Operating instructions Capacitive sensor KIA (M30) / / 2010

Similar documents
Operating instructions Capacitive sensors KG AC (M18) / / 2010

Operating instructions Binary level sensor LI / / 2013

Operating instructions Pressure sensor. PN422x / / 2013

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

HBLT-A1 LIQUID LEVEL SENSOR

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

A4s Operation Manual

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Roller AC Servo System

VERTICAL AIR COMPRESSORS

GAS FUEL VALVE FORM AGV5 OM 8-03

BUBBLER CONTROL SYSTEM

Safety Manual VEGAVIB series 60

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Safety Manual VEGAVIB series 60

VERTICAL AIR COMPRESSORS

Technical Data. Dimensions

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

M-5071/1111. Electronic Pressure Switch PSW14 series

Operating instructions Pressure sensor. PP00xE /00 10/2011

PRAHER PLC-MP AQUASTAR MANAUL 2009

BUBBLER CONTROL SYSTEM

Technical Data. Dimensions

EC214 EC215 - EC215R Bench Conductivity Meters

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Technical Data. Dimensions

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

SVEA II GSM Connector User Manual

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

PSSI 3 High Voltage Metal-Enclosed Switchgear

SPECIFICATIONS APCEPH1

MP15 Jockey Pump Controller

Actuating elements for ComEx

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Operating Instructions of BROSA tension load cells, types 0111, 0113

Operating instructions Installation instructions To be kept in the vehicle!

Technical Data. General specifications. Rated operating distance s n 2 mm

AHE58/59 AC Servo System

Safety Manual OPTISWITCH series relay (DPDT)

Control units. Installation and operating instructions Series: DP-Control

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Control Units for Oil+Air Lubrication

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

CCT-7320/ROC-2313 Reverse Osmosis Controller

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

GATE 2 Part No

Level MEASUREMENT 1/2016

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

1 Characteristics: 2 Installation: INSTALLATIONguide. inteo SOLIRIS IB

Guidelines to the standard IEC60601

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

NIV EAU MATIC ST User Manual Made in Canada

Technical Data Sheet MF010-O-LC

AUTOMATIC GAS MANIFOLDS

I003 Lock Out - Tag Out - Try Out. Document information

Operating Manual for the Evance Iskra R9000 Wind Turbine

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

New AQF Filter Polymer Filtration System

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

FAULT CODE TROUBLESHOOTING INDEX

Ventam 85 Installation & Commissioning Instructions

Product Overview. Product Description CHAPTER

BS ml Bottle Sampling Unit

HI 2314 HI 2315 HI 23151

LOCKOUT SYSTEM AND POLICIES

User manual CF8-D/W-IN

Manual Oxygen Analyzer A4009T

This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA. WARNING CAUTION

Technical Data. Dimensions

LVU2800 Series. Ultrasonic Level Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Installation, use and maintenance instructions. Gas burner (5)

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO

Operating and maintenance manual Filter and reducing station Series / 1.0

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

MODEL GT820 OXYGEN SENSOR

FPD20 Series. Gear wheel flow sensor

Transcription:

Operating instructions Capacitive sensor KIA (M30) UK 704182 / 03 07 / 2010

Contents 1 Preliminary note 3 2 Safety instructions 3 3 Functions and features 3 3.1 Application examples 4 4 Installation 4 4.1 Notes on flush and non-flush installation 4 4.2 Notes on installation in tanks 5 5 Electrical connection 5 5.1 Wiring 6 6 Operating and display elements 6 7 Settings 6 7.1 Basic teach empty state 6 7.2 Adjustment teach full state 7 7.3 Modified basic teach empty state 8 7.4 Locking / unlocking 9 8 Operation 10 9 Approvals 10 10 Maintenance, repair and disposal 10 2

1 Preliminary note Operating elements are indicated as follows: Example: [OUT OFF] = Button "OUT OFF". An instruction is indicated by " ". Example: Mount the unit as shown. A reaction to the action is indicated by ">". Example: > Yellow LED on. Important note Non-compliance can result in malfunctions or interference. UK 2 Safety instructions Please read the operating instructions prior to set-up of the devunit. Ensure that the product is suitable for your application without any restrictions. The unit conforms to the relevant regulations and EC directives. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. Installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. 3 Functions and features Capacitive sensor for monitoring levels of liquids and dry bulk material. Automatic adjustment to the medium to be detected by means of programming buttons. 3

3.1 Application examples 4 Installation 4.1 Notes on flush and non-flush installation For flush installation of non-flush units the sensor properties change and the sensor can remain permanently switched (loss of function). Observe the free space around the sensing face. flush non-flush Adhere to the minimum distances when mounting several sensors of the same type. 3x S n 4

4.2 Notes on installation in tanks Mount the unit as shown: In contact with the medium In case of liquids use a mounting adapter (e.g. E11033). UK Not in contact with the medium (only for non-metallic tanks) You can find mounting adapters at: www.ifm.com Select your country Data sheet direct: 5 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Disconnect power Connect the unit Operating voltage UB = 10...36 V DC (60 C) / U B = 10...30 V DC (80 C) Current rating I = 100 ma 5

5.1 Wiring p-switching (type...fpkg...): output with autodetect p-switching or n-switching (type...fkg...): PNP NPN On power up, the unit detects automatically if the output is connected to L- (= PNP) or to L+ (= NPN). Disconnect the unit to acknowledge a change of the load connection. 6 Operating and display elements 1: 2: 3: 4: sensing face threaded sleeve programming buttons LED ring yellow 7 Settings 7.1 Basic teach empty state Using the basic teach empty state the unit suppresses the installation environment. The basic teach empty state resets the unit, an adjustment teach already carried out is deleted. Empty the tank until the level is at least 20 mm below the sensor 6

Set the unit as normally open (output closes when the tank is full): Press [OUT OFF] for min. 2 s (max. 6 s). >> While pressing the pushbutton the LED flashes slowly. After releasing the pushbutton, the LED goes out. Set the unit as normally closed (output opens when the tank is full): Press [OUT ON] for min. 2 s (max. 6 s). >> While pressing the pushbutton the LED flashes slowly. After releasing the pushbutton, the LED lights continuously. 2-6 s 2-6 s UK The unit is now ready for operation. For the detection of media with a low dielectric constant (e.g. plastic granulates or oils) no further setting is required. 7.2 Adjustment teach full state Necessary for aqueous media. The sensitivity of the unit is optimised. Later on, the adjustment teach full state can be repeated at any time, an adjustment teach empty state already carried out is not affected. A basic teach empty state must be carried out prior to the adjustment teach full state ( chapter 7.1 Basic teach empty state)! If it is not possible to empty the tank, a basic teach empty state can be carried out by simulating the empty state (e.g. adjustment when not installed, adjustment at a higher position). For optimum function it is necessary to carry out the "modified basic teach empty state" ( chapter 7.3 Modified basic teach empty state) when the tank is emptied the next time. 7

Fill the tank until the sensing face of the unit is covered. >> For NO the LED lights, for NC it goes out. Set the unit as normally open (output closes when the tank is full): Press [OUT ON] for min. 6 s. >> While pressing the pushbutton the LED first flashes slowly, after 6 s more quickly. After releasing the pushbutton, the LED lights continuously. Set the unit as normally closed (output opens when the tank is full): Press [OUT OFF] for min. 6 s. >> While pressing the pushbutton the LED first flashes slowly, after 6 s more quickly. After releasing the pushbutton, the LED goes out. > 6 s > 6 s 7.3 Modified basic teach empty state Recommended for deposits in the tank. Deposits are largely suppressed. This is also recommended if it has not been possible to carry out a basic teach empty state (e.g. if the sensor is set up on a full tank; details: chapter 7 Adjustment teach full state) Later on, the modified basic teach empty state can be repeated at any time, an adjustment teach full state already carried out is not affected. 8

Empty the tank until the level is below the sensing face of the unit. >> For NO the LED goes out, for NC the LED lights. Set the unit as normally open (output closes when the tank is full): Press [OUT OFF] for min. 6 s. >> While pressing the pushbutton the LED first flashes slowly, after 6 s more quickly. After releasing the pushbutton, the LED lights continuously. Set the unit as normally closed (output opens when the tank is full): Press [OUT ON] for min. 6 s. >> While pressing the pushbutton the LED first flashes slowly, after 6 s more quickly. After releasing the pushbutton, the LED goes out. > 6 s > 6 s UK 7.4 Locking / unlocking The unit can be electronically locked to protect it against unintentional setting. To lock press [ OUT ON] and [OUT OFF] simultaneously for 10 s. >> Acknowledgement: LED state (yellow) changes for a short time (the lit LED goes out briefly or the LED which is not lit lights briefly). To unlock repeat this step. 10 s If the unit does not react, it may be locked. 9

8 Operation Check whether the unit operates correctly. Bring about a sensor response by taking suitable measures. Display by LEDs (independent of the programmed output configuration); LED yellow OFF: LED yellow ON: switching output disabled switching output enabled 9 Approvals For units with culus approval and the scope of validity culus: The device shall be supplied from an isolating transformer having a secondary Listed fuse rated as noted in the following table. Overcurrent protection Control-circuit wire size AWG [mm 2 ] Maximum protective device rating [A] 26 0.13 1 24 0.20 2 22 0.32 3 20 0.52 5 18 0.82 7 16 1.3 10 10 Maintenance, repair and disposal The operation of the unit is maintenance-free. To ensure a correct function: Keep the sensing face and a clear space, if any, free from deposits and foreign bodies. When removing the unit or changing the medium, a new adjustment might be necessary. It is not possible to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 10 Technical data and further information at www.ifm.com Select your country Data sheet direct: