Electro-Magnetic Flowmeters Electromagnetic Sensor

Similar documents
ABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

9700 Transmitter Submersible hydrostatic level transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

ProcessMaster FEP610 Electromagnetic flowmeter

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

200A Series ELECTRONIC LEVEL TRANSMITTER

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pro-V Multivariable Flowmeter

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Deep Submersible Level Transducer Series 300DS

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

Level transmitter LT 100

Integral type Differential pressure flowmeter VNT Series

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification

Autocalibration Systems For In Situ Oxygen Analyzers

780S Ultra High Purity Series

Micro Motion 7812 Fiscal Gas Density Meter

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

FPD175 Compact orifice carrier assembly

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

GA24 Technical Datasheet

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

High-performance submersible pressure transmitter For level measurement Model LH-10

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

North American Orifice Metering System

Liquid level instruments BM 24 /BM 51

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS880 (retrofit kit) 4/275. Overview

Pilot valves for pilot operated servo valves

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

S261 Remote seals with capillary tube

Installation Manual , Rev BB December Micro Motion H-Series Hygienic Coriolis Flow and Density Sensors

Design Features. General Description

Vol. IX, No. 8

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

GUKO FDA. einfach. gut. beraten.

ASIC-Based Small Bore Submersible Level Transducer

Materials : Dichromate zinc plated steel flanges

WHEATLEY Series 500 Swing Check Valve

Turbine Flowmeters for Gas Applications

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Turbine Flowmeters for Gas Applications

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

INSTALLATION AND OPERATING INSTRUCTIONS

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

CAPITAL CONTROLS SERIES NXT3000

Dissolved Oxygen Cartridge Electrode Systems

Ford Service Saddles and Tapping Sleeves

Homestead Series 820 AWWA Butterfly Valves

Air Eliminators and Combination Air Eliminators Strainers

GILMONT ACCUCAL FLOWMETERS

For Multi-Parameter Meters see mvx

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Flow Sensors & Hydrometers Specification Sheet

Turbine Flowmeters for Gas Applications (Metric)

Torque Tube TB300 Digital Transmitters

Modbus Submersible Level Transducer

Materials : Dichromate zinc plated steel flanges or AISI 316

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Magnetic level switch type MR783 Instruction Manual

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

PRO-50 Instrument Supply Regulator

Pressure Measurement Single-range transmitters for general applications

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

How to specify a product. Process Sensors and Mechanical Instruments

Dissolved Oxygen Systems

Electro-Pneumatic Converter YT-940 SERIES

ProcessMaster FEP610, HygienicMaster FEH610 Electromagnetic flowmeter

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Flow metering in gases Introduction to COMBIMASS family

Turbine Flowmeters for Liquid Applications

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Transcription:

Data Sheet (US) Electro-Magnetic Flowmeters Electromagnetic Sensor MagMaster TM Plus MFF Unrivalled, fully traceable flow performance 0.15% accuracy Operable flow range: 1500:1 ensures more precise revenue measurement superior control of process accurate night-flow measurement Bi-directional system Pulsed DC technology incorporates benefits of AC systems. Submersible and buriable inherently suitable for use in flooded environments eliminates meter vaults and promotes very low installation costs Designed, manufactured and calibrated to internationally accepted standards ISO 9001/UKAS(NAMAS)/NIST/NATA ensures reliable, maintenance-free operation 2-year warranty as standard Built-in grounding electrode eliminates requirement for grounding rings MagMaster Plus MFF Electromagnetic Sensor 8 to 84 inch (200 to 2200 mm) meter sizes. Larger upon request CalMaster enabled product NSF approved liner material available

Setting the Standard MagMaster TM Plus sets new standards for accuracy, reliability and low cost of ownership. This enhanced range, available in sizes 8 in (200 mm) to 84 in (2200 mm), is designed specifically for use on many diverse applications. The MagMaster utilizes pulsed DC technology coupled with the benefits of AC design. Unrivalled Flow Performance MagMaster Plus sets the standard for flow measurement performance. The combination of sensors with ultra-linear magnetics, new technology transmitters and a next generation sensor drive and signal processing system, results in unrivalled flow performance. High accuracy and an operable flow range of 1500 : 1 enables reliable and accurate measurement over the widely varying flow rates which occur in a typical distribution system. Particularly important is that previously unregistered minimal night flow rates can now be accurately metered. In addition, the absence of moving, wearing components and MagMaster s unique design ensure that the calibration remains stable in the long term. Submersible and Buriable All MagMaster sensors have a rugged, robust construction to ensure a long, maintenance-free life. The sensors are, as standard, inherently submersible (IP68, NEMA 6P), thus making them suitable for installation in vaults and metering pits which are liable to become flooded. A unique feature of MagMaster sensors is that they are buriable. Installation merely involves excavating to the underground pipe, fitting the sensor, cabling back to the converter and then backfilling the hole. No metering vaults or pits are required, and the overall low cost installation is simple and fast. Assured Quality MagMaster Plus is designed and manufactured in accordance with international quality procedures (ISO 9001) and all flowmeters are calibrated on nationally traceable calibration rigs to provide the end user with complete assurance of both quality and performance of the meter. An indication of the quality is the two year warranty which is offered as standard on the MagMaster Plus. MagMaster TM is a trademark of ABB Inc. MagMaster Flowmeters 2

GENERAL SPECIFICATION Capacity Table Size Flow Range (US g/min) in. mm. Minimum Maximum 8 200 3.73 4,974 10 250 5.83 7,771 12 300 8.39 11,190 14 350 11.4 15,230 16 400 14.9 19,890 18 450 18.8 25,180 20 500 23.3 31,090 24 600 33.5 44,760 28 700 45.6 60,920 30 750 52.4 69,930 32 800 59.6 79,560 36 900 75.5 100,700 40 1000 93 124,300 42 1050 112 150,400 48 1200 134 179,000 54 1400 182 243,700 58 1500 208 279,700 66 1600 238 318,300 72 1800 302 402,800 Pressure Limitations: < 1800mm (72"): as flange rating. Unbonded PTFE: > 0.5 psi (Do not use Unbonded PTFE if there is a chance of a vacuum occuring in the pipeline.) Recommended Mating Pipe Conditions: Upstream: 5 to 10 diameters straight pipe depending on performance requirements and upstream disturbance. Downstream: 2 to 3 diameters straight pipe depending on performance requirements and downstream disturbances. Maximum based on 33fts 1, but instrument capability in excess of 50fts Environmental Protection (when installed): Rating: Sensor with Integral Converter: NEMA 4X/IP65 Sensor with Remote Mounted Converter: IP68/NEMA 6P (to 33ft (10m) depth) with potted terminal box. (All remote mounted sensors are supplied with potting compound for sealing on site or can be ordered with cable potted and connected to sensor.) Buriable: 3ft (1m) to 16ft (5m) depth (to top of sensor). Mounting: Directly into pipeline at any orientation. Electrodes cannot be in vertical plane. Flow must be up if installed in a vertical pipe. Accuracy: For system accuracy information, see specification sheet of appropriate signal converter. Materials Item Lining Electrodes Flanges Grounding Rings Housing Material Teflon Unbonded (PTFE), Teflon Bonded (FEP), Elastomer (chlorobutyl rubber), Polyurethane, Neoprene, or NSF 61 approved Elastomer Stainless Steel 316, Hastelloy C, Titanium, Tantalum, or Platinum/Iridium (slurry calibration available for first three) Carbon Steel Stainless Steel 316, 12 inches or less Stainless Steel 304 > 12 inches ABS Plastic: up to 24 inches Fabricated Steel (no gaps and painted): 26 to 84 inches Tube Lined Stainless Steel 304 Transmitter/Sensor Separation: < 330ft (100m) 3

SENSOR DIMENSIONS (nominal) 200 to 600 mm (8 to 24in) ANSI Class 150 Flanges Dimensions in. (m m ) Approx. Meter Weight Size C in. (mm ) A B kg lb (w ith liners) 8 (200) 15.6 (396) 15.8 (402) 13.8 (13.8) 37 81 10 (250) 16.9 (430) 17.3 (440) 17.7 (450) 60 132 12 (300) 18.1 (461) 18.9 (480) 19.7 (500) 70 154 14 (350) 20.2 (513) 20.5 (520) 21.7 (550) 100 220 16 (400) 22.4 (570) 22.7 (576) 23.6 (600) 115 253 18 (450) 24.9 (632) 24.7 (627) 27.5 (698) 160 352 20 (500) 27.0 (686) 26.7 (679) 30.2 (768) 217 455 24 (600) 30.4 (772) 30.3 (770) 36.1 (918) 315 693 End Mating Connections: ANSI Class 150 (< 24 inch) ANSI Class 300 (< 24 inch) AWWA Class B AWWA Class D Temperature Ranges: TERMINAL BOX DIMENSIONS (Mounted on Sensor) 4

SENSOR DIMENSIONS (nominal) Notes : 1. Elastomer & Neoprene liners are full face diameter. 2. Add grounding ring to overall length (including gaskets). Flange Data - Inches (mm) Sensor (Nom.) Flange Type A B C (No. Holes) D E (Bolt Circle) 28 (700 ) AWWA Class B 36.5 (927) 0.89 (22.5) 28 1.38 (35 ) 34.0 (863.5) 28 (700 ) AWWA Class D 36.5 (927) 1.32 (33.5) 28 1.38 (35 ) 34.0 (863.5) 30 (750 ) AWWA Class B 38.7 (984) 0.89 (22.5) 28 1.38 (35 ) 36.0 (914.5) 30 (750 ) AWWA Class D 38.7 (984) 1.32 (33.5) 28 1.38 (35 ) 36.0 (914.5) 32 (800) AWWA Class B 41.7 (1060.5) 0.94 (24) 28 1.61 (41) 38.5 (978) 32 (800) AWWA Class D 41.7 (1060.5) 1.50 (38) 28 1.61 (41) 38.5 (978) 36 (900) AWWA Class B 46.0 (1168.5) 1.00 (25.5) 32 1.61 (41) 42.0 (1066) 36 (900) AWWA Class D 46.0 (1168.5) 1.63 (41.5) 32 1.61 (41) 42.0 (1066) 40 (1000 ) AWWA Class B 50.7 (1289) 1.00 (25.5) 36 1.61 (41 ) 47.2 (1200 ) 40 (1000 ) AWWA Class D 50.7 (1289) 1.63 (41.5) 36 1.61 (41 ) 47.2 (1200 ) 42 (1050) AWWA Class B 53 (1346) 1.14 (29) 36 1.61 (41) 49.5 (1257) 42 (1050) AWWA Class D 53 (1346) 1.75 (44.5) 36 1.61 (41) 49.5 (1257) 48 (1200 ) AWWA Class B 59.5 (1511) 1.26 (32 ) 44 1.61 (41 ) 56.0 (1422.5) 48 (1200 ) AWWA Class D 59.9 (1511) 1.77 (45 ) 44 1.61 (41 ) 56.0 (1422.5) 54 (1400) AWWA Class B 66.3 (1683) 1.38 (35) 44 1.89 (48) 62.4 (1584) 54 (1400) AWWA Class D 66.3 (1683) 2.13 (54) 44 1.89 (48) 62.4 (1584) 60 (1500) AWWA Class B 73.0 (1854) 1.38 (35) 52 1.89 (48) 69.3 (1759) 60 (1500) AWWA Class D 73.0 (1854) 2.24 (57) 52 1.89 (48) 69.3 (1759) 66 (1600 ) AWWA Class B 80.0 (2032) 1.65 (42 ) 52 1.89 (48 ) 72.0 (1830.5) 66 (1600 ) AWWA Class D 80.0 (2032) 2.50 (63.5) 52 1.89 (48 ) 72.0 (1830.5) > 72 ( 1800) AWWA Class B Will Advise > 72 ( 1800) AWWA Class D Will Advise Dimensions - Inches (mm) Approx. Weight G (Nominal) H (Overall) J K L Size lb (kg) 28 (700 ) 27.6 ( 700 ) 18.5 (470) 31.6 (803) 20.2 (512) 28 (700) 945 (430 ) 30 (750 ) 30.0 ( 762 ) 19.3 (490) 34.0 (864) 21.3 (542) 30 (750) 945 (430 ) 32 (800 ) 31.5 ( 800 ) 19.9 (507) 35.6 (905) 22.2 (563) 32 (800) 945 (430 ) 36 (900 ) 35.4 ( 900 ) 23.0 (584) 40.4 (1026) 24.6 (624) 36 (900) 1190 (540) 40 (1000) 39.4 (1000) 26.0 (662) 44.4 (1128) 26.5 (674) 40 (1000) 1585 (720) 42 (1050) 42.0 (1067) 29.1 (740) 46.4 (1179) 27.6 (700) 42 (1050) 1930 (880) 48 (1200) 47.2 (1200) 33.1 (840) 52.4 (1332) 30.5 (776) 48 (1200) 2160 (1000) 54 (1400) 55.1 (1400) 40.6 (1030) 60.3 (1532) 34.5 (876) 54 (1400) 3190 (1450) 60 (1500) 60.0 (1524) 44.1 (1120) 64.3 (1634) 36.5 (926) 60 (1500) 3000 (1370) 66 (1600) 63.0 (1600) 45.4 (1154) 68.3 (1736) 38.6 (980) 66 (1600) 4400 (2000) > 72 (1800) 83.9 (2130) Will Advise 72 (1800) 5280 (2400) Note: See previous page for Terminal Box dimensions. 5

Options (specity as separate item on order) Cable Sensor/Transmitter (List number of feet) Standard STT3350 (for cable pricing see 10D9000) Submersible-Waterproof STT3500 (for cable pricing see 10D9000) Magmaster Plus MFF Remote/Integral 8" to 84" Standard Product= Code MFF 1 : Calibrated Bore Size' 8 in. (200mm) 201 10 in. (250mm) 251 12 in. (300mm) 301 14 in. (350mm) 351 16 in. (400mm) 401 18 in. (450mm) 451 20 in. ('500mm) 501 24 in. ( 600mm) 601 28 in. (700mm) 701 30 in. (750mm) 761 32 in. (800mm) 801 36 in. (900mm) 901 40 in. (1000mm) 102 42 in. (1050mm) 112 48 in. (1200mm) 122 54 in. (1400mm) 142 60 in. (1500mm) 152 66 in. (1600mm) 162 72 in. (1800mm) 182 80 in. (2000mm) 202 84 in. (2200mm) 222 2 : End Connections ANSI B 16.5 Class 150, fully rated carbon steel (8 to 24 in. only) (Note: 1) 3 Flanged ANSI Class 300 compatible, Fully rated, (8 to 24 in. only) (Note: 1) K AWWA Class D, fully rated, 28 inch and larger, carbon steel (Note: 2) V 3 : Lining Materials Teflon Bonded FEP ( 8 inches) (Note: 3) 3 Teflon Bonded FEP ( 10 inches) (Note: 4) 3 Teflon Bonded FEP ( 12 inches) (Note: 5) 3 Teflon Bonded FEP ( 14 inches) (Note: 6) 3 Teflon Bonded FEP ( 16 inches) (Note: 7) 3 Elastomer (chlorobutyl rubber) (Note A ) 4 Polyurethane (8 to 24 in. only) (Note: 1) 6 Polyurethane (greater than 24 in.) (Note: 2) 6 Neoprene 8 Teflon Unbonded PTFE ( 8 inches) (Note: 3) A Teflon Unbonded PTFE ( 10 inches) (Note: 4) A Teflon Unbonded PTFE ( 12 inches) (Note: 5) A Teflon Unbonded PTFE ( 14 inches) (Note: 6) A Teflon Unbonded PTFE ( 16 inches) (Note: 7) A Elastomer NSF61 approved E 4 : Electrodes 316 Stainless Steel (Standard) 1 Hastelloy C 2 Titanium 3 Tantalum 4 Platinum / Iridium 5 Tungsten, Carbide Coated (Slurry only) 6 Treated Titanium, Slurry Calibration 8 316 Stainless Steel, Slurry Calibration A Hastelloy C, Slurry Calibration B 6

MFF Code 5 : Sensor Construction General Purpose (non-fm/csa Approved) (Note B) 1 6 : Options None 0 8 in.grounding Ring (one piece) (Note: 3) 1 10 in. Grounding Ring (one piece) (Note: 4) 1 12 in. Grounding Ring (one piece) (Note: 5) 1 14 in. Grounding Ring (one piece) (Note: 6) 1 16 in. Grounding Ring (one piece) (Note: 7) 1 18 in. Grounding Ring (one piece) (Note: 8) 1 20 in. Grounding Ring (one piece) (Note: 9) 1 24 in. Grounding Ring (one piece) (Note: 10) 1?24 in. Grounding Ring (one piece) (Note: 2) 1 8 in. Grounding Ring (two piece) (Note: 3) 8 10 in. Grounding Ring (two piece) (Note: 4) 8 12 in. Grounding Ring (two piece) (Note: 5) 8 14 in. Grounding Ring (two piece) (Note: 6) 8 16 in. Grounding Ring (two piece) (Note: 7) 8 18 in. Grounding Ring (two piece) (Note: 8) 8 20 in. Grounding Ring (two piece) (Note: 9) 8 24 in. Grounding Ring (two piece) (Note: 10) 8?24 in. Grounding Ring (two piece) (Note: 2) 8 7 : Calibration Standard 3-point, no pressure test A 8-point, no pressure test B Special, consult Warminster Factory 9 CalMaster 1 Fingerprint w/std 3-point calibration & no pressure test I 8 : Unused Unused 00 9 : Glanding Conduit entry: 0.5 in. NPT - order cable and length per OPTIONS 4 Conduit entry: 0.5 in. NPT - cable fitted and potted - order cable and length per OPTIONS (Note: 11) 8 10 : Transmitter Type Sensor built for integral mounted MagMaster Converter (? 16 in. only) (Note: 12) EH Sensor built for Remote MagMaster converter ER Instruction Manual (One copy supplied with order at no charge) IM/MAGMAS Note 1: Not available with Calibrated Bore Size' code 701, 761, 801, 901, 102, 112, 122, 142, 152, 162, Note 2: Not available with Calibrated Bore Size' code 201, 251, 301, 351, 401, 451, 501, 601 Note 3: Not available with Calibrated Bore Size' code 251, 301, 351, 401, 451, 501, 601, 701, 761, 801, Note 4: Not available with Calibrated Bore Size' code 201, 301, 351, 401, 451, 501, 601, 701, 761, 801, Note 5: Not available with Calibrated Bore Size' code 201, 251, 351, 401, 451, 501, 601, 701, 761, 801, Note 6: Not available with Calibrated Bore Size' code 201, 251, 301, 401, 451, 501, 601, 701, 761, 801, Note 7: Not available with Calibrated Bore Size' code 201, 251, 301, 351, 451, 501, 601, 701, 761, 801, Note 8: Not available with Calibrated Bore Size' code 201, 251, 301, 351, 401, 501, 601, 701, 761, 801, Note 9: Not available with Calibrated Bore Size' code 201, 251, 301, 351, 401, 451, 601, 701, 761, 801, Note 10: Not available with Calibrated Bore Size' code 201, 251, 301, 351, 401, 451, 501, 701, 761, 801, Note 11: Not available with Lining Materials code A Note 12: Not available with Calibrated Bore Size' code 451, 501, 601, 701, 761, 801, 901, 102, 112, Note A: Suitable for potable water (Approved FDA Material) (UK WFBS, United Kingdom Water Fittings Bylaws Scheme Note B: All meters in this series are General Purpose. No hazardous area approvals available. 7

Notes ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com/instrumentation The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (6.23.08) ABB 2006, 2008 (US) ABB Inc. 125 East County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 8