Lighting Contactors. 4.1 UL Rated AC Contactors

Size: px
Start display at page:

Download "Lighting Contactors. 4.1 UL Rated AC Contactors"

Transcription

1 Electrically Held Lighting Contactors.1 Product Description Application Description Standards and Certifications Additional Reference V10-T- V10-T- V10-T- V10-T- Mechanically Held Lighting Contactor Catalog Number Selection Enclosures Cover Control Operation Accessories Wiring Diagrams V10-T-3 V10-T-3 V10-T- V10-T-8 V10-T-1 V10-T-13 Type 1 Electrically Held Lighting Contactors Type 1 Non-Combination Lighting Contactors Volume 10 Enclosed Control CA E November 01 V10-T-1

2 .1 Lighting Contactors Contents Description Catalog Number Selection Enclosures Cover Control Product Selection Operation Non-Combination Contactors Combination Contactors Accessories Wiring Diagrams Page V10-T-3 V10-T-3 V10-T- V10-T-5 V10-T-8 V10-T-10 V10-T-1 V10-T-13 Product Description Eaton s lighting contactors are designed to provide a safe, convenient means for local or remote switching of tungsten (incandescent filament) or ballast (fluorescent and mercury arc) lamp loads. They are also suitable for other loads such as low pressure and high pressure sodium lamp loads and other non-motor (resistive) loads. They are not recommended for most sign flashing loads. These lighting contactors are designed to withstand the large initial inrush currents of tungsten lamp loads without contact welding. They are fully rated and do not require derating. Application Description Loads: Ballast Lamps Fluorescent, mercury vapor, metal halide sodium vapor, quartz 600V maximum. Filament Lamps Incandescent, infrared, heating 80V maximum, line to line; 77V maximum line to neutral. Resistance Heating Radiant and convection heating, furnaces and ovens. Standards and Certifications Note: See Tab 17 for additional information on Standards and Certifications that apply to all Enclosed Control products. UL Listed cul Listed ABS Type Approved OSHPD Certified (OSP ) Additional Reference Accessories V10-T-1 and Tab 15 Cover Control V10-T- Dimensions Tab 1 Accessories and Modifications Tab 15 Technical Data and Specifications Tab 17 V10-T- Volume 10 Enclosed Control CA E November 01

3 .1 Catalog Number Selection Enclosed Lighting Contactors Design L = CN35 or A0 lighting contactor C = C30CN lighting contactor Class Page 03 = Non-combination electrically held lighting contactor V10-T-5, V10-T-6 0 = Non-combination ly held/magnetically latched lighting contactor 1 = Combination electrically held lighting contactor fusible disconnect 13 = Combination magnetically latched lighting contactor fusible disconnect 1 = Combination electrically held lighting contactor thermal magnetic circuit breaker 15 = Combination magnetically latched lighting contactor thermal magnetic circuit breaker A = 10A B = 0A C = 30A Enclosures Lighting contactors are available open or mounted in Type 1, 3R,, X, 1 or 7/9 enclosures. Type 1 is for indoor, general purpose for personal protection. Knock-outs are provided in the top and bottom for conduit entry. Type 3R is for outdoor applications and rated for rain, sleet and external ice buildup. Type 3R enclosures have knockouts in the bottom and provisions for a hub in the top. 1 C30CN available in 30A only. For normally closed poles see Tab 15. Ampere Size 1 D = 60A E = 100A F = 00A V10-T-5, V10-T-8 V10-T-10 V10-T-10 V10-T-11 V10-T-11 G = 300A H = 00A J = 600A Enclosure Types 1 = Type 1 General purpose = Type 3R Rainproof 3 = Type Watertight (painted) = Type X Watertight (30-Grade stainless steel) 6 = Type 7/9 Explosion proof 8 = Type 1 Dust-tight 9 = Type X Watertight (316-Grade stainless steel) EC L 1 D 1 A 3 E - X Type and X are for mounting indoor or outdoor and provide protection from splashing water, hosedirected water and windblown dust. Watertight conduit hubs are provided in the top and bottom of Type X enclosures. The standard Type X enclosures are made of 30-Grade stainless steel, providing corrosion protection. 316-Grade stainless steel construction is available as an upgrade option. A = None B = 30A/50V R C = 30A/600V R D = 60A/50V R E = 30A/600V R F = 100A/50V R G = 100A/600V R H = 00A/50V R A = None D = 0A E = 30A Type 1 enclosures are for indoor mounting and protect from dripping liquids, falling dirt and dust. No knockouts or hubs are provided with Type 1 enclosures. Modification Codes (See V10-T- and Tab 15) Disconnect Fuse Clip Ratings J = 00A/600V R K = 00A/50V R L = 00A/600V R M = 600A/50V R N = 600A/600V R P = 800A/600V R T = By description Thermal-Magnetic Breaker Ratings F = 60A G = 100A H = 00A Number of Poles 1,, 3,, 5, 6, 7, 8, 9 = Poles required A = 10 poles B = 1 poles C = 0 poles Combination Devices = Three-pole only A = 10/60 110/50 B = 0/60 0/50 C = 80/60 0/50 D = 600/60 550/50 E = 08/60 G = 550/50 H = 77/60 J = 08 0/60 Coil Voltage K = 0/50 L = 380/50 M = 15/50 P = 1 Vdc Q = Vdc R = 8 Vdc S = 15 Vdc J = 300A K = 00A L = 600A T = /60 U = /50 V = 3/50 W = 8/60 X = 10 10/60 Y = 8/50 Z = By description M = 800A T = By description Type 1, 3R, and 1 enclosures are painted with a polyester urethane powder coat paint meeting UL requirements and the color is ANSI 61 gray. Type 1 enclosures have knockouts for cover controls. All the other types have holes plugged, ready for cover controls. Type 7/9 is also available for explosion proof applications. Please contact the factory for additional details. Volume 10 Enclosed Control CA E November 01 V10-T-3

4 .1 Lighting Contactors Cover Control Cover Mounted Pilot Devices Description For Use with Lighting Contactor 1 For use with non-combination units (box sizes 1 ). Add code letter from table below to catalog number for voltage in place of _. Factory Installed Cover Control Type 1, 3R, X and 1 Type 7/9 Type 1 1 Modification Code Suffix Modification Code Suffix 3 For use with Type 1 combination units as well. Selector switch. 5 With three-position selector switch, Mod C0 (two-wire control relay) must be used with magnetically latched contactor (ECL0, ECL13, ECL15). Field Installation Kits Catalog Number Type 3R, X, 1 Combination and Non-Combination 3 Catalog Number ON/OFF pushbuttons Electrical P8 P8 C00GK18 C00T three-wire C30CN; CN35; A0 P8P3 P8P3 C00GK19_ With red RUN/GREEN off lights P8P3P5 P8P3P5 C00GK1A_ ON/OFF Pushbuttons Mechanical P8 P8 C00GK C00T01 three-wire C30CN P8P3 P8P3 C00GK8_ With red RUN/GREEN off lights P8P3P5 P8P3P5 C00GK9_ ON/OFF pushbuttons P8 P8 C00GK5 C00T1 two-wire C30CN; P8P3 P8P3 C00GK5_ With red RUN/GREEN off lights CN35; A0 P8P3P5 P8P3P5 C00GK55_ Start/stop pushbuttons Mechanical P7 P7 C00GK7 C00T00 three-wire C30CN P7P3 P7P3 C00GK7_ With red RUN/GREEN off lights P7P3P5 P7P3P5 C00GK75_ Start/stop pushbuttons P7 P7 C00GK6 C00T13 two-wire C30CN P7P3 P7P3 C00GK6_ With red RUN/GREEN off lights P7P3P5 P7P3P5 C00GK65_ HAND/OFF/AUTO cover control S3 S3 5 C00GK3 C00T1 two-wire C30CN; S3P3 S3P3 5 C00GK3_ With red RUN/GREEN off lights CN35; A0 S3P3P5 S3P3P5 5 C00GK35_ Red RUN pilot light All P3 P3 C00GK_ C00T9_ Green OFF pilot light P5 P5 C00GK1_ C00T10_ Red RUN/green OFF pilot light P3P5 P3P5 C00GK6_ C00T11_ Rating Code Letter Rating Code Letter Rating Code Letter V 60 Hz T 0V 60 Hz B 80V 60 Hz C 10V 60 Hz A 77V 60 Hz H 600V 60 Hz D 08V 60 Hz E 380V 60 Hz L V10-T- Volume 10 Enclosed Control CA E November 01

5 .1 Product Selection Two-Wire and Three-Wire Control Wiring Options Two-Wire Control Standard Class ECC03 Non-Combination Electrically Held Lighting Contactor Two or Three-Wire Control Component Number Type 1 Type 3R Type X Type 7/9 Type 1 Contactor (Open) of Poles Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Continuous Amps 30 ECC03C1_A ECC03C_A ECC03C_A ECC03C6_A ECC03C8_A C30CNE0_0 3 ECC03C1_3A ECC03C_3A ECC03C_3A ECC03C6_3A ECC03C8_3A C30CNE30_0 ECC03C1_A ECC03C_A ECC03C_A ECC03C6_A ECC03C8_A C30CNE0_0 5 ECC03C1_5A ECC03C_5A ECC03C_5A ECC03C6_5A ECC03C8_5A C30CNE50_0 6 ECC03C1_6A ECC03C_6A ECC03C_6A ECC03C6_6A ECC03C8_6A C30CNE60_0 7 ECC03C1_7A ECC03C_7A ECC03C_7A ECC03C6_7A ECC03C8_7A C30CNE70_0 8 ECC03C1_8A ECC03C_8A ECC03C_8A ECC03C6_8A ECC03C8_8A C30CNE80_0 9 ECC03C1_9A ECC03C_9A ECC03C_9A ECC03C6_9A ECC03C8_9A C30CNE90_0 10 ECC03C1_AA ECC03C_AA ECC03C_AA ECC03C6_AA ECC03C8_AA C30CNE100_0 1 ECC03C1_BA ECC03C_BA ECC03C_BA ECC03C6_BA ECC03C8_BA C30CNE10_0 Class ECC0 Non-Combination Mechanically Held Lighting Contactor Two-Wire Control 3 Component Number Type 1 Type 3R Type X Type 7/9 Type 1 Contactor (Open) of Poles Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Continuous Amps 30 ECC0C1_A ECC0C_A ECC0C_A ECC0C6_A ECC0C8_A C30CNM0_ 3 ECC0C1_3A ECC0C_3A ECC0C_3A ECC0C6_3A ECC0C8_3A C30CNM30_ ECC0C1_A ECC0C_A ECC0C_A ECC0C6_A ECC0C8_A C30CNM0_ 5 ECC0C1_5A ECC0C_5A ECC0C_5A ECC0C6_5A ECC0C8_5A C30CNM50_ 6 ECC0C1_6A ECC0C_6A ECC0C_6A ECC0C6_6A ECC0C8_6A C30CNM60_ 7 ECC0C1_7A ECC0C_7A ECC0C_7A ECC0C6_7A ECC0C8_7A C30CNM70_ 8 ECC0C1_8A ECC0C_8A ECC0C_8A ECC0C6_8A ECC0C8_8A C30CNM80_ 9 ECC0C1_9A ECC0C_9A ECC0C_9A ECC0C6_9A ECC0C8_9A C30CNM90_ 10 ECC0C1_AA ECC0C_AA ECC0C_AA ECC0C6_AA ECC0C8_AA C30CNM100_ 1 ECC0C1_BA ECC0C_BA ECC0C_BA ECC0C6_BA ECC0C8_BA C30CNM10_ 1 For first open position (coil voltage), use the table below. The catalog numbers listed in the Type X column are for Type X 30-Grade stainless steel, as indicated by the seventh digit. Example: ECC03CAA. To order Type X 316-Grade stainless steel, change that digit to 9. To order Type painted steel, change that digit to 3. To order non-metallic, change that digit to 5. For details on these alternate enclosures, see Tab 13. Suffix Coil Voltage Suffix Coil Voltage Suffix Coil Voltage A 10/60 or 110/50 D 600/60 or 550/50 T /60 B 0/60 or 0/50 E 08/60 V 8/60 or /50 C 80/60 or 0/50 H 77/60 or 0/50 X 37/60 3 Add C18 modification code for three-wire control. To get the C30CN lighting contactor with normally closed power poles, see Tab 15, for modification codes. Volume 10 Enclosed Control CA E November 01 V10-T-5

CUSTOM ENCLOSURE CUTOUTS

CUSTOM ENCLOSURE CUTOUTS www.factorymation.com/enclosures ENCLOSURES 147 WWW.FACTORYMATION.COM/ENCLO- CUSTOM ENCLOSURE CUTOUTS We ll cut the holes to your specifications so the enclosure arrives... READY FOR YOUR ASSEMBLY! Enclosure

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

STANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK

STANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK STANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK Industry Standards UL 50, Type 1 Nema Type 1 UL File E235575 X BUTT HINGES H 1/4 TURN LATCH 1-3/8" KNOCKOUT ON ALL SIDES W PANEL (ORDER SEPARATELY) STIFFENER DETAIL

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER . ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces

More information

Sizing Enclosures for SCR Power Controllers

Sizing Enclosures for SCR Power Controllers INTRODUCTION Application Note 1002 Sizing Enclosures for SCR Power Controllers Author - George A. Sites, AMETEK HDR Power Systems Most applications for SCR Power Controllers require some type of enclosure.

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association General Requirements of the NEC Advanced Course Building Officials and Inspectors Educational Association General Requirements -NEC Course Outcome Explain general requirements found in Article 110 of the

More information

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical

More information

Pushbuttons, Indicating Light, and Rotary Switch Stations Series 4975

Pushbuttons, Indicating Light, and Rotary Switch Stations Series 4975 Series 4975 Series 4975 Pushbutton Stations are designed for shipboard control applications requiring heavy duty watertight master switches. Stations are available with one, two or three elements equipped

More information

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS 36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER TFE-Lined Varea-Meter PVC-Tube Varea-Meter USFilter s Wallace & Tiernan Products offers a choice of two straight-through rotameters for metering difficult fluids and gases. The TFE-lined Varea-Meter is

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

G92 Series BASOTROL Automatic Pilot Gas Valve

G92 Series BASOTROL Automatic Pilot Gas Valve Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These

More information

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA 62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

TotalPac X Single interlock Preaction system Electric release

TotalPac X Single interlock Preaction system Electric release DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Safety switch renewal parts

Safety switch renewal parts Renewal Parts RP00801001E Supersedes July 2002 Safety switch renewal parts Contents Description Page Heavy-duty switch....2 Line shield....3 Operating mechanism....3 Operating handle....3 Fusible switching

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

PRICE LIST Effective From January LV SWITCHGEAR. Be Switch. The Real Switchgear 230 V. SwitchTM INDUSTRIAL PIONEER VALUE CREATOR

PRICE LIST Effective From January LV SWITCHGEAR. Be Switch. The Real Switchgear 230 V. SwitchTM INDUSTRIAL PIONEER VALUE CREATOR PRICE LIST Effective From January - 0 LV SWITCHGEAR SwitchTM Be 0 V INDUSTRIAL PIONEER VALUE CREATOR TM BeC BeC BeC Be S w i t c h BeC - BeC AC POLE POWER CONTACTOR 0 AC Duty Ampere BeC - 00 / 00 AMP.

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without

More information

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical

More information

G95 Series BASOTROL Single Operator Valve

G95 Series BASOTROL Single Operator Valve Product Bulletin Issue Date January 5, 2009 G95 Series BASOTROL Single Operator Valve The G95 Series BASOTROL valves are single operator, automatic valves available with a pressure regulator. For use in

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

MaxSB - Low Voltage Switchboard

MaxSB - Low Voltage Switchboard BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1 MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A,

More information

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming. SIROCCO is a family of floodlight, surface washer and area lighting. Three (3) types of light distribution, asymmetric, bi-symmetric, and road optic. Available in 2 sizes with a range of mounting accessories

More information

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel The Yacht Group - 4545 Ponce de Leon Blvd. Coral Gables FL 33146 Tel. 305.667.5811 - Fax. 305.663.5551

More information

XCE: Explosionproof Control Enclosures

XCE: Explosionproof Control Enclosures XCE SERIES XCE: Explosionproof Control Enclosures FEATURES 64 standard sizes available Pre-drilled for hinges (hinges optional) Pre-drilled for sub-panel (sub-panel optional) One-piece, NEMA 4 water-tight

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

ATMI Applications Techniques Modernes Industrielles

ATMI Applications Techniques Modernes Industrielles ATMI Applications Techniques Modernes Industrielles Z.A. de l observatoire - 2, avenue des Bosquets - 78180 Montigny-le-bretonneux - France Phone: +33 (0)1 61 37 35 60 - Fax: +33 (0)1 61 37 35 69 - info@atmi.fr

More information

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-6149 FAX www.norlake.com Kold Locker Walk-ins Standard Model Coolers

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No. FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right

More information

Pushbuttons and Indicating Lights

Pushbuttons and Indicating Lights Pushbuttons and Indicating Lights Pushbuttons Indicating Lights Emergency Stops Selector Switches.5 Product Overview.............................................. 2 Product Selection Guide.........................................

More information

MAGNETIC FLOAT SENSOR

MAGNETIC FLOAT SENSOR TS02-0143 I N S T R U C T I O N M A N U A L F O R MAGNETIC FLOAT SENSOR MODEL:FR Revision 2015-04-17 Read and understand this manual for safely usage. This manual describes the product of standard specification.

More information

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 40A00-1 HAI 15A Relay Switch (referred to as HAI UPB Wall Switch, in this document), and

More information

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve

More information

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

J21K Series DIFFERENTIAL PRESSURE SWITCH. features DIFFERENTIAL PRESSURE SWITCH J21K Series features Sealed Metal Bellows Sensors Welded 316 Stainless Steel Sensors Gasketed Die-Cast Aluminum Enclosure with Epoxy Coating Single Switch Output Adjustable

More information

In Ground Buried Uplights

In Ground Buried Uplights In Ground Buried Uplights BIANCHI LIGHTING SERVICES SUTTON CLOSE, EASTCOTE Enrico Bianchi Guidance notes for the specification and application of in ground buried uplights. MIDDLESEX HA5 2JX +44 (0)794

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL MOYNO Section: ACCESSORIES Page: 1 of 8 Date: May 1, 1998 SERVICE MANUAL FLUID DETECTION CONTROL GENERAL The Moyno Fluid Detection Control prevents unnecessary loss of production time or repair costs to

More information

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch) HAI UPB High Power Wall Switch Dimmer and HAI Auxiliary Switch Installation and Operating Instructions For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer)

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12 PSG 901 Pressure Switch for Gas elektrogas.com EE141-07/12 PSG 901 Pressure Switch for Gas (EN1854) Contents Description... 2 Features... 2 Functioning and application... 3 Technical specifications...

More information

3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL

3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL ORDER #: S/N: (Required for Warranty) 3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL Thank you for purchasing this AirScape whole house fan. Your fan has been designed to provide your home with natural,

More information

Flow Measurement Equipment Armored Purge Meters

Flow Measurement Equipment Armored Purge Meters Flow Measurement Equipment Armored Purge Meters Features & Key Benefits Accurate Gas Metering A snubber on the float causes readings to steady out quickly, gives true readings down to atmospheric pressures.

More information

Power Mod. Lug Kits, Custom Options, Elbows, & Spacers. Revised 06/01/13. Lug Kits, Custom Options, Elbows, & Spacers

Power Mod. Lug Kits, Custom Options, Elbows, & Spacers. Revised 06/01/13. Lug Kits, Custom Options, Elbows, & Spacers Lug Kits, Custom Options, Elbows, & Spacers 06/01/13 Lug Kits, Custom Options, Elbows, & Spacers Siemens offers a wide range of accessories and custom options to help product fit your application. Eliminate

More information

EASY AND SAFE WIRING DEVICES COMPLIANT WITH SAFETY STANDARDS. Get detailed information on many digital or printed supports or contact our sales team

EASY AND SAFE WIRING DEVICES COMPLIANT WITH SAFETY STANDARDS. Get detailed information on many digital or printed supports or contact our sales team BELANKO TM Belanko TM the ideal choice Fitting switches is probably only one of the many tasks that you have to undertake. By making sure that installation is safe and easy, you are left with more time

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof Hazardous Location Equipment - Canada Equipment listed in this category for Hazardous Locations is also suitable for installations in areas that are non-hazardous locations and, unless referenced in the

More information

Arran LED Floodlight Luminaire

Arran LED Floodlight Luminaire Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Product Bulletin Issue Date November 16, 2012 GM-7000 Series CE Approved Gas Control Valve The GM-7000 Series multi-function gas control valve works in conjunction with an electronic sequence control unit

More information

Environmental Protection of HMI Components

Environmental Protection of HMI Components EAO Your Expert Partner for Human Machine Interfaces White Paper Environmental Protection of HMI Components Author: Damian Semple, EAO Group Electromechanical devices, including switches, keypads, keyboards,

More information

LED LED Street Lamps. Industrial / Commercial LED "Corn" Lamps. 360 Beam Angle. Color 30=3000k 40=4000k 50=5000k 60=6000k.

LED LED Street Lamps. Industrial / Commercial LED Corn Lamps. 360 Beam Angle. Color 30=3000k 40=4000k 50=5000k 60=6000k. 2016 LED CORN LAMP Industrial / Commercial LED "Corn" Lamps o 360 Beam Angle High Lumen Omni-Directional 360 LED DLC & UL Listed, Rated / Damp Location Replaces HID, CFL and Incandescent Emits no UV light

More information

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus Hazardous Location Equipment - United States Equipment listed in this category for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations and, unless

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD WELL COMPLETION & PROTECTION MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD www..com WELL COMPLETION & PROTECTION TABLE OF CONTENTS TABLE OF CONTENTS (FLUSHMOUNTS)... 2-5 MONITORING

More information

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Raising the bar Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Philips Advance Optanium high-efficiency electronic ballasts are

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

(Certification N:o VTT 08 ATEX 066 or IECEx VTT ) (Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and

More information

VA Amps (24/115) A B C 230V 460V 24V 115V. Features: Designed for high in-rush applications High-grade silicon steel laminations

VA Amps (24/115) A B C 230V 460V 24V 115V. Features: Designed for high in-rush applications High-grade silicon steel laminations 212 CONTROL TRANSFORMERS Universal Input/ 205 MORE OPTIONS ONLINE Universal Input/ Group J Primary: 208/230/460; Secondary: 24/115 Standard Control Transformers *Shown with optional primary side fuse block

More information

CCT-7320/ROC-2313 Reverse Osmosis Controller

CCT-7320/ROC-2313 Reverse Osmosis Controller CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation

More information

Miniature controls. Contactors. Overload relays. Starters. Control relays

Miniature controls. Contactors. Overload relays. Starters. Control relays Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power

More information

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15 PRCEDURES FR RUTINE TESTING F CAPACITR BANKS Consultant : MEP Contractor: Project: PREPARED BY: DRMAN SMITH SWITCHGEAR - DUBAI NAME: REVIEWED BY CNSULTANT : NAME: SIGNATURE: SIGNATURE: Page 1 of 15 Table

More information

ComEx Actuating elements

ComEx Actuating elements ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

MAINLINE MLA14 AIR CONDITIONERS

MAINLINE MLA14 AIR CONDITIONERS FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured

More information

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 35A00-1 HAI 600W Dimmer Switch, 35A00-3 HAI 600W Non-Dimming Switch (collectively referred to

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information