VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V)

Similar documents
CSO/STORMWATER MANAGEMENT. HYDROVEX VHV / SVHV Vertical Vortex Flow Regulator

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

Lecture 10 : Sewer Appurtenances

HYDROVEX TTT Membrane Flow Regulator

Float operated valve TYPE (SWDS)

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

KTM 50 (DN ) Installation, maintenance and operating instructions

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator

22. Specialty Valves.

Bermad Pressure Reducing. Model: 42T

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Design a grit chamber for population with water consumption of 135 LPCD.

Pressure Reducing Valve for Steam Type 2333 A

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

RESIDENTIAL REGULATORS

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Module 15 : Grit Chamber. Lecture 20 : Grit Chamber

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

TECHNICAL DATA Q= C. Table 1 - Specifications

Integral type Differential pressure flowmeter VNT Series

Installation, operation & maintenance manual - original version

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Combination Air Valve

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Vertical Bladder Tanks

TECHNICAL DATA. Q = C v P S

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

HORIZONTAL BLADDER TANK

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Self-operated Pressure Regulators for special applications

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

DESIGN AND PRE - INSTALLATION INFORMATION

Horizontal Bladder Tanks

Model: 43T. Bermad Pressure Relief Valve

VERTICAL BLADDER TANK

safety shut-off Valve HON 703 / HON 704

Model MTB-ASME Horizontal Bladder Tanks

WE SAY: REFILL PLEASE!

TECHNICAL DATA. Q= Cv S

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

Pressure Reducing Valve DMV 755

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Pressure relief valve DHV 725 set range: 0,2-10,0 bar


HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Combination Air Valve Model

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Pressure Independent Control Series

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

200 / 300 Upgrade Kits

BACK PRESSURE / SUSTAINING

Dual position solenoid valve Type ICSH 25-80

BACK PRESSURE / SUSTAINING

Pressure and Flow Control Valves DBGM, German and European Patents

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

DN300 DN2000 C Plunger Valve

Gas Pressure Regulator HON 200

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Classic wine storage tanks model EXX

USE AND MAINTENANCE LIGHT TOWER

my SYSTEM A guide to common applications in water distribution systems

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

SV60 Safety valves. for use with steam, gas and liquids

PRESSURE REDUCING VALVE RP45 (EN)

Free Surface Flow Simulation with ACUSIM in the Water Industry

TECHNICAL DATA. Q = C v P S

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

CLASS TLP Pressure Reducing Valve

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

Pressure Reducing Valve DMV 750 set range: bar

TECHNICAL DATA. Q = C v P S

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Air Eliminators and Combination Air Eliminators Strainers

2-port and 3-port valves PN 16

Biodec Decanter. Ideal with our CYCLATOR technology

CAST IRON VALVES FLOAT VALVE

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.

Sapag Control valve MONOVAR

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

SINGLE VALVE WITH LOW-FLOW BYPASS

SIHI LPH-X - Liquid Ring Compressors

Remeha Quinta Cascade guide

Armatures for analytical probes

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

Transcription:

VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V) UCY series, CY series, CE/V series, OP series Conical vortex regulator Type WAB-UCY (wet installation) Vertical vortex regulator Type WAB- CE/V (wet installation) Semi-dry vortex regulation Type WAB-CY- F (semi-dry installation) Vortex Regulator Type WAB Product description Rev. 0 Page 1 of 15

Table of Contends Flow regulator overview 3 Product Specifications 4 Wet Installation 4 Type WAB-UCY 4 Operational description 4 Design flow 5 Installation 5 Type WAB-CE/V 6 Operational description 6 Installation 6 Emergency draining for retention systems 7 Installation in circular chambers 7 Type SZ integrated bypass facility (spindle lifting system) 8 Adapter with integrated emergency bypass facility Type ADAPT- NE 9 Adapter with integrated bypass facility and emergency overflow TYPE ADAPT-NE-NÜ Integrated gate valve Type INT-FS 11 Semi Dry Installation 12 Type CY-F 12 Operational description 12 Discharge opening / wall opening / outgoing pipes 13 Installation 13 Advantages of the Vortex regulator 15 10 Vortex Regulator Type WAB Product description Rev. 0 Page 2 of 15

Flow regulator overview Flow regulators have the task of restricting the pass forward flow during storm conditions and are used to regulate the flow from storm water retention tanks, sewers, retention tanks or overflow chambers to a preset value independent of the head, whilst allowing a constant flow. Some retention bassins do have little requirements on the throttle accuracy but require a complete open coss-section without moving parts for little blockage risk. Cyclon vortex throttles do have a big market acceptance because of these advantages and it's simple construction. The applications for robust vortex throttles are manifold and there exist a very long experience with these throttles. Vortex throttle with integrated bypass system. Vortex Regulator Type WAB Product description Rev. 0 Page 3 of 15

Product Specifications A stainless steel Vortex Flow Control consists out of a cyclone like body suited with a specific inlet and outlet. It can be installed wet and semidry. Detailed specifications and constructional details of the mentioned Flow Controls can also be demanded by info@biogest.com Optionally the Flow Control can be fitted with an integrated bypass system. This system will assure a full bypass of the wastewater in the case of blockage in the Flow Control. This bypass system can be operated by means of a manual pulling cord which is to be fitted just below the manhole. Wet Installation Typ WAB-UCY The Vortex flow regulator Type UCY is a wet installed unit. Therefore, in contrast to semi-dry installations, there is no need of a separate throttle manhole needed. However, in order to be able to empty the manhole in the event of an accident, a separate emergency drain should be forseen. The Vortex flow regulator consists of an inlet, a conical vortex chamber and an outlet, which can be fixed on a concrete wall or put into concrete in an opening. Operational description A predefined regulation flow rate, will be throttled by means of a vortex principle. The wet installed unit is mounted in front of an outlet opening of a storage system. The Vortex flow regulator consists of a robust stainless steel construction with no moving parts. The water flows tangentially into the throttle. At low flows the flow control presents practically no resistance to the water flow. As the water flow increases, tangential velocity within the flow control increases and eventually lead to the formation of an air-filled vortex core. This vortex has a breaking effect without physically obstructing the flow opening and therefore guarantees a predefined maximum capacity. The vortex flow regulator is also available with an adjustable u-shaped inlet area. This allows reducing the flow subsequently. Vortex Regulator Type WAB Product description Rev. 0 Page 4 of 15

Design flow The nominal sizes of the flow limiter are selected according to the required design flow value and the water head. Due to the free flow with the vortex principle, the maximum throttle rate will be achieved at the upper end of the water head. Flow curve Installation The Vortex flow regulator Type WAB-UCY will be fixed doweled with a mounting plate on an outlet wall. Optional the unit can be concreted into the wall. The profiled concrete has to be placed after installation. Vortex Regulator Type WAB Product description Rev. 0 Page 5 of 15

Type WAB-CE/V The Vertical vortex regulator Type CE/V is a wet installed unit. Therefore, in contrast to semi-dry installations, there is no need of a separate throttle manhole needed. However, in order to be able to empty the manhole in the event of an accident, a separate emergency drain (integrated or separately) should be foreseen. The Vortex flow regulator consists of a vertical conical vortex body and is particularly suitable for the limitation of rainwater. This vortex body is placed on a plug-in board, which will be doweled on a wall. With a pull rod, the device can be pulled up to remove any blockages. Operational description A predefined regulation flow rate, will be throttled by means of a vortex principle. The wet installed unit is mounted in front of an outlet opening of a storage system. The inlet of the vertical vortex regulator is tangential in flow direction. The outlet is in flow direction at the back of the unit. Because the outlet is located higher than the inlet, the inlet is normally submerged. This leads to a permanent damming at the inlet. In a storm event and rising water level, the air escapes from a small hole at the apex of the vertical vortex body. As soon as the water level reached the peak the vortex flow starts. This vortex has a breaking effect without physically obstructing the flow opening and therefore guarantees a predefined maximum capacity. Installation The Vortex flow regulator TYP CE-V consist on two pieces. The plug-in board will be doweled on the outlet opening. Then the vortex unit must be inserted into the plug-in board. Below the unit, a bottom step of at least 1x the size of the outlet opening must be present. Vortex Regulator Type WAB Product description Rev. 0 Page 6 of 15

Emergency draining for retention systems In accordance with ATV Standard A 166, a higher emergency bypass pipe with a minimum diameter of DN 200 is to be provided parallel to each flow regulation device, through which the wastewater can be drained by gravity in the event of a blockage. Although the Vortex flow regulator type WAB has an inspection opening to remove blockages, in extreme cases a large blockage of the regulator can occur, which make it unpossible to enter the manhole. In cases such as these, the upstream sewer network including the storage chambers may have to be pumped out, unless an inlet penstock or a bypass arrangement is installed. For this reason, we always recommend the installation of an emergency draining facility. BIOGEST supplies several emergency drainage options for use with our regulating devices: a) For the simplest arrangement, we recommend the BIOGEST gate valve, which can be bolted by the side of the Vortex flow regulator to provide an emergency bypass. b) If it is not possible to use a gate valve for space reasons, e.g. structure too narrow or a bypass pipe cannot be laid (e.g. in case of retrofitting), it is possible to use an integrated emergency draining facility, TYPE SZ or the adapter with an integrated emergency draining facility, TYPE ADAPT-NE. Further details of these two options are detailed in the following chapter, optional components NOTE: The slide valves of flow restrictor devices and bypass pipes in wet and semi-dry structures are to be equipped with slide rods or spindle extensions in accordance with ATV Standard A 166 for safety reasons, so that they can be operated without entering the structures or tanks. Installation in circular chambers The Wirbelabflussbegrenzer Typ WAB-UCY and WAB-CE/V in wet installation can be installed in suitably dimensioned circular chambers. A flat and vertical installation surface (concrete surface) is required for the ALPHEUS unit to be fixed correctly. If a flat and vertical installation surface is not available, BIOGEST can supply an adapter, which balances out the radius of the shaft (see bellow optional components). Vortex Regulator Type WAB Product description Rev. 0 Page 7 of 15

TYPE SZ integrated bypass facility (spindle lifting system) With the "SZ" device, the complete Vortex flow regulator can be lifted up with the help of the spindle. Any coarse materials causing a blockage in front of the discharge opening are then punched through the larger cross-sectional area of the outlet, so that the chamber can be drained. Any remaining coarse material can then be removed from the tank so that the Vortex regulator can be replaced in its working position. Use of the spndle lifting system type "SZ" is dependent on the geometry of the storm water tank. Where new storage systems are to be built, the facility can be easily accommodated within the design and realised at a low cost and minimal effort. Where a retro fit is required due consideration must be given to the ease and practicality of installing the lifting device. Vortex Regulator Type WAB Product description Rev. 0 Page 8 of 15

Adapter with integrated emergency bypass facility TYPE ADAPT-NE Many chambers often only have one discharge outlet. To realize the emergency bypass facility required to meet standards such as ATV Standard A166 a separate bypass system must be installed at great expense due to the additional pipe work required to return the flow form the bypass back into the continuation flow. The integrated adapter provides an emergency bypass facility in an easier and more cost effective method. Vortex Regulator Type WAB Product description Rev. 0 Page 9 of 15

Adapter with integrated bypass facility and emergency overflow TYPE ADAPT-NE- NÜ This adapter provides three additional functions, it is a very compact system, and is available for installation in a rectangular or circular chambers. Function 1: Function 2: Function 3: Squares the radius Time-consuming construction of a concrete installation surface is eliminated. Emergency bypass facility This allows an emergency bypass facility that does not require any additional holes to be cut into the chamber. Emergency overflow Removes the need to construct an overflow form the bypass back to the continuation flow sewer. Vortex Regulator Type WAB Product description Rev. 0 Page 10 of 15

Integrated gate valve TYPE INT-FS According to the ATV Standard A 166, all storm water tanks should have a flow restricting gate valve regardless of the type of flow restrictor used. The gate valve is required for the trial run, for tests according to the EKVO (control regulation of operators), for maintenance and repair work to the sewer network and for using the retention tank as an emergency storage tank. Vortex Regulator Type WAB Product description Rev. 0 Page 11 of 15

Semi-Dry Installation Type WAB-CY-F The Vortex flow regulator Type CY-F will be installed semi-dry. Therfore a separate dry chamber is needed. The Vortex flow regulator Type CY-F consist of an inlet with flange connection, a conical vortex chamber and a free outlet opening. Operational description The operation of the Vortex flow regulator Type WAB-CY-F in semid-driy installation is halbtrockener Aufstellung ist analog to the operationof the Vortex flow regulator Type WAB-UCY in wet installation. The Vortex flow regulator consists of a robust stainless steel construction with no moving parts. The water flows tangentially into the throttle. At low flows the flow control presents practically no resistance to the water flow. As the water flow increases, tangential velocity within the flow control increases and eventually lead to the formation of an air-filled vortex core. This vortex has a breaking effect without physically obstructing the flow opening and therefore guarantees a predefined maximum capacity. Vortex Regulator Type WAB Product description Rev. 0 Page 12 of 15

Discharge opening / wall opening / outgoing pipes The diameter of the outlet opening / outlet pipe must be big enough, that the throttle flow can be handled. Otherwise, a backflow of water can dirten the manhole. Installation The installation of the semi-dry Vortex flow regulator Type WAB-CY-F will be with a flange connection. The connection to the wall with be with a wall connection piece, which exists in three arrangements. The profiled concrete has to be placed after installation. Vortex Regulator Type WAB Product description Rev. 0 Page 13 of 15

Anschlußstück Typ 1 zum Einbetonieren mit Losflansch PN10 und Mauerkragen Anschlußstück Typ 2 mit Flansch zum Andübeln und Losflansch PN10 Anschlußstück Typ 3 Schieber zum Zwischenflanschen mit Spindelverlängerung Gerät mit Flanschanschluß Vortex flow regulator Type WAB- CY-F for semi-dry installation incl. accessories. Anschlußstück Typ 1 zum Einbetonieren mit Losflansch PN10 und Mauerkragen Anschlußstück Typ 2 mit Flansch zum Andübeln und Losflansch PN10 Schieber zum Zwischenflanschen mit Spindelverlängerung Verlängerungsrohr mit Losflansch PN10 und Bogen 45 Emergency by-pass for semi-dry installation incl. accessories. Vortex Regulator Type WAB Product description Rev. 0 Page 14 of 15

Advantages of the Vortex regulator Regulation without moving parts No wear parts Operates without any external power Robust and simple stainless steel construction Simple and easy installation Minimum maintenance needed. BIOGEST AG Siemensstraße 1 65232 Taunusstein Tel.: +49 (0) 6128 / 97 58-0 Fax: +49 (0) 6128 / 97 58-58 info@biogest.com www.biogest.com Vortex Regulator Type WAB Product description Rev. 0 Page 15 of 15