PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES

Similar documents
J21K Series DIFFERENTIAL PRESSURE SWITCH. features

PRESSURE, VACUUM AND TEMPERATURE

Pressure, Vacuum, Differential Pressure

EXPLOSION-PROOF PRESSURE, VACUUM,

EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES

RoHS. 100 Series. 100 Series. Pressure, Vacuum, Differential Pressure. features. Certified for use in SIL2 functional safety systems.

EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE and TEMPERATURE SWITCHES

55 Series. 55 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES. Single or Dual 15 A Switch Output. Panel or Surface Mount

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, TEMPERATURE

Pressure, Vacuum, Differential Pressure

Pressure, Vacuum, Differential Pressure

800 Series. 800 Series INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES

120 Series Explosion-Proof Pressure and Differential Pressure Switches

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Part I - Installation

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

PRESSURE, VACUUM AND TEMPERATURE

10 Series PRESSURE SWITCH. features

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

Part I - Installation

Pressure, Vacuum & differential pressure

W Series. W Series HIGH PURITY PRESSURE SWITCHES FOR CLEAN GAS APPLICATIONS FEATURES

EXPLOSION - PROOF PRESSURE TRANSMITTER

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

PRESSURE SWITCH. features

9700 Transmitter Submersible hydrostatic level transmitter

Data Sheet. P-Series Explosion Proof Pressure Switches

Pressure and Vacuum Switches for Process Applications

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Electro-Pneumatic Converter YT-940 SERIES

CSA Sample Draw Aspirator Adapter Operator s Manual

780S Ultra High Purity Series

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Installation and Operation Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

CANADA SENSORS TECHNOLOGY INC.

Instruction Manual for Intrinsically Safe - Reed Switches

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Pressure switch Model PS01

How to specify a product. Process Sensors and Mechanical Instruments

I/P Transducer Positioner Module

SITRANS P measuring instruments for pressure

RK-IR Sample Draw Aspirator Adapter Operator s Manual

North American Pressure Switches

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Model 4000 Pressure Controller

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Pressure measurement. Pressure gauges

RCD - Ultra-Rugged Differential Pressure Flowmeter

High-performance submersible pressure transmitter For level measurement Model LH-10

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Installation, Operation and Maintenance Manual for Back Pressure Regulator

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Pressure Measurement Single-range transmitters for general applications

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

PRESSURE SWITCHES Bulletin 8757

The "BETA AIR RELAY"

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

Explosion proof pressure switch Model: P953 series

Buying more than 11 gauges? Call Lesman for additional discounts.

Pressure Switches Application Guideline

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

[Instruments for vacuum measurement, checking and adjustment] 3

INSTALLATION & MAINTENANCE INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Ultra High Purity Model 780S

Pressure & Temperature Switches

6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Pressure Switch for gas and air GGAO-A4

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Monitoring device NTS 30

Pressure switch for gas and air

DPC-30 DPC-100. Reference Manual

Pressure Switch for gas and air

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Gas Pressure Switch for DMV safety shutoff valves

features Fixed range or field-adjustable 4-20 ma, 1-5 or 0-10 VDC output 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Pressure switch and Thermostat CAS

Pressure Switch for gas and air

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

features 4-20 ma, HART 7 communication protocol 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure

Transcription:

117 S er i es 117 Se r i e s PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES features Epoxy Coated Type 4X Enclosure and Stainless Steel Component Parts Hermetically Sealed Snap Switch, SPDT or DPDT Output Terminal Block Wiring Tamper-Resistant Set Point Lock Adjustable Ranges: Pressure: 30 Hg Vac to 3500 psi (-1 to 241,3 bar) wc Ranges: 300 wc vacuum to 250 wc pressure (-746, 7 to 622,3 mbar) Differential Pressure: 0.8 wcd to 500 psid (2,0 mbar to 34,5 bar) Temperature: -120 to 640 F (-84.4 to 337.8 C) LEADERS IN SAFETY, ALARM & SHUTDOWN 1 1 7 - B - 0 5

117 Series overview Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications. The rugged, one piece enclosure features a slanted cover for wiring accessibility to the enclosed terminal block that is wired to either a SPDT or DPDT hermetically sealed microswitch. All welded, stainless steel pressure connections and sensors provide superior corrosion resistance NACE compliant and fire-safe protection within the harshest environments. The 117 Series is an ideal choice for the most demanding applications; typically steel and aluminum mills, chemical and petrochemical plants, pulp and paper mills, wastewater treatment plants, midstream and downstream oil & gas, and pharmaceutical plants. features Approved for Division 2, Zone 2 hazardous locations Optional ATEX or GOST intrinsic safety compliance for Zone 0 Hermetically sealed snap switch, SPDT or DPDT output Welded stainless steel diaphragms meet NACE MR-0175 standard Optional sensor material for corrosive media Ultra-low vacuum and pressure ranges Polished stainless steel flush mount sensors E117 bulb and capillary temperature switch shown with cover removed. Terminal block with SPDT switch output. 2 w w w. u e o n l i n e. c o m 1 1 7 - B - 0 5

specifications Storage temperature Ambient Temperature limits Set point repeatability Shock Vibration Enclosure Enclosure classification Switch output Electrical rating Weight Electrical connection -65 to 160 F (-54 to 71 C) -40 to 160 F (-40 to 71 C); except models 520-525, 540-548, 700-706: 0 to 160 F (-18 to 71 C); set point typically shifts less than 1% of range for a 50 F (28 C) ambient temperature change Temperature models: ± 1% of adjustable range Pressure models 171-174, 218, 358-376, 520-535, 540-543 and 700-706: ± 1% of adjustable range; models 183-194, 544-548, 483-494, 565-567: ± 1.5% of adjustable range Internal set point lock on all pressure models Set point repeats after 15 G, 10 millisecond duration Set point repeats after 2.5 G, 5-500 Hz Die cast aluminum, epoxy powder coated, gasketed; captive cover screws; anodized aluminum nameplate Enclosure Type 4X One SPDT hermetically sealed snap action switch; switch may be wired normally open or normally closed ; DPDT (option 1190/1195) 11 A 125/250 VAC resistive; 5 A @ 28 VDC; 1 A @ 48 VDC; 1/2 A @ 125 VDC; switch contacts gold flashed 1.5-6.5 lbs. Varies with model 1/2 NPT (female); two 7/8 diameter knockouts Pressure connection Models 218, 358-376, 700-706: 1/4 NPT (female); models 171-194, 483-494, 520-535: 1/2 NPT (female); models 565-567: 1.5 flush mount connection (mates with Tri-Clamp fitting systems), models 540-548: 1/8 NPT (female) Temperature assembly Bulb and capillary: 6 feet; 304 stainless steel Immersion stem: nickel-plated brass (standard); optional 316L stainless steel Fill Temperature deadband Reference scale Non-toxic oil filled Typically 4% of range under laboratory conditions (70 F ambient circulating bath at rate of 1/2 F per minute change) Pressure: High-Low reference scale Temperature: reference dial 1 1 7 - B - 0 5 w w w. u e o n l i n e. c o m 3

117 Series Approvals UE declarations and third-party issued Agency certifications are available for download at www.ueonline.com/prod_approval. UNITED STATES AND CANADA UL Listed, cul Certified Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III Enclosure Type 4X Pressure: UL 508 & 1604; CSA C22.2 No. 14 & 213 - File # E40857 Temperature: UL 508 & 1604; CSA C22.2 No. 24 & 213 - File # E43374 Canadian Registration Number (CRN): Refer to www.ueonline. com/certifications for list of approved models EUROPEAN UNION ATEX Directive 94/9/EC II 1 G Ex ia IIC T6 Ga (OPTIONAL code M405) Tamb = -50C to +60C UL International DEMKO A/S (N.B.# 0539) Certificate # DEMKO 11 ATEX 1105261X Rev. 0 EN 60079-0:2009, 60079-11:2007, 60079-26:2007 Low Voltage Directive (LVD) (2006/95/EC) UEC Compliant to LVD Products rated lower than 50 VAC and 75 VDC are outside the scope of the LVD The Low Voltage Directive does not apply to products for use in hazardous locations RUSSIA Gosgortechnadzor Permit (OPTIONAL code M406) 0ExiaIICT6 Tamb = -50C to +60C NANIO CCVE Certification Center Certificate # RRS 00-22739 GOST R 51330.0, 51330.1, 51330.10 & 51330.14 pressure model chart Pressure Equipment Directive (PED) (97/23/EC) UEC Compliant to PED Products rated lower than 7.5 psi are outside the scope of the PED Model Adjustable Set Point Range Deadband *Over Range Pressure **Proof Pressure Low end of range on fall; High end of range on rise Type H117 wc mbar wc mbar psi bar psi bar Buna N diaphragm and O-ring with epoxy coated aluminum 1/2 NPT (female) pressure connection; large 0.72 orifice for clean-out purposes (Other wetted materials available - see page 9) 520 300 Vac to 0-746,7 to 0 0.8 to 32 2,0 to 79,6 200 13,8 400 27,6 521 10 Vac to 10-24,9 to 24,9 0.4 to 2.4 1,0 to 6,0 200 13,8 400 27,6 522 50 Vac to 50-124,5 to 124,5 0.4 to 12 1,0 to 29,9 200 13,8 400 27,6 523 0.5 to 5 1,2 to 12,4 0.4 to 1.2 1,0 to 3,0 200 13,8 400 27,6 524 2.5 to 50 6,2 to 124,5 0.4 to 3.2 1,0 to 8,0 200 13,8 400 27,6 525 10 to 250 24,9 to 622,3 0.4 to 24 1,0 to 59,7 200 13,8 400 27,6 Welded 316L stainless steel diaphragm and 1/2 NPT (female) pressure connection, large 0.72 orifice for clean-out purposes 530 300 Vac to 0-746,7 to 0 0.8 to 60 2,0 to 149,3 50 3,4 100 6,9 531 10 Vac to 10-24,9 to 24,9 0.4 to 2.4 1,0 to 6,0 50 3,4 100 6,9 532 50 Vac to 50-124,5 to 124,5 0.4 to 12 1,0 to 29,9 50 3,4 100 6,9 533 0.5 to 5 1,2 to 12,4 0.4 to 1.2 1,0 to 3,0 50 3,4 100 6,9 534 2.5 to 50 6,2 to 124,5 0.4 to 3.2 1,0 to 8,0 50 3,4 100 6,9 535 10 to 250 24,9 to 622,3 0.4 to 40 1,0 to 99,6 50 3,4 100 6,9 *Over Range Pressure: The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability. ** Proof Pressure: The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. The unit may require calibration (e.g. start-up, testing). 4 w w w. u e o n l i n e. c o m 1 1 7 - B - 0 5

Model Adjustable Set Point Range Deadband *Over Range **Proof Pressure Low end of range on fall; Pressure High end of range on rise Type H117 psi bar (unless noted) psi bar (unless noted) psi bar psi bar 1.5 flush mount, welded 316L stainless steel diaphragm and pressure connection. Mates with Tri-Clamp fitting systems (not UE supplied) 565 5 to 30 0,3 to 2,1 3 to 15 0,2 to 1,0 1000 68,9 1500 103,4 566 10 to 100 0,7 to 6,9 3 to 36 0,2 to 2,5 1000 68,9 1500 103,4 567 15 to 300 1,0 to 20,7 9 to 66 0,6 to 4,6 1000 68,9 1500 103,4 Welded 316L stainless steel diaphragm and 1/2 NPT (female) pressure connection, large 0.72 orifice for clean-out purposes; NACE MR- 0175 compliant 171 1 to 20 68,9 mbar to 1,4 bar 0.1 to 3 6,9 mbar to 0,2 500 34,5 1000 68,9 172 2 to 50 0,1 to 3,4 0.1 to 5 6,9 mbar to 0,3 500 34,5 1000 68,9 173 4 to 100 0,3 to 6,9 0.1 to 10 6,9 mbar to 0,7 500 34,5 1000 68,9 174 8 to 200 0,6 to 13,8 0.1 to 15 6,9 mbar to 1,0 500 34,5 1000 68,9 316L stainless steel diaphragm (optional Hastelloy C or Monel ); Viton GLT O-ring (optional Kalrez, Ethylene Propylene, or Aflas ); 316 stainless steel 1/2 NPT (female) pressure connection (optional Hastelloy C, or Monel ), large 0.72 orifice for clean-out purposes. Models 188 and 189 have a 316L stainless steel 1/2 NPT (female) pressure connection; NACE MR-0175 compliant 183 1 to 20 0,1 to 1,4 0.3 to 5 20,7 mbar to 0,3 500 34,5 1000 68,9 184 2 to 50 0,1 to 3,4 0.3 to 10 20,7 mbar to 0,4 500 34,5 1000 68,9 185 4 to 100 0,3 to 6,9 0.5 to 16 34,5 mbar to 0,7 500 34,5 1000 68,9 186 8 to 200 0,6 to 13,8 0.5 to 21.5 34,5 mbar to 1,2 500 34,5 1000 68,9 188 50 to 1000 3,4 to 68,9 30 to 300 2,1 to 20,7 2000 137,9 7000 482,6 189 250 to 3500 17,2 to 241,3 50 to 500 3,4 to 34,5 4000 275,8 7000 482,6 316L stainless steel diaphragm (optional Hastelloy C, or Monel ; Viton GLT O-ring (optional Kalrez, Ethylene Propylene or Aflas ); 316 stainless steel 1/2 NPT (female) pressure connection (optional Hastelloy C, or Monel ), 0.06 orifice to dampen pulsations. Models 488 and 489 have a 316L stainless steel 1/2 NPT (female) pressure connection; NACE MR-0175 compliant 483 1 to 20 0,1 to 1,4 0.3 to 5 20,7 mbar to 0,3 500 34,5 1000 68,9 484 2 to 50 0,1 to 3,4 0.3 to 10 20,7 mbar to 0,4 500 34,5 1000 68,9 485 4 to 100 0,3 to 6,9 0.5 to 16 34,5 mbar to 0,7 500 34,5 1000 68,9 486 8 to 200 0,6 to 13,8 0.5 to 21.5 34,5 mbar to 1,2 500 34,5 1000 68,9 488 50 to 1000 3,4 to 68,9 30 to 300 2,1 to 20,7 2000 137,9 7000 482,6 489 250 to 3500 17,2 to 241,3 50 to 500 3,4 to 34,5 4000 275,8 7000 482,6 Application Note: The use of metallic diaphragms where higher pressure shock or heavy cycling is expected should be avoided. Models 171-174 should not be used where system or start-up vacuum pressure might exceed 26 Hg Vac (-0,9 bar). Use of optional diaphragm materials for models 483-489 may increase deadband. Hastelloy is a registered trademark of Haynes International, Inc. Monel is a registered trademark of the Special Metals Corporation Aflas is a registered trademark of Asahi Glass Viton and Kalrez are registered trademarks of E.I DuPont de Nemours and Company Tri-Clamp is a registered trademark of Alfa Laval. 1 1 7 - B - 0 5 w w w. u e o n l i n e. c o m 5

117 Series pressure model chart Model Adjustable Set Point Range Deadband *Over Range **Proof Low end of range on fall; Pressure Pressure High end of range on rise Type H117 psi (unless noted) bar psi (unless noted) bar (unless noted) psi bar psi bar Phosphor bronze bellows with nickel-plated brass 1/4 NPT (female) pressure connection; 303 stainless steel spring exposed to media 218 30 Hg Vac to 0-1 to 0 2 to 5 Hg 0,07 to 0,17 3 0,2 30 2,1 Welded 316L stainless steel bellows and 1/4 NPT (female) pressure connection 358 15 to 200 1,0 to 13,8 6 to 20 0,4 to 1,4 200 13,8 800 55,2 361 20 to 300 1,4 to 20,7 8 to 22 0,6 to 1,5 300 20,7 800 55,2 376 25 to 500 1,7 to 34,5 10 to 28 0,7 to 1,9 500 34,5 800 55,2 Lower 75% Top 25% Lower 75% range span range span range span psi (unless noted) psi bar Welded 316 stainless steel diaphragm and 1/2 NPT (female) pressure connection, large 0.72 orifice for clean-out purposes; NACE MR- 0175 compliant (except model 194) 190 5 to 30 0,3 to 2,1 3 to 8 10 max 0,2 to 0,6 1500 103,4 2500 172,4 191 10 to 100 0,7 to 6,9 3 to 30 45 max 0,2 to 2,1 1500 103,4 2500 172,4 192 15 to 300 1,0 to 20,7 10 to 40 60 max 0,7 to 2,8 1500 103,4 2500 172,4 193 20 to 500 1,4 to 34,5 15 to 45 75 max 1,0 to 3,1 1500 103,4 2500 172,4 194 80 to 1700 5,5 to 117,2 5 to 120 200 max 0,3 to 8,3 2000 137,9 2500 172,4 Welded 316 stainless steel diaphragm and 1/2 NPT (female) pressure connection, 0.06 orifice to dampen pulsations; NACE MR-0175 compliant (except model 494) 490 5 to 30 0,3 to 2,1 3 to 8 10 max 0,2 to 0,6 1500 103,4 2500 172,4 491 10 to 100 0,7 to 6,9 3 to 30 45 max 0,2 to 2,1 1500 103,4 2500 172,4 492 15 to 300 1,0 to 20,7 10 to 40 60 max 0,7 to 2,8 1500 103,4 2500 172,4 493 20 to 500 1,4 to 34,5 15 to 45 75 max 1,0 to 3,1 1500 103,4 2500 172,4 494 80 to 1700 5,5 to 117,2 5 to 120 200 max 0,3 to 8,3 2000 137,9 2500 172,4 Deadband Notes: Models 190-194, 490-494 are expressed as the lower 75% and top 25% of the range span because of the operating characteristics of the welded stainless steel diaphragm sensor and hermetically sealed switch. *Over Range Pressure: The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability. ** Proof Pressure: The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. The unit may require calibration (e.g. start-up, testing). ***Working Pressure Range: The pressure range within which two opposing sensors can be safely operated and still maintain set point adjustability provided the difference in pressure between them does not exceed the designated adjustable range. 6 w w w. u e o n l i n e. c o m 1 1 7 - B - 0 5

Model Adjustable Set Point Range Deadband *Over Range Pressure **Proof Pressure Low end of range on fall; High end of range on rise Type H117 psi bar psi bar psi bar psi bar Buna N diaphragm and O-ring with 316 stainless steel 1/4 NPT (female) pressure connection; option M540 Viton diaphragm and O-ring available 700 3 to 20 0,2 to 1,4 1,0 to 4 0,1 to 0,3 500 34,5 1000 68,9 702 3 to 100 0,2 to 6,9 2 to 12 0,1 to 0,8 500 34,5 1000 68,9 704 15 to 500 1,0 to 34,5 15 to 30 1,0 to 2,1 1500 103,4 2500 172,4 706 100 to 1700 6,9 to 117,2 20 to 110 1,4 to 7,6 2000 137,9 2500 172,4 Differential Pressure Model Chart Model Adjustable Set Point Range Deadband ***Working **Proof Low end of range on fall; Pressure Pressure High end of range on rise Type H117K psid (unless noted) bar (unless noted) psi (unless noted) bar (unless noted) psi (unless noted) bar psi bar Buna N diaphragm and sealing diaphragms with epoxy coated aluminum 1/8 NPT (female) pressure connections 540 0.8 to 7 wcd 2,0 to 17,4 mbar 0.1 to 1.3 wc 0,2 to 3,2 mbar 30 Hg to 200-1 to 13,8 400 27,6 541 2 to 20 wcd 5,0 to 49,8 mbar 0.2 to 1.6 wc 0.5 to 4,0 mbar 30 Hg to 200-1 to 13,8 400 27,6 542 5 to 50 wcd 12,4 to 124,5 mbar 0.4 to 4.0 wc 1,0 to 10,0 mbar 30 Hg to 200-1 to 13,8 400 27,6 543 10 to 200 wcd 24,9 to 497,8 mbar 0.8 to 12 wc 2,0 to 29,9 mbar 30 Hg to 200-1 to 13,8 400 27,6 544 2 to 20 0,1 to 1,4 0.2 to 2 13,8 mbar to 0,1 30 Hg to 1200-1 to 82,7 2500 172,4 545 5 to 50 0,3 to 3,4 0.4 to 3.2 27,6 mbar to 0,2 30 Hg to 1200-1 to 82,7 2500 172,4 546 10 to 125 0,7 to 8,6 0.7 to 7 48,3 mbar to 0,5 30 Hg to 1200-1 to 82,7 2500 172,4 547 50 to 250 3,4 to 17,2 1 to 15 0,1 to 1,0 30 Hg to 1200-1 to 82,7 2500 172,4 548 100 to 500 6,9 to 34,5 2 to 20 0,1 to 1,4 30 Hg to 1200-1 to 82,7 2500 172,4 temperature Model Chart Model Adjustable Set Point Range Max. Temp Scale Stem/Bulb Division Size Type B117 F C F C F C OD x Length 120 0 to 225-17.8 to 107.2 275 135 10 5 9/16 x 1-7 8 below 1/2 NPT thread (nickel-plated brass) 121 200 to 425 93.3 to 218.3 475 246.1 10 5 9/16 x 1-7 8 below 1/2 NPT thread (nickel-plated brass) Type E117 Bulb OD x length 2BSA -120 to 100-84.4 to 37.8 150 65.6 10 5 3/8 x 2-5/8 5BS -20 to 80-28.9 to 26.7 130 54.4 5 2 3/8 x 5 4BS 25 to 100-3.9 to 37.8 150 65.6 2 1 3/8 x 6-3 4 2BSB 30 to 250-1.1 to 121.1 300 148.9 10 5 3/8 x 2-5/8 3BS 100 to 400 37.8 to 204.4 450 232.2 10 5 3/8 x 2-1 8 8BS 350 to 640 176.7 to 337.8 690 365.6 10 5 3/8 x 3-1 4 Optional immersion stem lengths and capillary lengths are available. 1 1 7 - B - 0 5 w w w. u e o n l i n e. c o m 7

117 Series how to order Building a part number Select a Type Refer to the Type section below. Select a Model Refer to the Model Charts. Select an Option Refer to the Options section. Determine type number based on switch output, enclosure, adjustment and reference. Fill in the type portion of your part number with the corresponding number. Determine model based on adjustable range, deadband and proof pressure. Fill in the model portion of your part number with the corresponding number. Determine option number based on switch output, optional materials or other product enhancements. Fill in the option portion of your part number with the corresponding number. Leave option portion blank if no options are needed. For multiple options: Call United Electric Controls. type Pressure Differential Pressure Temperature DESCRIPTION Type H117 - One SPDT output; epoxy coated enclosure; internal adjustment with High-Low reference scale Type H117K - One SPDT output; epoxy coated enclosure; internal adjustment with High-Low reference scale Type B117 - Immersion stem; One SPDT output; epoxy coated enclosure; internal adjustment with reference dial Type E117 - Bulb and capillary; One SPDT output; epoxy coated enclosure; internal adjustment with reference dial switch Options* 1190 Hermetically sealed, with gold flash contacts, DPDT, 11 amp 125/250 VAC; products set on rising pressure or temperature due to inherent separation of circuits on falling pressure or temperature; specify option 1195 if setting on fall is required; deadband and minimum set point will increase. Not available models 523, 533 1195 Hermetically sealed, with gold flash contacts, DPDT, 11 amp 125/250 VAC; products set on falling pressure or temperature due to inherent separation of circuits on rising pressure or temperature; specify option 1190 if setting on rise is required; deadband and minimum set point will increase. Not available models 523, 533 SENSOR AND OTHER OPTIONS M201 Factory set one switch; specify increasing or decreasing pressure or temperature and set point M277 Range indicated on nameplate in kpa/mpa, factory selected. Not available temperature versions M278 Range indicated on nameplate in Kg/cm 2. Not available temperature versions M405 intrinsic safety compliance for European Union per ATEX standards M406 Intrinsic safety compliance for Russia per Gosgortechnadzor standards M444 Paper ID tag M446 Stainless steel ID tag & wire attachment M449 Surface mounting hardware kit that is required for models 520-535 & 540-548 when surface mounting. Use option code only at time of ordering product, otherwise use surface and pipe mounting kit part number 6361-704 as separate order or for other models. M504 316L stainless steel immersion stem. Available TEMPERATURE Models 120, 121 ONLY M540 Viton construction (deadband and low end range may increase); wetted parts include Viton diaphragm and O-ring. AVAILABLE ON MODELS 700-704 (Viton diaphragm and o-ring, stainless steel pressure connection), AND 540-548 (Viton diaphragms and seals, pressure connections remain aluminum) M550 Oxygen service cleaning; alcohol cleaning to remove residue from the process connection. NOT AVAILABLE PRESSURE MODEL 706 OR TEMPERATURE TYPE E117 SD6286-51 Watertight conduit fitting; converts 7/8 hole to 1/2 NPT (female) fitting 6361-704 Surface and pipe mounting hardware kit for all models. Required for surface mounting models 520-535 & 540-548 if not previously ordered with option M449. *Refer to Electrical Ratings under Specifications on page 3 for DC ratings. 8 w w w. u e o n l i n e. c o m 1 1 7 - B - 0 5

OptionaL sensor material for wc ranges. Available models 520-525 XC001 Aluminum pressure connection, Viton diaphragm, Viton O-ring XC002 Aluminum pressure connection, Kapton diaphragm, Buna N O-ring XC003 Aluminum pressure connection, Kapton diaphragm, Viton O-ring XC004 316L Stainless steel pressure connection, 316L stainless steel diaphragm, Viton O-ring. (Over range pressure is limited to 100 psi) XC005 316L Stainless steel pressure connection, Viton diaphragm, Viton O-ring XC007 316L Stainless steel pressure connection, Teflon diaphragm, Viton O-ring 117 Series Optional sensor materials for corrosive media. Available models 183-189, 483-489 XD002 Hastelloy C diaphragm; NOT NACE COMPLIANT XD003 Monel diaphragm; NOT NACE COMPLIANT XP112 Hastelloy C pressure connection; NOT NACE COMPLIANT XP113 Monel pressure connection; NOT NACE COMPLIANT XR211 Kalrez O-ring XR213 Ethylene Propylene O-ring XR214 Aflas O-ring Optional Flush mount flanges. Available models 565-567 ONLY Flanges conform to ANSI B16.5. Maximum pressure is limited by flange rating. F196 Flush mounted flange, 150#, 1 lap joint, raised face. F198 Flush mounted flange, 300#, 1 lap joint, raised face. options for temperature models UNION CONNECTORS (Dimensional drawings may be found at www.ueonline.com) Option Replacement Number Description Brass W027 SD6213-27 1/2 NPT w/ 3/4 bushing W045 SD6213-45 3/4 NPT W051 SD6213-51 1/2 NPT 304 Stainless Steel W028 SD6213-28 1/2 NPT w/ 3/4 bushing W046 SD6213-46 3/4 NPT W050 SD6213-50 1/2 NPT THERMOWELLS (Dimensional drawings may be found at www.ueonline.com) For all bulb & capillary switches Brass W075 SD6225-75 1/2 NPT with 3/4 NPT adapter bushing, 4 BT W191 SD6225-191 1/2 NPT, 4 BT W118 SD6225-118 1/2 NPT with 3/4 NPT adapter bushing, 7 BT W192 SD6225-192 1/2 NPT, 7 BT 316 Stainless Steel W076 SD6225-76 3/4 NPT, 4.5 BT W193 SD6225-193 1/2 NPT, 4.5 BT W119 SD6225-119 3/4 NPT, 7.5 BT W177 SD6225-177 1/2 NPT, 7.5 BT For all immersion stem switches W139 SD6225-139 3/4 NPT X 1-23/32 BT, BRASS W140 SD6225-140 3/4 NPT X 1-23/32 BT, 316 ST/ST Kapton is a registered trademark of E.I. DuPont. 1 1 7 - B - 0 5 w w w. u e o n l i n e. c o m 9

117 Series options for temperature models W000 IMMERSION STEM AND THERMOWELLS Note: Option W000 is a special Immersion Stem construction that has no external thread. This option fits inside a special thermowell and is secured with a set-screw. Option Description W000 Immersion stem only, Brass W097 Immersion stem and thermowell. Includes W000 stem and 1/2 NPT x 1-23/32 BT Brass thermowell W099 Immersion stem and thermowell. Includes W000 stem and 1/2 NPT x 1-23/32 BT 316 st/st thermowell OPTIONAL LENGTHS: Optional immersion stem lengths to 15 may be available in brass, with or without 316 st/st thermowell. Consult UE for availability. Optional capillary length to *50 may be available in copper or 304 st/st. Consult UE for availability. Armor or Teflon capillary protection may be available to lengths less than or equal to capillary length. Consult UE for availability. * Consult UE regarding repeatability and ambient effects on capillary lengths over 30. dimensional drawings Dimensional drawings for all models may be found at www.ueonline.com Types H117, H117K, B117, E117 A Dimension A Models Inches mm NPT Pressure 171-174 7.63 193.8 1/2 183-186, 483-486 7.56 192.0 1/2 188, 189, 488-489 6.63 168.4 1/2 190-194, 490-494 6.63 168.4 1/2 218 6.56 166.6 1/4 358-376 7.00 177.8 1/4 520-525 8.44 214.4 1/2 530-535 8.00 203.2 1/2 565-567 6.63 168.4 1-1/2 Flush Mount 700-706 6.63 168.4 1/4 Differential Pressure 540-543 8.47 215.1 1/8 544-548 8.53 216.7 1/8 Temperature 120,121 9.38 238.3 Immersion Stem 2BSA-8BS 8.69 220.7 Bulb & Capillary 10 w w w. u e o n l i n e. c o m 1 1 7 - B - 0 5

Types H117, H117K Types B117, E117 COVER REMOVED IN FRONT VIEW COVER REMOVED IN FRONT VIEW PRESSURE SENSORS Models 171-174 Models 183-186, 483-486 Models 188-194, 488-494 Models 218-376, 700-706 Models 520-525 Models 530-535 Models 565-567 1-1/2 Flush Mount DIFFERENTIAL PRESSURE SENSORS temperature SENSORS Models 540-543 Models 544-548 Model 2BSA-8BS Model 120-121 1 1 7 - B - 0 5 w w w. u e o n l i n e. c o m 11

RECOMMENDED PRACTICES AND WARNINGS United Electric Controls Company recommends careful consideration of the following factors when specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and Maintenance instructions provided with unit must be read and understood. To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surges in the system. Operation of the unit up to maximum pressure or temperature is acceptable on a limited basis (e.g., start-up, testing) but continuous operation must be restricted to the designated over range pressure. Excessive cycling at maximum pressure or temperature limits could reduce sensor life. A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low limit switch is necessary for applications where a dangerous runaway condition could result. The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any range point cannot result in an unsafe system condition. Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. When applicable, orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry. Unit must not be altered or modified after shipment. Consult UE if modification is necessary. Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or faulty display. Check unit immediately. Preventative maintenance and periodic testing is necessary for critical applications where damage could endanger property or personnel. Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet. Do not mount unit in ambient temp. exceeding published limits. LIMITED WARRANTY Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period of 24 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Limitation OF Seller s Liability Seller s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, is limited to the limited warranty of repair and/or replacement as so stated in our warranty of product. In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss or expenses of any nature incurred by the buyer or any third party. UE specifications subject to change without notice. For a list of our international and domestic regional sales offices please visit our webpage www.ueonline.com 180 Dexter Avenue, P.O. Box 9143 Watertown, MA 02471-9143 USA Telephone: 617 926-1000 Fax: 617 926-2568 http://www.ueonline.com CP05111000 Be sure to visit www.ueonline.com for the latest information.