WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468

Similar documents
INSTRUCTION MANUAL. January 23, 2003, Revision 0

Dinghy Racers Parts List

2. Note that the ropes from the rigging board are secured in the cam cleats of the jib fairleads.

OPPI Rigging Guide 3/2008

Slide and Turn System SF35

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

Pressure Dump Valve Service Kit for Series 3000 Units

Methylethycetone (MEC) - PMS 60 polyurethane glue - Grease - White silicone

Rudder Kit Assembly Instructions for Quest 13

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

LITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)

NEW TYPE M PRESSURE RELIEF DEVICE

SEADUCER BOATS GAS MONO COME VISIT US ON THE WEB AT

Pressure Dump Valve Service Kit for Series 2300 Units

A18W35_MASE 130_F_EN MANUAL

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Halsey Taylor Owners Manual STOP!

Declaration of Performance (DOP)

Declaration of performance

// ADapters GUIDelines

INSTRUCTION MANUAL Pressure Relief Device LPT

Now you can remove the 4 screws on the back of the housing to reveal the AFC Diaphragm. One of these is a break off/tamper proof cap screw as well.

Slide and Turn System SF25

#59114 Rola 2-Bike Rack Carrier (Shown Assembled) (A) (C) (B)

E-trike Li Assembly Guide

INSTALLATION INSTRUCTIONS. Parts List. Tools Required. Before You Begin. Installation. Customer Information BICYCLE ATTACHMENT JUL.

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

Pakboats PakCanoe Assembly Instructions

MANUAL REEFING SYSTEMS

A17W23_MASE_MUS_EN MANUAL

L.Ph. Bolander & Sons 1355 Evans Ave. 800/

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

BoatWasher Swede, , MS Float

Wide opening parallel grippers Series CGLN

Vanguard Sailboats 300 Highpoint Avenue Portsmouth, RI For the dealer nearest you call SAIL

Intro: by firechim on October 3, 2013

DURAS INFLATABLE BOAT OWNER'S MANUAL

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

RADIUS ROD BUSHING SET

INSTALLING THE TRIDENT 11, 13 OR 15 RUDDER

Assembly instructions nortik scubi 2 Recreational kayak

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Installation Guide, MPower Echelon Console

CHECK VALVES APPLICATIONS

C 0G 00 N/US

NEW PRODUCTS RANGE

Rapidmain Installation Guide

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

TECH SHEET ORANGE PIVOT TOOL INSTRUCTIONS

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Installation Instructions

Thanks for choosing EJAI SOLAR product

Bladerider X8 Assembly Help Notes

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Section 3- Repair and Calibration Procedures

Parts Manual. Scraper Hitches PH:

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

INSTALLATION GUIDELINES

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

INSTALLING THE PROWLER 13 RUDDER

Chapter 9 Accessories

Coiling Tube with Twist-Proof Fitting

Below are the instructions to build a roller-furling unit for under $10. Read the entire process before beginning the project.

User Manual V14.1 IP68 LED FLEX NEON

EXH. Specifications. Descriptions. Min. working pressure MPa

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

Installation and Training Manual

SIMPLAIR PIPING TOOL. JXT Company

Xtender30. Home Batting Cage. Assembly Instructions

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

INTERLOCKED METAL HOSE

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

TRAVSMART permanent single-cable horizontal lifeline system

Bike holder with three-point-support for mounting stand

GROUTEC SCOTT VICKERS. Grouting Equipment

3/8" Dr. Air Butterfly Impact Wrench

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS

98695A01 - THE CONCEPT OF THE DIVATOR FAMILY

SETTING UP THE MODEL 210B SRA

Step 1: Block sand the transom to remove the seam joint. The end result should be a flat transom without a ledge where the seam joint is.

Operating instructions Pitot Static Tube

PAGE (Rev. A - 06/17)

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

INSTALLATION INSTRUCTIONS

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Assembly Instruction - Triton Vuoksa 2 advanced Touring kayak

tel: fax: web:

K Page 1 of 48 Air Intake - Pg. 17

The following drawings are concerned of this measure, which will be considered in the next revision of the documents as well as in LogiKal.

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

Peinert Dolphin. Assembly

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

Transcription:

Hull Picture Art.. (pipe) or combination Splash guard Stream resistance * Wind tolerance Temperature level of mounting surface Size and hight (mm) Sealable WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467,, 3468 Table 1: The mutual properties of different W allas lead-throughs. Please use this table in choosing the most suitable leadthrough. Applicability () 140 x 73 40 Hull 1066 () () ø 65 4 140 x 73 40 95DU, 95DP, 800, 900, 1000, 90, 100 and 150. 2466 () ø 92 50 Yes 2069 Hull 3468 (2448) Combination 155 x 83 56 Hull 2467 (2448) 3468 (2448) Combination Combination ø 92 19 155 x 83 56 96D, 30D, 40D, 1300, 1800, 2400 and 3200 2069 2460** (2448 or 2428) Combination * Relevant especially in long exhaust pipes. ** 2069 always with Nautic 40D. 1 ø 92 50 Yes 22.4.2002

FEATURES AND RECOMMENDATIONS FOR USE lead-throughs: - lead-throughs are intended primarily for use with Wallas products in which combustion air is not drawn from a suction air pipe located around the exhaust pipe. - lead-throughs may be used in other Wallas products if the suction pipe for the combustion air is cut off before the lead-through. - With devices where the exhaust pipe shall be insulated with a larger diameter metal pipe, the combination lead-through has to be used. - lead-throughs are intended primarily for the following Wallas units: 95DU, 95DP, 800, 900, 1000, 90, 100, 150. - It is possible to use the drainage lock with the exhaust lead-throughs to remove occasional splash water and condensation from the exhaust pipe. - All of the exhaust lead-throughs are stainless steel. - The exhaust lead-throughs fit into the 28 mm exhaust pipe. Standard lead-through: - The standard lead-through may be used as a hull lead-through in rough conditions and as a deck leadthrough in mild and normal conditions. - The standard lead-through has the best splashguard of all Wallas lead-throughs. - The standard lead-through cannot be sealed. For this reason it cannot be used as a deck lead-through, which may be occasionally submerged under water. The standard lead-throughõs splashguard is more effective than using a sealable lead-through in the open position. - The standard lead-through withstands wind well and may therefore be used as both hull lead-through and deck lead-through. - The arched design of the standard lead-through makes it easier, for example, to slide a rope over it. Likewise, a standard lead-through used in the hull will not get caught if the hull comes into contact with a post, for example. 1066 Hull lead-through: - The hull lead-through has a slight flow resistance and thermal effect surrounding it. - The hull lead-through is sensitive to wind; under some circumstances the wind can blow directly into the hole. A strong wind exceeding 15 m/s may shut the unit off. 2466 Sealable deck lead-through: - The sealable lead-through withstands wind well. - The lead-through may be installed into the deck because of its sealability. It is therefore suitable in rough conditions in which the deck may become submerged under water. 2 - Always remember to open the lead-through before turning the unit on and to seal it when sailing conditions become rough. - The lead-through is opened and sealed by simultaneously pressing and turning its cap. - Under exceptionally rough conditions, the use of the deck lead-through upgrade, 2069, is recommended. Combination lead-throughs: - Combination lead-throughs contain both the exhaust and combustion air jacket tube in the same leadthrough. - Combination lead-throughs are intended primarily for Wallas products in which the combustion air is preheated in the suction pipe around the exhaust pipe. - The combination lead-through may also be used in other Wallas units if the splash guard of the fresh air duct is taken care of for example with an insulation pipe which is cut of after a gooseneck. - With devices where the exhaust pipe shall be insulated with a larger diameter metal pipe, the combination lead-through has to be used, although a combustion air is taken otherwise. - Combination lead-throughs are intended primarily for the following Wallas units: 96D, 1300, 1800, 2400, 3200, 30D, 40D. - All combination lead-throughs are stainless steel. - Combination lead-throughs fit the 28 mm exhaust pipes and the 45 mm jacket tube, 2448. 3468 Standard lead-through: - The standard lead-through is suitable for use as a hull lead-through in rough conditions and as a deck lead-through in mild and normal conditions. - The standard lead-through has the best splashguard of all Wallas lead-throughs. - The standard lead-through cannot be sealed. For this reason it cannot be used as a deck lead-through, which may be occasionally submerged under water. The standard lead-throughõs splashguard is more effective than using a sealable lead-through in the open position. - The arched design of the standard lead-through makes it easier, for example, to slide a rope over it. Likewise, a standard lead-through used in the hull will not get caught if the hull comes into contact with a post, for example. 2467 Hull lead-through: - The combination lead-through increases the wind tolerance of the hull lead-through to some extent as long as wind blowing directly into the pipe does not completely offset it. - The thermal effect on the hull of the boat is in all cases minimal, because the suction pipe serves as a thermal insulator.

2460 Sealable deck lead-through: - The sealable lead-through withstands wind well. - Both the suction and exhaust pipes are sealable. The lead-through is therefore suitable for deck installation as it may be occasionally submerged under water in rough conditions. - Always remember to open the exhaust lead-through INSTRUCTIONS FOR INSTALLATION General instructions for installation: - The air current must always be able to flow freely past the lead-through: try to install the lead-through in such a way that enables wind to blow over it. The lead-through must not be located in a corner or behind a closed end where wind pressure can interfere with the functioning of the unit. - The exhaust gas is hot. Always make sure that there is nothing in the affected vicinity of under 200 mm which is sensitive to heat, such as ropes, fenders, or neighboring boats. - If necessary, the exhaust pipe can be insulated to avoid fire hazards. - The exhaust pipe and jacket tube for the suction air must be stainless steel, or 2448. The aluminum pipe, 4045, is sufficient enough to be used with the exhaust lead-through as an insulating tube. - The insulation of the lead-through is recommended to prevent electrochemical corrosion in metal-framed boats. - Using the lead-through as a model when making installation holes for the lead-through is worthwhile, especially with cylindrical lead-throughs. - Lead-throughs have gasket but if necessery insulate the installation hole with silicon, too. - Always check the device specific requirements of the unit before the installation of the lead-through. Common to deck lead-throughs: - All lead-throughs heat their environment. Wooden decks in particular may dry from the heating effect. - Be cautious of the hot surface of the deck leadthrough during use. - Using a drainage lock with the deck lead-through to remove splash water from the exhaust pipe is recommended. The drainage lockõs water pipe can be extended to an appropriate water disposal area, for example, by using a rubber hose. - Making a gooseneck for the exhaust pipe and jacket tube is recommended; the gooseneck must be placed after the drainage lock. Common to hull lead-throughs: - The minimum distance between the hull lead-through and the surface of the water is 300 mm. Make sure that the lead-through is not submerged under water for over 5 seconds. This is especially important in sailboats. 3 before turning the unit on and to seal it again when conditions become rough. - The lead-through is opened and sealed by simultaneously pressing and turning its cap. - Under exceptionally rough conditions, the use of the deck lead-through upgrade, 2069, is recommended. - A deck lead-through upgrade 2069 must be used with Nautic 40D. - Install the lead-through as far back as possible, preferably in the stern. - The hull lead-through must always be equipped with a gooseneck pipe. The highest point on the gooseneck must always be above the water. - If desired, a drainage lock can be mounted onto the exhaust pipe of the hull lead-through. However, the drainage lock must be placed just after the gooseneck. Things to consider when installing standard leadthrough pipes 3476 and 3478: - Standard lead-through pipes can be freely installed to a chosen position. However, in an exemplary installation, the lead-throughs are installed in positions which best suit their function: o When installing in the hull or side of the deck structure, tilt the lead-through slightly towards the rear of the boat. This allows the outer surface of the lead-through to cool both the thermal current flowing through and the wind current. o In a vertical deck installation, tilt the lead-through directly towards the boat. Things to consider when installing sealable leadthroughs 2466 and 2460: - The cap of the sealable lead-through must be loosened when installing. - Use a screwdriver to loosen the cap by pushing the spring into the pipe. Be careful that the screwdriver does not slip when pushing the spring; it is tight. See Figure 1. - When assembling the lead-through, check Figure 1 to make sure the parts are in the right order. Also make sure that the spring goes into the right space in the cap, otherwise the lead-through cannot be sealed. Figure 1: Cap Metal washer Spring Rubber washer Coil spring Base

Figure 2: Standard lead-through installed into the hull for the exhaust gas. The hole for installing the lead-through is 35-45 mm and the screw holes are 2 x 6 mm. min 100 mm min 60 mm Figure 3: Installation for the hull exhaust lead-through, 1066. The installation hole is 35 mm and the screw holes are 4 x 5 mm. min 100 mm Figure 5: Installation for the sealable deck lead-through, 2466. The installation hole is 45 mm and the screw holes are 4 x 6 mm. 74 mm max 25 mm 2466 max 45 mm 8 0 mm 1066 46 mm Reducer 70 mm Figure 4: Standard lead-through installed into the deck for the exhaust gas. The installation hole is 35-45 mm and the screw holes are 2 x 6 mm. When installing the deck lead-through upgrade 2096, a reducer for extremely rough conditions is attached to the lower edge of the upgrade. The lead-through is attached to the upgrade according to Figure 10. 4

Figure 6: Hull installation of the standard lead-through, 3468, for exhaust gas and suction air. The installation hole is 45 mm and the screw holes are 2 x 6 mm. min 60 mm Figure 9: Installation for the sealable deck lead-through, 2460. The installation hole is 45 mm and the screw holes are 4 x 6 mm. 74 mm 3468 2460 max 45 mm Figure 7: Installed hull lead-through 2467. The installation hole is 50 mm and the screw holes are 4 x 6 mm. 2467 74 mm When installing the upgrade 2069 for extremely rough conditions, the deck lead-through is attached to the upgrade. See Figure 10. Figure 10: Sealable deck lead-through, 2460, and deck lead-through upgrade 2069 installed directly onto the heater. Water can easily be splashed into the unit with this method of installation. The installation hole is 60 mm and the screw holes are 4 x 6 mm. 74 mm 2460 max 25 mm Figure 8: installation for standard lead-through, 3468, for exhaust gas and suction air. The installation hole is 45 mm and the screw holes are 2 x 6 mm. max 45 mm 2069 100 mm When installing the deck lead-through directly to the unit without the upgrade 2069, the deck lead-through is attached to the deck like the upgrade piece. 5

ACCESSORIES pipe; 28 mm. 1030 Insulation sleeve for the exhaust pipe; 30 mm. 2096 lead-through 2466 and upgrade 2460 for especially rough conditions. 2448 and suction pipe; 28/45 mm. 2461 Insulation series for circular combination lead-throughs for metal-framed boats (2460, 2467) 2462 Mounting the lead-through 2460 into an older, larger hole. 4045 Aluminum mantle tube, 45 mm, for thermal insulation with the exhaust lead-through. Drainage lock for splash water and condensation in the exhaust pipe. 602308 Insulation series for exhaust lead-throughs for metalframed boats (1066, 2466, ). 602309 Insulation series for standard lead-throughs for metalframed boats (, 3468). In the Figures of these instructions sale-item article numbers are used to refer to the accessories on the list. 6