Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

Similar documents
Engineering Data Sheet

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Manual Actuated Boiler Blowdown Valves

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

INSTALLATION & MAINTENANCE INSTRUCTION

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Installation, Operation and Maintenance Manual for Back Pressure Regulator

SCA Series Inverted Bucket Steam Traps

FLANGED TWO-PIECE BALL VALVES

FLANGED MULTI-PORT BALL VALVES

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

PV4 and PV6 Piston Valves

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

AVM7 Stainless Steel Thermostatic Air Vent

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

Circular Sight Windows

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

INSTRUCTION MANUAL Pressure Relief Device LPT

FLANGED TWO-PIECE BALL VALVES

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

Circular Sight Windows

BCV31 DN20 - Blowdown Control Valve

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

CA10S, CA14 and CA14S Air and Gas Traps

BCV31 DN40 - Blowdown Control Valve

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

Operating instruction

Thermocirc Installation and Maintenance Instructions

L21S/SR/ST Glass Level Gauges

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

TITAN FLOW CONTROL, INC.

BUTTERFLY VALVES Series 800

TP1 and TP2 Temporary Cone Shaped Strainers

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

APT14, APT14HC and APT14SHC Spares 2

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

DelVal Flow Controls Private limited

Sterile Visual Flow Indicator

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Installation & Operation Manual Proven Quality since 1892

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

INSTALLATION, OPERATION and MAINTENANCE MANUAL

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

MUD 1. Vent check valves. Instruction and maintenance manual.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

PC3_ and PC4_ Pipeline Connectors

Installation, operation & maintenance manual - original version

PENBERTHY SERIES LC FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Operating and maintenance manual Filter and reducing station Series / 1.0

Flat Glass Gages. Series 300L, 20, 32, 40, L10. Installation, Operation & Maintenance Instruction Manual

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Type BBS-03, BBS-05, BBS-06, BBS-25

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Sight Flow Indicators 300# & 600# ANSI Models:

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Translation of the original Operating Instructions for HKS rubber compensators

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

AVC32 Carbon Steel Air Vent for Steam Systems

Installation, Operation, and Maintenance Manual

TSS21 Sealed Thermostatic Steam Tracer Trap

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

BCVi43 Blowdown Control Valve

DCV6 Disc Check Valve

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

Telefon (+45) Telefax (+45)

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Transcription:

Klinger Italy S.r.l Via De Gasperi, 88 20017 Rho, Mi - Italy Tel. +39 02 93333.1 Fax +39 02 93901312/3 www.klinger.it Telephone: +61 (08) 9350 1100 Facsimile: +61 (08) 9358 6200 ABN 95 008 679 838 Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25 TYPE R 25. I.O.M No FCA 005 Last Modified: 14/04/2008 Pag 1 of 14

CONTENTS Operating Principle - Page 3 Safety Instructions - Page 4 Storage Instructions - Page 5 Installation - Page 5 Commissioning - Page 7 Tightening Procedure - Page 8 Maintenance Instructions - Page 9 Release Procedure - Page 11 Spare Parts / Important information - Page 12 R 25 Components and Materials - Page 13 Spare Part Details - Glasses, Gaskets and Joints - Page 14. I.O.M No FCA 005 Last Modified: 14/04/2008 Pag 2 of 14

OPERATING PRINCIPLE Klinger reflex level gauges are used to indicate the level of liquids in boilers and vessels. Reflex glass (3), is installed between of the centre piece (1) and the cover plate (2). In conjunction with the sealing gasket (4) and cushion joint (5) it seals the liquid and vapour contained within the reflex level gauge and prevents release of media to atmosphere. The enclosed sealing gasket and cushion joint ensure perfect sealing. The liquid level can be viewed through a slot in the cover plate. The side of the reflex glass exposed to the medium has prismatic right angled grooves. Rays of light penetrating from the outside are absorbed into the liquid filled area but are completely reflected in the vapour area within the reflex level gauge, due to their different refraction indices. Therefore the liquid filled area retains the colour of the medium, whereas the vapour filled area appears silvery. For steam applications, the liquid filled space appears black and the vapour filled space appears silvery. Water Filled Area of Gauge Vapour Filled Area of Gauge. I.O.M No FCA 005 Pag 3 of 14

SAFETY INSTRUCTIONS To ensure the safe operation of your Reflex level gauge the following must be complied with at all times. Before installation, check to ensure that the operating conditions i.e. pressure and temperature, do not exceed the maximum operating pressure and temperature limits of the model of reflex level gauge being installed. The rating of the level gauge will be stated on the type plate and must not be exceeded. Level gauges must be installed in accordance with the Installation, Operation and Maintenance Manual. The installation, operation and maintenance should only be carried out by qualified personnel. Ensure that all connecting pieces are tightened on assembly and after carrying out maintenance. When opening and closing drain cocks, media will be discharged from the level gauge chamber. Care should be taken to ensure that personnel working in the area will not come into contact with the media, as it may be under pressure and at elevated temperatures. Do not release any nuts/bolts on pressure tightening parts, unless following instructions as defined in the Installation, Operation and Maintenance Manual. Before conducting any maintenance activities on either the level gauge or the isolation valves/cocks, ensure that the level gauge has been isolated, the internal pressure has been completely removed and that the temperature of the gauge permits safe manual handling. When taking a reading or checking the operation of a Reflex level gauge, or any other type of glass gauge, it is mandatory that the operator does not approach the level gauge unless they are wearing suitable eye protection. Pag 4 of 14

STORAGE INSTRUCTIONS FOR KLINGER REFLEX LEVEL GAUGES AND SPARE PARTS. Gauges and their respective spare parts must be stored in clean, dry, storage facilities. Fully assembled gauges should be stored in the packaging as supplied. Spare parts for the gauges should be handled with care and stored in their original packing. The ambient temperature in the storeroom must be between -20 C. and + 50 C. Sudden changes in temperature should be avoided (the danger of condensation / water). It is recommended to take protective measures if the parts are stored under dusty conditions. To avoid mistakes in spare part identification, all parts should be marked according to the delivery documentation and stored in the appropriate place. Instructions for handling and use are enclosed with each shipment. Store these instructions along with the parts lists and other documentation for future reference. Spare part lists will help identify Klinger spare parts for maintenance purposes. Any damage due to inappropriate storage will release Klinger from any obligation derived under warranty, guarantee and/or product liability. INSTALLATION Standard Klinger Reflex level gauges of type R 25 are typically supplied with either an isolation valve or a gauge cock set to isolate the level gauge from the pressure vessel or storage tank. RAV valves are an offset metal seated isolation valve with an integral safety ball which is available in the following configurations Connection to the Vessel ( Standard configuration listed others available on request ) Flanged DN 15, 20, 25, PN 40 1/2", 3/4", 1", ANSI 150-300-600 1 1/2" ANSI 150 DN 15, 20 PN 64-100-160 Threaded Pag 5 of 14

INSTALLATION Connections to the level gauge ½ NPT union nipple ( Rotatable ) or ½ NPT nipple ( Non rotatable ) AB18 DG and AB18 D Gauge Mount sets are also supplied as standard with safety balls in top and bottom mount. Gauge cock sets are supplied as standard with a ½ drain cock. Connection to the Vessel ( Standard configuration listed others available on request ) Flanged DN 15, 20, 25, PN 40 1/2", 3/4", 1", ANSI 150-300-600 1 1/2" ANSI 150 DN 15, 20 PN 64-100-160 Threaded Connections to the level gauge AB18 DG ½ NPT nipple, non rotatable. AB18 D 16 mm End tube with gland ring and union nut rotatable. Refer to the appropriate Installation, Operation and Maintenance Manual for the type and configuration of isolation valve/cock to be installed with the level gauge. When installing the level gauge, special attention must be paid to the alignment of the connecting flanges, as this is extremely important to ensure the reliability and safe operation of the installed level gauge. The maximum dimensional tolerance between centres and transversal alignment must not exceed 1.5 mm. Flanges must also be in the same plane with a maximum misalignment of 1.5 mm. (This data should be checked prior to installation.) Use only suitable lifting and handling devices. Do not stress critical points when lifting e.g. valve hand wheel. Only competent workers should execute handling and lifting operations. Pag 6 of 14

COMMISSIONING Minimisation of thermal shock to gauge glass. Thermal shock considerably affects the life and performance of the glasses. Where a complete Plant is being commissioned, the gauge cocks/isolating valves are left in the open position to minimise thermal shock. Where the gauge has been isolated for maintenance while the rest of the plant is operating under temperature and pressure, the following procedure is recommended to bring the gauge back into service. 1.1 With the top and bottom cocks/valves shut, open-the drain cock and then crack the top cock/valve to allow a small flow of vapour to pass through the gauge chamber, until working temperature is attained. 1.2 Close the drain cock. 1.3 Open the top gauge cock/valve fully and allow the gauge to fill with liquid. 1.4 Open the bottom gauge cock/valve fully. 1.5 During the commissioning period, the covers and the joints could settle and it is essential therefore to follow up all clamping nuts to maintain the required torque values. For correct bolt torque sequence refer to the tightening procedure. Additionally the joints and glands should be tightened on the gauge cocks/valves (see appropriate maintenance sheet for correct procedure). Bolt Torque at Ambient Temperatures Klinger Level Gauge R 25 Bolt Torque 30 Nm Pag 7 of 14

TIGHTENING PROCEDURE Select the appropriate tightening sequence to be followed based on the actual level gauge glass size. Some level gauges are supplied with an even number of spaces between the tightening bolts and others are supplied with an odd number of spaces between the tightening bolts. The number of bolts used is governed by the glass length of the level gauge. When replacing glass in a reflex level gauge it is critical that bolts are tightened with a torque wrench in the correct sequence shown, the torque being increased incrementally until the final torque value has been obtained. Note :- You must ensure that the final torque value is applied evenly to all bolts, this may require a number of tightening cycles at the final torque value as the gaskets settle. R25 20Nm 30Nm. I.O.M No FCA 005 Last Modified: 14/04/2008 Pag 8 of 14

MAINTENANCE INSTRUCTIONS Any leaks which appear during service should be stopped immediately by following up at the appropriate point. Gauge see commissioning procedure. Cocks or Valves see appropriate maintenance sheet. Changing Glasses 1. Dismantling 1.1 Isolate the gauge from the source of pressure. 1.2 Relieve the gauge of internal pressure. 1.3 Isolate and remove ancillary equipment (see appropriate maintenance sheet). 1.4 Loosen the tightening bolts in the correct sequence, as shown in the release procedure. 1.5 Remove tightening plate from the gauge (supporting covers and internals). 1.6 Remove the cover plate, glasses and joints from the centre piece. 1.7 Clean joint faces of the centre piece and cover plate, making sure that they are free of any remnants of the joints. Take care not to damage the joint face of the centre piece. 1.8 Inspect joint faces of the centre piece. Check and ensure that surface is clean and straight with no signs of damage to the sealing face. 2. Assembly 2.1 Fit a new Reflex glass with new joints, (never re-use joints which have already been in service!) 2.2 Reassemble all the components in the correct sequence. 2.2.1 Sealing joint between centre piece and reflex glass. 2.2.2 Reflex glass must be installed with grooves towards the centre piece 2.2.3 Cushion joint between cover plate and reflex glass. 2.3 Tighten the tightening bolts to the prescribed torque following the tightening procedure. Lubricate threads of the tightening bolts with Molykote thread grease 1000. 2.4 Never grip the level gauge body in a vice during the assembly process, assembly on a flat clean surface. 3. Refurbishing. 3.1 No refurbishing should be necessary other than the replacement of glasses and joints.. I.O.M No FCA 005 Last Modified: 14/04/2008 Pag 9 of 14

Exploded View - R 25 Level Gauge Pag 10 of 14

RELEASE PROCEDURE Select the appropriate release sequence to be followed, based on the actual level gauge glass size. Some level gauges are supplied with an even number of spaces between the tightening bolts and others are supplied with an odd number of spaces between the tightening bolts. The number of bolts used is governed by the glass length and the pressure rating of the level gauge. Pag 11 of 14

SPARE PARTS / IMPORTANT INFROMATION Use only original Klinger replacements parts. Cleanliness is most essential when assembling, and all directions listed under changing glasses must be observed. Draughts or adverse weather conditions may cause thermal shock, resulting in glass breakage. If there are windows, lift doors, etc in the vicinity it is advisable that the gauge should be screened off. If the level gauge is installed outdoors the glass should be sheltered from rain, hail and cold Glass corrosion if the glasses have become opaque or liquid level definition deteriorates, the glasses should be examined, cleaned and if worn, replaced at once. Protective shields can only be fitted to transparent level gauges they must never be fitted to reflex level gauges. It is recommended that one complete set of glasses and joints be kept for spares and a new set ordered as soon as these are used. When ordering please quote the type and size of the gauge e.g. R 25 - VII as stated on the gauge type plate. Pag 12 of 14

R 25 COMPONENTS AND MATERIALS Components Materials Spare FS/H M/H parts 1 Centre piece ASTM A105N AISI 316 2 Cover plate Fe 430 Fe 430 3 Reflex glass Borosilicate * 4 Sealing gasket Klinger Graphite SLS * 5 Cushion joint KLINGERSIL C-4430 * 6 Hexagon head set screw 8.8 8.8 7 Tightening plate Fe 430 Fe 430 Pag 13 of 14

SPARE PARTS DETAILS GLASSES, GASKETS AND JOINTS FOR R 25 Reflex Glass, type A Size II III IV V VI VII VIII IX L 140 165 190 220 250 280 320 340 Sealing gasket and cushion joint, type A Size II III IV V VI VII VIII IX L 140 165 190 220 250 280 320 340 L1 115 140 165 195 225 255 295 315 Pag 14 of 14