DMX 3 - DMX 3 MF INSTALLATION OPERATION MAINTENANCE. Your distributor : TECHNICAL INSTRUCTIONS (e) Revision

Similar documents
HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

K Page 1 of 48 Air Intake - Pg. 17

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

OWNER S TECHNICAL MANUAL

CAST IRON SAFETY VALVE TYPE 6301

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

30T A/Manual Hydraulic Shop Press

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Easy Nest Kits. Installation Suggestions

Operation Manual Air Saver Unit ASV5000 Series

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Manual Actuated Boiler Blowdown Valves

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

VACUUM REGULATORS CONTENTS

Installation, Operation and Maintenance Manual for Back Pressure Regulator

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

MUD 1. Vent check valves. Instruction and maintenance manual.

Air Operated Hydraulic Pumping Systems to 50,000 psi

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Hydro-Pneumatic Cylinder HPL-B / HPL-C

Series IRV1000/2000/3000

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Combination Air Valve

SIHI LPH-X - Liquid Ring Compressors

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

TECHNICAL DATA. Q = C v P S

VB85/ Pressure regulating valve (Unloader)

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Operating and maintenance manual Filter and reducing station Series / 1.0

Hydraulic Punch Drivers

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Liquid ring compressors

RD(H)20/25 Pressure-Reducing Regulator User Manual

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

TECHNICAL DATA. Q = C v P S

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

TECHNICAL DATA. Q = C v P S

6301 TYPE CAST IRON SAFETY VALVES

User's Manual. MixRite TF 10. Edition 05.08

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Model Series 62 Constant Differential Relay

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Lesson 6: Flow Control Valves

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

EXH. Specifications. Descriptions. Min. working pressure MPa

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Unit 24: Applications of Pneumatics and Hydraulics

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Introduction. Part one: Identify the Hydraulic Trainer Components

Tank Blanketing Pressure Regulators RHPS Series

TECHNICAL DATA. Q= Cv S

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Air preparation units

ZZYP TYPE AUTOMATIC PRESSURE REGULATING CONTROLL VALVE

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

MF2M Monnier Miniature Compressed Air Filter

WW-720. Pressure Reducing Control Valve

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

KP-APN-22 Pneumatic Carton Stapler

WW-720. Pressure Reducing Control Valve

Installation and User Manual

Liquid ring vacuum pumps single-stage

TECHNICAL DATA. Q = C v P S

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

Type 4708 Supply Pressure Regulator

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

PULSAR4 Pressure regulating valve (Unloader)

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

TECHNICAL DATA. Q = C v P S

OPERATION MANUAL NTF-15

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Model GPR Primary Pressure Regulating Valve. Instruction Manual

PULSAR4 Pressure regulating valve (Unloader)

Float Operated Level Controllers

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Transcription:

TECHNICAL INSTRUCTIONS 38 (e) Revision DMX 3 - DMX 3 MF INSTALLATION OPERATION MAINTENANCE BLACKMER ZI PLAINE DES ISLES F- 89000 AUXERRE Technical Assistance / Repair.....Tél. : +33 3.86.49.86.03.............................Fax : +33 3.86.49.86.48 Spare parts / Advice............Tél. : +33 3.86.49.86.40............................. +33 3.86.49.87.09.............................Fax : +33 3.86.49.87.7 e-mail : contact@blackmer-mouvex.com BLACKMER GmbH Auf dem Zehnthöbel D-6457 BUTTELBORN - WORFELDEN Tel :......................+49/65/9869-0 Fax :.....................+49/65/9869-0 e-mail : willkommen@blackmer-mouvex.com Your distributor :

INSTALLATION : PAGES - DMX overall dimensions 3 - Selective valve overall dimensions 3 - SBL MF valve overall dimensions 4 - Characteristics to comply with 5 - List of counters that can be fitted to the unit 6 - DMX 3 external pneumatic diagram 7 - DMX 3 MF external pneumatic diagram, with manual valve 8 - DMX 3 MF external pneumatic diagram, with pneumatic valve 9 - DMX (alone) sealing 0 - DMX (with manual valve) sealing - DMX (with pneumatic valve) sealing - Wording to stamp on the measurement unit plate 3 USE: PAGES - Schematic diagram 4 - SBL MF valve use 5 - Measurement compartment discharge 6 - Recovery not measured 7 - Use of the pump as a transfer pump 8 - Use as flow detector 9 ASSEMBLY/DISASSEMBLY : PAGES - DMX assembly drawing 0 - Valve assembly drawing - Cover assembly drawing /3 - Nomenclature 4 MALFUNCTIONING : PAGES - Causes and remedies 8 Technical Instructions N 38 /8

0 Breather Tube 4x6 5 Stop valve control Tube 4x6 4 Bypass output Tube 4x6 3 Free distribution signal Tube 4x6 3-bar air supply Tube 4x6 5.5-bar air supply Tube 4x6 V Filter emptying/attachment P Identification plate H Cover clearance D Bleed valve Tube 8x0 B Dry valve A Basket clearance A Compressed air supply port G /4 B Predetermination variant G /8 C Breather (connected to hose 4x6 G /8 minimum, directed downwards) M5 D Drip strip COMPENSATED SELECTIVE VALVE Note: Make sure to direct pneumatic supply port B of the predetermination valve towards the selective valve product output side. Technical Instructions N 38 3/8

OVERALL DIMENSIONS DMX 3 MF - mm IMPORTANT The directions DM and DL must be adhered to. To ensure correct draining, never have the outlet DL pointing upward D Valve exhaust plug E Compressed air inlet orifice G /8 G Lubricator J Release for disassembly (J=5) (J=0) P Identification plate S Compressed air utilisation orifice (tube 4x6) The connection of the automatic draining plug (BVA) outlet is to be made with ¾ diam. Welded tube held by a collar without the need for a gradient. There are two possible connections : - return at the top of a compartment - return to a separate tank Technical Instructions N 38 4/8

CHARACTERISTICS TO COMPLY WITH MF version Use of a 3-way valve before an SBL MF type manual control counter or selective type pneumatic counter. Installation Port centerlines horizontal, pneumatic connections directed upwards. Supply Under load (gravity supply). The connection pipe from the compartment must be at a 3% slope continuously downwards slope 3%. The vacuum generated by the maximum use rate shall not exceed 0.50 bar; Connection Flanged directly to the pump suction circuit. Otherwise, schedule : - Distance 0.5 m : horizontal connection pipe - Distance >0.5 m : connection pipe with a down slope to the pump 5%. Temperature range -0 C to +70 C Maximum hydraulic 3 bar pressure in the DMX Maximum pneumatic 5.5 bar pressure in the DMX Pneumatic supply One lubricator filter must be used. Minimum pressure: 5.5 bar. Minimum delivery 00 l Maximum flow rate 66 m 3 /h Measurable fluids Hydraulic pressure constraints Ordinary petrol, 5-star petrol, diesel fuel, domestic fuel oil, kerosene, etc. Flow rate m 3 /h 30 40 50 66 Valve calibration (bar) 0.3.4.4.4 Minimum operating.4.9..6 pressure (bar) Approval validity - European with mechanical counter used - French only with electronic counter used Filtration capacity Bottom basket :,300 microns Top basket : 400 microns Technical Instructions N 38 5/8

LIST OF COUNTERS THAT CAN BE FITTED TO THE UNIT MECHANICAL COUNTERS MANUFACTURER MODEL MINIMU M FLOW RATE (m 3 /h) MAXIMUM FLOW RATE (m 3 /h) LIQUID CONTROL M7.7 7 0.5 LIQUID CONTROL M5 5.4 54 0.5 LIQUID CONTROL M5 6.6 66 0.5 SATAM ZC7.4.4.4 4 8 SATAM ZC7.4.48 4.8 48 6 OIL METER SBM 75 3 30 0 OIL METER SBM 50 6 60 0 PERNIN NVR 0 0 8 PERNIN NVR 45 4.5 45 8 PERNIN NVR 80 8 80 8 MAXIMUM PRESSURE (bar) APPROVAL CERTIFICATES UK8 78 STD 3994, dated July 9, 99 UK8 78 STD 3994 dated July 9, 99 UK8 78 std 3994 dated July 9, 99 F95.00.4.00.0 dated July, 995 F95.00.4.00.0 dated July, 995 D8 //5.43.9 dated September 5; 99 D79 5.43.0 dated February, 989 F96.00.4.00.0 dated September, 996 F96.00.4.00.0 dated September, 996 F96.00.4.00.0 dated September, 996 ELECTRONIC COUNTERS LIQUID CONTROL measurement chambers M7, M5 or M5 (cited above) associated with the electronic indicator and calculating device, according to decision No. 99.00.4.004. dated June 4, 999 Technical Instructions N 38 6/8

EXTERNAL PNEUMATIC DIAGRAMS DMX 3 EXTERNAL PNEUMATIC DIAGRAM Optional component Rigid sealed pipe A - P>6 bar connected as bypass on movement takeoff A - Lubricator filter A3 - Emergency stop A4-5.5-bar pressure regulator A5 - Flow regulator A6-3-bar pressure regulator A7 - "or" cell A8 - Motor acceleration cylinder A9 - Flow rate detector A - CC8 pump with pneumatic bypass, not spring-loaded A - DMX 3 Technical Instructions N 38 7/8

t A - P>6 bar connected as bypass on movement takeoff A - Lubricator filter A3 - Emergency stop A4-5.5-bar pressure regulator A5 - Flow regulator A6-3-bar pressure regulator A7 - "or" cell A8 - Motor acceleration cylinder A9 - Flow rate detector A0 - SBL MF manual FD valve A - CC8 pump with pneumatic bypass, not spring-loaded A - DMX 3 MF Technical Instructions N 38 8/8

A - P>6 bar connected as bypass on movement takeoff A - Lubricator filter A3 - Emergency stop A4-5.5-bar pressure regulator A5 - Flow regulator A6-3-bar pressure regulator A7 - "or" cell A8 - Motor acceleration cylinder A9 - Flow rate detector A0 - Selective pneumatic valve A - DMX 3 MF A3-5/3 distributor with 3 and 5 exhausts sealed, prohibiting any blanking Technical Instructions N 38 9/8

DMX 3 SEALING LAYOUT Em (scale ) Straight coupling or Elbowed coupling LAYOUT Em (scale.5) Technical Instructions N 38 0/8

SEALING WITH MANUAL VALVE OPERATION OF DMX 3 MF WITH FREE DISTRIBUTION AND MANUAL VALVE Measured distribution -way valve Free distribution Technical Instructions N 38 /8

SEALING WITH PNEUMATIC VALVE OPERATION OF DMX 3 MF WITH FREE DISTRIBUTION AND PNEUMATIC VALVE -way valve Measured distribution Free distribution Technical Instructions N 38 /8

WORDING TO STAMP ON THE MEASUREMENT UNIT PLATE (supplied blank) model or drawing INSTALLER MEASUREMENT UNIT Blackmer Mouvex 5 Rue du Sahel, 7505 PARIS Assembly No. Measured fluids Year Maximum flow rate Minimum flow rate Max. pressure Min. pressure Stamps For mechanical counter A : Name of the installer B : "E DMX 3" or "E DMX 3 MF" B : Not applicable For electronic B: "F994603" C : "F99" counter C: Not applicable D : "460" D: Not applicable E : Serial No. F : "Minimum delivery 00 liters" G : Measured product H : Year i 30 40 50 66 J K Minimum permissible flow rate per counter Maximum permissible flow rate per counter L 0.3.4.4.4 Technical Instructions N 38 3/8

OPERATION Your delivery system is equipped with a gas separator DMX 3 MF in combination with a pump CC8 with pneumatic bypass. This allows you to carry out distribution and measurement of a product (DF0 -Domestic Fuel Oil in most cases for the DMX 3 MF). The DMX 3 MF do not require any specific operation, all that is needed is to link the hose 7 to the compartment drained, to open the compartment valve and to start the pump. The measured distribution can begin. Vane pump CC8 with non-spring loaded 3-way valve type SBL-MF allowing pneumatic bypass opeartion in measured distribution (MD) 3 Gas separator DMX 3 MF or in free draining (FD) 4 Degassing circuit connected to a tank 3 Pressure gauge 5 Counter 4 Drain valve 6 Manual stop valve 5 3-way valve type SBL Plain hose on hosereel for measured distribution 6 Automatic draining valve Hosereel 7 Check valve (not necessary when 3 Gradual closing type nozzle equipped with flow detector) 7 Suction pipping or hose 8 Drip tray 8 Filter-Lubricator assembly 9 Draining tank Technical Instructions N 38 4/8

MEASURED DISTRIBUTION, SBL-MF valve in DM postion The DMX 3 MF does not require any specific operation, all that is needed is to link the hose 7 to the compartment to be drained, to open the compartment valve and to start the pump. The measured distribution can begin. Other functions, SBL-MF valve in FD position Before moving to another functionning mode, drain the installation between the valves 4 and in order to avoid product mixes and product loss. To drain : make sure that the installation includes an automatic draining plug (ADP) well locked make sure that the foam return compartment (or drainage tank), can accommodate the volume of the installation to be drained. start the pump place valve in the FD position make an air entry to valve 4 The operation is finished after evacuation of the foam visible in the transparent hose Venting return The plug ADP is mounted on the free draining port (FD) and when the valve lever is placed in this position, allows draining by the venting return, the suction piping, the DMX 3 MF and the pump. Technical Instructions N 38 5/8

DISCHARGING A MEASURED COMPARTMENT USING THE PUMP Remove the plug ADP (6), connect the valve to the storage tank, connect the hose 7 to the compartment to be drained, open the corresponding valve and start the pump. When draining is completed, drain the hose into the storage tank. Technical Instructions N 38 6/8

UNMEASURED RECOVERY Connect the tank from which the recovery is to be made to the valve 5. Remove the plug ADP 6 and connect the valve using a hose to the compartment to be filled through the dome (do not forget to maintain hose in the compartment). Start the pump and carry out the recovery. Please note : In recovery, once the pump has been started, it is not necessary to run it at too high a speed because depending on the suction conditions, a state of cavitation can be quickly reached, that is : poor functioning of the pump, noise, vibration, and flow inferior to normal flow considering the pump speed. To return to correct functioning, it is only necessary to reduce the rotation speed of the pump, the lenght of the hose and to increase the hose s diameter. Technical Instructions N 38 7/8

OPERATION USING THE PUMP AS A TRANSFER PUMP Remove the plug ADP (6), connect the tank from which the transfer is to be made to the valve (5), connect the valve () to the tank to be filled and start the pump. Technical Instructions N 38 8/8

FLOW DETECTOR The flow detector is controlled by simple manipulation of the nozzle. It is obligatory that the flow detector be linked to a pneumatic acutation cylinder, its effect is to : accelarate the engine turnover increase the pump pressure, when the nozzle is opened and the flow goes over the preset threshold (approximately 5 to 7 m3/h) slow the engine turnover reduce the pump pressure, when the gun is closed and the flow falls below the preset threshold (approximately 5 to 7 m3/h) Note For a good functionning, the flow regulator must be regulate for a delivery > at the preset Threshold (5 to 7 m3/h) B Regulation access cover J Dismantling clearance D Decompression outlet G /8 P Plate E Compressed air inlet G /8 S Outlet for use with compressed air G /8 F Microfilter Technical Instructions N 38 9/8

DMX Technical Instructions N 38 0/8

COMPLETE DRY VALVE Technical Instructions N 38 /8

DMX COVER Technical Instructions N 38 /8

DMX MF COVER Technical Instructions N 38 3/8

NOMENCLATURE Key: º Assemblies and parts that may be supplied ITEM NUMBER DESCRIPTION º 3 5 60a 6 6b Complete body Bare body Stud Stud Identification plate Rivet Plug º 6 7 8 9 43 Complete filter cover Cover O-ring Filter use plate Rivet Nut º 4 7 8 9 39 40 50 44 47 4 59 9 46 30 45 5 54 0 04 3 4 5 6 7 94a 94b Complete DMX cover Bare cover Screw Flat seal Nut Washer Float valve seat assembly Seat support Washer O-ring Valve seat Float valve assembly Valve Valve seal Valve body Pin Complete float Complete ball bearing valve Coupling Valve body O-ring Screw Flat seal Screw Ball Support Plate Rivet Technical Instructions N 38 4/8

ITEM NUMBER DESCRIPTION º 0 3 6 4 Complete bottom basket Bare basket Insert Pin Flat seal Cap nut º 5 6 3 5 Complete top basket Bare basket Spring blade Screw º 60 6 6 64 66 68 73 6 7 7 3 4 3 Complete DMX cover Cover Screw Plate Flat seal Throttle valve Lead seal Banjo coupling Sealing partition cross-feed Partition cross-feed Valve body Filter Flat seal º 80 º 50 50 503 504 505 506 54a 54b 507 508 º 50 5 5 53 3 Complete dry valve Complete body Bare body Stud Bearing Flat seal Plug Plate Rivet Valve Plug Complete float Rod Float Seal Technical Instructions N 38 5/8

ITEM NUMBER DESCRIPTION º 50 54 5 5 53 º 530 53 53 54 543 544 550 55 55 553 554 555 556 509 557 º 60 60 6 6 63 Complete double seat Shell bearing O-ring Double seat Ball Complete safety float Float Seal Exhaust plug Seat Flat seal Cover O-ring Nut Banjo screw O-ring Banjo coupling Pipe O-ring Washer Complete pipe Ball Coupling Elbow Tube º 95 Measurement assembly plate (delivered separately) Technical Instructions N 38 6/8

ITEM NUMBER DESCRIPTION variants º 60 6 6 64 66 68 7 7 73 6 9 3 7a 7b 4 3 8 6 DMX MF complete cap Cap Screw Plate Flat seal Throttle valve Sealing partition cross-feed Partition cross-feed Lead seal Banjo coupling Pneumatic distributor Valve body Filter Flat seal Washer Nut - Kit of spare parts º 560 Set of seals and dry valve balls 509 + 5 + 53 + 544 + 55 + 554 + 60 º 00 Set of seals and filter screws 3 +5 + 8 + 6 + 4 + 43 º 05 Set of seals and DMX screws 8 + 9 + 39 + 40 + 6 + 66 + 68 + 73 NOTE - To order spare parts, indicate: - The TYPE and REGISTRATION NUMBER of the pump (stamped on the compressor plate) - The wording: Technical Manual No. P 38 - The ITEM numbers and the DESCRIPTIONS of the required parts. Only parts with the symbol º before the item number can be provided (complete assemblies or separate parts). Technical Instructions N 38 7/8

MALFUNCTIONING CAUSES AND REMEDIES PROBLEMS No flow See 6-5 Irregular flow See - - 3-7 - 8 No high flow rate See 4-5 - 7-8 - 9-0 - 5-6 No low flow rate See 0 - Hydrocarbons in the pneumatic circuit See 9 The counter does not stop when there are no more products to supply See 7-8 - - 4 Metrology error on stock rupture test See 3 POSSIBLE CAUSES AND REMEDIES - Air intake on suction pipe - Vacuum 0.50 bar in the DMX Reduce losses of head on suction pipe or reduce flow rate 3 - Vortex effect in the compartment Install an anti-vortex device 4 - DMX filter clogged Clean the filter 5 - No air or not enough air in the bypass Check circuit sealing and calibration of pressure regulators 6 - Condensate chamber of dry valve full Bleed it using valve (507), check that. Foreign bodies do not affect movement of the float (5). The seal (53) is in good condition 7 - Cover (4) HS assembly may have a sealing fault at the float valve (9) Replace cover assembly 8 - Cover (60) HS assembly may have a sealing fault or incorporate an operating fault in the valve (68) Replace cover assembly 9 - Bypass diaphragm pierced Replace diaphragm 0 - Float detector adjustment wrong Refer to flow detector Instructions for adjustment - Exhaust pipe of flow detector clogged - Calibration valve inappropriate or defective Check compliance with recommendations 3 - Operating pressure too low Check compliance with recommendations. necessary, to increase losses of head. Add a diaphragm, if 4 - Defective FD valve Check that it does not send air to the DMX at (3) when in MD position 5 - Closing or blocking of a component in the system Check opening of valves and the counter 6 - Hydrocarbon paraffins due to excessively low temperature Temporarily remove the top basket (5) Technical Instructions N 38 8/8