Catalog. Series. Pressure Insensitive (PI) Mass Flow Controller. Series. Digital Mass Flow Controller (non-pi), Mass Flow Meter

Similar documents
PS100 Series. Pressure-Based PI Mass Flow Controller. Catalog

Aera PI-980 Series Pressure- Insensitive MFCs

Catalog. Aera. FC-PIR98x. Series Pressure- Insensitive MFCs. Next-generation PI technology for tomorrow s manufacturing demands

Pamphlet. 1480G 2480G series. Hitachi Metals, Ltd.

TKF Mass Flow Controller. FCS Thermal Series. Digital interface 준비장비 (RS-485)

SFC1480FX SFC2480FX series

Model 601CV. Mass Flow Controller. Product Features:

High Performance Mass Flow Controller

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Design Features. General Description

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Digital Mass Flow Meters and Controllers for Gases

Aera Industrial MFC Product Guide. Innovative Control at Work

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

Porter Analytical & Industrial Products

Mass Flow Controller (MFC) for Gases

Bypass Mass Flow Controller (MFC) for gases

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Mass Flow Controllers

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

GAS Piezo Actuator Type Mass Flow Controllers

CAT:No E-H FCS. Flow Control System. Thermal Series. We welcome customer feedback for all of our products and services.

GasSense NDIR User Manual

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Mass Flow Controller (MFC) for Gases

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Miniature Electronic Pressure Controllers. Precision Fluidics

Mass Flow Meter (MFM) for gases

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

HumiSys HF High Flow RH Generator

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Quick Installation Guide Doc nr.: C Date:

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

UNDERSTANDING, ACCELERATED

TH-1800-T TRX-700-CNG Converter

Flow Meters and Flow Controllers

Brooks GF100 Series High Purity/Ultra-High Purity Digital Thermal Mass Flow Devices

GF135 Digital Mass Flow Controller

Hitachi Differential Pressure/Pressure Transmitter

GAS Solenoid Actuator Type Mass Flow Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Mass Flow Meter (MFM) for Gases

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Smooth Vent Valve. XVD Series

780S Ultra High Purity Series

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

ASDX Series Silicon Pressure Sensors

Brooks Models SLA SLA7860 Mass Flow Controllers & Meters

Smooth Vent Valve XVD. Series

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

AMS 6916 Board mount pressure sensor with ratiometric analog output

AMS 2710 PCB pressure sensor module with V output

SUPER PRECISION AIR RELAYS

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

Products Guidance. Combined catalog GAS LIQUID VACUUM ANALYSIS. Vacuum Measurement. Technology. Flow Control Technology. Liquid Source Vaporization

75 Allen Street Lexington, MA Minute Model & Pricing Overview Guide

Digital electro-pneumatic regulators Series ER100

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

86BSD Backside Digital Output

2/ Port G1/4

Datasheet: K-30 ASCII Sensor

INSTALLATION & MAINTENANCE INSTRUCTIONS

Mass Flowmeters. Mass Flowmeters for Gases

P499 Heavy Duty Pressure Transducer

The Ins and Outs of I/P Transducers

SLA5810/20/40 SLAMf10/20 Series

Digital Flow Switch. Series PFM7

Precision pressure sensor Basic version Model CPT6020

P900. P900, Datenblatt Seite 1 DESCRIPTION

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Porter Lab & Analytical Products

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

COSMO INSTRUMENTS CO., LTD.

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Gas Mass Flow Meter SUS/SUS316

Datasheet SFC5400 / SFM5400 mass flow controller / meter for gases Product Information October 2016 V12

Installation and Operation Manual

Electronic Volume Correctors

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

PURA. Pure Gas Dewpoint Transmitter. Users Guide

DPS-400 SERIES DPH-100 SERIES

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases

SmartTrak. High Performance Digital Gas Mass Flow Meters & Controllers. DESCRIPTION

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

CANADA SENSORS TECHNOLOGY INC.

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Transcription:

Catalog Series Pressure Insensitive (PI) Mass Flow Controller Digital Mass Flow Controller (non-pi), Mass Flow Meter Series

Features Quick flow-response, 0.3s (HG0 series) 10 millions life cycle, robust diaphragm valve DeviceNet TM, RS-485/analog, EtherCAT are applicable Self-diagnostic / response learning function (HG0 series) Mass flow controller is one of the most critical devices in the semiconductor manufacturing tools, it is progressing with changes in the cutting-edge process. HG0/HC100/HM100 series is a digital MFC/MFM model with the proven thermal sensor. HG0/HC100/HM100 series have the improved essential performance like the response, robustness for ALD process, valve shut-off capability, control range, flow accuracy with the times. High speed flow-response 0.3s (HG0 series) The quick rise and fall characteristic of the flow is important in case of the quick turn-around recipe in the process tool. HG0 series satisfy excellent response time, 0.3s (from Multi-1 to Multi-5) by applying the improved algorithm. 1 100 0.3s 1 0.3s 100 Flow Out[%] 80 60 40 Flow Out[%] 80 60 40 0 1 1.1 1.2 1.3 1.4 1.5 1.6 Time[s] 0 1 1.1 1.2 1.3 1.4 1.5 1.6 Time[s] The example of the rising edge in the wave form (Multi-4) The example of the falling edge in the wave form (Multi-4) 10 millions life cycle, robust diaphragm valve The open and close cycle results a big number in the process, such as ALD to repeat the open and close frequently. HG0 / HC100 series applies 10 millions life cycle design with the optimized drive circuit and PIEZO element in the valve, Co-Ni alloy diaphragm. DeviceNet TM, RS-485 / analog, EtherCAT are applicable This product applies analog interface, digital interface as DeviceNet TM and the high speed communication as EtherCAT. Self-diagnostic / response learning function In case of the flow rising turn from zero, there may be a problem to have the various valve start position and the rising slope for each MFCs. The response learning function in this MFC enables the uniform and stable rising characteristics. The MFC self-diagnosis for the abnormal operation, display of the alarm and notification in the communication are in this unit. 2

Other Features Multi-gas, Multi-range selection 9 BIN size MFCs enable to control from 10SCCM to 50SLM High accuracy, ±1%S.P. @10-100% (N 2 ) Wide flow control range, 0.5-100% F.S. (NC type with PCTFE poppet model) High valve shut-off performance, 0.1% F.S. (NC type with PCTFE poppet model) Wide temperature range 15-50 RoHS / CE compliant Pressure Insensitive function (HG0 series) 9 BIN size MFCs enable to control from 10SCCM to 50SLM 9 BIN size MFCs enable to control flow-rate from 10SCCM to 50SLM in case of the Multi gas, Multi range model. The MFC with each BIN is applicable for wide flow range so that the possibility to convert the flow rate and/or gas name is high without replacing the MFC with other BIN, it means that these models are excellent in flexibility on-site. High accuracy, ±1%S.P. @10-100% (N 2 ) The flow range to guarantee the flow accuracy as ±1% S.P. is expanded to 10 100% F.S. from the spec in the legacy model, 25 100% F.S. Wide flow control range, 0.5-100% F.S. Leak across the valve 0.1% F.S. The amount of gas between the down-stream side of the MFC valve and the pneumatic valve after the flow rate setting value is set to zero may have a problem. The MFC with 0.1% F.S. as a valve shut-off performance in HG0 / HC100 series (NC type / PCTFE poppet model) reduce its impact. Wide temperature range 15 50 The small gas box in the process tool may results the high ambient temperature around the MFC against the supposition. This product equipped high quality devices and low power design so that the ambient temperature range is applicable up to 50. RoHS / CE compliant This product is EU-RoHS and CE marking compliant. Pressure Insensitive function (HG0 series) Pressure Insensitive function enables stable flow control in case of the pressure fluctuation at upstream or downstream of the MFC. The flow range is expanded to 0.5 100% F.S. (NC type with PCTFE poppet model) from the spec in the legacy model, 2 100% F.S. The wide flow range has more possibility to control by a single MFC in the gas system instead of 2 MFCs. Electrical Connection Analog model 9Pin D-sub male type (M3 screw) VALVE OPEN / CLOSE 1 Connect to +15V : OPEN Connect to -15V : CLOSE 2 OUTPUT (0-5VDC / 0-100%F.S.) 3 INPUT POWER (+15VDC) 4 POWER COMMON 5 INPUT POWER (-15VDC) SET POINT INPUT 6 (0-5VDC / 0-100%F.S.) 7 SIGNAL COMMON 8 SIGNAL COMMON VALVE voltage output (0 4V / 0-100%) 9 RS485 model 9Pin D-sub male type (M3 screw) 1 NA 2 NA 3 INPUT POWER (+15VDC) 4 POWER COMMON 5 INPUT POWER (-15VDC) 6 NA 7 SIGNAL COMMON 8 RS485+ 9 RS485- DeviceNet TM model CM02-8DR5P-CF (D5) DDK 1 SHIELD 2 INPUT POWER (+11-25VDC) 3 GND (-) 4 CAN (H) 5 CAN (L) EtherCAT model (Power connector) XS3M-M524-1 OMRON 1 +24VDC 2 FG 3 POWER COMMON (0V) EtherCAT model (Communication connector) Cat.5 RJ45 Ethernet connector Category 5 networking Ethernet cable is used. 3

Series Series Specification Full-Scale Range (N 2 equivalent flow) Flow Sensing Flow Calibration Settling Time (SEMI TM E17-91) 2 Items HG0 / HC100 / HM100 HG1 / HC101 / HM101 10-5,000SCCM (Multi-1-6) Thermal Sensor Type Multi Gas, Multi Range (9 BINs) HG0 / HG1: < 0.3s (Multi-1-5), < 0.5s (Multi-6, 7) HC100 / HC101: < 0.5s (Multi-1-7) 5,001-10,000SCCM (Multi-7) 10,001-50,000SCCM (Multi-8, 9) < 0.7s (Multi-8, 9) Accuracy (N 2 ) 3 < ±1%S.P. (10-100%), < ±0.1%F.S. (2-10%) Linearity < ±0.5%F.S. Repeatability < ±0.2%F.S. Zero Stability < ±0.3%F.S. / year Leak Integrity < 1x10-11 Pa. m 3 /s (He) Flow control range 4 0.5-100%F.S. (PCTFE poppet model), 2-100%F.S. (Metal poppet, NO model) Operating Pressure Range 5 50-400kPaD (Multi-1-6) 70-400kPaD (Multi-7) 250-400kPaD (Multi-8, 9) Operating Pressure Range (HM100 / HM101) kpad Maximum Operating Upstream Pressure 400kPaG Operating Downstream Pressure Range Vacuum to atmospheric pressure [Contact sales if the downstream pressure more than atmospheric pressure is required] Leak Across Valve Proof pressure Ambient Temp. Range Internal pressure sensor accuracy (HG0 / HG1) Internal temp. sensor accuracy (HG0 / HG1) Control Valve Type Materials for external seals Materials for gas wetted Fittings Surface Finish Orientation Mass < 0.1% F.S. (PCTFE poppet), < 1.0% F.S. (Metal poppet, NO model) [N 2 P1=50kPaG (Multi-1-6), 70kPaG (Multi-7), 250kPaG (Multi-8, 9), P2=atmospheric pressure] HG0 / HG1: 0.6MPaG, HC100 / HC101/ HM100 / HM101: 1MPaG 15-50 [Gas temperature needs to be equal to ambient temperature] < ±5kPa [0-500kPa (abs)] < ±1 [15-50 ] Normally-Closed (NC) and Normally-Open (NO) Piezo Valve 316L S.S. 316L S.S., PCTFE, Co-Ni alloy mm 1.125 Cseal, mm 1.125 Wseal, 124mm 1/4 VCR type Electro-polished (fitting, sensor, base) Ra=0.2μm, machine finish Ra=0.8μm Any position 1.1kg Special function Pressure Insensitive function (HG0 / HG1 series) microsd TM card, LCD Display to monitor the various parameter (HG0 / HG1 series) Signal interface Analog, Digital (RS485, DeviceNet TM, EtherCAT ) Analog : 9Pin D-sub Connector type Digital : RS485, DeviceNet TM, EtherCAT Maintenance : RS485/Φ2.5 3-pole round connector (for all model) Input power 1 DeviceNet TM : +11VDC 500mA - +25VDC 230mA Analog : +15VDC ±4% 90mA, -15VDC ±4% 60mA EtherCAT : +24VDC ±10% 1mA Flow set signal (Analog model, except HM100 / HM101) 0-5VDC / 0-100% F.S. input impedance > 1MΩ Flow out signal (Analog model) 0-5VDC / 0-100% F.S. load impedance > 2kΩ 1. This specification is defined based on our standard test condition with single MFC. The performance with the different condition may not satisfy this specification, and we do not guarantee this specification under the condition with all combination of the configuration. 2. From 0% to 5%S.P. or greater, ambient temperature is 22 ±10 3. Digital mode, ambient temperature is 22 ±3 4. Valve closes if the set point applies less than 0.5%F.S. 5. For N 2 full-scale flow in case of outlet pressure less than half of the inlet pressure minus 13.8kPaA. SCCM, SLM are the unit to indicates the gas flow-rate as ml/min, L/min at 0, 101.3kPa(abs) condition. F.S.=full scale S.P.=set point 4

Dimensions 1.125 IGS fitting 114 16.6 Inlet side connector type 9Pin D-sub model EtherCAT model 9Pin D-sub model Inlet side connector type 113 108 124mm 1/4 VCR type fitting 4-M4.4 12.7 114 7 69 18 124 124 7 18 41.9 69 41.9 5 4-M4.4 69 124 7 12.7 12.7 18 Inlet side connector type 16.6 9Pin D-sub model 41.9 4-M4.4

HG0 / 1, HC100 / 101, HM100 / 101 series model and suffix codes Category Description Suffix codes HG0 PI-MFC HG1 Model Thermal HC100 sensor Non-PI-MFC type HC101 HM100 Non-PI-MFM HM101 Analog (9Pin D-sub) A Interface DeviceNet TM D L Protocol RS485 (9Pin D-sub) L EtherCAT E Top (except L Protocol RS485 model) T Connector location Inlet side (except analog and EtherCAT model) U External seals Metal seal M Valve type Normally closed C Normally opened O mm 1.125 Wseal BW1 Fitting mm 1.125 Cseal BA1 124mm 1/4 VCR type 4V2 Fixed code 1 Optional code NNN 10 to 30 SCCM Multi -1 31 to 100 SCCM Multi -2 101 to 300 SCCM Multi -3 301 to 1,000 SCCM Multi -4 Full scale range 1,001 to 3,000 SCCM Multi -5 3,001 to 5,000 SCCM Multi -6 5,001 to 10,000 SCCM Multi -7 10,001 to 30,000 SCCM Multi -8 30,001 to 50,000 SCCM Multi -9 HG0DTMCBA11NNN Multi-5 Example Thermal type PI-MFC, DeviceNet TM, Top connector, Metal seals, Normally closed Piezo valve, 1.125 mm Cseal fitting, No option, full-scale 3000SCCM http://www.hitachi-metals.co.jp/e/ Headquarters High-Grade Functional Components Company Piping Components Business Unit Sales Dept. of Fine Flow Shinagawa Season Terrace, 2-70, Konan 1-chome, Minato-ku, Tokyo 108-8224, Japan Tel +81-3-6774-3530 Fax +81-3-6774-4348 Customer Support 210 Obuke, Asahi-cho, Mie-gun, Mie-Pref. 510-8102, Japan Tel +81-59-377-3511 Fax +81-59-377-4575 Hitachi Metals America, Ltd. San Jose Office 19 Zanker Road, San Jose, California 95112, U.S.A. Tel +1-408-467-8900 Fax +1-408-467-8901 E-mail : aerasales-usa@hitmet.com Hitachi Metals Europe GmbH Immermannstrasse 14-16, 40210 Duesseldorf, Germany Tel +49-211-16009-0 Fax +49-211-16009-29 E-mail : aerasales-europe@hitachi-metals-europe.com Safety Precaution Before using any of the products introduced in this catalog, please read the respective user manuals thoroughly. Contents of this catalog are as of October 16. The products and their specifications are subject to change without notice. Please check the latest catalog, technical documents or specifications before your final design, procurement or use of the products. Aera is a trademark of Hitachi Metals Ltd. DeviceNet TM is a trademark of Open Device Net Vendor Association, Inc. (ODVA). VCR is a registered trademark of Swagelok Company Corporation. IGS and Wseal are registered trademarks of Fujikin Incorporated. SEMI TM is a trademark or registered trademark of Semiconductor Equipment and Materials International in the United States. microsd TM is a trademark or registered trademark of SD Card Association. EtherCAT is a registered trademark and patented technology, licensed by Beckoff Automation GmbH, Germany. Hitachi Metals Ltd. is not responsible for the following troubles and damages. Trouble or damage caused by natural disaster or inevitable accident, caused by mishandling, use or storage in an improper place, use out of the rated specifications and modification, factors including contamination and clogging due to the use of corrosive or reactive gasses. Any trouble or damage that is outside of Hitachi Metals Ltd. s control has no responsibility (if it does not clarify where responsibility lies, warranty is to be determined whether or not it costs regardless of the warranty period after deliberation. If you cannot reach the number above please contact Hitachi Metals, Ltd. in Tokyo below. Toll-free 0800-500-5055 (in Japan), Tel.+81-3-6774-3001 Catalog No. HL-K2 Printed in October 16 (T-GT2)