RC 195 Receiver-Controller

Similar documents
Powers Controls RC 195 Single Input Receiver-Controller

Powers Controls RC 195 Multiple Input Receiver- Controller

Powers Controls D Day-Night Thermostats

Model 130M Pneumatic Controller

4150K and 4160K Series Wizard II Pressure Controllers and Transmitters

P-5215 Differential Pressure Transmitter

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

C1 Series Pneumatic Controllers and Transmitters

RP920A-D Modular Pneumatic Controller

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Model 4000 Pressure Controller

Fisher C1 Pneumatic Controllers and Transmitters

OPERATING AND MAINTENANCE MANUAL

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

DPC-30 DPC-100. Reference Manual

Float Operated Level Controllers

GM Series Dual-Block Multi-Function Gas Control Valves

4194 Series Differential Pressure Indicating Controllers

Electropneumatic Transducer (I/P) Installation, Operation and

PBT1100 POWER BANDING TOOL

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection

DS06D,G Dial Set Pressure Regulating Valve

Operation Manual Piston Sensed Gas Pressure Regulators

Model: 43T. Bermad Pressure Relief Valve

64 Series Pressure Reducing Regulators

WIKA INSTRUMENT CORPORATION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

DS05C,D,G Dial Set Pressure Regulating Valves

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

The Ins and Outs of I/P Transducers

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Pressure Independent Control Series

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Techcon Systems TS1254 Pressure Pot

Design DSA Steam-Atomized Desuperheater

Bermad Pressure Reducing. Model: 42T

VACUUM REGULATORS CONTENTS

INSTALLATION AND OPERATING INSTRUCTIONS

SUPER PRECISION AIR RELAYS

MANUAL BE SERIES Test Benches

Fisher 4194 Differential Pressure Indicating Controllers

1. ABOUT THE PRODUCT:

SERVICE MANUAL No. I-0043

GM-7000 Series CE Approved Gas Control Valve

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type 4660 High-Low Pressure Pilot

D05 Pressure Regulating Valves

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Pressure Dump Valve Service Kit for Series 2300 Units

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

H-DIL Hydrogen/Oxygen Sample-Draw Detector Operator s Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

[Instruments for vacuum measurement, checking and adjustment] 3

Installation Instructions

KOBOLD KSM FLOWMETER. User Instructions

Design Features. General Description

Tex-914-K, Calibrating Motorized Gyratory-Shear Molding Asphalt Press

SUPER PRECISION AIR RELAYS

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Installation, operating and maintenance Instructions for Seemag bypass level indicator

KF Series (Field Mount type) Pressure (Temperature) Indicating Controller. Model: KFP, KFT. User s Manual

C645A-E Pressure Switches

Fisher DVI Desuperheater Venturi Inline

Bubble Tube Installations

Preferred Instruments Danbury, CT USA

Installation and User Manual

PVQ 13 A2 R SE 1 S 20 C-11 D

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

TECHNICAL DATA. Q = C v P S

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

RAM 4021-DPX Operation Manual

PAPR Flow Tester. instructions. part no WARNING

TECHNICAL DATA. Q= Cv S

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

Document How to Set Single Stage Press Pressures

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Installing a Probe. Typical Installation

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ACV-10 Automatic Control Valve

SSL. Smart Valve Positioner.

Transcription:

Document No. 129-082 RC 195 Receiver-Controller Product Description The POWERS RC 195 Receiver-Controller is a pneumatic instrument that receives one, two or three pneumatic inputs. It produces a pneumatic control signal based on the net pneumatic input and the mechanical settings, such as setpoint, percent proportional band and authority. Product Numbers Product Number Table 1. Control (Output) Pressure Gauge Stick-On Scale Dispenser For Setpoint Dial 195-0001 None English/Standard International Units 195-0003 0 to 30 psig/ 0 to 200 kpa English/Standard International Units Troubleshooting Before troubleshooting the operation of the RC 195 Receiver-Controller, ensure that: 1. The supply pressure at the unit is 22 psi 152 kpa). 2. All transmitter inputs being used are between 3 to 15 psi (21 to 103 kpa). 3. Only one restrictor supplies each transmitter. 4. The transmitter calibration is correct. Accessories Restriction Repair Kit, includes 195-066 Four restriction plates and gaskets Connector Kit, includes 195-067 Two connectors, one 2-barb and One 3-barb (for 1/4 O.D. plastic tubing) RC 195 Input Pressure Simulator 195-099 Two gauge/switch assemblies Terminal Strip 195-082 (for ten 1/4 O.D. plastic tubes) Scale Conversion Card (Single) 125-1661 Scale Conversion Card (Pkg. of 25) 144-022 Setpoint Dial Sheets 195-130 (See POWERS CONTROL RC195 Multiple Input Receiver-Controller Technical Instructions 155-036P25 or the Powers Controls Catalog for scale ranges.) Receiver Gauges a variety of 1-1/2 inch (38mm), 2-1/2 inch (64mm) and 3-1/2 inch (89mm) diameter receiver gauges are available to monitor transmitter input signals. Request GA 142-2 Receiver Gauges (155-023P25) from your nearest Siemens Industry, Inc. office. RC Calibration Slide Rule 153-054 Table 1. Troubleshooting Checklist. Complaint Check Probable Cause Corrective Action Control pressure stays at approximately zero Control pressure stays at approximately supply pressure Rotate setpoint adjustment screw counterclockwise Rotate setpoint adjustment screw clockwise Pressure increases Pressure remains unchanged Pressure decreases Pressure remains unchanged Transmitter sensing medium which is above (R.A.) or below (D.A.) the proportional band RC 195 out of calibration None Recalibrate Replace Pilot Relay Plugged Pilot Relay Restrictors Restrictors Receiver-Controller is defective Replace Receiver-Controller Transmitter sensing medium which is above (D.A.) or below (R.A.) the None proportional band RC 195 out of calibration Recalibrate Receiver-Controller is defective Replace Receiver-Controller Item Number 129-082+2, Rev. EA Page 1 of 5

Installation General 1. The RC 195 Receiver-Controller may be mounted in any position on any vertical surface. Two integral mounting tabs accept a No. 8 or No. 10 screw. Small vibrations, such as those from an air handling unit, will not affect the operation of the instrument. Cover removal The cover furnished with the RC 195 is self-locking to the instrument body. To remove the cover, pull cover to the right and lift then pull cover to the left and lift. To put the cover back on, put it in place and press down until it latches. 2. Generally, 1/4-inch (6.4 mm) O.D. plastic tubing should be used for all the connections to the plug-in air connectors. Larger size tubing will reduce the pressure drops, but they will increase time delays. Conversely, smaller tubing will reduce time delays, but will increase pressure drops. 3. The RC 195 requires a clean, dry, oil free supply of compressed air. It is recommended that an AF 908 In-Line Air Filter be located in the supply line to the RC 195. A maximum of two RC 195 Receiver-Controllers can be supplied by a single AF 908 In-line Air Filter. 4. Whenever possible, the RC 195 equipment should be used with a constant air supply. The RC 195 Receiver-Controller and transmitter are calibrated at the factory with a 22 psig air supply. If a constant air supply is not available, use a remote restrictor and separate air supply to transmitters. Changing the supply pressure to the RC 195 Receiver-Controller system from 22 psig to either 18 or 25 psig can shift the control point by as much as 2% of scale. Once the instrument is secured and proper tubing connections are made, the cover can be removed for access to internal restrictors, percent authority adjustment, percent proportional band adjustment, the setpoint dial and the setpoint dial adjustment. Restrictors Figure 2. 1. Restrictors are factory installed in all inputs of the Receiver-Controller. Restrictors are in the "OUT" position as shipped from the factory. NOTE: When an internal restrictor is required, the restrictor must be moved to the "IN" position. Use the following procedure when dialing to a new restrictor position: a. Loosen both screws two full turns. b. Move the restrictor lever back and forth, between the full travel limits, a minimum of two times or until there is no sensation of "drag" against the lever. This will allow the gasket to return to its proper position. c. Retighten both screws with the restrictor lever fully in position against its stop. Do not over-tighten the screws. Screws should be tight enough to provide a good seal without warping the restrictor assembly. d. See Accessories for Replacement Restrictor Kit part number. 2. When an input is not being used, the restrictor should be in the "OUT" position and the input connection should be open to atmosphere. Page 2 of 5 Figure 1. Dimensions.

Installation, Continued Figure 3 gives the maximum recommended distances for using the internal restrictor, external restrictor and remote gauges. If the maximum distances are exceeded, there will be excessive pressure drops and time delays which will produce faulty indication and unsatisfactory operation. Setpoint adjustment The output pressure at setpoint can be adjusted by simply rotating the setpoint adjustment screw until the desired pressure is reached. The setpoint dial has a 3 to 15 psi (21 to 103 kpa) scale. One of the stick-on scales provided with the unit may be placed on the dial to match the #1 or #2 input transmitter range. Each scale is marked D.A. (Direct Acting) or R.A. (Reverse Acting) to match the required action of the receiver-controller. To determine the authority setting, the proportional band setting, and setpoint setting, see the control diagram (or the setting on the instrument being replaced). Technical Instructions RC 195-1 gives detailed information on how to calculate the percent proportional band setting, the percent authority setting, and setpoint conditions. Calibration Figure 3. Proportional band (sensitivity) The proportional band setting is adjustable from 2 to 20% of the primary input scale based on a control pressure change of 5 psi. The proportional band setting selected depends on the characteristics of the system under control; this setting is normally a value which will result in satisfactory control without short cycling (too low percent PB) or hunting (too high percent PB). Authority adjustment The authority slide provides a means of adjusting the ratio of the change of the #1 (or #2) input pressure to the change of the #3 input pressure for the same control pressure change. Input connections #1 and #2 have fixed authorities with respect to each other equal to 100%. Input connection #3 has an adjustable authority with respect to inputs #1 and #2 which, by means of authority slide, may be varied from 20 to 200%. The authority adjustment is required only when input #3 is used. Receiver-Controller Simulator A tool designed to simplify the calibration and set-up of the RC 195 receiver-controller is available. The RC 195 simulator (Product Number 195-099) can simulate two transmitters (one-pipe) and indicate their corresponding simulated pressures. Procedure 1. Set the proportional band pointer to value shown on the control diagram. 2. Set the authority pointer to value shown on the control diagram. Figure 4. RC-1 Control Diagram. 3. Connect 22 psi supply air to port "S". 4. Connect pressure gauge to port "C". Page 3 of 5

Installation, Continued 5. Apply setpoint pressures to inputs and, with a screwdriver, turn the setpoint adjustment screw until control pressure reaches 8 psi (55 kpa) or midpoint pressure between spring range of actuator. 6. Calibrate the setpoint dial by pulling it up, turning it to agree with the transmitter input and then releasing it. 7. Turn the setpoint adjustment screw until the dial agrees with control diagram. 8. For two input applications, setpoint conditions are equal to the midpoints of the reset schedule. References RC 195-1 Operation and adjustment information 155-036P25 GA 142-2 Receiver Gauges 155-023P25 RC 195-3 RC 195 Simulators 155-103P25 Figure 5. 9. For manual control point adjustment (CPA), connect gradual switch to input 1 or 2, set switch to 9 psi (62 kpa), and then calibrate controller as in Steps 5 through 8 above. Calibrating in this manner will allow equal increase or decrease in control point when the bleed type positioning switch is used. 10. Once the sensor-controller system is completely installed and sensor(s) have been calibrated, some tuning of the control loop may be required. If output continuously cycles, increase percent proportional band. If hunting (large offset) is present, decrease percent proportional band. NOTE: Whenever the proportional band or authority settings are changed, the setpoint dial must be recalibrated. The installation is now complete. Page 4 of 5

Receiver-Controller Cross Reference Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. POWERS CONTROL is a registered trademark of Other product or company names mentioned herein may be the trademarks of their respective owners. 2015 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel. +1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com Document No. 129-082 Printed in the USA Page 5 of 5