brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps

Similar documents
brands you trust. Technical Datasheet DEPA DH Next Generation Teflon PTFE Air Operated Double Diaphragm Pumps

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

PX1 PX1 PERFORMANCE M E T A L WIL T-12

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

DEPA Air Operated Diaphragm Pumps

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

2/2-Way Proportional Valve (motor-driven)

627 Series Pressure Reducing Regulators

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

Gas Pressure Regulator HON 502

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

MIDGETBOX DIAPHRAGM PUMPS

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

2-Port Seat Valves with Flange, PN 16

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

ELRO IP/ XP Peristaltic Pumps

OWNER S TECHNICAL MANUAL

Pressure and Flow Control Valves DBGM, German and European Patents

PX800 M E T A L PX800 PERFORMANCE WIL T-08

Pressure balanced valves (PN 25)

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Safety Shut-Off Valve HON 720

2-Port Seat Valves with Flange, PN 16

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

DIAPHRAGM GAS SAMPLING PUMPS

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

Pressure and Vacuum Switches for Process Applications

Pressure Independent Control Series

DN300 DN2000 C Plunger Valve

STANDARD HIGH PRESSURE COMPRESSORS COMPACT PACKAGE FOR DEMANDING APPLICATIONS

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

PFH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Weight 2.65 kg 12.6 kg. Gripping force 630 N 2950 N

Series MX pressure regulators 3/

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

kyone for All - Unique Mixproof

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

I Connected Industrial. HON 5020 Gas Pressure. Enabling Dependable Gas Operations

Air Amplifiers & SYSTEMS

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

NEW TYPE M PRESSURE RELIEF DEVICE

Seated valve for steam (PN 25)

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Pressure Relief Valve DHV 718

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

kysimply Unique Single Seat

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Low-pressure diaphragm pumps for product feeding Feeding

Shut-off ball valve Type GBC

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Expansion Vessels for Potable Installations

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Armatures for analytical probes

Glass tube flowmeters Series 2000

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

RR 16 Commercial & Industrial Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

SIHI LPH-X - Liquid Ring Compressors

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Mass Flow Controller (MFC) for Gases

1805 Series Relief Valves

I Connected Industrial. HON 5020 GAS PRESSURE REGULATOR Enabling Dependable Gas Operations

Pressure Reducing Valve DMV 755

Declaration of Conformity as per Directive 97/23/EC

Safety Relief Valve HON 832

WE SAY: REFILL PLEASE!

Workshop Compressors CLASSIC Series

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

MEDAP-MOBILE GAS SUPPLY

Shut-off ball valve Type GBC

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

SÜDMO ASEPTIC PROCESS VALVE SECURE FOOD & BEVERAGE ASEPTIC PROCESS VALVE SECURE

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Seated valves VRB 3, VRG 3

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Diaphragm pumps. Krautzberger GmbH / Subject to change

Transcription:

brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps

Features and Benefits DEPA DH Next Generation Air Operated Double Diaphragm Pump Series DH15, DH25 and DH40 are made of cast aluminum developed for industrial applications. Flexible Multiport-Connections A customized manifold design that improves ball valve guidance, increases functionality and provides up to 25 different installation options Error free assembling in combination with singlecenter block Multi-porting provides many options for installation e.g.: - Vertical orientation can be easily used for emptying of drums - No additional adapters are necessary Innovative Flange-Design "Block-mounted pump and air chambers provide a safe and well-defined diaphragm clamping mechanism. The diaphragm is fixed to its specifications to provide consistent lifetime wear and tear and eliminate overstretching of the pump Outer rim of diaphragm is held like an O-ring with exactly defined position and deformation, due to block bolted pump chamber Improved leakage tightness, through consistent diaphragm fixture No alignment needed for pump chamber and center block 2 Maintenance In Place (MIP) Cast feet integrated in the center block housing enable maintenance in place that can reduce downtime by up to 25%*, decrease the number of required parts by 30%* and eliminate the need to remove the pump for maintenance Optimized for error-free disand reassembling, also for built-in situation Rubber feet can easily be mounted due to slotted locating hole in the center block housing *Compared to the previous model as determined by internal testing High Efficiency Flow design with Free- Flow-Path technology can accommodate particle sizes up to 25mm (DH40), increase the scope of applications and reduce the total cost of ownership through enhanced efficiency of up to 37%* Reduced dead volume as the shape of the chamber has been optimized for the diaphragm design and dimensions Additionally available with DEPA AirSave System with low starting pressure Optimized for industrial applications on account of low noise-emission and high leakage

Features and Benefits Applications The aluminum housing material with universally selectable interior allows versatile application possibilities. For instance in Painting- and coating industries Printing- and gluing machines Mechanical engineering and construction Automotive Sizes DEPA DH Next Generation Air Operated Double Diaphragm Pumps of aluminium series are available in nominal sizes of ½ (DN15), 1 (DN25) and 1 ½ (DN40). Equipped with DEPA AirSave System or internal airvalve. Size 15 25 40 Suction height (m), dry 1) 3) 2,5 6,0 6,0 Max. solid size (mm) 6 10 15 Weight (kg) 2.0 8.2 12.0 Min. start-up pressure (bar) 2) 0,5 1) At 2 bar air pressure (DH15/25), 7 bar (DH40) 2) AirSave System (M-valve) 3) For valve seat/valve ball combination of PTFE or stainless steel the suction height will be reduced Temperature Operation temperature of aluminum material -10 C to +130 C (+14 F to +266 F) Further limitations are according to interior of pump, see table with product wetted interior Product wetted interior Max. Temperature ( C) NBR -15 bis +90 EPDM -25 bis +90 NRS -15 bis +70 FKM -5 bis +120 DEPA nopped S 4-20 bis +110 PTFE -5 bis +130 DEPA nopped E 4-10 bis +130 Applied Guidelines ATEX compliant in accordance with directive 94/9/ EC equipment group II, category 2GD, Explosion group IIB Tx (II 2 GD IIB Tx) Machinery Directive 2006/42/EC ATEX-compliant II 2GD IIB Tx Marking and Identification The pumps are provided with a nameplate which the pump code, serial number, date of manufacturing, max. allowed temperature and pressure. The DEPA pump coding gives all information about size, material and equipment which allows accurate for linkage to spare parts. 3

Pump Sizes and Equipment DH 25 - FA B S E T Connecting Dimension DN (mm) / inch Housing Material 15 / ½ Aluminium 25 / 1 Aluminium 40 / 1 ½ Aluminium Material Options Material Diaphragm Valve Seat Valve Ball NBR N N N 1) EPDM E E E 1) NRS B B B 1) FKM F F - DEPA nopped S 4 S - - PTFE T T T DEPA nopped E 4 Z - - Stainless Steel - R R NBR with core - - Y 1) NRS with core - - V 1) 1) Not for size 15 Further material options are available upon request Product Ports / Orientation of Manifolds S1 (inlet from bottom) S2 (inlet aligned with air inlet) S3 (inlet right hand side / view to air inlet) S4 (inlet at opposite side of air inlet) S5 (inlet left hand side / view to air inlet) 1) Not valid for DH15 with AirSave System Suction Port Discharge Port D1 D2 D3 D4 D5 (outlet to the top) (outlet at opposite side of air inlet) outlet right hand side / view to air inlet) (outlet at same side as air inlet) (outlet left hand side / view to air inlet) A B C O 1) P D - E Q 1) R F G H T 1) U I J K W 1) X L M N Y 1) Z S5 D5 air inlet S2 D = Discharge Side S = Suction Side D4 D1 S1 D2 S4 D3 S3 4

L E I D C L E D C Dimensions Dimensions (mm) Size 15 25 40 A 136 165 182 B 207 272 370 C 180 241 307 D 266 340 437 E 52 61 80 F 34 38 50 G 99 116 116 H 116 154 206 I 89 122 155 K 174 (186) 1) 234 266 L 18 23 30 A B M 105 134 165 H Air inlet M-Valve (inch) 2) G 1/2" 1) External DEPA AirSave System 2) Internal airvalve G3/8" Pressure side Exploded view Air inlet Suction side A B H F M K G 5

Performance Curves Example for pump selection Required is 2 m³/h as the flow rate at a discharge pressure of 4 bar. Recommend is the DL 25 for this application. The needed air supply pressure is 4,3 bar. This equals an air consumption rate of 13 m³/h. Type DH15 8 bar Ql = 5m /h Ql = 10m /h Ql = 15m /h DH15-FA Discharge Pressure 7 bar 6 bar 5 bar 4 bar 3 bar Ql = 20m /h Ql = 25m /h Ql = 30m /h Ql = 35m /h 2 bar 1 bar 0 bar 0.0 m /h 0.5 m /h 1.0 m /h 1.5 m /h 2.0 m /h 2.5 m /h 3.0 m /h 3.5 m /h 4.0 m /h Displacement Type DH25 Discharge Pressure 8 bar 7 bar 6 bar 5 bar 4 bar 3 bar Ql = 10m /h Ql = 20m /h Ql = 30m /h Ql = 40m /h DH25-FA Ql = 50m /h Operating Point Ql = 60m /h Ql = 70m /h 2 bar 1 bar 0 bar 0.0 m /h 2.0 m /h 4.0 m /h 6.0 m /h 8.0 m /h 10.0 m /h 12.0 m /h Displacement Type DH40 8 bar 7 bar Ql = 10m /h Ql = 20m /h Ql = 30m /h Ql = 40m /h DH40-FA Discharge Pressure 6 bar 5 bar 4 bar 3 bar Ql = 50m /h Ql = 60m /h Ql = 70m /h 2 bar 1 bar 0 bar 0.0 m /h 2.0 m /h 4.0 m /h 6.0 m /h 8.0 m /h 10.0 m /h 12.0 m /h 14.0 m /h 16.0 m /h 18.0 m /h 20.0 m /h Displacement 6

Available Accessories DEPA AirSave System Diaphragm leakage monitoring system Stroke Counter Innovative and robust design: Increases energy efficiency and service life of the pump. The DEPA AirSave System delivers outstanding performance, operating at a low start-up pressure with virtually no leakage. The economic operation of the pump: Provides ease of maintenance, low cost operation, reduces maintenance downtime and spare parts inventory, and increases plant capacity. Available for use in a broad range of applications: In all DEPA pumps sizes (DH15/25/40 and DEPA Series P, Non-Metallic), for ATEX compliant applications, the air valve is also available In case a diaphragm failure occurs, the pumped medium enters the air chamber and triggers the sensor. The sensor sends subsequently an electrical output to the monitoring device for evaluation of the signal. The control unit switches of the air supply to the air valve and thus halting the operation of the pump. Two sensors per pump (one per chamber) are installed. Two types of sensors are available: Conductivity Measurement, Standard (orange) for conductive products Capacity System, ATEX (blue) for non-conductive products and approved for ATEXcertified pumps. Please note, that both types of sensors are only available from pump size 25 upward. The stroke counter sensor counts each cycle of the diaphragm movement. Multiplying the number of cycles with the pump chamber volumes, the discharge flow rate can be determined. For dosing applications, the stroke counter provides for precise measurement and accurate regulation. The stroke counter sensor is located within the center block and provides an electrical output each time the diaphragm is in the end position. The stroke counter consists of a sensor and an electronic amplifier/ regulator. the sensor can be used in ATEX certified pumps. 7

Crane ChemPharma & Energy Crane Process Flow Technologies GmbH Postfach 11 12 40, D-40512 Düsseldorf Heerdter Lohweg 63-71, D-40549 Düsseldorf Tel.: +49 211 5956-0 Fax.: +49 211 5956-111 www.flowoffluids.com brands you trust. CPE-DEPA-DH-BU-EN-A4-MX-2014_03_01 Edition 03/2014 Crane Co., and its subsidiaries cannot accept responsibility for possible errors in catalogues, brochures, other printed materials, and website information. Crane Co. reserves the right to alter its products without notice, including products already on order provided that such alteration can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the Crane Co. or its subsidiaries. The Crane and Crane brands logotype, in alphabetical order, (ALOYCO, CENTER LINE, COMPAC-NOZ, CRANE, DEPA, DUO-CHEK, ELRO, FLOWSEAL, JENKINS, KROMBACH, NOZ-CHEK, PACIFIC VALVES, RESISTOFLEX, REVO, SAUNDERS, STOCKHAM, TRIANGLE, UNI-CHEK, WTA, and XOMOX ) are registered trademarks of Crane Co. All rights reserved. 2014 Crane ChemPharma & Energy