PP-1, PP-1W, PP-2, & PP-3

Similar documents
Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Constant Pressure Crude Oil Container Model CPCCP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP ACE CRUDE OIL SAMPLER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER COMPOSITE GAS SAMPLER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

TITAN FLOW CONTROL, INC.

BUTTERFLY VALVES Series 800

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

GILMONT ACCUCAL FLOWMETERS

LRS(H)4 Pressure-Reducing Regulator User Manual

FLANGED TWO-PIECE BALL VALVES

RD(H)20/25 Pressure-Reducing Regulator User Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

FLANGED TWO-PIECE BALL VALVES

Installation, Operation & Maintenance Manual

2 Sentry MCL Installation, Operation & Maintenance

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

WHEATLEY Series 822/820 Swing Check Valve

1700ESL Kamvalok Coupler

WKM Model 320F Floating Ball Valve

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE SAMPLE CONTAINER

Instructions for Installation, Operating and Maintenance

WHEATLEY Series 500 Swing Check Valve

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

KECKLEY. Installation, Operation, and Maintenance Manual. Style KGV - Knife Gate Valve

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Installation, Operation & Maintenance Manual

FLANGED MULTI-PORT BALL VALVES

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

2 Sentry MVS Installation, Operation & Maintenance

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Adjustable. Unloader Valve. O&M Manual. Part #

Combination Air Valve

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Models: C62/63/64-A/D

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Float Operated Level Controllers

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

DelVal Flow Controls Private limited

Model GPR Primary Pressure Regulating Valve. Instruction Manual

HIGH RATE BASKET STRAINER

1200B2 Series Service Regulators. Instruction Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, Operation & Maintenance Manual

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Pressure Dump Valve Service Kit for Series 2300 Units

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

FloWash. Industrial Filter Cart

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation/Care/Use Manual

5 Channel Calibrator

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Hygienic Bubble Trap Installation and Operations Manual

Pressure relief valve

J Air and Water Kit Instructions Part# 02584

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Type CT88 Backpressure Regulator

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Aluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Regulator. Instructions for Use

1 DRIVE INDUSTRIAL IMPACT WRENCH

MUELLER. Xp, & Lineseal 350 Butterfly Valves

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Carter Option X Valve connector assembly. Maintenance manual

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

GI Series Diaphragm Pressure Gauge Guard

Installation, Operation & Maintenance Manual

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Transcription:

Welker Pitot Probe Model PP-1, PP-1W, PP-2, & PP-3 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance of the Welker equipment described above. Correct operating and/or installation techniques, however, are the responsibility of the end user. Welker reserves the right to make changes to this and all products in order to improve performance and reliability. 13839 West Bellfort Sugar Land, TX 77498-1671 (281) 491-2331 - Office (800) 776-7267 - USA Only (281) 491-8344 - Fax http://www.welkereng.com Copyright 2009, Welker, Inc.

TABLE OF CONTENTS 1. GENERAL 3 1.1 INTRODUCTION 3 1.2 DESCRIPTION OF PRODUCT 3 1.3 IMPORTANT INFORMATION 4 1.4 SPECIFICATIONS 4 1.5 SYSTEM DIAGRAM 5 2. INSTALLATION & OPERATION 6 2.1 GENERAL 6 2.2 INSTALLATION OF PROBE WITH FLANGE CONNECTION 6 2.3 INSTALLATION OF PROBE WITH NPT CONNECTION 7 2.4 OPERATION 7 3. MAINTENANCE 8 3.1 GENERAL 8 3.2 MAINTENANCE 8 4. TROUBLESHOOTING 9 4.1 TROUBLESHOOTING GUIDE 9 Welker, Welker Jet, and WelkerScope are Registered Trademarks owned by Welker, Inc. IOM-101 Page 2 of 10

SPECIFICATIONS 1. GENERAL 1.1 INTRODUCTION We appreciate your business and your choice of Welker products. The installation, operation, and maintenance liability for this product becomes that of the purchaser at the time of receipt. Reading the applicable Installation, Operation, and Maintenance (IOM) Manual prior to installation and operation of this equipment is required for a full understanding of its application and performance prior to use.* If you have any questions, please call 1-800-776-7267 in the USA or 1-281-491-2331. Notes, Warnings, and Cautions Notes emphasize information or set it off from the surrounding text. Caution messages appear before procedures that, if not observed, could result in damage to equipment. Warnings alert users to a specific procedure or practice that, if not followed correctly, could cause personal injury. *The following procedures have been written for use with standard Welker parts and equipment. Assemblies that have been modified may have additional requirements and specifications that are not listed in this manual.* 1.2 DESCRIPTION OF PRODUCT Welker Pitot Probes (PP-1 & PP-2) are designed to extract a sample of the fluid in a process from a designated point, create a flow loop through an instrument, and return to the pipeline via the same probe. The PP-1 series pitot probe is supplied as a probe with a specified process connection. The PP-2 series pitot probe is a PP-1 series sample probe with outlet (P1) and return (P2) valves. The PP-3 series pitot probe is a PP-2 series sample probe with two ball valves. IOM-101 Page 3 of 10

SPECIFICATIONS 1.3 IMPORTANT INFORMATION For accurate sampling results, probe should not be installed in a header or blow-down stack and should be away from obstructions, elbows or partially closed valves. 1.4 SPECIFICATIONS The specifications listed in this Section are generalized for this equipment. Welker can modify the equipment according to your company s needs. However, please note that the specifications may vary depending on the customization of your product. Materials of Construction: Maximum Allowable Operating Pressure: Pipeline Connection: Outlet Ports: Products Sampled: Table 1 Specifications PTFE, Stainless steel and Viton with others available. MAOP will vary according to customer specifications of probe, please see assembly drawing for product, or contact Welker for this information. Flanged or NPT ¼" NPT with others available Non-Toxic natural gas or other gases or liquids compatible with the materials of construction. IOM-101 Page 4 of 10

SPECIFICATIONS 1.5 SYSTEM DIAGRAM Figure 1 Refer to diagram throughout this manual. IOM-101 Page 5 of 10

INSTALLATION & OPERATIONS 2. INSTALLATION & OPERATION INSTRUCTIONS 2.1 GENERAL After unpacking the unit, check it for compliance and for any damages that may have occurred during shipment. Claims for damages caused during shipping must be initiated by the receiver and directed to the shipping carrier. Welker is not responsible for any damages caused from mishandling by the shipping company. 2.2 INSTALLATION OF PROBE WITH FLANGE CONNECTION (Refer to Figure 1 on page 5 & Figure 2 below) Before installing the probe, make sure that the pipeline is depressurized. 1. Use the appropriate size gasket and position it properly for the connection being used. 2. Mount the probe to the mating flange connection on the pipeline. (If the sample probe is a wafer style (PP-1W see Figure to right), then mount the probe between the correct mating flanges on the pipeline.) 3. Install the bolts and nuts to the flanges. 4. Tighten the nuts to the proper torque specification for the particular flange size. 5. Close the valve on the probe. 6. Pressurize the pipeline and check for leaks. 7. The probe is now in service. Figure 2 Waffle Style Pitot Probe PP-1W IOM-101 Page 6 of 10

INSTALLATION & OPERATIONS 2.3 INSTALLATION OF PROBE WITH NPT CONNECTION (Refer to Figure 2) Before installing the probe, make sure that the pipeline is depressurized. When sealing fittings with PTFE tape, refer to the proper sealing instructions for the tape used. 1. Mount the probe to the mating NPT connection on the pipeline. 2. Tighten the probe to the proper NPT depth gauge. 3. Close the valve on the probe. 4. Pressurize the pipeline and check for leaks. 5. The probe is now in service. 2.4 OPERATION Figure 2 NPT Style Pitot Probe PP-2 1. The only operation of the probe is to open and close the valve as needed when the appropriate equipment is connected to it. IOM-101 Page 7 of 10

MAINTENANCE 3. MAINTENANCE 3.1 GENERAL Prior to maintenance or disassembly of the unit, it is advisable to have a repair kit handy for the system in case of unexpected wear or faulty seals. All maintenance and cleaning of the unit should be done on a smooth, clean surface. 3.2 MAINTENANCE Recommended Tools It would be advisable to have the following tools available for maintenance of the unit: Two adjustable wrenches (size of wrenches will depend on customer specifications of probe). 1. Maintenance needs to be performed to a probe only if the probe valve is leaking. 2. Depressurize the pipeline before performing any maintenance on the probe. 3. Close the probe valve. 4. Remove any equipment that is attached to the probe valve. 5. Remove the probe valve from the probe. 6. Rebuild or replace the probe valve. 7. Reattach the probe valve to the probe. 8. The probe is now ready for service. IOM-101 Page 8 of 10

TROUBLESHOOTING 4. Troubleshooting Guide The following is a troubleshooting table of issues most commonly associated with the Welker Pitot Probe models. If you are having a problem that is not listed, or if the solution provided does not repair the problem, please call Welker for service options. PROBLEM POSSIBLE CAUSE SOLUTION Valve Leaking Debris in valve Worn or damaged O-rings and seat Disassemble Valve and clean and replace O-rings if needed. (See Section 3.2 maintenance for instructions). Replace Valve IOM-101 Page 9 of 10

13839 West Bellfort, Sugar Land, Texas 77498-1671 Phone: (281) 491-2331 Fax: (281) 491-8344 Toll Free: (800) 776-7267 Web Page: www.welkereng.com