POWERBALL HCI-T Metal halide lamps with ceramic technology for enclosed luminaires Areas of application _ Shop interiors, shop windows _ Shopping arcades _ Foyers, reception areas _ Museums, exhibitions _ Exhibition halls and trade fairs _ Factories and workshops _ Approved only for use in enclosed luminaires _ Outdoor applications only in suitable luminaires Product benefits _ Very high efficiency _ Good to excellent color rendering _ Very good color stability _ UV values significantly below the maximum permitted thresholds to IEC 61167 thanks to UV filter Product features _ POWERBALL ceramic technology _ Light colors: warm white (830 WDL), neutral white (942 NDL) _ Average lifetime: 15,000 h (operation with ECG with 70 400 Hz square-wave current) _ Average lifetime:,000 h (with magnetic control gear) _ HCI-T 50 W only for operation with ECG with 70 400 Hz square-wave current POWERBALL HCI-T Page 1 of 7
Technical data Electrical data Photometrical data Product description Nominal wattage Luminous flux Luminous efficacy Color rendering index Ra Color temperature Light color HCI-T 35 W/830 WDL PB 35,00 W 3700 lm 1) 95 lm/w 2) 85 2940 K 829 HCI-T 35 W/942 NDL PB 35,00 W 3400 lm 1) 87 lm/w 2) 91 3750 K 938 HCI-T 70 W/830 WDL PB 70,00 W 7400 lm 1) 101 lm/w 2) 89 3000 K 830 HCI-T 70 W/942 NDL PB 70,00 W 6800 lm 1) 93 lm/w 2) 95 3890 K 939 HCI-T 100 W/830 WDL PB 100 W 11300 lm 5) 113 lm/w 2) 86 3000 K 830 HCI-T 100 W/942 NDL PB 100,00 W 10500 lm 1) 105 lm/w 2) 95 4000 K 940 HCI-T 150 W/830 WDL PB 150.00 W 15100 lm 6) 103 lm/w 7) 89 3000 K 830 HCI-T 150 W/942 NDL PB 150.00 W 14700 lm 6) 100 lm/w 7) 95 3950 K 942 Product description Rated LLMF at 2,000 h Rated LLMF at 4,000 h Rated LLMF at 6,000 h Rated LLMF at 8,000 h Rated LLMF at,000 h UV protection HCI-T 35 W/830 WDL PB 0,86 0,82 0,78 0,75 0,73 Sì HCI-T 35 W/942 NDL PB 0,92 0,91 0,91 0,89 0,84 Sì HCI-T 70 W/830 WDL PB 0,85 0,81 0,80 0,78 0,75 Sì HCI-T 70 W/942 NDL PB 0,87 0,81 0,78 0,77 0,76 Sì HCI-T 100 W/830 WDL PB 0,88 0,83 0,80 0,79 0,76 Sì HCI-T 100 W/942 NDL PB 0,95 0,90 0,87 0,83 0,80 Sì HCI-T 150 W/830 WDL PB 0.87 0.81 0.78 0.75 0.69 Yes HCI-T 150 W/942 NDL PB 0.92 0.85 0.82 0.78 0.74 Yes Dimensions & weight Temperatures & operating conditions Lifespan Product description Diameter Length Maximum permitted outer bulb temperature Maximum permitted pinch temperature at 2,000 h HCI-T 35 W/830 WDL PB 20,0 mm 100,0 mm 500 C 350 C 0,99 0,98 HCI-T 35 W/942 NDL PB 20,0 mm 100,0 mm 500 C 350 C 0,99 0,98 HCI-T 70 W/830 WDL PB 20,0 mm 100,0 mm 500 C 350 C 0,99 0,98 at 4,000 h POWERBALL HCI-T Page 2 of 7
Dimensions & weight Temperatures & operating conditions Lifespan Product description Diameter Length Maximum permitted outer bulb temperature Maximum permitted pinch temperature at 2,000 h HCI-T 70 W/942 NDL PB 20,0 mm 100,0 mm 500 C 350 C 0,99 0,98 HCI-T 100 W/830 WDL PB 20,0 mm 105,0 mm 500 C 350 C 0,99 0,98 HCI-T 100 W/942 NDL PB 20,0 mm 105,0 mm 500 C 350 C 0,99 0,98 HCI-T 150 W/830 WDL PB 25.0 mm 105.0 mm 550 C 350 C 0.99 0.98 HCI-T 150 W/942 NDL PB 25.0 mm 105.0 mm 550 C 350 C 0.99 0.98 at 4,000 h Additional product data Product description at 6,000 h at 8,000 h at,000 h Lifespan B50 Operation mode LLMF/LSF HCI-T 35 W/830 WDL PB 0,97 0,96 0,80 15000 h 3) ECG G HCI-T 35 W/942 NDL PB 0,97 0,96 0,80 15000 h 3) ECG G HCI-T 70 W/830 WDL PB 0,97 0,96 0,80 15000 h 3) ECG G HCI-T 70 W/942 NDL PB 0,97 0,96 0,80 15000 h 3) ECG G HCI-T 100 W/830 WDL PB 0,97 0,96 0,80 15000 h 3) ECG HCI-T 100 W/942 NDL PB 0,97 0,96 0,80 15000 h;000 h 3) ECG G HCI-T 150 W/830 WDL PB 0.97 0.96 0.80 15000 h 8) ECG G HCI-T 150 W/942 NDL PB 0.97 0.96 0.80 15000 h 8) ECG G Base (standard designation) Capabilities Product description Dimmable Burning position Enclosed luminaire required Certificates & standards Hot restart Energy efficiency class Energy consumption HCI-T 35 W/830 WDL PB No Universale Sì No A+ 43 kwh/1000h HCI-T 35 W/942 NDL PB No Universale Sì No A+ 43 kwh/1000h HCI-T 70 W/830 WDL PB Sì 4) Universale Sì No A+ 81 kwh/1000h HCI-T 70 W/942 NDL PB Sì 4) Universale Sì No A+ 81 kwh/1000h HCI-T 100 W/830 WDL PB Sì 4) Universale Sì No A+ 110 kwh/1000h HCI-T 100 W/942 NDL PB Sì 4) Universale Sì No A+ 110 kwh/1000h POWERBALL HCI-T Page 3 of 7
Capabilities Product description Dimmable Burning position Enclosed luminaire required Certificates & standards Hot restart Energy efficiency class Energy consumption HCI-T 150 W/830 WDL PB Yes 9) Any Yes No A+ 162 kwh/1000h HCI-T 150 W/942 NDL PB Yes 9) Any Yes No A+ 162 kwh/1000h Country specific categorizations Product description HCI-T 35 W/830 WDL PB HCI-T 35 W/942 NDL PB HCI-T 70 W/830 WDL PB HCI-T 70 W/942 NDL PB HCI-T 100 W/830 WDL PB HCI-T 100 W/942 NDL PB HCI-T 150 W/830 WDL PB HCI-T 150 W/942 NDL PB ILCOS MT/UB-35/830-H/E/SL- G-20/90 MT/UB-35/942-H/SL-G- 20/90 MT/UB-70/830-H/SL-G- 20/90 MT/UB-70/942-H/SL-G- 20/90 MT/UB-100/830-H/SL- G-20/100 MT/UB-100/942-H/SL- G-20/100 MT/UB-150/830-H/SL- G-26/100 MT/UB-150/942-H/SL- G-26/100 1) In funzione con alimentatore elettronico con corrente a onda quadra 70 400 HzIl funzionamento con alimentatore magnetico può essere meno efficace 2) In funzione con alimentatore elettronico con corrente a onda quadra a bassa frequenza, 70 400 Hz. Il funzionamento con alimentatore elettromagnetico può essere meno efficace. 3) A alimentatore elettronico 4) Abbinato a POWERTRONIC PTo 5) In operation with low frequency square wave electronic ballast, 70 400Hz. Operation with electromagnetic ballast may be less efficient. 6) In operation with electronic control gear with 70 400 Hz square-wave current.operation with magnetic ballast can be less efficient POWERBALL HCI-T Page 4 of 7
7) In operation with low frequency square wave electronic ballast, 70 400 Hz. Operation with electromagnetic ballast may be less efficient. 8) At ECG 9) In combination with POWERTRONIC PTo HCI-T 35 W/830 WDL PB, HCI-T 35 W/942 NDL PB, HCI-T 70 W/830 WDL PB, HCI-T 70 W/942 NDL PB, HCI-T 100 W/830 WDL PB, HCI-T 100 W/942 NDL PB, HCI-T 150 W/830 WDL PB, HCI-T 150 W/942 NDL PB HCI-T 35 W/830 WDL PB, HCI-T 70 W/830 WDL PB, HCI-T 100 W/830 WDL PB, HCI-T 150 W/830 WDL PB HCI-T 35 W/942 NDL PB, HCI-T 70 W/942 NDL PB, HCI-T 100 W/942 NDL PB, HCI-T 150 W/942 NDL PB System guarantee For the vast majority of our lamps we are offering an extended system guarantee in conjunction with OSRAM POWERTRONIC control gear. Application advice POWERBALL HCI-T Page 5 of 7
For more detailed application information and graphics please see product datasheet. Logistical Data Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4008321681850 HCI-T 35 W/830 WDL PB Shipping carton box 4008321681898 HCI-T 35 W/942 NDL PB Shipping carton box 4008321678430 HCI-T 70 W/830 WDL PB Shipping carton box 4008321678522 HCI-T 70 W/942 NDL PB Shipping carton box 4008321682963 HCI-T 100 W/830 WDL PB Shipping carton box 4008321682987 HCI-T 100 W/942 NDL PB Shipping carton box 4008321682055 HCI-T 150 W/830 WDL PB Shipping carton box 4008321682079 HCI-T 150 W/942 NDL PB Shipping carton box 180 mm x - x - 3.98 dm³ 586.00 g 180 mm x - x - 4.01 dm³ 586.00 g 180 mm x - x - 4.03 dm³ 586.00 g 180 mm x - x - 4.03 dm³ 600.40 g 180 mm x - x - 4.03 dm³ 587.20 g 180 mm x - x - 3.90 dm³ 587.20 g 180 mm x 161 mm x 139 mm 4.03 dm³ 674.80 g 180 mm x 156 mm x 139 mm 3.90 dm³ 674.80 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. References / Links For more information on the system guarantee and the terms and conditions of the guarantee visit POWERBALL HCI-T Page 6 of 7
www.osram.com/system-guarantee Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. POWERBALL HCI-T Page 7 of 7