4SCU13 PRODUCT SPECIFICATIONS

Similar documents
4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14 SERIES

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

MAINLINE MLA14 AIR CONDITIONERS

FMU4X, FMC4X FMU4P, FMC4P

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

VARIABLE SPEED AIR CONDITIONERS

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

Evaporator (DX) Freon Applications 1 12 Tons MHF

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Uniflair LE TDAR-TUAR

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

MAINLINE MLP14**A HEAT PUMPS

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See for the current revision.

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

Ruud Achiever Series Heat Pump

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump

RPLA. Heat Pumps. Parts List 19-July-2011

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Ducted Reverse Cycle Air Conditioning of Distinction

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

Rheem Classic Series Heat Pump

This parts list is current as of the above revision date. See for the current revision.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

RPKA. Heat Pumps. Parts List 07-May-2014

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

Ruud Achiever Series Heat Pump

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

RPNK. Heat Pumps. Parts List 25-July-2011

Rheem Classic Series Two Stage Heat Pump

This parts list is current as of the above revision date. See for the current revision.

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

FA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Product Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

AIR COOLED SCREW WATER CHILLERS

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Part 1 General Information Part 2 Outdoor Units... 8

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

AE R1 February 2015

The CWE / HWE-R Series: Overview. Frame and cabinet covering

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Product Data. FB4CS, FB4CQ (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Type 3 - PSA Nitrogen Generation System

TECHNICAL SPECIFICATIONS

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

Commercial Standard and High-Efficiency Condensing Units

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

NLE11CNL V/60Hz 1~

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

Aquavar SOLO 2 Frequently Asked Questions

/ /

NLE10CN V/50Hz 1~

DLE5.7CN V/60Hz 1~

KKT Training Series: ECO Series, Preventative Maintenance

Refrigeration and Air Conditioning Technical leaflet

OPERATING INSTRUCTIONS

DLE6.5CN V/60Hz 1~

Capacity regulator (hot gas bypass)

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

TON MODELS 50 HERTZ STYLE D

System Pressure Manager Standard & System Pressure Manager Plus

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

DLE7.5CN V/50Hz 1~

the new Ve- / VSE Range

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

MODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010

KCS-Line. Air Cooled Condensers NEW CONTENTS PRODUCT DATA & INSTALLATION. Refrigerant: R404A, R507, R22

IMPORTANT SAFETY INSTRUCTIONS

200 PSI COMPRESSORS - MODEL NUMBERS

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Supersedes: RP1(495) Form RP1 (1102)

The X-11 Molding Chamber

Flow and check valves Logic valves series 551. Brochure

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Transcription:

4SCU PRODUCT SPECIFICATIONS PHASE SPLIT SYSTEM AIR CONDITIONER FORM NO. 4SCULC-00 (0/07) coil ifice shipped with outdo unit f optimum efficiency and capacity Charged f 5 ft. of line set Trade available components High pressure cutout kit Crank case heater DESIGN Designed f ambients up to 5 F ACCESSORIES Low ambient control Thermal expansion valve kits Sht cycle protection kit WARRANTIES year parts; 5 year compress COMPRESSOR High-efficiency scroll compress R40A refrigerant Grommet-mounted compress f quiet operation Internally protected against high temperature mot overload conditions CABINET Full metal louvered panel coil guard protection Controls located in cner post f easy installation and service Rounded cners f safety and attractive, clean appearance Baked polyester paint finish over galvanized steel f maximum durability External gauge pts f easy service COIL Enhanced aluminum fins and copper tubing f high efficiency and capacity Raised coil prevents debris from collecting in bottom of coil and causing loss of airflow COMPONENTS Full metal louvered panels remove with just two screws per panel f easy coil cleaning and service Filter drier installed f system protection Service valves positioned f quick installation and easy service Page

PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC MODEL NUMBER GUIDE 4 - R40A Split Condensing Unit - Nominal Louvered Commercial 4 SCU LC 6 T - A Min Revision Code Maj Revision Code VOLTAGE T - 08-0x/60hz/Ph F - 460v/60hz/Ph Model COOLING PERFORMANCE WITH EVAPORATOR COILS Model Evapat Coil AHRI Capacity Sensible Capacity Btuh Piston Expansion Series NOMINAL CAPACITY 6-6,000 Btuh 48-48,000 Btuh 60-60,000 Btuh 4SCULC6F E(U,C,M)P50C.00 0.80 4,800 6,00 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C.00 0.80 4,800 6,00 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C.00 0.80 4,800 6,00 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 ELECTRICAL AND PHYSICAL DATA Model Voltage/ Phase/ Hz Voltage Range Min. Circuit Amp. Max. Over current Compress Load Locked Rot Load Fan Mot HP Nom. RPM Refrig. Charge (oz.) 4SCULC6T 08-0//60 97-5 4. 0 0.4 7.0. /5 075 89 0 4SCULC48T 08-0//60 97-5 8.8 0.7 8..7 /4 85 0 Weight (lbs.) 4SCULC6T 4SCULC48F E(U,C,M)P50C.00 0.80 4,800 6,00 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A,B,C.00 0.80 4,800 6,00 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P4B,C.00 0.80 4,800 6,00 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C)P60D.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,H)P49C.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,H)P6C.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,H)P6D.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P48C.00 0.80 46,500 4,400 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 4SCULC60T 08-0//60 97-5. 5 5.6 0.0.7 /4 85 60 8 E(U,C)P60D.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 4SCULC6F 460//60 44-506 7.8 5 5.8 8.0 0.55 /5 075 89 0 4SCULC48F 460//60 44-506 8.8 5 6. 4.0.0 /4 85 0 4SCULC60F 460//60 44-506 0.7 5 7.8 5.0.0 /4 85 60 8 4SCULC48T E(U,C,H)P49C.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,H)P6C.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,H)P6D.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P48C.00 0.80 46,500 4,400 600 7/8 /8 7/8 /8 7/8 /8 NA A40 E(U,C,M)P50C.00 0.80 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 DIMENSIONS (IN.) AND SOUND RATINGS Model No. (T and F Models) A B C Sound Ratings dba 4SCULC6 4-/4 6-/4 9-/4 76 4SCULC48 9-/8 -/4 7-/4 78 4SCULC60F 4SCULC60T E(U,C,H)P49C.00.00 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 0.090 H40 E(U,C,H)P6C.00.00 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 0.090 H40 E(U,C,H)P6D.00.00 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 0.090 H40 E(U,C,H)P49C.00.00 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 0.090 H40 E(U,C,H)P6C.00.00 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 0.090 H40 E(U,C,H)P6D.00.00 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 0.090 H40 4SCULC60 9-/8 -/4 -/4 78 Page Page

PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC Model Model Evapat Coil Air Handler Variable Speed ARI Capacity BTUH Sensible Expansion Piston Model Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Expansion Piston E(U,C,M)P50C A95DFV090C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A 80GUH070AV.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFV090C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C 80GUH0CV0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFV0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C 80GUH0CV0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFV0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A A80DFE045A.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHE090C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80DFE090B6.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHE090C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80DFE0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHE0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80DFE0C0.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHE0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80DFV090B6.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95UHV045BS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80DFV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95UHV070BS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80DFV0C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV090CS 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A A80UHE045A*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV090CS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80UHE070B*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV090C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 4SCULC6F E(U,C,M,H)P6B A80UHE090B6*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHE090C0* 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHE090C0*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHE0C0* 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 4SCULC6F E(U,C,M,H)P6C A95UHV090C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV090C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV090C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV0C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHE0C0*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV0C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A A80UHV070A.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80UHV090B.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHV090C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A96DFMV070B.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHV090C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96DFMV090C6 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A96DFMV090C6.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHV0C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96DFMV090C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95DFE070B6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A96DFMV090C0.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFE090C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96DFMV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFE090C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A96DFMV0C0.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFE0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A96UHMV070B.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFE0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96UHMV090C 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95DFV045BS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 Page 4 Page 5

PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC Model Expansion Model Expansion Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Piston Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Piston E(U,C,M,H)P6C A96UHMV090C.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96UHMV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHV0C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 4SCULC6F E(U,C,M,H)P6C A96UHMV0C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B EFVBC.5.5 5,00 6,400 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C EFV6CC 4.0.5 5,400 6,600 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C LUF*****V0.5.5 5,400 6,600 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95DFE070B6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFE090C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFE090C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFE0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C LUF*****V0.5.5 5,00 6,400 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFE0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 ACBXCM-6.0 0.8 4,000 5,500 00 7/8 /8 7/8 /8 7/8 /8 NA NA E(U,C,M,H)P6B A95DFV045BS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A 80GUH070AV.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFV090C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C 80GUH0CV0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFV090C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C 80GUH0CV0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95DFV0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A A80DFE045A.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95DFV0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80DFE090B6.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHE090C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80DFE0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80DFE0C0.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80DFV090B6.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 4SCULC6T E(U,C,M,H)P6C A95UHE090C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHE0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHE0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80DFV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95UHV045BS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 4SCULC6T E(U,C,M,H)P6C A80DFV0C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A A80UHE045A*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80UHE070B*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A95UHV070BS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV090CS 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV090CS.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80UHE090B6*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV090C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHE090C0* 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV090C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHE090C0*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV090C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHE0C0* 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV090C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHE0C0*.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV0C6S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6A A80UHV070A.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV0C6S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A80UHV090B.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A95UHV0C0S 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHV090C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A95UHV0C0S.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A80UHV090C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6B A96DFMV070B.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 Page 6 Page 7

PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC Model Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Expansion Piston Model Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Expansion Piston E(U,C,M)P50C A96DFMV090C6 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C 80GUH0CV0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M,H)P6C A96DFMV090C6.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80DFE0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A96DFMV090C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80DFV0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M,H)P6C A96DFMV090C0.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C)P6D A80UHE5D0*.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A96DFMV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHV090C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M,H)P6C A96DFMV0C0.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A80UHV0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 4SCULC6T E(U,C,M,H)P6B A96UHMV070B.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96UHMV090C 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C,M,H)P6C A96UHMV090C.5.0 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96UHMV0C0 4.0.5 5,00 6,400 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 4SCULC48T E(U,C)P6D A80UHV5D0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A95DFE0C0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A95UHE0C0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C)P6D A95UHE5D0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M,H)P6C A96UHMV0C0.5.5 5,000 6,00 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C)P6D A95UHV5D0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M,H)P6B EFVBC.5.5 5,00 6,400 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 E(U,C,M)P50C A96UHMV0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C EFV6CC 4.0.5 5,400 6,600 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C)P6D A96UHMV5D0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C LUF*****V0.5.5 5,400 6,600 00 7/8 /8 7/8 /8 7/8 /8 0.07 A40 E(U,C)P6D EFV0DC 4.0.5 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M,H)P6C LUF*****V0.5.5 5,00 6,400 00 7/8 /8 /4 /8 7/8 /8 0.07 A40 ACBXCM-48.0.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 NA NA ACBXCM-6.0 0.8 4,000 5,500 00 7/8 /8 7/8 /8 7/8 /8 NA NA E(U,C,M)P50C 80GUH0CV0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A80DFE0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A80DFV0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 4SCULC60F ACBXCM-60.0.0 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 NA NA E(U,C)P6D A80UHE5D0*.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 4SCULC48F E(U,C,M)P50C A80UHV090C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A80UHV0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C)P6D A80UHV5D0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A95DFE0C0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A95UHE0C0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 4SCULC60T ACBXCM-60.0.0 58,000 4,00 800 7/8 /8 7/8 /8 /8 /8 NA NA E(U,C)P6D A95UHE5D0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C)P6D A95UHV5D0S.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C,M)P50C A96UHMV0C0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C)P6D A96UHMV5D0.5.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 E(U,C)P6D EFV0DC 4.0.5 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 0.08 A40 ACBXCM-48.0.0 47,000 4,800 600 7/8 /8 7/8 /8 7/8 /8 NA NA Page 8 Page 9

PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC COOLING PERFORMANCE EXTENDED RATINGS ACCESSORIES Model Model Temp DB/WB ºF Temp - DBºF 65 8 95 05 5 Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw KIT NUMBER DESCRIPTION USED WITH 40K58 Blower Off Delay Kit All 4SCULC s 4SCULC6 E(U,C,M,H)P6A,B,C 85/7 9,500.67.7 7,00.69.6 5,800.70.56 4,400.7.7,500.75.97 80/67 8,500.70.4 6,600.7. 4,800.7.5,400.75.70,500.78.94 75/6 7,500.7. 5,600.75.0,800.76.50,400.78.67 0,500.8.9 69J0 Compress Sound Covers All 4SCULC s 45F08 Compress Low Ambient Cut off All 4SCULC s 9G5 Freezestats (/8"tubing) All 4SCULC s 4SCULC48 E(U,C,M)P50C 85/7 54,800.66. 5,500.69.40 49,000.70.56 47,500.7.67 45,00.7.85 80/67 5,800.69.8 49,500.7.7 47,000.7.5 45,500.74.64 4,00.76.8 75/6 50,800.7.5 47,500.75.4 45,000.76.50 4,500.77.6 4,00.79.79 50A9 Freezestats (5/8 tubing) All 4SCULC s 47J7 Time off Control (A/C only) All 4SCULC s W6 Low Pressure Switch f loss of charge protection All 4SCULC s 4SCULC60 E(U,C,H)P49C 85/7 6,000.66.7 6,000.67.7 60,000.70.56 58,500.7.7 57,000.74.9 80/67 60,000.69.4 59,000.70.4 58,000.7.5 56,500.74.70 55,000.77.89 75/6 58,000.7. 57,000.7. 56,000.76.50 54,500.77.67 5,000.80.86 4M7 Low Ambient All 4SCULC s A40 Kit 4SCULC6, 48, & 60 H40 Kit 4SCULC60 NOTE: M coils are in both painted and embossed metal cabinets - check the coil specification f specifics. NOTE: H coils are available in embossed metal only. Page 0 Page

PHASE SPLIT SYSTEM AC 4SCULC All specifications and illustrations subject to change without notice and without incurring obligations. -800-448-587 Fm No. 4SCULC-00 (0/07) 07 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. Page