LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

Similar documents
2 Sentry MCL Installation, Operation & Maintenance

1200 Series Pressure Regulators

Description Advanced Features Typical Applications

2 Sentry MVS Installation, Operation & Maintenance

SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS.

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Tank Blanketing Pressure Regulators RHPS Series

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

Inert Air (N2) Systems Manual

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

view Matters Magnetic Level Indicators 1100 Series with indicator The 200º viewing angle 200º viewing angle

Alkylphosphines. Storage and Handling Recommendations

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

Grab Sampling Systems

Installation, Operation & Maintenance Manual

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

RCS Rupture Disc Assembly

NOTES. ITT CONOFLOW - QUICK REFERENCE GUIDE Airpak, Filter-Regulator / Filter Only

Neotecha Tank Sampling Sapro

Chlorinator. MODEL C-731 (Floor Mounted)

GILMONT ACCUCAL FLOWMETERS

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Sample Cylinders and Accessories

Neotecha Tank Sampling Sapro

Installation, Operation, and Maintenance Manual

Installation, Operation & Maintenance Manual

Best Practices for Installation of Gaseous Sample Pumps

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

REFRIGERATION SYSTEM COMPONENTS

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Instruction Manual Updated 7/26/2011 Ver. 2.2

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

HP/UHP Spring-Loaded Regulator

Avenger Model 33M Installation & Operation Instructions

Pneumatic Powered - Plunger Pumps

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Requirements for the Ethylene MACT

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

PRO-50 Instrument Supply Regulator

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

SCA Series Inverted Bucket Steam Traps

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER COMPOSITE GAS SAMPLER

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

MEDICAL EQUIPMENT CATALOG

FOAM TANK (1/2) DATA SHEET

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

JR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Suggested Installation & Operating Instructions for Sidewinder Pumps

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

Torque Tube TB300 Digital Transmitters

Model DE-1, VDE-1 and DE-2 Air Release Heads

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

L21S/SR/ST Glass Level Gauges

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

The "BETA AIR RELAY"

REGULATORS FOR SPECIFIC APPLICATIONS

4-W GAS ODORIZER WITH POSITIVE ACTION INDICATOR GAUGE (300 PSIG) 2014 INFORMATION MANUAL SUBMITTED BY:

Installation, Operation & Maintenance Manual

Manual Solvent Purification System. Innovative Technology, Inc.

Albany Connecticut Vermont Westchester

Guardian Membrane Separators

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

Installation, Operation, and Maintenance Manual

NORMAL OPERATING PROCEDURES Operating Parameter Information

Bubble Tube Installations

GM Series Dual-Block Multi-Function Gas Control Valves

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

Proportional Relief Valves

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Installation, Operation & Maintenance Manual

Specialty Gas Equipment Catalogue

Type 92S Pilot-Operated Steam Regulator

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

ProMinent Gas Chlorination

RGC-IR Remote Gas Calibrator for IR400

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

ASK HEROSE HEROSE NEWS NEW! EXCLUSIVE STOCK GENERANT SDC SERIES FOR DOT-4LC AND TC-4LM LIQUID CYLINDERS SILENT OPENING LCV & POP ACTION CRV CALL NOW!

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

FOAM TANK (1/2) DATA SHEET

LRS(H)4 Pressure-Reducing Regulator User Manual

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Pressure reducing valves Index

MEDICAL CYLINDER VALVES

829S1 Series Flexflo Pilot

VOC Process Equipment Clearing, Cleaning, and Routine Maintenance. Individual Unit Function: Environmental Procedure No.: PA Page: 1 of 10

RD(H)20/25 Pressure-Reducing Regulator User Manual

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

R-410A 50% R-32 50% R-125.

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

Transcription:

N LGSS Liquefied Gas & VSS Vapor (Gas) Sampling Systems The SENSOR Cylinder Sampling Systems allow collection of samples from gas and light liquid hydrocarbon applications in a manner that is safe to both the operator and the environment. The sampling process is emissions-free, with no spills and zero Volatile Organic Compounds (VOC) emissions, while keeping sample contamination levels to a minimum. The Liquefied Gas Sampling System (LGSS) allows an operator to visually verify cylinder outage and maximum fill density through our innovative sight glass system, ensuring compliance with regulatory requirement U.S. CFR49. LGSS The Vapor Sampling System (VSS) has many of the same benefits of the LGSS, but allows for the safe and representative sampling of nonliquid gaseous samples. On the VSS, the sight glass is eliminated and the flow is reversed to ensure no condensate is left in the cylinder while sampling. VSS Features and Benefits Cylinder saddles to correctly position and secure sample cylinder Robust double-ended shutoff quickconnect fittings (QC s) Ability to depressurize QC s before removing cylinder from sample panel Single handle operation Flush entire system before taking new sample Panel mounted pressure gauge Operation & Installation Manual included SENSOReng.com I Sampling Systems 281-902-3924 LGSS Sampling Systems LGSS and VSS 1/8

Product Specifications Standard Equipment Mounting Plate Stainless Steel (SS) Sight Flow Indicator 600# ANSI with flow indicator Quick Connect Fittings Stainless Steel, double-ended shutoff Cylinder Saddles 2 each, PVC Tubing 1/4 Stainless Steel Optional Sample Cylinder Stainless Steel; includes cylinder valves Operation/Instruction Included as standard on plate Tags Operating Pressure 1440 psig; 2000 psig max @ 70 F Operating Temperature 350 F maximum Materials of Construction Sample Loop 316SS Sample Valve 316LSS O-Ring Material Viton standard; optional Kalrez Seal Material Teflon Optional Equipment System Purge Includes check valve, regulator, rotameter, pressure gauge, and block valve Emissions Filter Canister with activated carbon for use when no vent to flare is available; also available with indication crystals which change color to indicate saturated absorbent media Isolation Valves Isolation valves on sample inlet & outlet to allow for easy serviceability Sample Coolers For use when process temperature exceeds 135 F Enclosures Enclosures, available insulated and uninsulated and with steam or electric heater elements Mounting 2 X 60 pipe stand; galvanized Armored Rotameter Sized for flow rate provided on Application Data Sheet Sample Cylinder Stainless Steel; includes cylinder valves and quick connect fittings Sample Cylinder Dip tubes; rupture discs, coatings Accessories High Pressure System Includes reflex sight glass and extended operator handle LGSS and VSS Sampling Systems SENSOReng.com I Sampling Systems 281-902-3924 2/8

How to Order Below is the quick select model number tree that provides you with all the options to configure and order a sampling system for your application. You must select a designator for each component You must supply a completed application data sheet Process Connection 1/4 Tubing (standard) 3/8 Tubing 3/4 Tubing Flanged (specify size and rating) Cylinder Size Cylinders supplied with system as option 300cc (standard) 150cc 1000cc Special (please specify) Model 1 Liquefied Gas Sampling System LGSS Vapor (Gas) Sampling System VSS 2 30 15 1K XX 3 25 37 75 FF 4 Optional Equipment AR Armored Rotameter CC Emission Filter (Activated Carbon w/ Indication Crystals) CF Emission Filter (Activated Carbon) CY Sample Cylinder (Size to match Cylinder Size in Model Number) DT Cylinder Dip Tube (available on LGSS only) EE Enclosure w/ Electric Heater EI Enclosure (Insulated) EN Enclosure (Non-Insulated) ES Enclosure w/ Steam Heater HP High Pressure System (>1400 psig) IB Isolation valves In/out (Ball Valves) KZ Kalrez O-Rings PC Process Cooler PS 2 X 60 Pipe Stand w/ Base RD Rupture Discs SL Silconert Internal Coating SP System Purge XX Other Options (please specify) LGSS - 30 75 IB Example Model No. SENSOReng.com I Sampling Systems 281-902-3924 Sampling Systems LGSS and VSS 3/8

Cylinder System Application Data Sheet Date Name Company/Location PROCESS DATA Phone Email Media m Gas m Liquid Vapor Pressure (at sampling temp) Tag Numbers *Pressure Inlet *Fast Loop Outlet Pressure m With Process Return m Without Process Return *Viscosity (CP) at Sampling Temperature *Temperature Temperatures over 135 F, Process Cooling is recommended Particles in Sample m Yes m No Micron Size / (%) if >100 micron y-strainer recommended MATERIALS OF CONSTRUCTION *Wetted Parts m 316SS (std.) m Monel 400 m Hastelloy C276 m Other *specify *O-Ring Material (Elastomer) m Viton (std.) m Kalrez (recommended in H2S service) m Other *specify *Valve Packing Material m Teflon (std.) m Graphoil (Hi. Temp) CONNECTION AND MOUNTING *Sample Inlet/Outlet Connection Size (1/4 Tube Standard) *Sample Inlet/Outlet Connection Type (specify Tube, NPT, Flange) *Flare Vent Pressure Type m Flare m Carbon Canister m Other *specify SAMPLE CONTAINER *Size Sample Container m 300cc m 500cc m Other *specify *Cylinder Quick Connect Part Number Brand/PN# *Cylinder Accessories m Dip Tube m Rupture Disc m Spring Relief *Cylinder m Supplied m Customer supplied OPTIONS (please check if needed) m Sample Cooler Additional Data Needed, Please complete heat transfer document m PipeStand for Mounting System m Process Purge m Enclosure Type Insulated m Yes m No Heated m Yes m No if yes, m Steam or m Electric if electric, Volts m Process Block Valve m Sample Inlet m Sample Outlet m Both m Check Valve on Vent Special Configurations available (please contact your local representative for information). Detector Tube System, Lab Docking Station, Special Coatings (Siliconert) Please use page two for any comments/include sketch if available. *Required information 281-902-3924 SENSOReng.com LGSS and VSS Sampling Systems SENSOReng.com I Sampling Systems 281-902-3924 4/8

Cylinder System Application Data Sheet SKETCH Vessel or APPlicATion HERE SENSOReng.com I Sampling Systems 281-902-3924 Sampling Systems LGSS and VSS 5/8

Cylinder System Application Data Sheet VSS Vapor Gas Sampling System LGSS Liquefied Gas Sampling System LGSS and VSS Sampling Systems SENSOReng.com I Sampling Systems 281-902-3924 6/8

See our full line of Sampling Systems at SENSOReng.com SENSOR sampling systems provide a representative sample that is safe to both the operator and the environment. Our systems are designed to meet Leak Detection Repair (LDAR), Maximum Achievable Control Standards (MACT) and Volatile Organic Compounds (VOC) emission standards. Since no two sampling systems are exactly alike, each of our products is engineered to order. Basic Bottle Sampling System Simple, flow-thru valve design Zero dead volume Replaceable process and vent needles Available with SENSOR Needle Purge BBSS ISS Fixed Volume Bottle Sampling System Guarantees repeatable sample volume Zero dead volume Replaceable process and vent needles Suitable for high process pressures SENSOR needle purge standard FVBSS Inline Sampling System Liquefied & Vapor Gas Sampling Systems Safe, simple methodology for sampling high pressure liquefied gasses and process gasses Single handle operation Panel mounted pressure gauge Sight glass ensures safe cylinder outage on LGSS Ability to depressurize quick connects before removing cylinder Available in wide variety of piping materials and end connections Suitable for high temperature, high viscosity service Available with open tube stinger or process needle LGSS & VSS SENSOReng.com I Sampling Systems 281-902-3924 Sampling Systems LGSS and VSS 7/8

N SENSOReng.com Sampling Systems Houston, TX 281-902-3924 REGIONAL OFFICES China SOR China Beijing, China china@sorinc.com +86 (10) 5820 8767 Fax +86 (10) 58 20 8770 Middle East SOR Measurement & Control Equipment Trading DMCC Dubai, UAE middleeast@sorinc.com +971 4 363 3637 Fax + 1 913 312 3596 LGSS and VSS Sampling Systems SENSOReng.com I Sampling Systems 281-902-3924 8/8 SENSOR is owned and operated by SOR Controls Group