Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty
|
|
- Beatrix Simmons
- 5 years ago
- Views:
Transcription
1 Applications: Hazardous Duty Explosion Proof, Three Phase Class I Groups C & D, Class II Groups F & G, Rigid Base installed in hazardous environments as defined by the motor's explosion proof class and group rating. Consult the National Electrical Code and your local regulations for the proper selection of motors in hazardous locations. 1.0 Service Factor Automatic reset thermal protector (cannot be used on VFD) Meets temperature code T3B Explosion proof conduit box included, shipped loose Ball Bearings CSA Certified File No. LR47504 HP RPM VOLTS FRAME CAT. MODEL LIST MULT. NOM. F.L. APPROX. C FOOT NO. NO. PRICE SYMB. EFF. AMPS LBS. DIM. NOTES 1/ / G646 56T17E5308 $510 F / N G664 56T17E5314 $510 F N 1/ / G647 56T17E5309 $543 F / N G665 56T17E5315 $543 F N 1/ / G648 56T34G5303 $499 F / / G649 56T17G5312 $573 F / G666 56T17G5321 $573 F / / G660 56T34G5304 $547 F / / G661 56T17G5313 $605 F / G667 56T17G5322 $605 F / G662 56T34G5305 $581 F / / G663 56T17G5314 $611 F / G668 56T17G5323 $611 F Applications: Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty Class I Group D, Class II Groups F & G, C-Face Rigid Base For use on fans, blowers, pumps, compressors, machine tools, and other equipment installed in hazardous environments as defined by the motor's explosion proof class and group rating. Consult the National Electrical Code and your local regulations for the proper selection of motors in hazardous locations. 10:1 Variable torque, see Inverter Duty column for constant torque 1.15 Service Factor Normally closed thermostats (must be connected to control circuit) Meets temperature code T3B All cast iron construction External surface treated with epoxy paint Nameplated 60/50 hertz, 190/380 Volts, at next lower horsepower where footnoted (575 Volt excluded) Ball Bearings CSA Certified File No. LR21839 and LR47504 Two year warranty HP RPM VOLTS FRAME CAT. MODEL CT SPEED LIST MULT. NOM. F.L. APPROX. C FOOT NO. NO. RANGE PRICE SYMB. EFF. AMPS LBS. DIM. NOTES / TC C TTGN :1 $709 E / ,80 1 1/ / TC C TTGN :1 $750 E / , / TC C TTGN :1 $789 E / , / TC C TTGS :1 $917 E / TC C TTGS :1 $917 E N Totally Enclosed, Non-Ventilated 20 Rated 60/50 hertz, 190/380 or 380 volt 80 Rolled steel fan guard on 143T-145T Continued on next page. 83
2 Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty Class I Group D, Class II Groups F & G, C-Face Rigid Base HP RPM VOLTS FRAME OVER CAT. MODEL CT SPEED LIST MULT. NOM. F.L. APPROX. C FOOT LOAD NO. NO. RANGE PRICE SYMB. EFF. AMPS LBS. DIM. NOTES / TC TSTAT C TTGS :1 $999 E / TC TSTAT C TTGS :1 $999 E / / TC TSTAT C TTGS :1 $1,358 E / TC TSTAT C TTGS :1 $1,358 E / TC TSTAT C TTGS4028 2:1 $1,562 E / TC TSTAT C TTGS4049 2:1 $1,562 E Hazardous Duty Explosion Proof, Three Phase Class I Group D (Group C as noted), Class II Groups F & G, C-Face Applications: installed in hazardous environments as defined by the motor's explosion proof class and group rating. Consult the National Electrical Code and your local regulations for the proper selection of motors in hazardous locations. 56 Frame TC Frame Construction Rolled Steel Cast Iron "Blue Chip" Thermal Protection Auto Overload T-Stats Class/Group Class I, Groups C & D, Class I, Group D Class II, Groups F & G Class II, Groups F & G Temperature Code T3B T3B Conduit Box Shipped Loose Installed Service Factor UL File E12044 E12044 CSA File LR47504 LR47504 HP RPM VOLTS FRAME BRGS. OVER CAT. MODEL CT SPEED LIST MULT. NOM. F.L. APPROX. C FOOT LOAD NO. NO. RANGE PRICE SYMB. EFF. AMPS LBS. DIM. NOTES 1/ /460 56C BALL AUTO G827 56T17E $476 F / CD,N C BALL AUTO G842 56T17E $476 F CD,N 1/ /460 56C BALL AUTO G828 56T17E $503 F / CD,N C BALL AUTO G843 56T17E $503 F CD,N 1/ /460 56C BALL AUTO G829 56T17G $530 F / CD C BALL AUTO G844 56T17G $530 F CD 3/ /460 56C BALL AUTO G840 56T17G $559 F / CD C BALL AUTO G845 56T17G $559 F CD / TC BALL TSTAT C TTGN :1 $650 E / , /460 56C BALL AUTO G841 56T17G $566 F / CD C BALL AUTO G846 56T17G $566 F CD 1 1/ / TC BALL TSTAT C TTGN :1 $676 E / , / TC BALL TSTAT C TTGN :1 $688 E / , / TC BALL TSTAT C TTGN7022 2:1 $734 E / , / TC BALL TSTAT C TTGN :1 $725 E / , / TC BALL TSTAT C TTGS :1 $807 E / / TC BALL TSTAT C TTGS7068 2:1 $863 E / / TC BALL TSTAT C TTGS7313 2:1 $1,013 E / / TC BALL TSTAT C TTGS7072 2:1 $937 E / / / TC BALL TSTAT C TTGS7304 2:1 $1,313 E / / TC BALL TSTAT C TTGS7067 2:1 $1,282 E / / TC BALL TSTAT C TTGS7024 2:1 $1,470 E / / TC BALL TSTAT C TTGS7065 2:1 $1,468 E / / TC BALL TSTAT C TTGP7021 2:1 $1,922 E / / TC BALL TSTAT C TTGP $1,892 E / / TC BALL TSTAT C TTGP7012 2:1 $2,308 E / / TC BALL TSTAT C TTGP7060 2:1 $2,366 E / d Will become build-up item when current stock is gone CD Suitable for Group C N Totally Enclosed, Non-Ventilated Service Factor 20 Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
3 Applications: Hazardous Duty Explosion Proof, Three Phase Blue Chip XRI NEMA Premium Severe Duty Class I Group C & D, Class II Groups F & G, Rigid Base installed in hazardous environments as defined by the motor s explosion proof class and group rating. Consult the National Electrical Code and your local regulations for the proper selection of motors in hazardous conditions. footnoted Meets NEMA Premium efficiencies 10:1 Variable torque, see Inverter Duty column for constant torque MAX GUARD Class F insulation 1.15 Service Factor on sinewave or 1.0 Service Factor on IBGT power Normally closed thermostats (must be connected to control circuit) Meets temperature code T3B All cast iron construction Shaft slinger Internal and external surfaces treated with epoxy paint Extended grease tubes Nameplated 60/50 Hz, 190/380 Volts, at next lower HP where See modification section for addition of C-Face Kits (254T-445T) Contact Marathon Electric for F2 mounting Ball Bearings, except where noted CSA Certified File Nos. LR21839 and LR47504 Three year warranty Contact Marathon Electric for lower HP ratings XRI ENERGY EFFICIENT MOTORS IP54 HP RPM VOLTS FRAME CAT. MODEL CT SPEED LIST MULT. NOM. F.L. APPROX. C FOOT NO. NO. RANGE PRICE SYMB. EFF. AMPS LBS. DIM. NOTES 7 1/ / T E TTGN :1 $2,101 E / / T E TTGN :1 $2,534 E / / T E TTGN :1 $2,054 E / / T E TTGN :1 $2,042 E / / T E TTGN :1 $3,520 E / / T E :1 $2,588 E / / T E TTGN :1 $2,417 E / / T E :1 $4,105 E / / TS E TSTGN :1 $3,341 E / / T E TTGN :1 $3,075 E / / T E :1 $5,184 E / / TS E TSTGN :1 $3,601 E / / T E TTGN :1 $3,565 E / / T E TTGS :1 $6,068 E / / TS E TSTGS :1 $4,847 E / / T E TTGS :1@ $4,745 E / / T E TTGS :1 $7,522 E / NP / TS E TSTGS :1@ $6,146 E / , / T E TTGS :1@ $5,778 E / / T E TTGS :1@ $8,545 E / / TS E TSTGS :1@ $8,928 E / / T E TTGS :1 $8,395 E / / T E TTGS :1 $10,671 E / / TS E TSTGS :1@ $10,346 E / / T E TTGS :1@ $9,859 E / :1, / T E TTGS :1@ $12,426 E / Requires larger fan NP Does not meet NEMA Premium efficiency level 2:1 Suitable for 2:1 Constant Torque operation; consult R164 Rework table for fan change pricing to upgrade to 10:1 CT that meet or exceed U.S. EPAct and/or NRCan Canadian standards. 20 Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower 87 10:1 Constant torque available as build-up, refer to marketing for price and availability Continued on next page. 85
4 Hazardous Duty Explosion Proof, Three Phase Blue Chip XRI NEMA Premium Severe Duty Class I Groups C & D, Class II Groups F & G, Rigid Base HP RPM VOLTS FRAME CAT. MODEL CT SPEED LIST MULT. NOM. F.L. APPROX. C FOOT NO. NO. RANGE PRICE SYMB. EFF. AMPS LBS. DIM. NOTES / TS E TSTGS :1 $13,996 E / / T E TTGS :1 $12,701 E / / T E TTGS :1@ $17,067 E / , TS E :1@ $19,320 E , T E TTGS :1@ $16,403 E :1, T E TTGS :1@ $20,412 E TS E :1 $21,586 E T E TTGS :1 $19,391 E T E :1@ $22,212 E RB TS E :1@ $26,340 E T E TTGN :1@ $21,983 E T E :1 $28,632 E RB, TS E :1@ $31,840 E T E :1 $26,969 E RB, T E :1 $30,074 E RB, T E :1@ $33,682 E Requires larger fan R164 Rework Table: Multiplier Symbol S4 R-164 Rework for 10:1 Constant Torque: Fan Change* & Re-Nameplate FRAME LIST PRICE $ $ $ $250 * Fan change to allow 10:1 constant torque may reduce motor full load efficiency below EPAct levels. Operation of motor on non-sinusoidal wave form exempts motor from EPAct mandated efficiency levels. RB Roller Bearing on shaft end for belted loads only 2:1 Suitable for 2:1 Constant Torque operation; consult R164 Rework table for fan change pricing to upgrade to 10:1 CT 20 Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower 87 10:1 Constant torque available as build-up, refer to marketing for price and availability 86
5 Hazardous Duty Explosion Proof, Three Phase Blue Chip Severe Duty Class I Group D (Group C as noted), Rigid Base Applications: installed in hazardous environments as defined by the motor's explosion proof class and group rating. Consult the National Electrical Code and your local regulations for the proper selection of motors in hazardous locations. 10:1 Variable torque, 2:1 Constant torque 1.15 Service Factor Class F insulation Meets temperature code T2A All Cast iron construction Shaft slinger External surface treated with epoxy paint Nameplated 60/50 Hz, 190/380 Volts, at next lower HP See modification section for addition of C-Face kits (254T-445T) Ball bearings, except where noted CSA Certified File Nos. LR21839 and LR47504 Two year warranty IP54 HP RPM VOLTS FRAME GROUP CAT. MODEL LIST MULT. NOM. F.L. APPROX. C FOOT C NO. NO. PRICE SYMB. EFF. AMPS LBS. DIM. NOTES / T N U TTGN1026 $538 E / , / T N U TTGN1076 $632 E / ,80 1 1/ / T N U TTGN1001 $563 E / , / T N U TTGN1026 $566 E / , / T N U TTGS1076 $683 E / / T N U TTGN1001 $628 E / , / T N U TTGN1027 $605 E / , / T N U TTGS1076 $791 E / / T N U TTGS1001 $708 E / / T N U TTGS1026 $709 E / / T N U TTGS1076 $1,016 E / / T N U TTGS1001 $891 E / / T N U TTGS1026 $789 E / / T N U TTGS1076 $1,347 E / / / T N U TTGS1001 $1,141 E / / T N U TTGS1026 $1,083 E / / T Y U TTGN1076 $1,800 E / / T N U TTGS1001 $1,313 E / / T N U TTGS1026 $1,286 E / / T Y U TTGN1076 $2,204 E / / T N U TTGP1001 $1,758 E / / T Y U TTGN1026 $1,687 E / / T N U TTGN1076 $3,032 E / / T Y U TTGN1001 $2,254 E / / T Y U TTGN1026 $2,049 E / / T N U TTGN1076 $3,576 E / / TS N U TSTGP1001 $2,866 E / / T Y U TTGP1026 $2,561 E / / T Y U TTGP1076 $4,472 E / Motor will NOT accept C-Face kits 80 Rolled steel fan guard on 143T-145T Continued on next page. 87
6 Hazardous Duty Explosion Proof, Three Phase Blue Chip Severe Duty Class I Group D (Group C as noted), Rigid Base HP RPM VOLTS FRAME GROUP CAT. MODEL LIST MULT. NOM. F.L. APPROX. C FOOT C NO. NO. PRICE SYMB. EFF. AMPS LBS. DIM. NOTES / TS N U TSTGP1001 $3,108 E / / T Y U TTGP1026 $3,007 E / / T Y U TTGS1076 $5,295 E / / TS Y U TSTGP1001 $4,157 E / / T Y U TTGP1026 $3,971 E / / T Y U TTGS1086 $6,984 E / / TS Y U TSTGP1001 $5,478 E / / T Y U TTGP1026 $4,911 E / / T Y U TTGS1086 $7,982 E / / TS Y U TSTGS1001 $7,959 E / / T Y U TTGS1036 $7,292 E / / T Y U TTGS1086 $9,415 E / / TS Y U TSTGS1001 $9,280 E / / T Y U TTGS1036 $9,049 E / / T Y U TTGS1086 $11,037 E / / TS Y U TSTGS1001 $12,513 E / / T Y U TTGS1036 $11,044 E / / T Y U TTGS11077 $15,492 E / TS Y U TSTGS1001 $17,420 E T Y U TTGS1036 $14,358 E T Y U TTGN1086 $18,440 E TS Y U TSTGN1001 $20,490 E T Y U TTGN1036 $17,076 E T Y U TTGN1087 $20,115 E RB TS Y U $25,130 E T Y U TTGN1038 $19,661 E RB T Y U TTGS1088 $24,295 E RB TS Y H TSTGS8003 $27,720 E T Y H TTGS8038 $22,807 E RB T Y H $25,507 E RB T Y H $28,000 E RB RB Roller Bearing on shaft end for belted load only 88
Hazardous Duty Division 1 Explosion Proof Class I Only, Groups C (as noted), D
lass I Only, Groups (as noted), D Blue hip, EPAct Efficiency, Three Phase 10:1 Variable torque, 2:1 onstant torque 1.15 Service Factor lass F insulation Meets temperature code T2A All ast iron construction
More informationMotors for the Long Run! SB338. marathonelectric.com
Motors for the Long Run! SB338 A WORLD OF ENERGY SOLUTIONS marathonelectric.com 800.616.7077 Easy to do business with 24/7/365!!! ME business: Marathon Electric s new and improved ecommerce site, ME business,
More informationEngineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24. Frame: 71D
Product Features Catalog No: L085/O043/098066.00 Model: CI42D34FT7C Engineering Data RPM: 3000 HP: Serv. Factor: 1,0 KW:,37 Form Factor: 1,00 Amps: 20 KW2: Form Factor 2: FLA2: Volts: 24 Frame: 71D Max
More informationGeneral Purpose Three Phase Open Dripproof (ODP) NEMA Premium Efficient IE3
General Purpose Three Phase Open Dripproof (ODP) Premium Efficient IE3 GENERAL APPLICATIONS: For pumps, fans, compressors, material handling, and other general purpose applications where contaminants are
More informationINSTALLATION AND MAINTENANCE MANUAL
INSTALL.06 INSTALLATION AND MAINTENANCE MANUAL WORLDWIDE ELECTRIC THREE-PHASE MOTORS WorldWide Electric Corporation Phone: 1-800-808-2131 Ext. 3 Fax: 1-800-711-1616fffffgff Website: www.worldwideelectric.net
More informationW01 Rolled Steel Fractional Horsepower Motor
Motors Automation Energy Transmission & Distribution Coatings Fractional Horsepower Motor Technical Catalogue NEMA Market The new generation of WEG general purpose steel motors. The motors of the line
More informationDESIGN ENVELOPE 6800 G 1 DUTY PUMP
DESIGN ENVELOPE 68 G 1 DUTY PUMP AND 1 STANDBY, DOMESTIC WATER BOOSTER WIT STANDBY N122s N192s SUBMITTAL File No: 1.615 Date: june 27, 217 Supersedes: new Date: new Job: Representative: Engineer: Contractor:
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationCOMPRESSOR MANUAL. (888)
COMPRESSOR MANUAL www.ultimadentalsystems.com (888) 900-8584 Table of Contents Introduction..Page 2 Quick Compressor Start Guide....Page 3-5 Compressor Pump Diagram....Page 6 Compressor Frame Diagram....Page
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table
More informationOHIO GEAR REDUCERS DESIGN FEATURES
REDUCERS Cast Iron NEMA C Flange with machined fits for precision alignment for motor and bearings. Seal Guard on quill-input styles protects input seals from damage during motor installation. Oversized
More information100C Air Compressor Kit
10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is
More informationVERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts
Peerless Pump Company Indianapolis, IN 46207-7026 VERTICAL TURBINE PUMPS Right Angle Gears SECTION 110 Page 1 January 2, 2007 Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts A
More informationLENNOX SLP98UHV DIAGNOSTIC CODES
Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
More information200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More information420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO
420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationAll technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI
PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Table of Contents Section - 1 Table of Contents... 1-1 Glycol
More information250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
More information250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
More informationT Y P E V S A B M S E W A G E P U M P
Pe r fo r m a n ce C h a r t s 11 1 D R Y P I T S B U L L E T I N 2 3 9 8 7 6 5 4 3 2 1 12 11 1 / 4 1 1 / 2 9 3 / 4 9 5% 3 HP 5 HP 7 1/2 HP 1 HP 76% 5% C u r v e P a g e V S A B M - 4 1 1 5 R P M M O D
More informationCP3R Quick Start Manual
RUN MON PRM PU EXT NET RUN D700 3 200V RUN MON PRM PU EXT NET RUN D700 3 200V CP3R Quick Start Manual for Constant Pressure Applications This CP3R Drive has been factory pre-programmed for your specific
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More information42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)
42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor
More informationTurbo Blowers. Combustion Excellence Since Features. Benefits
Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any
More informationCPN1 Quick Start Manual
RUN MON PRM PU EXT NET RUN RUN MON PRM PU EXT NET RUN CPN1 Quick Start Manual for Constant Pressure Applications This CPN1 Drive has been factory pre-programmed for your specific pressure control application.
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationDiaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860
PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI
More informationDESCRIPTION / REMARKS E40972 ROTATION (2).250 FLAG TYPE Q.C. TERMS. WITH INSUL. GRIP ON BROWN LEADS. LEADS SKINNED.750±.062
Dimensional Drawing MODEL REF CUSTOMER HP VOLTS AMPS HZ RPM ROTATION CUSTOMER PN DESCRIPTION / REMARKS K55HXRHM2147 E40972 DAYTON 1/6 208230 1.3 60 1075 C.CW. LEAD END REV BALL BEARING E40972 #16 GREEN
More informationMODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More information200 PSI FAST-FILL AIR SOURCE KIT
200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationMODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE
MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock
More informationYEOMANS SUBMERSIBLE SOLIDS-HANDLING PUMPS STANDARD SILICON CARBIDE MECHANICAL SEALS FEATURES & BENEFITS
YEOMANS SUBMERSIBLE SOLIDS-HANDLING PUMPS STANDARD SILICON CARBIDE MECHANICAL SEALS FEATURES & BENEFITS Yeomans submersible motors are furnished with a tandem mechanical seal arrangement consisting of
More information4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS
PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy
More informationOPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks
OPERATION, INSTALLATION, & MAINTENANCE MANUAL for Aircon Flex-air AN Airlocks Aircon Corporation P.O. Box 80446 2873 Chelsea Avenue Memphis, TN 38108-0446 Telephone: (901) 452-0230 FAX: (901) 452-0750
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationModel 531A AURORA. 530 Series SINGLE STAGE SUMP PUMPS NSB
Model 531A AURORA 530 Series SINGLE STAGE SUMP PUMPS NSB WWW.AURORAPUMP.COM AURORA 530 Series Single Stage Sump Pumps NSB Capacities to 1200 GPM Heads to 180 Feet Temperatures to 180 F Introduction The
More information444C DUAL PERFORMANCE VALUE PACK
(Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL
More informationSafety Shutoff Valves MVD/6 Series MVDLE/6 Series
Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved
More information400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO
400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand
More informationMODEL NUMBER: P PORTABLE COMPRESSOR
MODEL NUMBER: 44043-440P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.
More informationO.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA
HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation
More information200 PSI HIGH-FLOW AIR SOURCE KIT
200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationMODEL NUMBER: P PORTABLE COMPRESSOR
MODEL NUMBER: 30033-300P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.
More information1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.
CONTENTS 1. PARTS 3. 2. INTRODUCTION 4. 3. ELECTRICAL NOTES 5. 4. INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. 8. ELECTRICAL CONNECTIONS 10/11. 9. SPECIFICATIONS
More informationMODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR
MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and
More informationPortable Oil Lube Air Compressors
Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationMaster Control Systems, Inc. Variable Speed Fire Pump Controllers
Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2013 UL/FM Listed and Approved for fire protections 1 Why Variable Speed? Huge Sprinkler System and Standpipe Cost Savings
More informationIndustrial TE-5.5-MD-CK. Applications. Features. Construction
Industrial TE-5.5-MD-CK Applications Circulation of highly corrosive acids, alkalis, solvents, brine, plating solutions, sterile solutions, and other highly corrosive chemicals and solutions that are compatible
More informationTHE DISECTION of the SUBMERSIBLE MOTOR and PUMP. Deepwell Submersibles
THE DISECTION of the SUBMERSIBLE MOTOR and PUMP THE DISECTION of the SUBMERSIBLE MOTOR and PUMP Presented by: Ken Adams Project Engineer - Submersibles History: Twenty Six Years as Flowserve Design Engineer,
More informationFMU4X, FMC4X FMU4P, FMC4P
ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal
More informationCertificate of Compliance
FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed
More informationBell & Gossett ESP-Systemwize Pump Selections
Bell & Gossett ESP-Systemwize Pump Selections Monday Morning Minutes by Norm Hall, May 14, 2018 Monday,May 14, 2018 ESP-Systemwize is a powerful tool provided to the industry by Bell & Gossett. As an engineer
More information400C & 450C DUAL PERFORMANCE VALUE PACKS
(Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before
More informationJORDAIR/BAUER Service Manual
JORDAIR/BAUER Service Manual Breathing Air Compressor Maintenance Log Doc. ServiceManual Page - 1 SAFETY RELEASE-2016 The following document is prepared to ensure safety of operators and service technicians.
More informationG92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
More informationGRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz
GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical
More informationAquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated
AquaDDM Direct-Drive Mixer Often Imitated Never Duplicated AquaDDM Mixer Proven mixing efficiency The AquaDDM Mixer is designed to provide maximum mixing efficiency. For those applications where mixing
More informationSECTION TESTING ADJUSTING AND BALANCING FOR HVAC
SECTION 23 05 93 - TESTING ADJUSTING AND [Note to PSC: Existing System Coordination When connecting to an existing system, it is the PSC s Responsibility to examine existing documents, field verify existing
More informationD. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER
. ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces
More informationVARIOspeed 3R User Manual
VARIOspeed 3R User Manual This VARIOspeed 3R control panel is designed to provide constant pressure control for your pumping system. Should you need to make minor adjustments, please consult the parameter
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationInoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.
Inoxair Repair Manual Edition: 12/2010 Content 1) Serial number 2) Technical data 3) Functional principle 4) Problem analysis 5) Removal 6) Repairs 7) Circuit diagram and cable-connection-plan 8) Pneumatic
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationU.S. TSUBAKI BS/DIN ROLLER CHAIN
TSUBAKI BS/DIN ROLLER CHAIN BS/DIN Roller Chain These chains are manufactured to International Standards Organization metric dimensions (ISO 606), British Standard (BS 228), and DIN 8187. They are available
More informationSingle-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA
62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More information450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing
More information450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS
More informationWARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS
WELDING POSITIONER MODEL NO: WP-250 00317OG091207 WARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS Warnings and Safeguards for Welding and Cutting Operations IMPORTANT - Protect yourself and others! Remember
More informationAquavar SOLO 2 Frequently Asked Questions
Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the
More informationTHE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED
THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary
More informationPage - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302
CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More information2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A
2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A PROJECT ADDRESS TESTING AUTHORITY TELEPHONE Checked by/date Enforcement Agency Use GENERAL INFORMATION OF BLDG. PERMIT PERMIT # BLDG. CONDITIONED FLOOR
More informationSizing Enclosures for SCR Power Controllers
INTRODUCTION Application Note 1002 Sizing Enclosures for SCR Power Controllers Author - George A. Sites, AMETEK HDR Power Systems Most applications for SCR Power Controllers require some type of enclosure.
More informationAMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS
AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationBudget Range Operators Handbook
Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk
More informationWARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS
WELDING POSITIONER MODEL NO: WP-500 00336OG09207 WARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS Warnings and Safeguards for Welding and Cutting Operations IMPORTANT - Protect yourself and others! Remember
More informationE.2 Series. High efficiency circulator. Technical overview
E.2 Series High efficiency Technical File No:.165 Date: june 05, 2017 Supersedes:.165 Date: october 08, 2015 contents Motor data 4 Technical data 4 Materials of construction 4 Dimensions and weights 5
More informationAdvanced Pump Control for Irrigation Applications
Advanced Pump Control for Irrigation Applications Paul Nistler VFD Applications Engineer And Julian Atchia Director of Research and Development SJE Rhombus 22650 County Hwy 6 Detroit Lakes MN 56502 Executive
More informationCOMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet
For Door Heights To 8 (environmental separation) COMMERCIAL LOW PROFILE 8 Data Sheet STANDARD CONSTRUCTION 8 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White
More informationIf you want to offer a more professional look to your
Model RT366 Model RT364C Low profile island trim 11" (279) griddle (optional) Porcelain coated cast iron top grates Dual brass burners 36" GAS RANGETOPS Model RT364G Stainless steel exterior finish Large
More informationLighting Contactors. 4.1 UL Rated AC Contactors
Electrically Held Lighting Contactors.1 Product Description....................................... Application Description.................................... Standards and Certifications................................
More informationRéf GB /d ALTERNATORS LSA Pole - Three phase. Electrical and mechanical data
Réf. 264 GB - 2.33/d - 9. 3 2 1 1 ALTERNATORS LSA 42.2-4 Pole - Three phase Electrical and mechanical data TYPICAL DATA ALTERNATORS Hz - 1 r.p.m. Insulation class H Excitation system Shunt A R E P Winding
More informationA17W49_MASEM_F_EN MANUAL
AW9_MASEM_F_EN MANUAL CONTENTS Identification. Manufacturer. Product name. Year of manufacture. Area of use. Declaration of conformity Technical specification. Design. Function. Technical data. Electrical
More informationPumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
More information(1) Warranty Certificate 01. (2) About the use of Traction Machine 03. (3) General Instructions 03. EMC Directive 03. Copy Right Low 03.
01 (1) Warranty Certificate 01. (2) About the use of Traction Machine 03. (3) General Instructions 03. EMC Directive 03. Copy Right Low 03. Sign - Symbol - Interpretation & Meaning 04. (4) Technical Drawing
More informationAutoDrill s OUTSTANDING FEATURES
PRODUCTION DRILLING & TAPPING SOLUTIONS Reduce Your Costs and Increase Your Production The Affordable, Powerful, Compact Solution AutoDrill s OUTSTANDING FEATURES Self Feeding with Air or Oil Thrust Capacity
More informationOperating and Maintenance Instructions 3BA Regenerative Blowers
Operating and Maintenance Instructions 3BA Regenerative Blowers INSTALLATION & OPERATING MANUAL 3BA REGENERATIVE BLOWERS Table of Contents Section: Page Number: 1. Pump Ranges 3 Table 1: 3 Phase, Single
More informationMODEL 300 BACKLAPPER OWNERS MANUAL
MODEL 300 BACKLAPPER OWNERS MANUAL Neary Technologies 1173 Benson Street River Falls, WI 54022 1 Manual No. 30019 (7-07) SAFETY INSTRUCTIONS Safety Awareness Symbols are inserted into this manual to alert
More informationField Certification Certificate of Compliance
1 Field Certification Certificate of Compliance Certificate: 2460594 Master Contract: 244849 Project: 2460594 Date Issued: 2011-12-23 Issued to: Sirio Sistemi Elettronici SpA Via Fleming 16 59100 Prato
More information6000SLX HYDRAULIC CRAWLER CRANE
HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE Contents Specifications 3-4 Symbols 4 Outline Winch Assingment 5 Dimensions & Main Specifications : Liftcrane 6 Dimensions & Main Specifications : Luffing