PROTEGO Deflagration Flame Arresters. Volume 3. Volume 3. for safety and environment

Similar documents
Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof

PROTEGO Pressure/Vacuum Relief Valves. Volume 7. with Flame Arrester - end-of-line. Volume 7. for safety and environment

PROTEGO Pressure/Vacuum Relief Valves. Volume 7. w ith Flame Arrester - end-of-line. for safety and environment

PROTEGO Pressure and Vacuum Relief Valves. Volume 6. in-line. Volume 6. for safety and environment

PROTEGO Pressure and Vacuum Relief Valves. Volume 6. in-line. Edition for safety and environment

PROTEGO Tank Accessories and Special Equipment. Volume 8. Volume 8. for safety and environment

Blanketing Valve ZM-R. low pressure reducing valve

SITRANS P measuring instruments for pressure

Flow metering in gases Introduction to COMBIMASS family

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Pressure Measurement Single-range transmitters for general applications

Monitoring device NTS 30

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

SITRANS P measuring instruments for pressure

GA24 Technical Datasheet

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

FLAME ARRESTOR MODEL L76C-UF

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Torque Tube TB300 Digital Transmitters

SAFE/REYCO. More than 35,000 variations in DIN EN and ASME. NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C)

Mass Flow Meter (MFM) for Gases

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Flow Measurement SITRANS F C

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

PROTEGO Braunschweiger Flammenfilter GmbH

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

Level switches Series LD Vibrating fork level switch for liquids and solids

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Series MG Mixing Tubes

Combined Pressure / Vacuum Relief Valve KITO VD/o

North American Orifice Metering System

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

Level switches Series LD Vibrating fork level switch for liquids and solids

North American Simplex Basket Strainers for Gas and Oil

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Expert Hydrostatic Level Transmitters

776 Cryogenic Safety Valve

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Ratio Regulator Zero Governor. FRG/6 Series

Norval Pressure regulator

SV60 Safety valves. for use with steam, gas and liquids

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

OPTIBAR P 1010 C Technical Datasheet

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

Tank Blanketing Regulators

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

SIHI LPH-X - Liquid Ring Compressors

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Service and installation must be performed by a trained/experienced service technician.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

DAV Series. DAV-MH Air Release & Vacuum Break Valves

The evolution of the Ex-proof flame path

VA FLOWMETERS Supplementary Instructions

3-way control valves VK 3

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Anderson Greenwood Type 4142 piped away pressure relief valves

Self-operated Pressure Regulators for special applications

picture 1: PROTEGO VD/SV

Technical Data Sheet T 2025

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Pressure Relief Valves. SPV, SPVF direct operated

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

CAST IRON SAFETY VALVE TYPE 6301

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

2-Port Seat Valves with Flange, PN 16

Mass Flow Controller (MFC) for Gases

Flow Measurement SITRANS F C

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

deltaflowc deltaflowc Venturi or Probe

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

6-5 Maintenance Manual

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

RR 16 Commercial & Industrial Regulator

Transcription:

PROTEGO Deflagration Flame Arresters Volume 3 Volume 3

Deflagration Flame Arrester Function and description The function of fl ame arresters in the various combustion processes and the location of their installation is discussed in Technical Fundamentals (see Vol. 1). In this chapter, we present PROTEGO in-line deflagration flame arresters which are installed in pipelines and as components on equipment (e.g. blowers, vacuum pumps). With the goal of protecting process units PROTEGO defl a- gration fl ame arresters are state-of-the-art safety devices that are used in systems handling explosive mixtures to mitigate defl agrations. They reliably suppress the effect of a defl agration in the pipelines near a potential ignition source, extinguish the fl ame, and protect systems that cannot withstand the pressure of an explosion. In cases where a stable fl ame can continue on the fl ame arrester element, in-line defl agration fl ame arresters only provide protection for a limited time. If this time can be exceeded, an additional measure has to be provided for mixtures that continue to fl ow continuously. The main component is the PROTEGO fl ame arrester unit (1), which takes the energy from the defl agration and extinguishes the fl ame in narrow gaps. The fl ame arrester unit is modular, consisting of several FLAMEFILTER discs (2) installed within the FLAMEFILTER cage (3). The number of FLAMEFILTER discs and their gap size depend on the devices intended use and depend on process parameters such as temperature, pressure, vapour group of the handled gases. PROTEGO fl ame arrester unit As a component of equipment, defl agration fl ame arresters are type-tested and approved along with the equipment (OEM part, e.g. vacuum pumps, blowers). They are not available separately as independent defl agration fl ame arresters. A broad variety of types, designs, nominal diameters and materials are available. In addition, we are able to develop customized solutions for our clients at our state-of-the-art test facility, which is the largest privately owned research center in fl ame arrester business worldwide. Special features and advantages The devices can be distinguished and selected based on the following main criteria: Components for equipment (e.g. blowers, vacuum pumps) or devices to be installed in pipelines handling gas or vapour. Special operating conditions (e.g. elevated operating pressures or temperatures) that go beyond classifi ed values of different test standards may have to be considered. It is important to categorize the products or components into explosion groups, depending on their MESG, to select the suitable type of protection from the various designs. The suitable or required approved device must be selected from the great variety of devices that have been tested and approved. The basic designs of the housing are concentric, eccentric and with a easy access cover for simple disassembly of the fl ame arrester unit. The system specifi cation must be considered when choosing the required nominal diameters and types of connection. A heating jacket may be necessary for problematic applications. Special designs offering unidirectional or bidirectional protection can be provided as well as versions for critical fluids (such as products that tend to polymerize or crystallize) and special product properties. Defl agration fl ame arresters in pipelines for protection of process units can only be used if approved for such application. The distance from the potential ignition source is limited and is expressed by (L/D) max for the individual device. A fi re may result on the fl ame arrester unit if the mixture continues to fl ow. As the defl agration fl ame arrester is only approved for a specifi c time period, the device should be equipped with a temperature sensor to detect temperature increase caused by a fl ame. Should the temperature increase over a certain level, a suitable measure such as nitrogen purging should be used. Deflagration arresters as specific components for OEM equipment (e.g. blowers or vacuum pumps) are specifically optimized and tested along with the equipment. Preferred applications Protection of pipelines; containers in chemical, petrochemical, and pharmaceutical processing systems; loading systems; gas collection systems; exhaust combustion systems; fl are systems; landfi lls and biogas systems and sewage treatment plants. All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 86 KA / 3 / 0412 / GB

Installation and servicing PROTEGO defl agration fl ame arresters are preferably installed as close as possible to the potential ignition source. Typically any orientation of installation can be chosen, but the direction of fl ow needs to be taken into account for designs with temperature sensors. No pipes with a nominal diameter greater than the nominal diameter of the device shall be connected to the defl a- gration fl ame arrester. Given the modular design of the PROTEGO fl ame arrester unit, any type of defl agration fl ame arrester is extremely easy to service. For servicing reasons, the location of the fl ame arrester must be planned to be very accessible; a hoist must be provided if the fl ame arrester is heavy. Servicing is easy for trained personnel. PROTEGO defl agration fl ame arresters are used in areas subject to explosion hazards. Devices have to be selected that match the intended use. The manufacturer s certifi cate of conformity provides the boundary conditions for which the device is suitable. The user has to document proper use in accordance with applicable safety guidelines or standards. Selection The following main points should be considered for choosing the correct device for your application: In-line flame arrester or component on equipment (e.g. vacuum pump or blower) Sizing The nominal diameter of the device is determined or checked in the p/v. performance diagram. A safety factor must be considered when the fl uid has a tendency to clog the fl ame arrester element. Given: Volume fl ow m 3 /h or CFH Given: Max. all. pressure drop p mbar or inch W.C. Desired: Nominal diameter of the defl agration fl ame arrester airfl ow in thousands of CFH Procedure: Intersection of the lines with volume fl ow and maximum allowable pressure drop lies above or on the desired nominal diameter curve of the device Given: Volume fl ow m 3 /h or CFH Given: Nominal diameter of pipe Desired: Pressure drop p mbar or inch W.C. Procedure: Intersection of the lines with the volume fl ow and nominal diameter curve of the device, horizontal straight line leads to the desired fl ow resistance Explosion group of gas mixture Standard or special operating conditions (pressure and temperature) Finally, the following criteria are reviewed and considered Nominal diameter and type of connection Approvals according to ATEX, FM, Gost-R, GL, etc.. Concentric or eccentric design or designed with an easy access cover Heating jacket or heating coil Critical fluids Unidirectional or bidirectional protection Based on this initial selection, the additional details such as materials, coatings, etc. can be requested or specifi ed. If no suitable device can be selected, please contact us. Special designs and approvals are available upon request. pressure drop p (mbar) fl ow rate V. (m³/h) Instructions on calculating the volume fl ow or infl uence of density are found in Technical Fundamentals (Vol. 1). After all the steps are complete, the device can be specifi ed and ordered. For special cases, please fi ll out the questionnaire with the process data in Vol. 1, that will serve as information for providing a quote. pressure drop p inch W.C. 87

Selection Guide PROTEGO Deflagration Flame Arrester Type Size In-line defl agration fl ame arrester Explosiongroup Approvals Special designs for higher temperatures and pressures for critical medium (polimerisation, corrosion, crystallisation) unidirectional bidirectional Design cc = concentric ec = eccentric ATEX NEC Page = = = X = FA-E 25-300 1" - 12" straight through, ec IIA, IIB3, IIC D, C, B ATEX X 90-95 FA-CN 25-300 1" - 12" straight through, cc IIA, IIB3 D, C ATEX X 96-99 FA-CN 40-300 1½" - 12" straight through, cc IIC B ATEX X 100-102 FA-G G ½" - G 2" straight through, cc IIA, IIB3, IIC D, C, B ATEX X 104-107 FA-I 50-1000 2" - 40" straight through, cc IIA, IIB3 D, C ATEX X 108-111 All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 88

Notes: 89

In-Line Deflagration Flame Arrester eccentric design, bidirectional PROTEGO FA-E d dismantling dimension for servicing (temperature sensor) Design with one or two temperature sensors Ø c The standard design can be used up to an operating temperature of +60 C / 140 F and an absolute operating pressure up to 1.1 bar / psi. Devices with special approval can be obtained for higher pressures (see table 3) and higher temperatures upon request. Type-approved according to ATEX Directive 94/9/EC and EN ISO 16852 as well as other international standards. Special Features and Advantages b eccentric design prevents condensate build up special design for elevated operating temperatures and pressures available a modular design enables each individual FLAMEFILTER to be replaced service friendly: FLAMEFILTER can be cleaned easily 1 2 3 Connection to the protected side (only for type FA-E-T-...) Function and Description eccentric design eases installation close to fl oors and walls bidirectional fl ame transmission proof design protects against defl agrations for all explosion groups IIA, IIB3 and IIC (NEC groups D, C and B) modular design reduces spare parts cost The PROTEGO FA-E series of in-line defl agration fl ame arresters is designed with an eccentric housing to automatically drain condensate build up in the housing. Due to its eccentric design the device can be installed in pipelines that run close to fl oors or walls and low points, where condensate can collect within the piping system, can be avoided. When installing the deflagration fl ame arrester, make sure that the distance between potential ignition sources and the location of the installed device, does not exceed the L/D ratio (pipe length/pipe diameter), for which the device was approved. According to EN ISO 16852 the installation limits are (L/D)max 50 for defl agration fl ame arresters of explosion groups IIA and IIB3 (NEC groups D to C) and (L/D)max 30 for explosion group IIC (NEC group B). The devices are symmetrical and offer bidirectional fl ame transmission protection. The arrester essentially consists of two housing parts (1) and a PROTEGO fl ame arrester unit (2) in the center. The PROTEGO fl ame arrester unit is modular and consists of several FLAMEFILTER discs (3) and spacers fi rmly held in a FLAMEFILTER cage. The number of FLAMEFILTER and their gap size depends arrester s conditions of use. By indicating the operating parameters such as temperature, pressure, explosion group and the composition of the fl uid, the optimum defl agration fl ame arrester can be selected from a series of approved devices. The PROTEGO FA-E series of deflagration fl ame arresters is available for substances from explosion groups IIA to IIC (NEC groups D to B). Design and Specifications There are three different designs: Basic in-line defl agration fl ame arrester In-line deflagration fl ame arrester with integrated temperature sensor* as additional protection against short-time burning from one side In-line deflagration fl ame arrester with two integrated temperature sensors* for additional protection against short-time burning from both sides Additional special devices available upon request *Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2) FA-E - FA-E - T FA-E - TB All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 90

Table 1: Dimensions To select the nominal size (), use the fl ow capacity charts on the following pages Expl. Gr. IIA IIB3 IIC a a a b c d 25 / 1" 304 / 11.97 304 / 11.97 304 / 11.97 29 / 1.14 185 / 7.28 400 / 15.75 32 / 1¼" 304 / 11.97 304 / 11.97 304 / 11.97 29 / 1.14 185 / 7.28 400 / 15.75 40 / 1½" 310 / 12.20 310 / 12.20 321 / 12.64 29 / 1.14 210 / 8.27 410 / 16.14 50 / 2" 314 / 12.36 314 / 12.36 325 / 12.80 29 / 1.14 210 / 8.27 410 / 16.14 65 / 2½" 360 / 14.17 360 / 14.17 371 / 14.61 38 / 1.49 250 / 9.84 440 / 17.32 80 / 3" 364 / 14,33 364 / 14,33 375 / 14.76 38 / 1.49 250 / 9.84 440 / 17.32 100 / 4" 370 / 14.57 370 / 14.57 381 / 15.00 39 / 1.53 275 / 10.83 460 / 18.11 125 / 5" 434 / 17.09 434 / 17.09 445 / 17.52 65 / 2.56 385 / 15.16 520 / 20.47 150 / 6" 440 / 17.32 440 / 17.32 451 / 17.76 65 / 2.56 385 / 15.16 520 / 20.47 Dimensions in mm / inches 200 / 8" 450 / 17.72 450 / 17.72 461 / 18.15 55 / 2.17 450 / 17.72 540 / 21.26 250 / 10" 480 / 18.90 480 / 18.90 491 / 19.33 58 / 2.28 500 / 19.69 570 / 22.44 300 / 12" 500 / 19.69 500 / 19.69 511 / 20.12 60 / 2.36 575 / 22.64 600 / 23.62 Table 2: Selection of the explosion group MESG Expl. Gr. (IEC/CEN) Gas Group (NEC) > 0.90 mm IIA D 0.65 mm IIB3 C < 0.50 mm (> 0.50 mm) IIC (IIB) B Special approvals upon request Table 3: Selection of max. operating pressure Expl. Gr. 25 / 1" IIA P max IIB3 P max IIC P max 32 / 1¼" 40 / 1½" 50 / 2" 65 / 2½" 80 / 3" 100 / 4" 125 / 5" 150 / 6" P max = maximum allowable operating pressure in bar / psi absolute, higher operating pressure upon request 200 / 8" 250 / 10" 300 / 12" Table 4: Specification of max. operating temperature 60 C / 140 F higher operating temperatures upon request T60 Tmaximum allowable operating temperature in C Table 5: Material selection for housing Design B C D Housing Steel Stainless Steel Hastelloy Gasket PTFE PTFE PTFE Flame arrester unit A,C C D The housing can also be delivered in carbon steel with an ECTFE coating. Special materials upon request 91

In-Line Deflagration Flame Arrester eccentric design, bidirectional PROTEGO FA-E Table 6: Material combinations of the flame arrester unit Design A C D *the FLAMEFILTER is also available in the materials FLAMEFILTER cage Steel Stainless Steel Hastelloy Tantalum, Inconel, Copper, etc. when the FLAMEFILTER * Stainless Steel Stainless Steel Hastelloy listed housing and cage materials are used. Spacers Stainless Steel Stainless Steel Hastelloy Special materials upon request. Table 7: Flange connection type EN 1092-1, Form B1 or DIN 2501, Form C, PN 16; from 200 PN 10 ANSI 150 lbs RFSF EN or DIN ANSI other types upon request All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 92

In-Line Deflagration Flame arrester Flow Capacity Charts PROTEGO FA-E airfl ow in thousands of CFH pressure drop p (mbar) pressure drop p (mbar) FA-E-IIA-P1.2 flow rate V. (m³/h) 2671-L airfl ow in thousands of CFH FA-E-IIA-P1.6 pressure drop p inch W.C. pressure drop p inch W.C. fl ow rate V. (m³/h) 2672-L The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. 93

In-Line Deflagration Flame Arrester Flow Capacity Charts PROTEGO FA-E airflow in thousands of CFH pressure drop p (mbar) FA-E-IIB3-P1.1 pressure drop p inch W.C. fl ow rate V. (m³/h) 2845-L airfl ow in thousands of CFH pressure drop p (mbar) FA-E-IIB3-P1.6 pressure drop p inch W.C. fl ow rate V. (m³/h) 2673-L The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 94

* P1.2 * airfl ow in thousands of CFH pressure drop p (mbar) FA-E-IIC-P1.1 pressure drop p inch W.C. fl ow rate V. (m³/h) 2855-L 95

In-Line Deflagration Flame Arrester concentric design, bidirectional PROTEGO FA-CN-IIA and IIB3 1 2 3 4 b a The standard design can be used up to an operating temperature of +60 C / 140 F and an absolute operating pressure up to 1.1 bar / psi. Devices with special approval can be obtained for higher pressures (see table 3) and higher temperatures upon request. Ø d Type-approved according to ATEX Directive 94/9/EC and EN ISO 16852 as well as other international standards. Connection to the protected side (only for type FA-CN-T-...) Function and Description Design with one or two temperature sensors each temperature sensor turned by 90 on the drawing The PROTEGO FA-CN in-line defl agration fl ame arrester is a compact design utilizing an easy access cover for easy maintainability. The PROTEGO fl ame arrester unit can be removed and cleaned within moments without having to disassemble the pipe. When installing the defl agration fl ame arrester, make sure that the distance between potential ignition sources and the location of the installed device, does not exceed the L/D ratio (pipe length/pipe diameter), for which the device was tested. According to EN ISO 16852 this device is approved for a (L/D)max ratio of 50. The defl agration fl ame arrester is symmetrical and offers bidirectional fl ame transmission protection. The device consists of a housing (1) with an easy access cover (3) and the PROTEGO fl ame arrester unit (2) in the center. The PROTEGO fl ame arrester unit is modular and consists of several FLAMEFILTER discs (3) and spacers fi rmly held in a FLAMEFILTER cage. The number of FLAMEFILTER discs and their gap size depend on the devices intended use. Providing the operating conditions such as the temperature, pressure, explosion group and the composition of the fl uid, enables PROTEGO to select the best defl agration fl ame arrester for your application. This version of PROTEGO FA-CN-IIA and IIB3 fl ame arrester protects against defl agrations of fuel/air mixtures of explosion groups IIA and IIB 3 (NEC D and C (MESG 0.65 mm)). PROTEGO FA-CN devices for substances of explosion groups IIA1 and IIC (NEC group B) are shown on separate pages. c Special Features and Advantages design available for elevated operating temperatures and pressures compact design with easy access cover easy maintenance without disassembling of the pipeline modular fl ame arrester unit enables individual FLAMEFILTER to be replaced and cleaned bidirectional fl ame transmission proof design provides protection against defl agrations for group IIA and IIB3 vapours (NEC group D and C) lowest pressure drop results in low operating and lifecycle costs modular design reduces spare parts cost Design and Specifications There are three different designs: Basic in-line defl agration fl ame arrester In-line deflagration fl ame arrester with integrated temperature sensor* as additional protection against short time burning from one side In-line deflagration fl ame arrester with two integrated temperature sensors* for additional protection against short-time burning from both sides Additional special devices available upon request *Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2) FA-CN - FA-CN - T FA-CN - TB All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 96

Table 1: Dimensions To select the nominal size (), use the fl ow capacity charts on the following pages a b c d 25 / 1" 200 / 7.87 92 / 3.62 175 / 6.89 105 / 4.13 32 / 1¼" 200 / 7.87 92 / 3.62 175 / 6.89 105 / 4.13 40 / 1½" 210 / 8.27 105 / 4.13 200 / 7.87 130 / 5.12 50 / 2" 215 / 8.46 105 / 4.13 200 / 7.87 130 / 5.12 65 / 2½" 235 / 9.25 132 / 5.2 260 / 10.24 185 / 7.28 80 / 3" 240 / 9.45 132 / 5.2 260 / 10.24 185 / 7.28 100 / 4" 265 / 10.43 150 / 5.91 308 / 12.13 220 / 8.66 125 / 5" 305 / 12.01 197 / 7.75 415 / 16.34 310 / 12.20 150 / 6" 310 / 12.20 197 / 7.75 415 / 16.34 310 / 12.20 Dimensions in mm / inches 200 / 8" 300 / 11.81 220 / 8.66 446 / 17.56 355 / 13.98 250 / 10" 320 / 12.60 260 / 10.24 520 / 20.47 420 / 16.54 300 / 12" 350 / 13.78 295 / 11.61 600 / 23.62 490 / 19.29 Table 2: Selection of the explosion group MESG Expl. Gr. (IEC/CEN) Gas Group (NEC) > 0.90 mm IIA D 0.65 mm IIB3 C Special approvals upon request Table 3: Selection of max. operating pressure Expl. Gr. 25 / 1" IIA P max IIB3 P max 32 / 1¼" 40 / 1½" 50 / 2" 65 / 2½" P max = maximum allowable operating pressure in bar / psi absolute, higher operating pressure upon request n = number of FLAMEFILTER 80 / 3" 100 / 4" 1.5 / 21.8 125 / 5" 1.5 / 21.8 150 / 6" 1.5 / 21.8 200 / 8" 1.3 / 18.9 250 / 10" 1.3 / 18.9 300 / 12" 1.3 / 18.9 n 3 3 Table 4: Specification of max. operating temperature 60 C / 140 F higher operating temperatures upon request T60 Tmaximum allowable operating temperature in C Table 5: Material selection Design A B Housing Steel Stainless Steel Cover Steel Stainless Steel Gasket PTFE PTFE Flame arrester unit Stainless Steel Stainless Steel Special materials upon request Table 6: Flange connection type EN 1092-1, Form B1 or DIN 2501, Form C, PN 16; from 200 PN 10 ANSI 150 lbs RFSF EN or DIN ANSI other types upon request 97

In-Line Deflagration Flame Arrester Flow Capacity Charts PROTEGO FA-CN-IIA and IIB3 airfl ow in thousands of CFH pressure drop p (mbar) FA-CN-IIA-P1.2 2-fold FLAMEFILTER pressure drop p inch W.C. fl ow rate V. (m³/h) 1921-L P* see table 3 airfl ow in thousands of CFH pressure drop p (mbar) FA-CN-IIA-P* 3-fold FLAMEFILTER pressure drop p inch W.C. fl ow rate V. (m³/h) 1922-L The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 98

airfl ow in thousands of CFH pressure drop p (mbar) FA-CN-IIB3-P1.1 2-fold FLAMEFILTER pressure drop p inch W.C. fl ow rate V. (m³/h) 2849-L airfl ow in thousands of CFH pressure drop p (mbar) FA-CN-IIB3-P1.6 3-fold FLAMEFILTER pressure drop p inch W.C. fl ow rate V. (m³/h) 1924-L 99

In-Line Deflagration Flame Arrester for hydrogen/air-mixtures, concentric design, bidirectional PROTEGO FA-CN-IIC 1 2 3 4 a fl ame arrester protects against defl agrations of fuel/air mixtures of explosion group IIC (NEC B). FA-CN devices for substances of explosion groups IIA1, IIA and IIB3 (NEC D and C (MESG 0.65 mm) are shown on separate pages. b Ø d The standard design can be used up to an operating temperature of +60 C / 140 F and an absolute operating pressure up to 1.1 bar / psi. Type-approved according to ATEX Directive 94/9/EC and EN ISO 16852 as well as other international standards. c Special Features and Advantages Connection to the protected side (only for type FA-CN-T-...) Function and Description Design with one or two temperature sensors each temperature sensor turned by 90 on the drawing The PROTEGO FA-CN in-line defl agration fl ame arrester is a compact design utilizing an easy access cover for easy maintainability. The special PROTEGO FA-CN-IIC version was developed for hydrogen applications (group IIC vapours NEC group B). The device is designed to have comparetively large gaps, in relation to other fl ame arresters for the same explosion group. This allows to apply it to processes having small fl uid droplets or particles. The PROTEGO fl ame arrester unit can be removed and cleaned within moments without having to disassemble the pipe. When installing the defl agration fl ame arrester, make sure that the distance between potential ignition sources and the location of the installed device, does not exceed the L/D ratio (pipe length/pipe diameter), for which the device was approved (see table 4). The defl agration fl ame arrester is symmetrical and offers bidirectional fl ame transmission protection. The device consists of a housing (1) with an easy access cover (3) and the PROTEGO fl ame arrester unit (2) in the center. The PROTEGO fl ame arrester unit is modular and consists of several FLAMEFILTER discs (3) and spacers fi rmly held in a FLAMEFILTER cage. The number of FLAMEFILTER discs and their gap size depend on the devices intended use. Providing the operating conditions such as the temperature, pressure, explosion group and the composition of the fl uid, enables PROTEGO to select the best defl agration fl ame arrester for your application. The versions of PROTEGO FA-CN-IIC state of the art protection for any hydrogen/air mixture can be applied to process fl ows with small liquid or particle load compact design with easy access cover easy maintenance without disassembling of the pipeline modular fl ame arrester unit enables individual FLAMEFILTER to be replaced and cleaned bidirectional fl ame transmission proof design protects against defl agrations for all explosion groups lowest pressure drop results in low operating and lifecycle costs modular design reduces spare parts cost Design and Specifications There are three different designs: Basic in-line defl agration fl ame arrester In-line deflagration fl ame arrester with integrated temperature sensor* as additional protection against short time burning from one side In-line deflagration fl ame arrester with two integrated temperature sensors* for additional protection against short-time burning from both sides Additional special devices available upon request *Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2) FA-CN - FA-CN - T FA-CN - TB All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 100

Table 1: Dimensions To select the nominal size (), use the fl ow capacity charts on the following pages a b c d 40 / 1½" 210 / 8.27 105 / 4.13 200 / 7.87 130 / 5.12 50 / 2" 215 / 8.46 105 / 4.13 200 / 7.87 130 / 5.12 65 / 2½" 235 / 9.25 132 / 5.2 260 / 10.24 185 / 7.28 80 / 3" 240 / 9.45 132 / 5.2 260 / 10.24 185 / 7.28 100 / 4" 265 / 10.43 150 / 5.91 308 / 12.13 220 / 8.66 125 / 5" 305 / 12.01 197/ 7.75 415 / 16.34 310 / 12.20 150 / 6" 310 / 12.20 197 / 7.75 415 / 16.34 310 / 12.20 200 / 8" 300 / 11.81 220 / 8.66 446 / 17.56 355 / 13.98 Dimensions in mm / inches 250 / 10" 320 / 12.60 260 / 10.24 520 / 20.47 420 / 16.54 300 / 12" 350 / 13.78 295 / 11.61 600 / 23.62 490 / 19.29 Table 2: Selection of the explosion group MESG Expl. Gr. (IEC/CEN) Gas Group (NEC) < 0.50 mm IIC B Special approvals upon request Table 3: Selection of max. operation pressure 40 / 1½" P max 50 / 2" 65 / 2½" 80 / 3" 100 / 4" 125 / 5" 150 / 6" 200 / 8" 250 / 10" 300 / 12" P max = maximum allowable operating pressure in bar / psi absolute, higher operating pressure upon request Table 4: Max. allowable L/D-ratio 40 / 1½" 50 / 2" 65 / 2½" 80 / 3" 100 / 4" 125 / 5" 150 / 6" 200 / 8" 250 / 10" 300 / 12" (L/D) max 30 30 10 10 10 20 20 10 10 5 Designation X12 X12 X12 X10 X10 X12 X12 X13 Table 5: Material selection Design A B Housing Steel Stainless Steel Cover Steel Stainless Steel Gasket PTFE PTFE Flame arrester unit Stainless Steel Stainless Steel Special materials upon request Table 6: Flange connection type EN 1092-1, Form B1 or DIN 2501, Form C, PN 16; from 200 PN 10 ANSI 150 lbs RFSF EN or DIN ANSI other types upon request 101

In-Line Deflagration Flame Arrester Flow Capacity Chart PROTEGO FA-CN-IIC X see table 4 airfl ow in thousands of CFH pressure drop p (mbar) FA-CN-IIC-P1.1-X pressure drop p inch W.C. fl ow rate V. (m³/h) 2038-L The fl ow capacity chart has been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. All rights and alterations reserved acc. ISO 16016 102 - Active data sheet at www.protego.de

Notes: 103

In-Line Deflagration Flame Arrester concentric design, bidirectional PROTEGO FA-G Design with one or two temperature sensors SW 1 2 Ø b Ø a d dismantling dimension for servicing (temperature sensor) termined by the operating data and parameters of the mixture fl owing in the line (explosion group, pressure, temperature). The PROTEGO FA-G series in-line defl agration fl ame arresters is available for explosion groups IIA, IIB3 and IIC (NEC groups D, C (MESG 0.65 mm) and B). The standard design can be used up to an operating temperature of +60 C / 140 F and an absolute operating pressure acc. to table 3. Devices with special approval can be obtained for higher pressures and higher temperatures upon request. Type-approved according to ATEX Directive 94/9/EC and EN ISO 16852 as well as other international standards. Special Features and Advantages different application possibilities modular design the individual FLAMEFILTER can be quickly removed and installed threaded connection for direct mounting into pipeline bidirectional fl ame transmission proof design protects against defl agrations for all explosion groups c Connection to the protected side (only for type FA-G-T-...) use of temperature sensors for G 1½" and 2" is possible cost effi cient spare parts Function and Description Design and Specifications The compact design of the PROTEGO FA-G in-line defl agration fl ame arrester makes it the state of the art technology for installation in pipes with diameters of up to 2. The devices are installed with minimal distance to the burner to prevent fl ashback in to the fuel feed lines. When installing the deflagration fl ame arrester, make sure that the distance between potential ignition sources and the location of the installed device, does not exceed the L/D ratio (pipe length/pipe diameter), for which the device was approved. As per EN ISO 16852 the L/D ratio is limited to (L/D) max 50 for defl agration fl ame arresters of explosion groups IIA and IIB3 (NEC groups D and C (MESG 0.65 mm)) and to (L/D) max 30 for explosion group IIC (NEC group B). The in-line defl agration fl ame arrester is symmetrical and offers bidirectional fl ame transmission protection. The device consists of two housing parts (1) and a PROTEGO fl ame arrester unit or a FLAMEFILTER (2) and spacers in the center. The number of FLAMEFILTER discs and their gap size are de- There are three different designs: Basic in-line defl agration fl ame arrester (G ½" to 2") In-line defl agration fl ame arrester with integrated temperature sensor* for additional protection against short-time burning from one side (G 1½" to 2") In-line defl agration fl ame arrester with two integrated temperature sensors* for additional protection against short-time burning from both sides (G 1½" to 2") *Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2) FA-G- FA-G- T FA-G- TB Flange connection available upon request All rights and alterations reserved acc. ISO 16016 104 - Active data sheet at www.protego.de

Table 1: Dimensions Dimensions in mm / inches, SW = width across fl ats To select the nominal size (), use the fl ow capacity charts on the following pages G ½" G ¾" G 1" G 1 ¼" G 1 ½" G 2" a 80 / 3.15 80 / 3.15 100 / 3.94 100 / 3.94 155 / 6.10 155 / 6.10 b 55 / 2.17 55 / 2.17 76 / 2.99 76 / 2.99 124 / 4.88 124 / 4.88 c (IIA up to IIB3) 100 / 3.94 100 / 3.94 110 / 4.33 110 / 4.33 170 / 6.69 170 / 6.69 c (IIB and IIC) 112 / 4.41 112 / 4.41 122 / 4.80 122 / 4.80 170 / 6.69 170 / 6.69 d 400 / 15.75 400 / 15.75 SW 32 / 1.26 32 / 1.26 50 / 1.97 50 / 1.97 75 / 2.95 75 / 2.95 Table 2: Selection of the explosion group MESG Expl. Gr. (IEC/CEN) Gas Group (NEC) > 0.90 mm IIA D 0.65 mm IIB3 C < 0.50 mm IIC B Special approvals upon request Table 3: Selection of max. operating pressure G ½" G ¾" G 1" G 1 ¼" G 1 ½" G 2" Expl. Gr. IIA P max 1.4/20.3 1.4/20.3 1.4/20.3 1.4/20.3 1.5/21.7 1.5/21.7 IIB3 P max 1.2/ 1.2/ 1.2/ 1.2/ 1.2/ 1.2/ IIC P max 1.1/ 1.1/ 1.1/ 1.1/ 1.1/ 1.1/ P max = maximum allowable operating pressure in bar / psi absolute, higher operating pressure upon request Table 4: Specification of max. operating temperature 60 C / 140 F higher operating temperatures upon request T60 Tmaximum allowable operating temperature in C Table 5: Material selection Design A B C Housing Steel Stainless Steel Hastelloy Gasket PTFE PTFE PTFE FLAMEFILTER * Stainless Steel Stainless Steel Hastelloy Special materials upon request. * the FLAMEFILTER is also available in the materials Tantalum, Inconel, Copper, etc. when the listed housing materials are used. Table 6: Type of connection Pipe thread DIN ISO 228-1 DIN other types of thread upon request 105

In-Line Deflagration Flame Arrester Flow Capacity Charts PROTEGO FA-G-IIA, IIB3 and IIC P* see table 3 airfl ow in thousands of CFH pressure drop p (mbar) FA-G-IIA-P* pressure drop p inch W.C. fl ow rate V. (m³/h) 1828-L airfl ow in thousands of CFH pressure drop p (mbar) FA-G-IIB3-P1.2 pressure drop p inch W.C. fl ow rate V. (m³/h) 1829-L The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 106

airfl ow in thousands of CFH pressure drop p (mbar) FA-G-IIC-P1.1 pressure drop p inch W.C. fl ow rate V. (m³/h) 1699-L 107

In-Line Deflagration Flame Arrester concentric design, bidirectional PROTEGO FA-I Design with one or two temperature sensors NG Ø a c dismantling dimension for servicing (temperature sensor) The standard design can be used up to an operating temperature of +60 C/ 140 F and an absolute operating pressure up to 1.1 bar / psi. Devices with special approvals can be obtained for higher pressures (see table 3) and higher temperatures upon request. Type-approved according to ATEX Directive 94/9/EC and EN ISO 16852 as well as other international standards. Special Features and Advantages optimized fl ow capacity different series allow increase of FLAMEFILTER size for given flange connection resulting in lower pressure drop across the device 1 2 3 b Connection to the protected side (only for type FA-I-T-...) Function and Description In the development of the PROTEGO FA-I in-line defl agration fl ame arrester, special effort was made to optimize the fl uid dynamic flow characteristics. For a given fl ange connection size of the fl ame arrester, the FLAMEFILTER size can be chosen from series 1, 2 and 3 (see table 1) for the most adequate fl ow capacity. When installing the defl agration fl ame arrester, make sure that the distance between potential ignition sources and the location of the installed device, does not exceed the L/D ratio (pipe length/pipe diameter), for which the device was tested (see table 4). The defl agration fl ame arrester is symmetrical and offers bidirectional fl ame transmission protection. The device essentially consists of two housing parts (1) and the PROTEGO fl ame arrester unit (2) in the center. The PROTEGO fl ame arrester unit is modular and consists of several FLAMEFILTER discs (3) and spacers fi rmly held in a FLAMEFILTER cage. The number of FLAMEFILTER discs and their gap size depends on the arrester s conditions of use. Providing the operating conditions such as the temperature, pressure, explosion group and the composition of the fl uid, enables PROTEGO to select the best defl agration fl ame arrester for your application. The PROTEGO FA-I series of defl agration fl ame arresters is available for substances of explosion groups IIA and IIB3 (NEC groups D and C (MESG 0.65 mm)). option for integrated cleaning nozzles can be provided modular fl ame arrester unit enables each individual FLAMEFILTER to be replaced and cleaned bidirectional fl ame transmission proof design protects with defl agrations for explosion groups IIA and IIB3 (NEC groups D and C) design available for elevated operating temperatures and pressures available sizes from 50 / 2 to 1000 / 40 lowest pressure drop results in low operating and lifecycle costs modular design reduces spare parts cost Design and Specifications There are three different designs: Basic defl agration fl ame arrester design In-line deflagration fl ame arrester with integrated temperature sensor* for additional protection against short-time burning from one side In-line deflagration fl ame arrester with two integrated temperature sensors* for additional protection against short-time burning from both sides Additional special devices available upon request *Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2) FA-I- FA-I- T FA-I- TB All rights and alterations reserved acc. ISO 16016 108 - Active data sheet at www.protego.de

Table 1: Dimensions To select nominal width/nominal size (NG/) - combination, please use the fl ow capacity charts on the following pages standard Expl. Gr. NG a IIA b* IIB3 b* c 150 6 50 2" 285 / 11.22 364 / 14.33 364 / 14.33 500 / 19.69 150 6 80 3" 285 / 11.22 364 / 14.33 364 / 14.33 500 / 19.69 200 8 100 4" 340 / 13.39 452 / 17.79 464 / 18.27 520 / 20.47 300 12 150 6" 445 / 17.52 584 / 22.99 596 / 23.46 570 / 22.44 *Dimension b only for P1.2 (IIA) and P1.1 (IIB3). 400 16 200 8" 565 / 22.24 638 / 25.12 650 / 25.59 620 / 24.41 Dimensions in mm / inches Additional nominal width/nominal size (NG/) - combinations for improved fl ow capacity upon request 500 20 250 10" 670 / 26.38 688 / 27.09 700 / 27.56 670 / 26.38 600 24 300 12" 780 / 30.71 800 / 31.50 800 / 31.50 700 / 31.50 800 32 400 16" 975 / 38.39 900 / 35.43 900 / 35.43 900 / 35.43 1000 40 500 20" 1175 / 46.26 1000 / 39.37 1000 / 39.37 1000 / 39.37 1200 48 600 24" 1405 / 55.31 1100 / 43.31 1100 / 43.31 1100 / 43.31 1400 56 800 32" 1630 / 64.17 1350 / 53.15 1350 / 53.15 1350 / 53.15 1600 64 800 32" 1830 / 72.05 1450 / 57.09 1450 / 57.09 1450 / 57.09 Table 2: Selection of the explosion group MESG Expl. Gr. (IEC/CEN) Gas Group (NEC) > 0.90 mm IIA D 0.65 mm IIB3 C Special approvals upon request Table 3: Selection of max. operating pressure Expl. Gr. NG 150 6 50 2" 1.8 / IIA P max 26.1 IIB3 P max 150 6 80 3" 1.8 / 26.1 200 8 100 4" 1.5 / 21.7 300 12 150 6" 1.5 / 21.7 400 16 200 8" 1.5 / 21.7 500 20 250 10" 1.5 / 21.7 600 24 300 12" 1.5 / 21.7 800 32 400 16" 1.4 / 20.3 1000 40 500 20" 1.3 / 18.8 P max = maximum allowable operating pressure in bar / psi absolut, higher operating pressure upon request 1200 48 600 24" 1.3 / 18.8 1400 56 800 32" 1600 64 800 32" 109

In-Line Deflagration Flame Arrester concentric design, bidirectional PROTEGO FA-I Table 4: Table 4: Max. allowable L/D-ratio standard NG 150 6 150 6 200 8 300 12 400 16 500 20 600 24 800 32 1000 40 1200 48 1400 56 1600 64 50 2" 80 3" 100 4" 150 6" 200 8" 250 10" 300 12" 400 16" 500 20" 600 24" 800 32" 800 32" (L/D) max 50 50 50 50 50 50 50 50 50 50 50 50 IIA P max 1.3 / 18.8 1.3 / 18.8 - - - - - - - - - - - - (L/D) max 50 50 40 40 35 35 35 30 30 30 25 25 IIB3 P max (bar /psi) Designation Designation - - X6 X6 X7 X7 X7 X8 X8 X8 X9 X9 Table 5: Specification of max. operating temperature 60 C / 140 F higher operating temperatures upon request T60 Tmaximum allowable operating temperature in C Table 6: Material selection for housing Design A B C Housing Steel Stainless Steel Hastelloy Gasket PTFE PTFE PTFE Flame arrester unit A, B C D Special materials upon request. Table 7: Material combinations of the flame arrester unit Design A C D FLAMEFILTER cage Steel Stainless Steel Hastelloy FLAMEFILTER * Stainless Steel Stainless Steel Hastelloy Spacers Stainless Steel Stainless Steel Hastelloy Special materials upon request. The housing can also be delivered in carbon steel with an ECTFE coating. * the FLAMEFILTER is also available in the materials Tantalum, Inconel, Copper, etc. when the listed housing and cage materials are used Table 8: Flange connection type EN 1092-1, Form B1 or DIN 2501, Form C, PN 16; from 200 PN 10 ANSI 150 lbs RFSF EN or DIN ANSI other types upon request All rights and alterations reserved acc. ISO 16016 - Active data sheet at www.protego.de 110

In-Line Deflagration Flame Arrester Flow Capacity Charts PROTEGO FA-I * ** 50/2-400/16 ; P1.2 500/20, 600/24 ; P1.3 * = NG 1400/56" / 800/32"; P1.2 ** = NG 1600/64" / 800/32"; P1.1 NG / airfl ow in thousands of CFH pressure drop p (mbar) pressure drop p (mbar) X see table 4 FA-I-IIA-P fl ow rate V. (m³/h) 1815-L * = NG 1400/56" / 800/32", ** = NG 1600/64" / 800/32" * and ** 4 FLAMEFILTER, therefore the pressure drop is higher airfl ow in thousands of CFH FA-I-IIB3-P1.1-X NG / * ** pressure drop p inch W.C. pressure drop p inch W.C. fl ow rate V. (m³/h) 1817-L The fl ow capacity charts have been determined with a calibrated and TÜV certifi ed fl ow capacity test rig. Volume fl ow V. in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20 C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: Technical Fundamentals. 111

www.protego.de