HOW TO PLAN AN UNDERGROUND IRRIGATION SYSTEM

Similar documents
Underground irrigation

175 m2 (1,880 sq ft) Kit

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

Valves. Controllers. Valves Two Types

How Do I Install My Garden Master Bucket Garden?

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Instructions For: Installing A Fence to Keep out Raccoons and Woodchucks

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

IRRIGATION DESIGN INSTALLATION GUIDE

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

OTHER HOSES. Lances + Fittings. Hose, Hose Reels, TCF SPIRABEL MD SF SUCTION HOSE TUBCLAIR TRICOFUEL T TAPE LAY FLAT TRESS NOBEL RHS EVERFLOW.

HOW TO DIG A TEST PIT

THERMAL POLITERM WALL AND POLITERM WALL FIX APPLICATION MANUAL. POLITERM WALL / POLITERM WALL FIX. Insulation & Chemicals Division

ambiente Installation Guide AmbiClip Systems more than underfloor Customer: Project: Project Reference: Date:

System Pressure Manager Standard & System Pressure Manager Plus

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Instructions For: Installing McGregor s Small Animal Garden Fence

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

PRESSURISED PAINT CONTAINER

Pressure Compensating (PC) Spray Stakes

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Rapidmain Installation Guide

COUNTER CURRENT UNIT. Instruction Manual

PRO SINK -R 1 and 2. Dilution system CONTENTS

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Cool Springs and Clarksville store call Cookeville store call Bowling Green store call

TECHNICAL DATA. Trimpac 244a. September 16, 2013

EFLOW GUIDE. IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

SIMPLAIR PIPING TOOL. JXT Company

LEVEL 3 CERTIFICATE IN AUTOMATIC TURF IRRIGATION SYSTEMS ASSESSMENT SCHEDULE

Installation Guide For Spillways & LED Light Bars

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Replacement of Interchangeable Membrane

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

High Performance BSP Dial Up Pattern Pressure Reducing Valve

ambiente Installation Guide AmbiPlate more than underfloor Customer: Project: Project Reference: Date:

Installation and Training Manual

Gas Welding Hoses and connections, the weak link

To purchase replacement parts and accessories, or to obtain technical assistance, visit:

Irrigation System Winterization and Pressurization Procedures

Intro: by firechim on October 3, 2013

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Troyer s Gourd Rack 8 unit F R H O P

Bottle Rocket Launcher P4-2000

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

WORKHOLDING APPLICATION BOOKLET

Budget Range Operators Handbook

K-Line Irrigation Pod Packs

AIR GAP (AG) Low Hazard High Hazard

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

INSTALLING AN INEXPENSIVE AIR LINE TO MEASURE WATER DEPTHS IN WELLS

Sterisil Ac+ Installation & Operating Manual

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

The Glockemann Pump Site & Installation Guide

User's Manual. MixRite TF 10. Edition 05.08

Pressure switches for air and water CS

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

Reverse Osmosis System Installation Guide and Operation Manual.

Appendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media

Warning: NEVER ALTER TEST EQUIPMENT

Apricot Kitchen Sink Tap

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Materials : Brass body dezincification-resistant up to DN1 1/4

THERMOSTATIC MIXING VALVES

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

North American Orifice Metering System

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Installation Guide Wall Mounted Angled Flagpole

SIZING OF WATER PIPING SYSTEM

Technical Data Sheet TI-F50 Locking Units series KFH

AutoDrill s OUTSTANDING FEATURES

Squeegee Unit for MRS Multi-Recovery System

NEXT GENERATION FLEX FENCE

HERZ-Motorised flow controler

K-LINE Irrigation Farm Packs

GYROSTATIC DELIVERY TECHNIQUE By Macka Jensen

Manual Actuated Boiler Blowdown Valves

Engineered Air Nozzles reduce noise levels and air costs.

INSTRUCTION MANUAL CZ 630/631

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.

Hyquest Solutions Pty Ltd

ambiente Installation Guide AmbiScreedboard system more than underfloor Customer: Project: Project Reference: Date:

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Winter Shut Down Procedure

SIZING OF WATER PIPING SYSTEM

Transcription:

HOW TO PLAN AN UNDERGROUND IRRIGATION SYSTEM CHECK THE AVAILABILITY OF WATER MEASURE THE WATER PRESSURE Close all household taps. Fit a pressure gauge to an outdoor tap, then open it completely (STATIC pressure). Ask your plumber to lend you a pressure gauge, or hire one. Take the measurement at different times during the day and night. Container capacity (e.g. 10 litres) Q= x 60= 10 x 60=30 litres/min Time taken (e.g. 20 seconds) 20 Q= flow MEASURE THE AVAILABLE WATER FLOW Simply time how long it takes to fill a recipient with known volume. PLANNING Use a compass to mark the circumference or circle sectors reached by each sprinkler, until the entire surface is covered. For best results, position the 90 sprinklers in the corners of the patches to be watered, s along garden strips, and 360 sprinklers in open spaces. The examples given in this booklet show the arrangement necessary to cover long and narrow areas evenly. The circumferences, as seen in the examples, meet to guarantee total coverage of ground and the even distribution of water in all points. When arranging the sprinklers, refer to the recommended spacing indicated in the tables on page 40. DIVIDE THE AREA INTO CIRCUITS Referring to the sprinkler output table, write in the water consumption (in l/min.) next to each sprinkler. Group the sprinklers into distinct areas (use different colours), summing progressively the water consumption. Make sure that the water consumption in each area does not exceed the available flow. You should aim at creating a well-balanced system, i.e. each circuit should have the same water consumption.

43 MARK THE LAYOUT OF TUBES Starting from the point where the solenoid valves controlling each single circuit will be installed, mark in the tube connecting each valve to the sprinklers (previously grouped into areas), thereby drawing independent valve circuits. Since trenches will have to be dug to lay the pipes, mark in straight lines, avoiding as far as possible driveways, terraces and other obstacles. The diagrams on the following pages give examples of the positioning of sprinklers. Bear in mind that: - 90 sprinklers should be positioned in garden corners; - s should be positioned along garden strips; - adjustable sprinklers are best used for 270 or irregular angles; - 360 sprinklers should be positioned in central open spaces. 90 sprinkler adjustable sprinkler adjustable sprinkler Irrigatori a 360 90 sprinkler adjustable sprinkler 90 sprinkler

FLOW RESISTANCE Don't forget pipe FLOW RESI- STANCE: refer to the pressure loss table indicating the values to be subtracted from the original static pressure available. The DYNAMIC pressure obtained should be sufficient to guarantee correct sprinkler operation. FLOW RESISTANCE IN 3/4" AND 1" DIAMETER TUBES (IN BAR) FOR EVERY 10 METRE LENGTH Flow l. / min Int. diam. 3/4" Int. diam. 1" 18 0.0592 0.0202 24 0.0997 0.0341 30 0.1493 0.0511 36 0.2078 0.0712 42 0.2747 0.0941 PRACTICAL DIY INSTALLATION Go into the garden and turn your project into an efficiently operating reality. A set of solenoids controls the opening and closing of irrigation circuits. The water supply line to the valves is subject to the entire amount of static pressure (when the circuit is closed); for this reason it should be made from a watertight metal pipe. As a rule, the diameter of the tube connecting the valves to the service line should not be less than the diameter of the valves. It is also a good idea to fit a gate valve upstream to shut off the entire system when necessary, for example when maintenance work is required.

Once the solenoid valves have been connected to the main water supply pipe, take your plan and mark the path of tubes of each sprinkler circuit. Plant a stake at each point where a sprinkler is to be installed. Now join the stakes with string (or with chalk powder on the ground) to trace the line of each circuit tube, from the solenoid valve to the sprinklers. Unroll the polyethylene coil, from the valves to the stakes, along the marked path. Put the T or connector couplings and the drainage valves in the position for installation. Straighten the tube properly before cutting it to length (better too long than too short). Use a hacksaw to cut the tube; clean cut ends with a scraper before fitting compression connectors to ensure a completely watertight connection. 45 To avoid damaging the lawn, heap the dug earth on plastic sheeting, then remove when finished. Use a spade to dig a trench at least 20-25 cm deep. This won t take much of an effort, and should be enough to protect the pipes against winter frost. At each stake, place a sprinkler and the threaded bracket extension coupling (before applying the extension, drill a hole in the tube with a 10 mm bit) on the ground.

between the sprinklers and the valves. Fix the sprinklers in a vertical position (tie them to the stakes with string), then open the valve (in sequence) to test circuit operation. Shift the sprinklers as required to achieve perfect coverage of the watered ground. Once the desired coverage is obtained and the circuits have been arranged, lay the tube in the trenches. Make sure that the sprinklers are positioned flush to the terrain surface; the threaded extension supporting the sprinkler can be segmented to adjust sprinkler height. Now connect up all tube lengths At the end of installation, the circuit should be emptied of all residues and earth. To do so, simply unscrew the head from each sprinkler and open the valves; the water pressure will flush the circuit clean. Screw the heads back on the sprinklers, then fill in the trenches and level to the surrounding area (and the upper edge of the sprinklers). Your irrigation system is now complete and ready for operation, controlled by an automatic watering timer.

UNDERGROUND IRRIGATION Reasons for choosing a Claber Rainjet underground irrigation system There are a lot of good reasons for installing an underground automatic irrigation system: the convenience of having your garden automatically watered, even when you re away or on holiday (no need to find someone to come and look after the garden); the knowing that all areas of the garden will get the necessary amount of water, without waste, assuring maximum economy; no hoses above ground to get in the way of the lawn mower sprinklers are flush to the level of the lawn and are hardly noticeable; silent operation, causing no disturbance to neighbouring homes; increased property value no well-tended lawn can today afford to do without an automatic irrigation system. WATCH OUT FOR THE COLD! In areas subject to frosts, a drainage valve should be fitted at the lowest point of each irrigation line. When the circuit is closed and no water is circulating, the valve automatically opens to release residual water, which otherwise if left to freeze could damage the hose. When water flows through the hose, the drainage valve automatic locks.