Service Sink Faucets

Similar documents
Heavy Duty Commercial Supply Stops

AIR GAP (AG) Low Hazard High Hazard

Backflow What is it? City Water. Boiler. Make-Up Water Line

CROSS REFERENCE PARTS LIST T & S

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

Cross Connection Control. 2 CE Hours

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Flow Material Length. Weight GPM LPM. Style 3095

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

HORIZONTAL BLADDER TANK

Water Pressure Reducing Valves

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

. Cross Connections 1

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

553 Series.

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489

PRO SINK -R 1 and 2. Dilution system CONTENTS

THE PERFECT PRESSURE DROP TRAP PRIMER

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

Aquor House Hydrant V2

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

Engineering Excellence. Installation Guide

VERTICAL BLADDER TANK

ASSE International Product (Seal) Listing Program

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

ELKHART BRASS MANUFACTURING COMPANY

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

REDUCED PRESSURE ZONE DEVICES SERIES PRODUCT CODES OPERATION HIGH HAZARD RATING. 15mm - 50mm FEATURES APPLICATION DESCRIPTION

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Smart Water Application Technologies (SWAT) TM

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Sterisil Ac+ Installation & Operating Manual

VB-7263 Series. Application. Features. Applicable Literature

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

PRESSURE REGULATOR GUIDE

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Product Catalogue. July We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

ACCREDITED. Technical specifications series

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

BARRICADE 286 AIRLINE FILTERS

sensible sophistication

DUAL CHECK VALVES 2NV20-20F PRODUCT CODES OPERATION LOW HAZARD RATING. 20mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

VB-7273 Series. Application. Features. Applicable Literature

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

DS05C,D,G Dial Set Pressure Regulating Valves

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

OPERATING INSTRUCTIONS

Presented to the IAPMO Standards Review Committee on March 7, 2016

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

UltRo Dual Flow Reverse Osmosis Water System

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Full Range Pressure Compensating Variable Flow Control

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

D05 Pressure Regulating Valves

Decorative Accessories Guide

REGISTRATION EXAMINATION, JUNE 2017 CERTIFYING PLUMBER ANSWER SCHEDULE

Environmental Services Buller District Council 4-6 Brougham Street PO Box 21, Westport 7866 Telephone

VOLUMATIC WATER REGULATOR

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

36H SERIES Combination Gas Valve

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8" TO 3-1/ ROUG VALVE OPTIONS 1/2" NPT 1/2" NOM or 1/2" NOM or

QUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

ASSE International Product (Seal) Listing Program

22. Specialty Valves.

Twin & Triple Control Concealed Thermostatic Shower Valve

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

VBS-9263 Series. Application. Features. Applicable Literature

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

Combination Air Valve Model

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

INSTALLATION & MAINTENANCE INSTRUCTIONS

J Air and Water Kit Instructions Part# 02584

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

Ligature Resistant Head

Series 58 SAFETY VALVES 312

Decorative Accessories Guide

Combination Air Valve

Water Temperature Control - Groups of Fixtures

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

Transcription:

Service Sink Faucets

Heavy-Duty Service Fittings Faucets in janitorial and maintenance sink locations are subjected to more abuse than any other faucet in your facility. Their exposure to chemicals and other contaminants can also create a significant backflow hazard to the potable water in your building. Choosing the right faucets for service sink locations is extremely important there isn t a better choice than Chicago Faucets. Our service sink faucets are engineered for high-use, high-abuse commercial applications and feature: Heavy-duty, solid cast brass construction for unsurpassed durability A choice of atmospheric and continuous pressure spill resistant vacuum breaker spouts to cover all service sink applications Vacuum breakers integrated into the spout to help reduce backflow risk Top-mounted wall bracket that provides extra stability and doesn t interfere with filling floor-standing buckets Renewable Quaturn operating cartridges for dependable operation and easy maintenance Integrated pail hook and hose threaded outlet for added convenience Service sink areas provide essential services to buildings each and every day. Chicago Faucets offers products that are up for the challenge with built-in safety features and comprehensive code compliance to help protect your potable water supply. 2 www.chicagofaucets.com

Choose The Right Faucet For Your Service Sink Protecting your potable water supply against contamination is too important to be left to inferior or inadequate plumbing equipment. Something as simple as a hose attached to a faucet and submerged in a bucket full of detergent can put your building s entire water system at risk. Choosing the right faucet for your service sink reduces the risk of contamination resulting from backflow. Determine if the faucet will be installed on a non-pressurized or a continuous pressure line. An example of a non-pressurized line is a hose attached to the end of a service sink faucet. It is a line without shut-offs downstream. The outlet of the faucet is never connected to another device or system that can produce back pressure. A continuous pressure line is where pressure is continuously applied to a backflow preventer for extended periods of time from a hot water space-heating boiler, an automatic dilution dispensing system, or a system that incorporates a shut-off downstream. Vacuum Breaker Spouts Help Reduce The Risk Of Backflow Atmospheric Vacuum Breaker Spout Our atmospheric vacuum breaker spout is designed for use on non-pressurized systems. When installed properly, it can provide excellent protection against backflow. The spout incorporates a vacuum breaker that is closed by the ambient air pressure when the water flow is off. It helps prevent backflow from a non-pressurized source like a hose submerged in a bucket of contaminated water. Model 445-VBRRCF with atmospheric vacuum breaker spout, Spill Resistant Vacuum Breaker Spout Our spill resistant vacuum breaker spout is designed for use on continuous pressure lines and is recommended for any application with system connections or shut-offs downstream. The spout incorporates a vacuum breaker with a spring-loaded poppet that helps prevent contaminated water from entering the water supply. The vacuum breaker must be installed vertically. Pressure must not exceed 150 psi. Model 445-PVBCP with continuous pressure vacuum breaker spout, When You Need Your Faucets Fast Products designated CFNow! ship within 3 days and are available for shipment within 24 hours of your order. We ve Been Right Here Since 1901 Our facilities in the heart of the United States, allow us to make America s #1 brand of commercial faucets. www.chicagofaucets.com 3

305-VBRCF 305-VBRCP Models 305-VBCP and 305-VBRCF Models 305-VBRCP and 305-VBRRCF Adjustable 7-5/8 8-3/8 Centers Adjustable 7-5/8 8-3/8 centers Model 445-VBRRCF Model 445-PVBCP Adjustable 3 8-3/8 Centers Available in rough chrome plated finish Quaturn compression operating cartridges 2-1/2 offset adjustable supply arms Spill resistant vacuum breaker spout, integral service stops and check valves Adjustable 3 8-3/8 centers Riser pipe brace Available in polished chrome plated finish Quaturn compression operating cartridges 2-1/2 offset adjustable supply arms Intended for continuous pressure systems 4 www.chicagofaucets.com

Model 540-LD897SCP Model 814-VBCP Adjustable 7-1/4 8-3/4 Centers Adjustable 3 13 centers 835-CP Models 835-CP and 835-RCF Model 886-CP Exposed with supplies from above 6 centers Quaturn compression operating cartridges Adjustable 3 8-3/8 centers Available in rough chrome plated finish Quaturn compression operating cartridges 2-1/2 offset adjustable supply arms www.chicagofaucets.com 5

897-RCF 897-CCP Models 897-CP and 897-RCF Models 897-CCP and 897-CRCF Adjustable 7-5/8 8-3/8 Centers and check valves Adjustable 7-5/8 8-3/8 centers Inlet supply arms with check valves 952-CP Model 911-ISCP Models 952-CP and 998-RCF Elevated atmospheric vacuum breaker 8 centers Slow compression operating cartridges Tear drop wall escutcheons Inside sill fitting 3/4 NPT female thread inlet Slow compression cartridge 2-1/4 tee handle, tapered square broach 6 www.chicagofaucets.com

Faucet Comparison Guide Use this comparison chart to help in your selection of the best Chicago Faucets janitorial service faucet for your project. Product Feature 305-VBRCF 305-VBRRCP 445-VBRRCF 445-PVBCP Spill resistant vacuum breaker (ASSE 1056) n Integral service stops n n n Integral check valves n n For use in pressurized systems n Atmospheric vacuum breaker (ASSE 1001) n n n Wall brace n n n Pail hook n n n n Quaturn compression operating cartridge n n n n 3/4 male hose thread outlet n n n n CFNow! n n Buy American Act compliant n n n n Product Feature 540-LD897SCP 814-VBCP 835-CP 886-CP Spill resistant vacuum breaker (ASSE 1056) Integral service stops n Integral check valves For use in pressurized systems Atmospheric vacuum breaker (ASSE 1001) n n n n Wall brace n n n Pail hook n n n Quaturn compression operating cartridge n n n n 3/4 male hose thread outlet n n n n CFNow! n n n n Buy American Act compliant n n n n Product Feature 897-CCP 897-RCF 911-ISCP 952-CP Spill resistant vacuum breaker (ASSE 1056) Integral service stops n n n Integral check valves n For use in pressurized systems Atmospheric vacuum breaker (ASSE 1001) n n n n Wall brace n n n Pail hook n n n Quaturn compression operating cartridge n n 3/4 male hose thread outlet n n n n CFNow! n n n n Buy American Act compliant n n www.chicagofaucets.com 7

U. G R E E N B U I L D. S I N G M C O U N C E M B I L E R We are a member of the U.S. Green Building Council and support the Leadership in Energy and Environmental Design (LEED) Green Building Rating System, to measure the efficiency and sustainability of buildings in the U.S. and Canada. If you are trying to achieve LEED Certification for your building, our low-flow outlets, metering cartridges, and sensoroperated faucets can contribute points in these areas: Water Efficiency Credit 2: Innovative Wastewater Technologies and Water Efficiency Credit 3: Water Use Reduction. We are proud to be a partner with WaterSense, sponsored by the EPA and designed to protect the future of our nation s water supply by promoting efficiency and enhancing the market for water efficient products, programs, and practices. We are a charter sponsor of the Alliance for Water Efficiency, a non-profit organization that is dedicated to the efficient and sustainable use of water. It brings together a diverse range of stakeholders to advocate water efficiency and conservation. Chicago Faucets, a member of the Geberit Group, is the leading brand of commercial faucets and fittings in the United States, offering a complete range of products for schools, laboratories, hospitals, office buildings, food service, airports, and sports facilities. Whatever your requirements may be, Chicago Faucets offers standard and made-to-order products that are designed to meet any commercial application. The Chicago Faucet Company 2100 South Clearwater Drive Des Plaines, IL 60018 Phone: 847/803-5000 Fax: 847/803-5454 Technical: 800/832-8783 www.chicagofaucets.com 2017 The Chicago Faucet Company. Product specifications subject to change without notice. CF2009 07/17