Hydraulic Reservoirs for Mobile Equipment: A Primer

Similar documents
Copyright, 2005 GPM Hydraulic Consulting, Inc.

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Unit 24: Applications of Pneumatics and Hydraulics

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

TECHNICAL DATA. Q = C v P S

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

TECHNICAL DATA. Q = C v P S

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Hydraulic Punch Drivers

TECHNICAL DATA. Q= Cv S

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Right-Angle Tube Roller Model

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TITAN FLOW CONTROL, INC.

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Air Eliminators and Combination Air Eliminators Strainers

Air Amplifiers & SYSTEMS

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

TROUBLESHOOTING GUIDELINES

Oxygen Usage Best Practice Guide

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Flexible Metal Hose Products

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

SHOP WELDED TANKS STANDARD CONNECTIONS

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

TECHNICAL DATA OBSOLETE

VACUVENT Valve functions - benefits - flowpath - VG series - Sewage

Unit 24: Applications of Pneumatics and Hydraulics

Pressure Sensing Valve - Model 4023

COMPRESSED AIR DISTRIBUTION SYSTEMS

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

(Refer Slide Time: 2:16)

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

COATINGS SPRAY GUIDE Urethane 520

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Air Operated Hydraulic Pumping Systems to 50,000 psi

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Related Products: Auto Drain Valve. Model/Specifications. Model

Moving Fluids Concept and Theory

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Introduction. Part one: Identify the Hydraulic Trainer Components

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

BACK PRESSURE / SUSTAINING

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Pilot Check Valve: Metal Body Type

MUD 1. Vent check valves. Instruction and maintenance manual.

DS/PI-14 DIAPHRAGM SEAL TEMPERATURE ERROR

Simplicity in VRU by using a Beam Gas Compressor

Series IRV1000/2000/3000

OWNER S TECHNICAL MANUAL

VACUUM REGULATORS CONTENTS

TITAN FLOW CONTROL, INC.

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

MF2M Monnier Miniature Compressed Air Filter

VBS-9263 Series. Application. Features. Applicable Literature

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

BACK PRESSURE / SUSTAINING

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FV Flash Vessel Installation and Maintenance Instructions

Workshop Compressors CLASSIC Series

GM Series Dual-Block Multi-Function Gas Control Valves

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

HORIZONTAL BLADDER TANK

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

VB-7263 Series. Application. Features. Applicable Literature

SCA Series Inverted Bucket Steam Traps

TECTYL 1422S APPLICATION PROCEDURES AND TROUBLESHOOTING GUIDE

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Transcription:

Keith Ellefsen, The IFH Group The primary function of hydraulic reservoirs is to serve as storage containers for hydraulic fluid. If properly designed, they can also function as fluid conditioning devices. That is, they not only provide fluid to meet varying demands as actuators extend and retract, but can also prepare the fluid for its next working cycle. DESIGN CONSIDERATIONS Mobile hydraulic reservoirs are expected to perform as well as industrial reservoirs, even though they are typically operating under more extreme and often adverse conditions. Applications include, but are not limited to, combines, heavy terrain forklifts, earth boring equipment, boom cranes, grounds keeping equipment, end loaders and hay bailers, as well as military applications. So, they require special design considerations. Two examples of the special problems designers of hydraulic reservoirs used in mobile equipment face are machine motion and extreme ambient temperatures. However, the most significant problem to overcome is the limitation in size. Size is the most striking difference when comparing industrial and mobile designs. Industrial standards, developed by NFPA (National Fluid Power Association) and accepted by ANSI (American National Standards Institute), specify that reservoir capacity should equal 3x to 12x maximum pump output. However, size and weight limitations may require the equipment to operate with reservoirs as small as the volume the pump discharges in a single minute. Because of the special limitations of mobile hydraulic reservoirs, they typically require custom design. Custom-made hydraulic reservoirs have an advantage over off-the-shelf reservoirs because they can be designed to fit the exact space and technical requirements necessary for optimal performance. Cost, size, and weight can be minimized while maintaining performance and efficiency. 3D G R O U P Hydraulic Reservoirs for Mobile Equipment: A Primer modeling can be used to develop the most efficient design for the application and for manufacturability. If the design is too complex, manufacturability is compromised and the cost is higher. CALCULATING DRAWDOWN The amount of fluid a reservoir must make up is equal to the total drawdown, which equals the areas of the cylinder rods multiplied by their respective strokes. The sum total for all cylinders is equal to the volume of fluid the reservoir must provide. Drawdown calculations are critical: there should be enough fluid left in the reservoir at maximum drawdown to provide a reasonable residence time for fluid passing through the tank. Residence time gives the contaminants a chance to settle out and air bubbles to coalesce. A good rule of thumb is to fix total capacity at one-third of maximum pump output at drawdown. THERMAL EXPANSION This must be considered when sizing a reservoir. Fluid expansion between the time a reservoir is filled with cold fluid and when the fluid reaches maximum operating temperature must be accounted for. Care should be taken to avoid overfilling when servicing reservoirs. Reservoir oil levels should be checked with all cylinders retracted. To calculate thermal expansion, use a coefficient of volume expansion of 4.5 x 10-4. The coefficient multiplied by the volume in cubic inches of fluid undergoing the temperature change and the change itself in F will yield the volume change due to heating or cooling. VENTED OR PRESSURIZED RESERVOIR? Should a vented or pressurized reservoir be specified? The key deciding factors are the location and inlet requirements of the pumps. In many mobile applications, the fluid level of the reservoir is below pump inlet. In response to pump inlet line 1

losses, the pump may cavitate i.e., form small liquid-free zones such as bubbles or voids. Collapsing voids that implode near to a metal surface cause cyclic stress through repeated implosion. This results in surface fatigue of the metal, causing a type of wear called cavitation. Because inlet vacuum may require pump de-rating, the reservoir can be pressurized to maintain maximum pump performance. RESERVOIR PRESSURIZING METHODS There are three ways to pressurize a reservoir on most mobile construction equipment: 1. Use the regulated air from the machine s pneumatic system, if there is one. This is probably the most effective way. 2. Contain the air within the reservoir clearance volume (above the fluid) and depend on thermal expansion of the fluid to compress the air and pressurize the reservoir. 3. Tap pressurized air from the scavenge pump of a two-cycle diesel engine. A reservoir pressure cap ensures that pressure is contained within the tank and relieves excess pressure when the cylinders are retracting, so it returns more oil to the tank than the pumps are demanding. The cap must also have low pressureovershoot characteristics. CALCULATING WALL STRESSES When a reservoir is pressurized, its wall stresses must be calculated. However, wall stresses should also be calculated for a vented tank. High stresses develop quickly in large areas of flat plate, and deflections can become large due to the weight of the fluid. If peripheral equipment such as ladders or air tanks are added to reservoirs, plate thickness and the need for stiffeners should be considered. Careful placement of baffle plates can provide needed support without costly additional weight. Mounting brackets and access cover mounting flanges can also provide stiffness when carefully placed. BAFFLE DESIGN Baffles direct, diffuse and contain fluid, and increase tank stiffness. (Figure 1.) To help cool return fluid, it should be directed toward the outer walls of the reservoir. The fluid should also flow across magnets provided to intercept ferrous particles. Return flow should never be aimed at a fluid intake line. SUCTION QUADRANT BAFFLES RETURN QUADRANT FIGURE 1 Internal baffles separate reservoirs into various sections or quadrants. Some fluid mixing without agitation is desirable. Diffusing the fluid throughout the tank ensures there are no dead spots where fluid might collect. Flow velocities across any baffle should be no more than one foot per second or less. Fluid must not cascade from one level to another within the tank. This can be caused by differences in fluid levels between two areas separated by either a poorly designed baffle or multiple-level tank bottom. When sizing baffles or any component in the return portion of the tank, provide for maximum return flow. Assume that the cylinder of the largest area ratio (cylinder cap end area head end area) is being retracted at full flow: return flow will exceed pump output. Return diffusers and filters should also be sized to handle this flow. 2

RETURN FLOW VELOCITIES, DIFFUSERS Return line velocities on mobile equipment usually exceed 10 ft./sec. It is best to size return manifolds and/or plumbing adjacent to the reservoir to reduce this velocity to 5 ft./sec. or less. Return line diffusers help reduce flow velocities and provide fluid mixing without agitation. Diffusers commonly reduce flow velocities to 1 ft./sec. or less. Many types are commercially available. However, fitting the ends of return lines with 40%-open-area perforated metal works well. (Figure 2.) When possible, return lines should have ends cut at 45º and be directed toward the outside wall. RETURN FLOW return filters, while more difficult to plumb, keep contamination outside the tank and are more easily accessible for servicing. OTHER CONTAMINATION CONTROLLERS To increase the effectiveness of the reservoir as a contaminant controller, dams and suction strainers can be added. As indicated earlier, magnets will only remove ferrous particles. Particle dams, (Figure 3) placed between the return and suction areas of the tank help contain heavier particles that may have bypassed the return filters. Dams commonly consist of an angle plate that extends across the floor of the tank. The dam should be high enough to contain particles until the reservoir is routinely cleaned and low enough not to cause cascading. Dams also provide ideal mounting surfaces for magnets. SUCTION BAFFLE RETURN PERFORATED METAL MAGNETS FIGURE 2 Diffusers reduce velocity of return flow. Note angle cut on return line is directed toward outside wall for more efficient cooling of return oil. INTERNAL VS. EXTERNAL FILTERS Return filters are often placed inside the tank to save space and provide integral diffusion. One advantage of in-tank return filtration is that filling the tank through the filter helps ensure system cleanliness. However, be sure to install return filters so that contaminants will not fall into the reservoir when an element is changed. Placing filters within the tank provides a neat looking design but may introduce contamination to an area where it is difficult to remove. External DAM FIGURE 3 A particle dam restricts movement of large particles in the reservoir. Magnets remove ferrous particles. In mobile equipment, pumps are usually located at or above fluid level and far away from the tank. These conditions sometimes create a high inlet vacuum (greater than 5 in. Hg) and prevent the use of pump inlet contamination control. Where positive pump inlet conditions can be provided (as 3

with a charge pump), suction strainers or filters should be considered. These are a last chance form of pump protection. Cold startup and ambient operating conditions should also be considered when sizing suction filters, if pumps cannot be disengaged during startup. travel up the ramp formed by the screen while the fluid passes through. Care must be taken when selecting the angle and the amount of open area to ensure the passage of cold fluid. DE-AERATION SCREEN COMBATING CORROSION Hydraulic reservoirs in mobile equipment can be prone to corrosion when humid air is drawn in when the oil level drops. Once moist air gets into the reservoir, water can condense on the interior walls when the ambient temperature drops. Desiccant breathers can be specified to filter and dry ambient air drawn into the reservoir. However, the desiccant has a finite service life, so if the breather is not changed at recommended intervals, moisture will be drawn in unimpeded. The condensate, ultimately, will enter the hydraulic system and pose several problems. The condensate will also adhere to the interior surfaces of the reservoir, which could lead to rust deposits that can also enter the hydraulic system. These deposits can cause problems of their own, including premature wear to components, clogging of filters and orifices, and valve malfunctions. Reservoirs made of aluminized steel can help prevent corrosion if moisture does get into the reservoir. Aluminized steel does have some thickness limitations. ENTRAINED AIR Small bubbles of air entrained in the fluid when drawn through a pump become pressurized and implode, rebounding a jet of fluid outward at pressures in excess of 50,000 psi, along with extremely high local temperatures. These fluid jets can chip bits of metal from surrounding surfaces. Screens of expanded or perforated metal, called deaeration screens, placed in the reservoir at an angle are effective in removing air bubbles from fluid. (Figure 4.) When fluid containing air bubbles is directed through the angled screen, the bubbles FIGURE 4 An angled de-aeration screen removes entrained air from liquid. DESIGNING INLET LINES There should be a smooth transition from the low velocity of the fluid in the reservoir to the pump inlet lines. Velocities in pump inlet lines should not exceed 5 ft./sec. in large lines. For any given flow velocity in two different size lines, pressure drop is greater in the smaller line because of increased fluid shear area. Cutting the end of pump inlet lines inside the tank at an angle and pointing the mouth downward provides a larger throat area and helps prevent vortexing (like a small whirlpool) and cavitation. Also, to avoid vortexing, place the tube under a greater depth of oil, or add vanes to the throat of the tube extending outward. RESERVOIR MATERIALS Mobile hydraulic reservoirs are typically manufactured from steel, stainless steel or aluminum. Another option is aluminized steel. Aluminized steel is sheet carbon steel that is hotdip-coated on both sides with an aluminum-silicon 4

alloy to avoid the contamination problems inherent to uncoated steels. Essentially, aluminized steel combines the corrosion resistance of aluminum with the higher mechanical strength and lower cost of steel. Aluminized steel reservoirs are compatible with virtually all petroleum-based and synthetic fluids while also providing protection from atmospheric corrosion. FIGURE 5 Reservoirs from 18 gallons to 12 gallons fabricated from aluminized steel are hot-dip-coated on both sides with an aluminumsilicon alloy to avoid the contamination problems inherent to uncoated steels. RESERVOIR FABRICATION With any hydraulic reservoir, the quality of the weld is all-important. Any competent manufacturer should combine MIG, TIG, robotic and electrical resistance welding to provide hydraulic reservoirs of the highest quality. Manufacturing equipment should be state-of-the-art, including CNC turret, FMS and LNC lasers, punches, CNC controlled forming equipment and CNC controlled welding equipment. As far as the finish is concerned, powder coating should be seriously considered. Increasingly stringent environmental regulations, rising costs in all areas, and demands for better quality and more durable products make it the smart choice for a better looking, more durable finish. The main difference between a conventional liquid paint and a powder coating is that the powder coating does not require a solvent to keep the binder and filler parts in a liquid suspension form. The coating is typically applied electrostatically and is then cured under heat to allow it to flow and form a skin. It creates a hard finish that is tougher than conventional paint. FIGURE 6 Tank and fill necks manufactured at The IFH Group being powder sprayed. CLEANING AND MAINTENANCE Reservoir servicing must also be taken into account. There must be provisions to drain both return and suction areas of the tank, especially if a dam is used to separate them. Pipe couplings are often used, but SAE O-ring ports provide better sealing. Valving should also be provided for closing off inlet lines when replacing pumps or other components that are below fluid level. Access must be provided for cleaning and maintaining the interior of the tank. Hatches should be large enough for service personnel and cleaning tools. There should also be a means for lighting each portion of the tank for inspection. Hatches should be attached to the tank so leaks can be detected and repaired from the outside. SHIPPING AND INSTALLATION When mounting the reservoir, consider the dynamic nature of the mobile equipment: bouncing over rough terrain or at highway speeds can put high impact or fatigue loading on tank walls. When mounting a tank by the corners, stresses can be distributed through the side plates by placing angles in the corners. 5

All reservoirs should be delivered clean and pressure-tested. The manufacturer should be able to provide powder coating, chemical agent resistant coating and sub-assemblies such as fill caps, filter breathers, sight gauges, sending units, hoses and fittings such as brackets or tube fittings everything from a simple two-part tank strap to more than 60 different components as well as onsite design and assembly assistance. Keith Ellefsen is President, The IFH Group, Rock Falls, Illinois 6