered has reached the initial setpoint and brings the shutoff valve to a full open. The upper lights. Final controlled flow: (LW76E only) Except that the final setting is at "0," a full-open signal is discontinued when the remaining quantity of a batch has reached the final setting, bringing the shutoff valve to a partial open position to reduce the velocity of flow. The upper goes out. End of batch: When the target batch is reached, the signal to the shutoff valve is discontinued, bringing the valve to a total closure to complete a metering process. All indicators go out and the comes on. Repeated metering: pressing button and then button allows repeated delivery of the same amount of process fluid. An attempt to start metering by pressing button without pressing button is prevented by an interlocked safety arrangement preventing inadvertent faulty operations sequence or tampering. Emergency stops: Metering can be interrupted by pressing or button at any moment while a batch process is in progress. By pressing START button, the operation will resume for the remaining process. Overshoot (overmeasurement): By determining the anticipated amount of overshoot (overmeasurement) due to inherent delay in valve actuation at valve closure and establishing a target setpoint with this anticipated overshoot taken into account, an accurate batch process can be achieved. An overshoot varies with such contributing factors as fluid velocity, piping conditions, and the type of shutoff valve. 3

SYSTEM CONFIGURATIONS Meter with LW74E Register (one-step open, one-step close) (1) Combined with a double-acting torque cylinder ball valve FPD1 To Pump (Contact-closure signal) (Open signal) EXH OUT 2 (Close signal) Combination Filter- Reducing Valve Air Press. 0.20 to 0.69MPa Flow Directrion ULTRA OVAL with Batch controller LW74E (V4) Double-acting Torqe Cylinder Ball Valve NOTE: Illustrated here for simplicity's sake. The flowmeter is actually installed with register display forward. (2) Combined with a diaphragm valve (combined with a spring-loaded torque cylinder ball valve) (Open signal) Blind Plug (OUT 2) FPD1 To Pump (Contact-closure signal) Air Press. 0.20 to 0.69MPa EXH Combination Filter- Reducing Valve Flow Directrion ULTRA OVAL with Batch controller LW74E (V3) Diaphragm Valve (or Spring-loaded Torque cylinder ball valve) NOTE: Illustrated here for simplicity's sake. The flowmeter is actually installed with register display forward. NOTES: 1. With a spring-loaded torque cylinder ball valve, the tubing runs same as that with a diaphragm valve. 2. In combining with a diaphragm valve or spring-loaded torque cylinder ball valve, stop up OUT 2 with a blind plug. 3. Specify LW74E (V3) when you order and we will ship with OUT 2 furnished with a blind plug. Meter Equipped with LW76E Register (MV) EXH Air press. to Valve Depends on Valve spec. Sig. Air press. 0.20 to 0.69MPa OUT 2(SV) Filter / Reducing Valve SV Air Direc- Tional Valve FPD1 MV To Pump (contactclosure signal) Flow Directrion ULTRA OVAL with batch controller (LW76E) Double Torque Cylinder Ball Valve NOTE: Illustrated here for simplicity's sake. The flowmeter is actually installed with register display forward. NOTE: When combined with OVAL pneumatic-electrical switch (Model FPD1), the pump can be interlocked. For complete details, see the pneumatic-electrical switch instruction manual. 4

FUNCTION OF THE DISPLAY UNIT Display Contents Lighting segment RUN Blinking on counting action a OUT Switching on a light upon output of batching valve (MV, SV) operating signal b, c ALM Alarm for emergency, i.e;pulse missing, overflow, battery power drop until reset of recovery d COUNT Switching on a light synchronizing with total counting. e END Switching on a light on finishing of a batch action continuing until reset operation is made. f BATT Blinking on battery power reduction g *See the marking fig in the fig. below. [LCD] Blinking on battery power reduction RUN OUT Batch counter (6 digits) Alarm lighting Totalizing count lighting ALM COUNT END Lighting on output signal of batch operation valve Cumulating counter (8 digits) Lighting on finishing of batch action For LW74E, on output of operating signal, segments (b, c) are lighting at a time. For LW76E (2-stage shutoff/open) : Single-stage open (small valve SV) Segment c lights in response to operating signal output Partially open Two-stage open (main valve MV) Segment c lights in response to operating signal output Fully open ABOUT SAFETY FEATURES The register is provided with the following safeguards: 1. Detection of missing pulses Either condition 1 or 2 causes the indicator ALM in the display to light and the shutoff valve to close automatically for safety. 1 The register fails to count any pulses within a preset missing pulse period (PL) from the moment a batch process started. 2 Counting pulses is interrupted during a batch process and remains interrupted beyond a preset missing pulse period (PL). The system starts detection of missing pulses 5 seconds from the start of a batch process; this 5 second delay is required for this function to go into effect. Large totalizer units of measure (weights of the total count) by frequency reduction or other processes may require more time to update the count, but such conditions will not trigger a missing pulse detection alarm. If 0 is chosen for a missing pulse setpoint (PL), the capability to detect missing pulses will remain disabled. For manual batch processing, therefore, we recommend using a setpoint at 0 2. Detection of an overshoot (overmeasurement) An overshoot of measurement at the end of a batch does occur due to some time lag in shutoff valve actuation (closure). An indicator ALM in the display lights when the register counts more than the anticipated overshoot count (ov). When 0 is chosen for the anticipated overshoot count (ov), the overshoot detection feature remains disabled. 3. Detection of a low battery When the built-in battery becomes weak, a blinking BATT alarm will appear in the display. As battery power nears zero, a steady ALM comes on, the shutoff valve closes automatically (if in an open position) and, at the same time, the variables (total count in a batch process and cumulative total count) are saved to memory. From this moment onward, valve operation will remain inoperative (the start button will not respond). Generally, it takes about 8 days from a blinking BATT alarm till a steady ALM. It is suggested that the old battery be replaced with a new one during this period. 5

OUTLE DIMENSIONS (Unit in mm) 192.5 External earth terminal 131.2 To main body of ULTRA OVAL, ULTRA UF-II (97.6) 20 20 Air signal connection 10.5 38.5 Exhaust PLEASE SUPPLY THE FOLLOWG FORMATION WHEN YOU QUIRE. Item Description 1. Companion flowmeter model 2. Fluid name 3. Flow range Min. Nor. Max. m 3 /h, L/h 4. Companion register model LW74E LW76E 5. Units of total counter L 6. Initial setting (op) L (with LW76E) 7. Final setting (cl) L (with LW76E) 8. Missing pulse setting (PL) sec 9. Overshoot setting (ov) L 10. Signal air pressure MPa 11. Distance from flowmeter to Shutoff valve 12. Shutoff valve type m (Max. 3m) Spring-loaded torque cylinder ball valve Double-actuating single torque cylinder ball valve Diaphragm valve Double-actuating two torque cylinders ball valve Spring-loaded double torque cylinder ball valve Fits LW74E (V3) Fits LW74E (V4) Fits LW74E (V3) Fits LW76E Fits LW76E 13. Air set (mist separator,combination filter/reducing valve) Req d Not req d The specification as of July, 2016 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: GS.No.GBC201E 初版改訂印刷 99.02 16.07