Silent compressor for laboratory ( Item Code F )

Similar documents
VERTICAL AIR COMPRESSORS

Budget Range Operators Handbook

Code AWC20HP Air Compressor

VERTICAL AIR COMPRESSORS

PT Range Operators Handbook PT models

80 Litre Suction Oil Drainer

Operating Instructions Part No

Budget Range Operators Handbook

Waste Oil Extraction Unit

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Instruction Manual. LKHSP Self-Priming Centrifugal Pump (Appendix) ESE02222-EN

1 DRIVE INDUSTRIAL IMPACT WRENCH

Portable Oil Lube Air Compressors

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

SILENTAIRE TECHNOLOGY

24 Litre Air Compressor

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

SILENTAIRE TECHNOLOGY

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Operating Instructions Part No

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

100C Air Compressor Kit

200 PSI FAST-FILL AIR SOURCE KIT

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

200 PSI COMPRESSORS - MODEL NUMBERS

200L BELT DRIVEN AIR COMPRESSOR

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI HIGH-FLOW AIR SOURCE KIT

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

COMPRESSOR MANUAL. (888)

MD R a n g e O p e r a t o r s H a n d b o o k

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

CAST IRON SAFETY VALVE TYPE 6301

Operating manual for Material pressure tanks Vol./1 and Vol./2

TURBO SET 1000 E D $'9 5(9

MF2M Monnier Miniature Compressed Air Filter

VACUUM REGULATORS CONTENTS

[Graphic Division] 10

444C DUAL PERFORMANCE VALUE PACK

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

IMPORTANT SAFETY INSTRUCTIONS

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

MANUAL. Sesame. Thermoplastic Tank Technologies

STAGE, STADIUM & X-TREME SHOT.

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Hercules Space Saver Sole Press series

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Pressure switches for air and water CS

30T A/Manual Hydraulic Shop Press

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Model ASSEMBLY and OPERATING INSTRUCTIONS

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Safety instructions and operating manual

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Setup Guide for your HVO Naked Drone

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

ML3M Monnier Miniature Compressed Air Lubricator

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Pulsar/S Use & Maintenance manual

AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Magnetic level switch type MR783 Instruction Manual

BOSS PULISCI PROVA IMPIANTI MEDIA

Dri-Line Mk3 Monnier Compressed Air Drain Trap

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

GRAPHIC DIVISION. 3D drawings available at

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Holugt Portable Unit HL120 Electric

SIHI LPH-X - Liquid Ring Compressors

Liquid ring vacuum pumps in compact design

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

VIESMANN. Service instructions VITOSOL 200-T, 300-T. for contractors. Vitosol 200-T, 300-T. For applicability, see the last page

Transcription:

www.cif.fr Silent compressor for laboratory ( Item Code F41 045 ) INSTRUCTIONS MANUAL This document contains manufacturer sinformation, protected through copyright. All rights reserved. This document can not be copied, reproduced or translated without written agreement from C.I.F Information contained in this document can be modified without any prior notice CIF 1 / 16

EC Conformity Declaration We, C.I.F Circuit Imprimé Français 11 rue Charles Michels 92227 Bagneux Cedex France Tel 33 01 45 47 48 00 FAX 33 01 45 47 16 14 email : cif@cif.fr - web : www.cif.fr certify under our responsibility that this product conforms to European Economic Community standards : SILENT COMPRESSOR In conformance With European guidelines, (89/392/CEE 89/336/CCE) and to EN60-204-1 standard (F) Déclaration du constructeur La société C.I.F. 92220 BAGNEUX, France, certifie que le produit répond bien aux directives de la Communauté Economique Européenne. (GB) Manufacturer declaration : C.I.F. company 92220 BAGNEUX, France, herewith declare that this product conforms to E.E.C. regulations. (D) Hersstellererklärung : Hiermit erklärt die Firma C.I.F. S.A. 92220 BAGNEUX, France dass dieses produkt der Richtlinie EWG entspricht. Conforms to the following standards In accordance with the following European Decrees : Directives 73/23/EEC for low voltage machines amended by 93/68/EEC Directives 98/37 EC for Machines Directives EMC 89/336/EEC amended by 92/31/EEC and 93/68/EEC Bagneux, May 2005, Authorised signature CIF 2 / 16

Table of content TABLE OF CONTENT...3 1. PRESENTATION...4 1.1 TECHNICAL CHARACTERISTICS...4 2. TRANSPORT...5 3. SAFETY...5 4. MACHINE INSTALLATION...5 5. START UP...7 5.1 INSTRUCTIONS FOR USE...7 5.2 PRESSURE ADJUSTMENT...8 5.3 USE LIMITS IN CONTINUOUS FUNCTIONING...9 5.4 CONTROL OF FILLING TIME...10 6. MAINTENANCE...10 6.1 REGULAR MAINTENANCE....10 6.2 OIL REPLACEMENT...11 7. MAINTENANCE...12 7.1 SPECIAL INFORMATION...14 7.1.1 Compressor demolition...14 7.1.2 Curves sucked air/pressure volume...14 8. NOMENCLATURE...14 8.1 ELECTRIC SCHEME....14 8.1.1 Spare parts....15 8.1.2 Guarantee...15 9. APPENDIX...15 CIF 3 / 16

1. Presentation Silent compressor for laboratory Dedicated to the silent production of compressed air for needs up to 17 litres/min. Is suitable for areas where noise level is very important: laboratory, education, research centre etc. Delivered with quick coupling s kit and air filter. 1.1 Technical characteristics Power supply: Power: Capacity: Production: Max. pressure: Sound level: Net weight: Dimensions: 220 V AC, 50/60 Hz 135 W 1 litre 25 litres / min 6 bars 30 db 12 Kg 21 x 46 x 53 cm Noise lower than 70 db (A) No needs of special installation. CIF 4 / 16

2. Transport The compressors must be moved with precaution, eventually using transpallet. 3. Safety Sitted working no needs of special installation. Do not use the compressor for another use it is conceived for. Keep the compressor in a covered area and from rain and humidity. Use the compressor in a ventilated area only. During use, keep the compressor out of children reach, and in general way, never let it unattended. Do not direct compressed air to people. In case of flammable liquids sprays, there is a risk of fire or explosion, above all in closed areas: well ventilate. Use without any precaution can cause fire. Do not use in explosion proof atmosphere. Do not repair the compressor when it is plugged or when the tank is under pressure. CAUTION! The safety valve is adjusted and sealed by the manufacturer. DO NOT MODIFY THE ADJUSTMENT. During use, the unit motor/tube reaches high temperatures. When we work near those components, avoid contacts as they can cause burns. The heat can be given to flammable materials you can not see. Non respect of those recommendations can damage people or the compressor. 4. Machine installation Install the compressor on a flat area, in a well ventilated, well dimensioned and non humid area, with a temperature up to 35 C at the maximum. If the ventilation is enough, install a well dimensioned vacuum cleaner or a ventilator. CIF 5 / 16

SILENT COMPRESSOR for LABORATORY Version 0507 CAUTION! THE COMPRESSOR IS DELIVERED WITHOUT OIL. In order that during transport the oil do not enter into compression chambers which can cause a bad functioning of the equipment. Get off the rubber cap off the suction tube, remove the suction filter and the spout from the nylon pocket, screw the spout on the oil bottle. Fill in up to the maximum level, as indicated on the light. Oil level must never be up to the maximum level. Only use recommended oil, in order to keep the guarantee. Keep remaining oil for future uses. CIF 6 / 16

Set again the suction filter in the tube pressing on it. FILTER After this operation you must not turn over or incline the compressor, to avoid loosing oil. The power supply must be the same as indicated on the motor: 230V/50Hz (115V/60Hz). The plug must be 2 poles + ground. 5. Start up 5.1 Instructions for use Always use the compressor on a flat area. The switch on is the pommel placed on the cover of the pressure controller. Push the pommel of the pressure controller up to position "0" Plug and switch on the compressor drawing the pressure controller pommel up to position "1 ". Functioning is automatic. CIF 7 / 16

The pressure controller stops the compressor when the pressure in the tank reaches the maximum value (8 bar 120psi standard), and star tit again when the pressure decreases to the minimum value (6 bar 90psi standard). Adjust the air pressure at the outlet thanks to the pommel of the reducer filter. The pressure is indicated on the manometer near the regulator. 5.2 Pressure adjustment 1. Adjustment of the maximum pressure (stop) The maximum pressure must be adjusted thanks to the 2 screws " A " et " B " View of the pressure controller Turn the 2 screws " A " et " B " to the right to increase the pressure. 2. Adjustment of the differential pressure (start). The differential pressure can be adjusted thanks to the screw " C ". Turn the screw " C " in the right way to reduce the differential pressure. CIF 8 / 16

Caution The operation of pressure adjustment must be done by a dedicated staff. In case of bad functioning of the pressure controller (overpressure), the safety valve automatically opens when the pressure is over the maximum adjusted pressure. 5.3 Use limits in continuous functioning. The curve 1 indicates the continuous functioning time, with variable pressures, before the protective thermic relay of the motor switches off the compressor (motor temperature about 115 C). These times are calculated from the starting with a temperature of 20"C. Example: 6 bar= 116 minutes. The curve 2 indicates the recommended proportion between using and stopping time. Example: at 4 bar advised functioning time is 76%, relevant to a use of 46 minutes for 14 stopping minutes per hour. The curves represent average values at 230V150Hz, with a temperature ambiante of 20 C. CIF 9 / 16

5.4 Control of filling time. Control the compressor according to the following instructions: 1. Empty the tank of compressed air. 2. Closed the compressor outlet on the tank and control the draining tap is closed. 3. Switch on the compressor and control the time between the start and tha automatic stop. (25 seconds for this model). 4. Verify there is no escape from the couplings. 5. Verify the maximum pressure = 8bars/120Psi. 6. Maintenance 6.1 Regular maintenance. CAUTION Those hereunder operations must be done by specialise staff only. Once a week Once a month Once a year Control oil level once a week. When the motor stops, the oil level you see through the light must be the same as the one indicated on the board. Drain the water of the filter reducer as shown fig. 6 (the operation must be done with the tank under pressure). X X Drain the condensation water of the air tank. For that, switch on the compressor, put it in an area where air can not damage the ground, unscrewing the draining tap at the tank base. Control the good functioning of the compressor: possible unscrewing of the couplings, use of the pressure tubes, screwing, electric part good functioning, etc. Control the air suction filter. Replace the filter when it is stopped. Clean the compressor with a soft rag. The dust prevents the coolness. Dismantle and clean the cartridge with coalescence of the filter (Fig.8) blowing with compressed air. This operation must be done when the tank is completely under pressure. Control the filter reducer an dits components for optimisation. Control the safety valve (fig 9) softly drawing the pressure ring of the tank. Complete replacement of the oil. X X Every 3 months X Every 6 months X X X CIF 10 / 16

6.2 Oil Replacement. Proceed as shown Fig.10. 1. Dismantle the motor group if necessary. 2. Get the cover off unscrewing the 4 vices. 3. Incline the motor group (without turning it over) maintaining the internal block at its place with the hand. 4. Empty oil Nota! Used oil must be recycling according to the rules in force. 5. Control the cover gasket. 6. Replace the cover and during this operation control the gasket is well positionned to ensure a good closing at 100% between the box and the cover. 8. Assemble the motor group upon the tank. IMPORTANT Always use oil «ROLOIL-SINCOM/32» as other types of oil can mechanically damage the compressor. As a consequence, the guarantee will be valid only with the relevant oil. CIF 11 / 16

7. Maintenance CAUTION Unplug before any intervention. Completely empty the air tank, before dismantling some component. Each operation must be exclusively done by specialised staff. 1- The compressor does not start 2- The compressor works but does not reach the maximum pressure 3- The compressor starts but the pressure in the tank does not increase (or softly increases). 4- The compresseur works but does not charge. a) There is no power in the electrical network. Verify the fuses and the plug. b) Broken or damage of electrical connections. Control the continuity thanks to a tester acording to electrical schemes. c) The tank is under pressure. The compressor only starts when the pressure is upper than the adjusted minimal value of the pressure controller. d) Loss on the non-return valve. Dismantle the flexible tube and verify if air escapes from the valve. In case of escapes, unscrew the valve head (Fig. 11 pos. 1) and carefully clean the rubber tap (pos. 2) (thanks to a soft rag); then assemble the whole taking care. In case of the escape continues, totally replace the valve. e) Starting relay does not work: Contact the distributor. a) Bad condensator. Replace it. g) The thermic relay stops the compressor because of over heat. When it is getting cold, the compressor will automatically start again at the good temperature. a) Verify ther is no air escapes (See point 6). b) Control the nice functioning of the pressure controller and adjust it i necessary ( page 8 Pressure adjustment). c) Non return valve is bad (or blocked) and causes a air loss. Replace the valve. a) The circulation tap is not get off the air suction tube (or the hole). b) The air filter is blocked. Clean or change the filter. c) Verify there is no air escapes (Voir 6). The problem can be caused by the broken valves or gaskets (Fig.12). Immediately proceed to the replacement of the damaged piece. CIF 12 / 16

Fig.12 5- The compressor stops during use. The motor is equipped of a protective thermic relay with automatic rearmament which stops the compressor when the temperature reaches too high values. The compressor starts again after 15/20 minutes. 6- Air loss Can be caused because of a bad sealing of some coupling. Control each coupling cleaning them with sopa water. 7- Loss upon valve situated under the pressure controller 8- The compressor starts and stops most frequently than usual. 9- The compressor does not start when the pressure is under the minimal value and/or does not stop when the maximum pressure is reached. 10- The compressor heats too much and use too much oil. The valve is damaged, replace it. The problem can be caused by a bad sealing of the non return valve (See 1d). a) In the tank there is a big quantity of condensate. Drain the tank letting the condensate go. b) Air loss (See 6). The pressure controller is bad. Replace it. a) Oil level is too high. b) Used oil of the compressor is not the right one. Only use the recommended oil by the supplier. c) Air loss (See 6). d) Air filter is blocked. Clean or replace the filter. e) The air temperature is too high. Never install the compressor inside the box unless there is a nice aeration. f) The compressor is over weighted. Ensure the compressor you use suits to your needs. CIF 13 / 16

7.1 Special information. 7.1.1 Compressor demolition. During the compressor demolition, all safety standards must be respected to avoid hurt staff or damage the equipment. The metallic parts should be thrown away to reinforce; the rubber and plastic parts should be eliminated according to the standards in force. 7.1.2 Curves sucked air/pressure volume. 8.Nomenclature 8.1 Electric scheme. CIF 14 / 16

8.1.1 Spare parts. The wrong part replacement must exclusively be done by specialised staff, respecting safety standards to avoid damaging staff and equipment. To order spare parts, you need: Give the compressor serial number and the year. Give the requested quantity. CAUTION The non -respect of the safety standards can cause severe problems to people or damage equipment. The manufacturer can not be held responsible in case of damages due to a bad use of the compressor. 8.1.2 Guarantee. The compressor is guaranteed 12 months. The guarantee is only dedicated to free replacement of wrong parts recognised by the manufacturer. The electric parts subject to use are non inclusive. The deterioration or bad use of the compressor cancels the guarantee. Freight charge are not included into the guarantee. 9.Appendix CIF 15 / 16

www.cif.fr CIF 16 / 16