RTG 25. Introduction

Similar documents
RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Pressure ranges and accuracy classes for outlet pressure and safety devices

Dival 500 Pressure Regulators

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Slam Shut Valves SCN

RESIDENTIAL REGULATORS

Self-operated Pressure Regulators for special applications

Safety Shut-off Valve SSV

Pilot HON 630a, HON 640

OPERATING INSTRUCTIONS

1805 Series Relief Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Pressure Regulator 133 / 233

Dival 600. Pressure Regulators

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Norval Pressure regulator

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Norval Pressure Regulators

Aperval Pressure Regulators

CASH VALVE TYPE KP BACK PRESSURE VALVES

Pressure regulators. Introduction. TR Head. 3 ways body Dival

1800CPB2 Service Regulators

Precision and Instrument Regulators 1/4" port size

627 Series Pressure Reducing Regulators

RR 16 Commercial & Industrial Regulator

RB 4700 Commercial & Industrial Regulator

PRESSURE REGULATORS. Type A/140. Process Management TM

Precision pressure regulators LRP/LRPS

Gas Pressure Regulator HON 270 MK2

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

MEGR-1627 Instruction Manual

Model 1800 PFM Series Regulator. Technical Bulletin

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

PRESSURE REGULATORS. Type B/240. Process Management TM

Actuator HON 670 / 671

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

1800C and 1800C-HC Service Regulators

1305 Series Pressure Reducing Regulators

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

64 Series Pressure Reducing Regulators

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

ASX 176 Axial Pressure regulator

PRESSURE REDUCING VALVE RP45 (EN)

1805 Series Relief Valves

RR 16 Commercial & Industrial Regulator

Gas Pressure Regulator HON 200

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

PRO-50 Instrument Supply Regulator

Types S100K and S102K Pressure Regulators

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

ALF400 to 900, ALT-5/-9

1800CPB2 Pilot-Loaded Service Regulators

Gas Pressure Regulator HON 300

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

T208VR Series Tank Blanketing Vacuum Regulator

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

SHANGHAI FIORENTINI GAS EQUIPMENT CO.LTD.

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

MT-239-E ENGLISH PRESSURE REGULATOR STAFLUX MINI TECHNICAL MANUAL INSTALLATION, COMMISSIONING AND MAINTENANCE INSTRUCTIONS

Pressure Regulators. Aperflux 101

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Regulator from 1800 B series

Safety Cut-Off Valve HON 305

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Type R622 Pressure Reducing Regulator

PRESSURE REGULATOR LBM SERIES

Fuel Filters DN15 DN25. elektrogas.com DE

Gas Pressure Regulator HON 502

MEGR-1912 Instruction Manual

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Slam Shut Valves SBC 782

Chlorinator. MODEL C-731 (Floor Mounted)

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

776 Cryogenic Safety Valve

Reflux 819/FO. Pressure Regulators

Pressure Reducing Valve for Steam Type 2333 A

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Noth American 7347 High Pressure Gas Regulators

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Tank Blanketing Pressure Regulators RHPS Series

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

MODEL 240 GAS PRESSURE REGULATOR

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Type 99 Pressure Reducing Regulators

S300 Series. Valve Link. Features. Fisher Controls

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

VALVES HIDROMATIC VALVE.

Safety Relief Valve HON 835

Art PRESSURE REDUCER

GAS PRESSURE REGULATORS AP

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

North American Orifice Metering System

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

C 10 Pressure Reducing Valve

Transcription:

Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations. RTG 25 pressure regulator is used for reducing and regulating the pressure of natural gases (SR 3317-2003) or of other non-corrosive gases (LPG, air). Figure 1 - RTG 25 regulator 2

RTG 25 regulator operation The upstream (inlet) pressure enters the regulator body via the inlet connection. The pressure is regulated by modifying the distance between the seat (7) and the valve plate (12), which results in different passage sections. The downstream (regulated) pressure is applied by means of the impulse connection under the control diaphragm (5), generating a force that opposes the force exerted by the spring (2). A change in the downstream pressure creates an imbalance in the system, determining the valve plate (12) to open proportionally with the flow required by the consumer. In the rated operation conditions (constant inlet pressure, constant flow rate), the system comprising the spring, diaphragm, rod and valve plate is in balance. Modifications in one or more parameters produce an imbalance in the system, which moves until reaching another balance position. The set value of the outlet pressure can be changed by means of the adjustment nut (1). The nut acts on the spring (2) modifying the pre-tensioning force. Figure 2 Main components of RTG 25 1. Adjustment nut 7. Seat 13. Obturator 2. Adjustment spring 8. 1/8 plug 14. Separation diaphragm 3. Relief nut 9. Rod 15. Diaphragm disk 4. Relief spring 10. G1 plug 16. Relief connection 5. Control diaphragm 11. Metering point 17. Protection cover 6. Diaphragm seat 12. Valve plate 3

If the outlet pressure increases accidentally over the set value, the force generated by the pressure under the control diaphragm (5) overcomes the force exerted by the relief spring (4) and the assembly comprising the control diaphragm (5) and the diaphragm disk (15) moves. The pressure excess is vented into atmosphere via the relief connection (16). The regulated pressure can be measured by means of the metering point (11) which is located on the exterior of the body. The metering point is mounted optionally. Technical characteristics Design features: Fail open type Balanced plug Incorporated relief valve Maintenance without removing the regulator from installation Incorporated stainless steel filter (9000 mm 2 ) Table 1 The main technical characteristics of the RTG 25 regulator Inlet pressure Pe [bar] 0.02 2; 0.05 6 Regulator Shut-off valve Relief valve Operating conditions Nominal flow rate (Pe = 200 mbar) [Nm 3 /h] 10, 20, 35 Setting range Pa [mbar] 10 70 Regulation class (AC) ± 5 10% Lock-up pressure class (SG) + 20% Intervention range [mbar] minimum 10 40 maximum 30 125 Intervention accuracy (AG) - minimum up to 5% - maximum up to 2.5% (depending on the control pressure) Relief range Pd [mbar] 10 50 over Pa Intervention accuracy (AG) ± 10 % Ambient temperature [ C] -30 80 Working fluid temperature [ C] -20 60 Working medium Normal, no corrosive agents RTG 25 pressure regulators are manufactured in the following constructive variants: RTG 25 basic variant; RTG 25 SB variant with incorporated shut-off valve; RTG 25 DB variant with DB safety shut-off device for lack of feeding; RTG 25 SB DB variant with shut-off valve and safety shut-off device for lack of feeding. 4

Materials Item Body Cover Connection Seat Diaphragm Gasket Material Die-cast aluminium Die-cast aluminium Steel/brass Brass Rubber Rubber Safety devices and optional accessories RTG 25 pressure regulator is supplied with the following safety devices and accessories: impurity filter the second impurity filter placed at the regulator inlet in order to retain impurities present in the natural gas. It is optionally supplied in case the regulator is not equipped with a shut-off valve; metering point - provided for measuring the outlet pressure; shut-off valve (SB) blocks the gas flow at outlet pressure increase or decrease; thermal shut-off valve (HTB) blocks the gas flow in case the gas temperature at regulator inlet reaches 90 100 C; safety diaphragm covers the working diaphragm and prevents gas leaks in case the diaphragm is damaged. It limits gas leaks into atmosphere to less than 30dm 3 /h; safety shut-off device for lack of feeding (DB) blocks the gas flow through the regulator in case the inlet pressure is absent or decreases significantly or when the outlet flow rate is exceeded; 1 st stage regulator - is of direct acting type, fail open, provided with balanced plug. The functioning of the pressure regulator is based on balancing the force generated by the set pressure with pressing force generated by the adjustment spring. The adjustment spring reduces the inlet pressure to the constant pressure of 0.25 bar. Figure 3 1 st stage regulator 5

Shut-off valve operation The shut-off valve Figure 4 that is mounted optionally on RTG 25 regulator is a safety device which intervenes if the outlet pressure (Pa) increases or decreases in an uncontrolled manner. In normal operation conditions, the shut-off valve is open. The diaphragm seat (32) together with the control diaphragm (29) retains the rod (35) by means of the balls (22). If the outlet pressure is within the maximum and minimum set values of the shut-off valve, the diaphragm seat (32) does not move. Figure 4 Shut-off valve 18. Cover 19. Maximum nut 20. Upper cover 21. Maximum spring 22. Balls 23. Diaphragm upper disk 24. Valve plate 25. Valve plate holder 26. Seat 27. Blocking spring 28. Lower cover 29. Diaphragm 30. Ball chamber 31. Cam 32. Diaphragm seat 33. Minimum spring disk 34. Minimum spring 35. Rod If the outlet pressure exceeds the valve set value at overpressure or decreases under the valve intervention value at pressure drop, the diaphragm (29) and implicitly the diaphragm seat (32) move, allowing the balls (22) to release the rod (35). Under the action of the spring (27), the rod moves and the contact between the valve plate (24) and the seat (26) blocks the gas flow. 6

Safety shut-off device for lack of feeding (DB) operation A decrease in the inlet pressure or an increase in the gas consumption determines the regulator to open further. At a certain point, the obturator (13) (Figure 2) reaches the upper edge of the seat (7) preventing the gas flow through the regulator. The safety device is armed automatically: the small bypass orifice (25 30 dm 3 /h) in the seat (7) of the DB device determines the outlet pressure to increase up to the initially set value. When the closing pressure is reached, the valve plate (12) seals on the lower edge of the seat (7), therefore the obturator (13) is released. Figure 5 - Detail of RTG 25 DB with automatic arming Sealing is possible when there are no active users and the installation downstream from the regulator is tight. If the regulator is equipped with a safety device (DB), the minimum shut-off valve (SB) is not necessary anymore. Adjustment springs Regulator RTG 25 Spring code Setting range [mbar] 1450151 10 25 1450152 20 35 1450153 25 40 1450154 40 70 Maximum spring Code Setting range [mbar] Shut-off valve Minimum spring Code Setting range [mbar] 1450288 30 54 1450230 10 40 1450289 40 125 7

Performance curves for natural gas Performance curve RTG 25 Q 10 Outlet pressure [mbar] Flow rate [Nm 3 /h] Performance curve RTG 25 Q 20 33 Outlet pressure [mbar] 31 29 27 25 23 21 +20 % +10 +5% -5% -10% 19 17 15 0 10 20 30 40 50 60 70 Flow rate [Nm 3 /h] 8

Overall dimensions RTG 25 Figure 6 Overall dimensions of RTG 25 without shut-off valve Figure 7 Overall dimensions of RTG 25 equipped with shut-off valve 9

Packing dimensions Code Pcs [no] Size [cm] Volume Weight [m 3 ] [kg] Pallet L l h [cm] 120 80 170 Pcs [no] Weight [kg] Volume [m 3 ] RTG 25 Q10 1 20 17 24 0.008 2.77 180 495 515 1.63 RTG 25 Q20 1 20 17 24 0.008 2.77 180 495 515 1.63 RTG 25 Q35 1 20 17 24 0.008 2.77 180 495 515 1.63 10

The manufacturer reserves the right to make modifications without any prior notification. CT No. 123 / 2009 / 01 TOTALGAZ INDUSTRIE Nr. R.C.: J-22-3277/1994 CUI: RO6658553 IBAN: RO28BRDE240SV13842272400 B.R.D. G.S.G. Iaşi Şos. Păcurari, nr. 128, Iaşi, cod 700545, România Tel. : 0040-232-216.391(2) Fax : 0040-232-215.983 E-mail: office@totalgaz.ro Web: www.totalgaz.ro Certified Management System