HIGH VOLTAGE FUSE LINKS

Similar documents
OBSOLETE DESIGN DATA. CONCENTRATE CONTROLLERS 2, 3", 4", 6" and 8" (50, 80, 100, 150, and 200 mm)

What a Wonderful World

Gauge Adapters. Senior 2 1 2" [63,5] Bolt Circle Adapt ers. 22 Series ISO 9001:2008 CERTIFIED. Low pressure applications. The Measure of Excellence

To the Field of Stars

Act I. 2. 'Tis the morning of the fair (Chorus, Allan a Dale, Little John, Will Scarlet, Annabel) Allegro. marc. 4 village musicians enter

Call To Action. & bb b b b. w w. œ œ œ J. &b b b b b. œ œ œ. œ œ. œ œ œ. ? b b b b b 4. j œ. j œ Ó n. œ j. œ j œ œ Ó Œ. œ j Ó Œ j œœ œ Ó.

BODY HARDWARE MASTER METAL DRAWER ASSORTMENTS

Cantabella. Editiert von André Werder. Arranged by KIRBY SHAW. For SATB and Piano with Optional Instrumental Accompaniment Duration: ca.

DEVELOPING AND IMPLEMENTING ENERGY AWARENESS SERVICES

Section 9 COYOTE Closures & Splice Cases for OPGW & ADSS

SKH 1093 RH Calibration Kit for SKH 2000 probes

Phone: Fax: Web:

X2 Metallized Polypropylene Film Capacitor JFV

Offshore Survival Introduction (OSI)

LUMBOSACRAL TRANSITIONAL ANATOMY TYPES AND DISC DEGENERATIVE CHANGES

X2 Metallized Polypropylene Film Capacitor JFV

MEDIUM VOLTAGE DIN Fuse-Links

CyRide Presentation October 2, 2017

MODEL HP-1+6+S HP-S-DIFF-TB TECHNICAL BULLETIN "HIGH" PRESSURE DIFFERENTIAL REDUCING REGULATOR CAUTION FEATURES

Inkling Fan Language Character Encoding Version 0.3

Pressure independent control valve (PICV) FLOWMATIC

OBSOLETE DESIGN DATA FOAM MAKER APPLICATION

For Nicholas and Christopher Rojas. CONCERTATO ON HYFRYDOL AND THE ASH GROVE SAB Choir. j œ. Sing loves. ex - throne; down, vic - faith - His.

#. $. (&,. " Joan Baez A. L. Webber McKennit E. Morriccone J. Mandel J. Lennon Enya

Preview Only EVIEW PREVIEW PREVIEW PREV EW PREVIEW PREVIEW PREVIE REVIEW PREVIEW W PREVIEW PREVIEW PREVIEW PREVIEW WINTER S FROST

[vln] [recorders] [tbn]

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

This Week s Sur vey Re sults. Bi cy cle and Pe des trian Is sues. Dan iel B. Rathbone, Ph.D., P.E. Ed i tor/pub lisher

Beating the defender in back-to-goal situations

Improve your passing, score more goals!

9. Child Soldiers-Reunion

Variable Area Flow Meters. VS Series

The Schuyler Sisters

Maranatha! Come, Lord Jesus. Eb /B b. œ œ œ œ œ œ œ œ œ œ œ œ œ. Eb (no3) œ œ n œ. œ œ Œ œ œ. Je - sus. Al - le - n œ œ œ œ

THE LIFE & CONTESTS OF BATTLING NELSON

Safety Shut-Off Valve HON 720

Traffic Safety Basic Facts 2008

Premium T-Shirt. Premium T-Shirt -KIDS. T-Shirt Lady Fashion. Price Public 29,00 Availability: 5 to 7 work days

HARD. Pop R&B groove. Words and Music by ROBYN FENTY, JAY JENKINS, CHRISTOPHER STEWART and TERIUS NASH. Yeah,

Safety Shut-Off Valve RMG 711

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions

FIRE SAFETY CASE STUDY OF A RAILWAY TUNNEL: SMOKE EVACUATION

Differential pressure controls, Type MP 54, 55 and 55A

Gas Pressure Regulator HON 300

Update of trade weights data underlying the EERs and HCIs

Meta-MEC Manual Motor Starters

PIN Flash 18 - Background tables

RELAY PRODUCT GUIDE CONTENTS

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

safety Shut-Off Valve HON 721

Prague 2010 was a high-quality Congress

THE URBAN TRANSPORTATION MONITOR

User Manual (TDS Reference Number T70 530) UNIMAT Electro-Pneumatic Tank Contents Gauge and Level Alarm EUROGAUGE

CHARLES SHADLE: SIX DICKINSON SONGS (2000) For Soprano and Clarinet

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

OTL Universal terminals

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

Prewired position switches FA series

POREC: The work done in Porec a beautiful town on the Croatian coast - made an important contribution to the cause of Fair Play.

Instruction Manual Contact Pressure Vacuum Gauge

How To Troubleshoot Low Pressure On Well Systems Page 1

Traffic Safety Basic Facts 2008

Intimations. Iowa Research Online. University of Iowa. Stephanie Gerette Pieczynski University of Iowa. Theses and Dissertations.

Traffic Safety Basic Facts 2008

ORLANDO GIBBONS, WHAT IS OUR LIFE? (The First Set of Madrigals and Mottets, 1612, no. 14)

Compact pressure switches for gas and air

Installation and Operating Instructions Bypass Flow Meter DST

Instruction Manual Differential Pressure Transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

Total Frequency Percent CAPS Graduate Graduate Intensive English

High-performance submersible pressure transmitter For level measurement Model LH-20

Gas Pressure Regulator RMG 201

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

TeSys protection components

CFSW. Hinges with built-in safety multiple switch

High-performance submersible pressure transmitter For level measurement Model LH-20

Traffic Safety Basic Facts 2010

STATE OF MICHIGAN DEPARTMENT OF NATURAL RESOURCES LANSING. 16 April 2013

Demo Version. mp3 s. Quality. Price ORIGINALDONOTCOPY. What do. Nowhere cheaper

MODELS CA-1 AND CA-2

CY LSOH Screened Halogen Free Control Cables with improved fire performance

THE URBAN TRANSPORTATION MONITOR

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

ANNUAL SUMMARY OF SOUTH AFRICAN NOTICES TO MARINERS 2009 EDITION

Old documentation - Only for your information! Product is not available anymore!

Electrical Sensing Edges

An-Institut der TU Bergakademie Freiberg. Equipment and Protectiv Systems intended tor use in Potentially Explosive Atmospheres,

Pushbuttons and Pilot Lights

G Corp PO Box 5322 Lacey, WA CORP.CO User Instruc on/ Safety Manual

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

High-performance submersible pressure transmitter For level measurement Model LH-10

Defending Principle: Developing Stage 1 Defence - T ight Shadow Defence! Coaching T ips. Notes. Warm Up. Net ball Co urt 1/5

Key Ward Information - Cowes South and Northwood (part of the Cowes cluster of wards)

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

1 Hocus Pocus Fiddlesticks

High-performance submersible pressure transmitter For level measurement Model LH-20

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Transcription:

HIGH VOLTAGE FUSE LINKS status 2004-08-20 - subject to alteration

Product information high voltage fuse links edition 2004/1 page Spe ci fi ca ti on...assembly....3...design....4...application....4 Ad van ta ges...4 Pro duc ti on programme......no mi nal voltage 6/12 kv...6...nomi nal voltage 10/24 kv...6...no mi nal voltage 30/36 kv...7 Tech ni cal data......no mi nal vol ta ge 6/12 kv...8...no mi nal vol ta ge 10/24 kv...9...no mi nal vol ta ge 20/36 kv...10 Di men sions...11 Time cur rent characteristics......no mi nal vol ta ge 6/12 kv...12...no mi nal vol ta ge 10/24 kv....13-14...no mi nal vol ta ge 20/36 kv...15 Cur rent li mi ting diagram......no mi nal vol ta ge 6/12 kv...16...no mi nal vol ta ge 10/24 kv....17-18...no mi nal vol ta ge 20/36 kv...19 2-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Specification Assembly Fuse body (1) The fuse body consist of ceramic material of high quality in brown, environmentally friendly colour. Contact caps (2) The con tact caps con sist of high co nduc ti ve, elec tro ly tic cop per and are eit her ni ckel or sil ver pla ted. Ex cel lent tight ness and re sul ting high re sis tan ce to ageing is achie ved due to a spe ci al me thod of rol ling by pres sing the con tact caps into the groo ve of the fuse bo dy's tube. Fuse element In si de the fuse body sil ver fuse ele ments con nec ted in par al lel (4) are wound around a star core (3). The se fuse elements are ex act ly adap ted to gua ran tee their cor rect functi on in case of short cir cuit cur - rents. The fuse ele ments are wel ded on to both con tact caps. Quartz sand fil ling The fuse body is fil led with quartz sand with pre ci se gra nu la ti on. Op ti mum arc ex tingu is hing as well as high interrupting capacity is guaranteed by the sand's granulation and composition. Striker (5) see page 4 sta tus 2004-08-20 - sub ject to al ter ati on 3-2004

Specification Design Parti al ran ge fuse links (back up fuse links) with striker for in door and out door applications High vol ta ge parti al ran ge fuse links are cur rent li mi ting fuse links. Their functi on is to in ter rupt any cur rent from the mi ni mum brea king cur rent I min to the ra ted brea king ca pa ci ty I 1. gua ran tee safe brea king of the lo west in ter nal trans for mer short cir cuit cur rent (se - con da ry ter mi nal short cir cuit) and can also in ter rupt the ma xi mum main short cir cuit cur rent (< nominal breaking capacity of fuse link). The striker mechanism (5) provides a visual indication of the operation of the fuse link. In con nec ti on with an in di ca ting de vi ce at the high vol ta ge dis con nec tor the stri ker can also be used as a mechanical indicator. dimensions see page 11 striker Application The ran ge of ap pli ca tions for high vol ta ge fuse links are the pro tec ti on of high vol ta ge po wer li nes, trans for mers, mo tors, con den sa tors as well as switch bo ards and dis tri bu ti on units for pub lic uti li ties and the in du stry. They guarantee safe protection of electrical equipment and installations against the thermic and dynamic effect of short cir cuit currents. 4-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Advantages one de sign for in door and out door ap pli ca tions high brea king ca pa ci ty up to 63 ka safe brea king at mi ni mum cut off cur rent time cur rent cha rac ter is tics in ac cor dan ce with VDE 0670 / part 4 and 402, ÖVE EN 60 282-1 low po wer dissipation sil ver fuse elements op ti mum in di ca ti on due to stri ker mechanism low swit ching voltage KEMA tested sta tus 2004-08-20 - sub ject to al ter ati on 5-2004

Production programme No mi nal voltage 6/12 kv ra ted vol ta ge ran ge 6/12kV design ra ted current A length e (mm) d (mm) w p ar ti cle num ber 6 3 292 56 1,6 3 BSDL06 10 292 56 1,6 3 BSDL10 16 292 56 1,6 3 BSDL16 20 292 56 1,6 3 BSDL20 25 292 56 1,6 3 BSDL25 31 5 292 56 1,6 3 BSDL32 40 292 56 1,6 3 BSDL40 50 292 56 1,6 3 BSDL50 63 292 56 1,6 3 BSDL63 80 292 65 2,1 3 BSDL80 100 292 65 2,1 3 BSDL100 125 292 88 3,7 3 BSDL125 No mi nal voltage 10/24 kv w = weight kg / piece p = pa cka ge unit (piece) ra ted vol ta ge range 12/24kV design ra ted current A length e (mm) d (mm) w p ar ti cle number 2 442 56 2,3 3 BSDM02 4 442 56 2,3 3 BSDM04 6 3 442 50,8 2,2 3 BSDM06 10 442 50,8 2,3 3 BSDM10 16 442 50,8 2,2 3 BSDM16 20 442 50,8 2,3 3 BSDM20 25 442 50,8 2,2 3 BSDM25 31 5 442 50,8 2,2 3 BSDM30 40 442 76,2 4,5 3 BSDM40 50 442 76,2 4,5 3 BSDM50 63 442 76,2 4,5 3 BSDM63 80 442 65 3,1 3 BSDM80 100 442 78 4,1 3 BSDM100 6-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Production programme No mi nal voltage 20/36 kv ra ted vol ta ge range 20/36kV design ra ted current A length e 1 (mm) d (mm) w p ar ti cle number 4 537 56 2,7 3 BSDQ04 6 537 56 2,7 3 BSDQ06 10 537 56 2,7 3 BSDQ10 16 537 56 2,7 3 BSDQ16 20 537 56 2,7 3 BSDQ20 25 537 56 2,7 3 BSDQ25 31 5 537 65 3,7 3 BSDQ32 40 537 65 3,7 3 BSDQ40 50 537 88 6,5 3 BSDQ50 63 537 88 6,5 3 BSDQ63 w = weight kg / piece p = pa cka ge unit (piece) sta tus 2004-08-20 - sub ject to al ter ati on 7-2004

Tech ni cal data in ac cor dan ce with IEC 60 282-1 / VDE 0670 part 4 ÖVE EN 60 282-1 di men sions to DIN 43 625 No mi nal voltage 6/12 kv ar ti cle num ber BSDL06 ra ted cur rent I N A 6 3 ra ted voltage U N kv ra ted brea king capacity I 1 ka min. brea king current I 3 = I min A cold resistance R cold mohm po wer dis si pa ti on P warm W 30 190 8 BSDL10 10 42 199 16 BSDL16 16 54 107 38 BSDL20 20 73 71 38 BSDL25 25 93 52 46 BSDL32 31 5 6/12 63 105 43 66 BSDL40 40 125 23 54 BSDL50 50 160 18 70 BSDL63 63 230 12 85 BSDL80 80 350 10,8 114 BSDL100 100 500 8,5 156 BSDL125 125 480 4 117 8-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Tech ni cal data in ac cor dan ce with IEC 60 282-1 / VDE 0670 part 4 ÖVE EN 60 282-1 di men sions to DIN 43 625 No mi nal voltage 10/24 kv ar ti cle num ber ra ted cur rent I N A ra ted voltage U N kv ra ted brea king capacity I 1 ka min. brea king current I 3 = I min A cold resistance R cold mohm po wer dis si pa ti on P warm W BSDM02 2 16 800 3 63 BSDM04 4 23 550 10 BSDM06 6 3 19 489 24 BSDM10 10 28 287 35 BSDM16 16 47 165 70 BSDM20 20 80 79,3 38 BSDM25 25 12/24 50 84 62,0 49 BSDM30 31 5 105 46,5 56 BSDM40 40 140 34,0 79 BSDM50 50 225 27,1 96 BSDM63 63 306 21,6 128 BSDM80 80 310 20,5 233 63 BSDM100 100 430 18,0 400 sta tus 2004-08-20 - sub ject to al ter ati on 9-2004

Tech ni cal data in ac cor dan ce with IEC 60 282-1 / VDE 0670 part 4 ÖVE EN 60 282-1 di men sions to DIN 43 625 No mi nal voltage 20/36 kv ar ti cle num ber ra ted cur rent I N A BSDQ04 4 ra ted voltage U N kv ra ted brea king capacity I 1 ka min. brea king current I 3 = I min A cold resistance R cold mohm po wer dis si pa ti on P warm W 20 900 32 BSDQ06 6 3 23 827 39 BSDQ10 10 34 520 65 BSDQ16 16 31 5 70 210 67 BSDQ20 20 100 165 84 20/36 BSDQ25 25 110 125 100 BSDQ32 31 5 135 85 119 BSDQ40 40 203 65 176 BSDQ50 50 20 220 42 183 BSDQ63 63 360 35 271 10-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Dimensions U N Kv 6/12 10/24 20/36 I N A d e f s1) 6 3-50 56 63-100 65 292 33 24 125 88 2-6 56 33 24 6 3-31 5 50 8 34 26 442 40-63 76 2 34 26 80-100 65 33 24 4-25 56 32-40 65 537 33 24 50-63 88 1) s...ma xi mum dis tan ce of stri ker af ter operation sta tus 2004-08-20 - sub ject to al ter ati on 11-2004

Time cur rent characteristics for high vol ta ge fuse links 6/10kV 6 3-125A 10000 t vs [s] 6,3 10 16 20 25 31,5 50 63 80 100 125 40 1000 100 10 1 0,1 0,01 6,3 10 16 20 25 31,5 40 50 63 80 100 125 0,001 10 100 1000 10000 I [A] 12-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Time cur rents characteristics for high vol ta ge fuse links 10/24kV 2-4A and 80-100A 1000 t vs [s] 100 10 100A 80A 1 0,1 0,01 4A 2A 0,001 10 100 1000 10000 I [A] sta tus 2004-08-20 - sub ject to al ter ati on 13-2004

Time cur rent characteristics for high vol ta ge fuse links 10/24kV 6 3-63A 1000 t vs [s] 100 10 1 63A 50A 40A 31,5A 0,1 25A 20A 16A 0,01 10A 6,3A 0,001 10 100 1000 10000 I [A] 14-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Time cur rent characteristics for high vol ta ge fuse links 20/36kV 4-63A 10000 t [s] 2 4 6,3 10 16 20 31,5 25 40 50 63 1000 100 10 1 0,1 0,01 0,001 2 4 6,3 10 16 20 25 10 100 1000 10000 I [A] 31,5 40 50 63 sta tus 2004-08-20 - sub ject to al ter ati on 15-2004

Current limiting diagram, 6/12 kv, 6-125A al rea dy interrupt the in crea se of short cir cuit cur rents pri or to rea ching the pos si ble peak va lue. The dia gram shows the li mi ting let-through cur rent va lu es (peak va lu es) de pen dent on the un pro tec ted short cir cuit current (effective value) under unfavourable switching conditions and the power factor assigned to the respective no mi nal cur rent of the NH-fuse links. 100000 i d [A] nicht non limiting cut off current (peak) 1,8 '' 2 I K I r [A] 10000 1,0 '' 2 I K 125 100 80 63 50 40 31,5 25 20 16 10 6,3 1000 100 10 100 1000 10000 100000 I K '' [A] 16-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Current limiting diagram, 10/24 kv 2-4A, 80-100A al rea dy in ter rupt the in crea se of short cir cuit cur rents pri or to rea ching the pos si ble peak va lue. The dia gram shows the li mi ting let-through cur rent va lu es (peak va lu es) de pen dent on the un pro tec ted short cir cuit current (effective value) under unfavourable switching conditions and the power factor assigned to the respective no mi nal cur rent of the NH-fuse links. 100.000,00 i d [A] non limiting cut off current (peak) 1,8 '' 2 I K I r [A] 1,0 '' 2 I K 100 80 10.000,00 4 2 1.000,00 100,00 10,00 100,00 1.000,00 10.000,00 I K '' [A] 100.000,00 sta tus 2004-08-20 - sub ject to al ter ati on 17-2004

Current limiting diagram, 10/24 kv 6,3-63A al rea dy interrupt the in crea se of short cir cuit cur rents pri or to rea ching the pos si ble peak va lue. The dia gram shows the li mi ting let-through cur rent va lu es (peak va lu es) de pen dent on the un pro tec ted short cir cuit current (effective value) under unfavourable switching conditions and the power factor assigned to the respective no mi nal cur rent of the NH-fuse links. 100.000,00 i d [A] non limiting cut off current (peak) 1,8 '' 2 I K I r [A] 1,0 '' 2 I K 10.000,00 63 50 40 31,5 25 20 16 10 6,3 1.000,00 100,00 10,00 100,00 1.000,00 10.000,00 I K '' [A] 100.000,00 18-2004 sta tus 2004-08-20 - sub ject to al ter ati on

Current limiting diagram, 20/36 kv, 4-63A al rea dy interrupt the in crea se of short cir cuit cur rents pri or to rea ching the pos si ble peak va lue. The dia gram shows the li mi ting let-through cur rent va lu es (peak va lu es) de pen dent on the un pro tec ted short cir cuit current (effective value) under unfavourable switching conditions and the power factor assigned to the respective no mi nal cur rent of the NH-fuse links. 100000 i d [A] non limiting cut off current (peak) 1,8 '' 2 I K I r 1,0 '' 2 I K 10000 63 50 40 31,5 25 20 16 10 6,3 4 2 1000 100 10 100 1000 10000 100000 I K '' [A] sta tus 2004-08-20 - sub ject to al ter ati on 19-2004

Austria M. Schnei der Schaltgerätebau und Elektroinstallationen GmbH A-1160 Wien, Lienfeldergasse 31-33 Tel. +43 1 486 16 74-0, Fax +43 1 486 16 74-34 e-mail: office@mschneider.at http://www.mschneider.at Germany M. Schnei der - An na berg GmbH D-09456 Annaberg-Buchholz Alte Post straße 5 Tel. +49 37 33 85-201, Fax +49 37 33 85-226 e-mail: info@mschneider.de http://www.mschneider.de M.Schnei der - Office Leip zig D-04157 Leipzig Roßlauer Straße 10 Tel: +49 341 55 03 571; Fax +49 341 55 03 572 e-mail: franz.john.mschneider@t-online.de Czech Republic M. Schnei der CZ s. r. o. CZ-53304 Sezemice, Pardubická 437 Tel. +420 466 931 580, Fax +420 466 931 487 e-mail: msoffice@mschneider.cz http://www.mschneider.cz Hungary M. Schnei der - hun garia erõsáramú, mûszaki, ker eskedelmi és szolg. kft. H-1039 Budapest, Attila u. 31-33 Tel. +36 1 240 2000, Fax +36 1 240 2001 e-mail: m.schneider@axelero.hu http://www.mschneider.hu Poland M. Schnei der - pol ska Spó³ka z o.o. PL- 86-031 Osiel sko k / Bydgoszczy, ul. Sok ola 8 Tel. +48 52 320 33 23, Fax +48 52 320 33 43 e-mail: office@mschneider.pl http://www.mschneider.pl 20-2004 sta tus 2004-08-20 - sub ject to al ter ati on