Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Similar documents
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Valve Proving System VDK 200 A S02

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Pressure Switch for DMV safety shutoff valves

Valve Proving System VDK 200 A S06*

Gas Pressure Switch for DMV safety shutoff valves

SPECIFICATIONS ATTENTION

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Pressure switch for gas and air

Butterfly Control Valve. DMK/6 Series

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Pressure Switch for gas and air

Pressure Switch for gas and air GGAO-A4

Gas Pressure Switch for DMV safety shutoff valves

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

Ratio Regulator Zero Governor. FRG/6 Series

SPECIFICATIONS CAPACITY

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

SPECIFICATIONS ATTENTION

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

Commonwealth of Massachusetts Approved Product Approval code G

Pressure Switch for gas and air

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Commonwealth of Massachusetts Approved Product Approval code G

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

Old documentation - Only for your information! Product is not available anymore!

FRS 7../6 series are CSA Certified: ANSI Z21.80 / CSA 6.22 Class I. Commonwealth of Massachusetts Approved Product Approval code G

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VMR VMR-OTN VMR 6 bar

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

RR 16 Commercial & Industrial Regulator

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

Slam Shut Valves SCN

Compact pressure switches for gas and air

GM Series Dual-Block Multi-Function Gas Control Valves

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

RR 16 Commercial & Industrial Regulator

Dual Solenoid Gas Valve Installation

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Gas Pressure Regulator HON 200

BGA158 Series CE Approved Class A Shutoff Gas Valve

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Tightness controls TC 1 3 and TC 4

BGA158 Series CE Approved Class B Shutoff Gas Valve

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

O.K. Safety first USA CDN. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA. MBC-VEF 1000/2500/4000 GasMultiBloc

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

GM-7000 Series CE Approved Gas Control Valve

4/2 way Pneumatic Solenoid Valve

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

Combined Pressure / Vacuum Relief Valve KITO VD/o

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA. MBC-SE 1000/2500/4000 GasMultiBloc

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Double gas valves for biogases and recycling gases

Slam Shut Valves SBC 782

2/2-Way Solenoid Control Valve

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

ASX 176 Axial Pressure regulator

Gas Pressure Regulator HON 300

North American Pressure Switches

Type 4708 Supply Pressure Regulator

Transcription:

Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I File # 1506 FM Approved Class 11 File # J.I. 300653 Commonwealth of Massachusetts Approved Product Approval code G1-110-35 Gas Safety Shutoff Valve EU Gas Appliance Directive EN161 CE-00AU30 Codes and Standards: This product is intended for installations covered by but not limited to NFPA 6, NFPA 3, or CSA B19.3. DUNGS is an ISO 9001 manufacturing facility. Description The DUNGS Dual Modular Valve (DMV) combines two safety shutoff valves in one compact housing, which can be wired independently or in parallel. Directly mounting the following DUNGS accessories creates a compact valve train without additional piping: - High and low gas pressure switches - Valve proving system DMV ISO FLANGED Sales Brochrue - P/N 22 955 - Ed 01/09 1 6 Valve 1 (V1) of the DMV-D and DMV-DLE series is fast opening and fast closing. Valve 2 (V2) of the DMV-D is fast opening, while V2 of the DMV-DLE is slow-opening for smoother light-off. Max. flow adjustment on V1 provides variable main flow on both models. Internal profiles and compact design optimize flow and provide a low pressure drop. Application The DUNGS DMV is recommended for industrial and commercial heating aplications that require two safety shutoff valves. The DMV Dual Modular Valve is suitable for natural gas, propane, butane, air and other inert gases. Suitable for up to 0.1% by volume, dry H 2 S.

DMV-D /11 Two normally closed safety shutoff valves in one housing. V1 and V2 are fast opening, fast closing. Adjustable max. flow with V2. DMV-DLE /11 Two normally closed safety shutoff valves in one housing. V1 fast opening, fast closing. V2 is slow opening, fast closing. Adjustable max. flow and adjustable initial lift with V2. Specifications Flange sizes Max. operating pressure Max. body pressure Max. close off pressure Electrical ratings (+10% / -15%) Power rating for Coil Type 1212 Coil Type 1212 Coil Type 111 Coil Type 1511 Coil Type 1611 Coil Type 111 Enclosure rating Electrical connection Operating time Closing time Opening time (to max. flow) Initial lift adjustment Max. flow adjustment DN 0 ( 1 1/2") 50 (2") 65 (2 1/2") 0(3") (") 125 (5") Connection flange as per DIN 2501 Part 1, to fit pre-weld flanges as per DIN 2633 (PN 16) DN 0 to DN 125, ISO 005-1 (PN 16), or ISO 005-2 (PN 16). PSI (500 mbar) FM, CE (Class A) 5 PSI (360 mbar) CSA 15 PSI (0 mbar) PSI (500 mbar) FM, CE (Class A) 5 PSI (360 mbar) CSA 110-120 VAC/50-60 Hz and 2 VDC. Part numbers listed on page 3. - VAC/50-60 Hz and 2 VAC/ 50-60 Hz models available upon request Version Approx. rating [VA] Approx. operating current [A] DMV-D(LE) 500/11 90 0. A @ 120Vac/3. A @2Vdc DMV-D(LE) 5050/11 90 0. A @ 120Vac/3. A @2Vdc DMV-D(LE) 5065/11 110 0.92 A @ 120Vac/.6 A @2Vdc DMV-D(LE) 500/11 110 0.92 A @ 120Vac/.6 A @2Vdc DMV-D(LE) 5/11 135 1.12 A @ 120Vac/ A @2Vdc DMV-D(LE) 5125/11 200 1.6 A @ 120Vac/.3 A @2Vdc NEMA Type 12 DIN-connector with 1/2 NPT conduit adapter % duty cycle < 1 s DMV-D /11 V1 & V2 < 1 s DMV-DLE /11 V1 < 1 s; V2 Adjustable to approx. 10 to 20 s at 0 F Adjustable on V2 DLE only; 0 to 0 % of total flow; 0 to 25% of stroke Adjustable on V1 <10 to % of total flow; <10 to % of stroke Materials in contact with gas Housing: Valve seats: Aluminum & Steel free of non-ferrous metals NBR-based rubber Ambient temperature rating Installation position Gas strainer (standard) Position indication (order separately) Test ports / Pressure switch mounting ports Valve proving system +5 F to +10 F (-15 C to +60 C) Safety valve upright to lying horizontally Installed in the housing upstream V1 (23 mesh) CPI 00 with indication lamps and SPDT interlock switch or Visual indicator (VI) G 1/ ISO 22 ports available on both sides. Each side has two ports upstream V1, one between V1 and V2, one downstream V2. G 1/ ISO 22 on both flanges, upstream of V1, downstream of V2 VPS 50; mounts directly to either side of DMV. 2 6

Dimensions inch (mm) Type 110-120 VAC 50-60 Hz Order No. 2VDC Order No. p max. [PSI] Connection DN Dimensions [inch] Dimensions [mm] a b c e f Weight [lbs] Weight [kg] DMV-D 500/11 DMV-D 5050/11 DMV-D 5065/11 DMV-D 500/11 DMV-D 5/11 DMV-D 5125/11 226-061 226-06 226-06 226-00 226-03 226-06 226-063 226-066 226-069 226-02 226-05 226-0 DN 0 DN 50 DN 65 DN 0 DN DN 125 11. 290 12.2 310 13. 350 15. 00 2.5 62,5 2.9 3 3..1 10. 119 12.6 192.6 192 9.9 251 11.5 293 13.0 331 16.2 12.0 102 5.1 129 13 6.3 161 5.9 150 6.5 165.3 15.9 200. 10.0 255 1.2. 1.3.3 32.2 1.6 52.0 23.6 6.5 30.6 111.6 50.6 3 6 DMV-DLE 500/11 DMV-DLE 5050/11 DMV-DLE 5065/11 DMV-DLE 500/11 DMV-DLE 5/11 DMV-DLE 5125/11 226-115 226-11 226-102 226-10 226-112 226-10 226-11 226-120 226-103 226-106 226-11 226-110 DN 0 DN 50 DN 65 DN 0 DN DN 125 11. 290 12.2 310 13. 350 15. 00 2.5 62,5 2.9 3 3..1 10. 119 12.. 10.6 269 12.3 312 15.1 32 1.2 62.0 102 5.1 129 13 6.3 161 5.9 150 6.5 165.3 15.9 200. 10.0 255 1..9 1.5. 32.6 1. 53.1 2.1 6.6 31.1 112. 51.1

Equipment variants of DMV.../11 double solenoid valve, single-stage mode DMV-D DMV-DLE Sieve DMV 500/11 - DMV 5125/11 Gas pressure switch can be mounted: on flange downstream of sieve downstream of valve 2 Valve V1, double-seat Valve V2, double-seat Valves opening separately G 3/ ignition gas flange can be mounted Possible using a pipe nipple. () () () = standard () = on request -- = not possible DMV 5.../11 Flange Accessories Size *Weld neck part # # of Holes Bolt size **Bolt part # ***Seal part # DN 0 22-13 M16x55 135-90 -16 DN 50 22-13 M16x55 135-90 030-221 DN 65 22-139 099-0 DN 0 22-10 030-25 DN 22-11 030-30 DN 125 22-12 M16x5 1-30 030-312 DN 65 to 2 1/2"NPT 23-690 099-0 DN 0 to 3"NPT 23-219 030-25 *When a control is used alone, one mating flange is needed for each end, for a total of two flanges. When one control is bolted to another, such as an FRS to a DMV, one mating flange is needed for each end, for a total of two flanges ** includes one bolt, one lock washer, and one nut *** one seal needed for each flange 6

Dual Modular Valve (DMV) system Port 6 Port Min. gas pressure switch Valve switch Valve switch Max. gas pressure switch Valve proving system Additional Accessories VPS 50 Valve proving system (approved by some authorities having jurisdiction in lieu of vent valve and proof of closure e.g. FM and Swiss Re). GAO/GMH/GML A2 pressure switch Position indication CPI 00 with indication lamps and SPDT interlock switch, or Visual indicator (VI) DMK butterfly control valve Mounts directly downstream of DMV to modulate gas flow. Requires actuator. Use DMA actuator with DMK butterfly valve. Adapters 1/ NPT adapter (225-0) 1/2 NPT Pilot gas adapter; Check flow requirements. (225-03) G 1/ Test nipple (219-00) To determine the pressure drop when using a gas other than natural gas, use the flow formula below and f value located in the chart on the next page to determine the corrected flow rate in CFH through the valve for the other gas used. For example, when using propane, divide the volume (CFH) of propane required for the application by the calculated value f (f = 0.66 for propane). Use this corrected flow rate and the flow curve on the next page to determine pressure drop for propane. V gas used = V Natural Gas x f Type of gas used Density [kg/m 3 ] sg f Use this formula to calculator the f factor for other gases not listed on the table. Natural gas 0.1 0.65 1.00 f = Spec. gravity of Natural Gas Spec. gravity of gas used Butane Propane 2.39 1.6 1.95 1.50 0.5 0.66 Air 1.2 1.00 0.0 5 6

Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Flow curve 0,000 60,000 We reserve the right to make any changes in the interest of technical progress. Karl Dungs Inc. 52 Apollo Drive, Suite 10 Lino Lakes, MN 5501, U.S.A. Phone 651 92-912 Fax 651 92-919 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ Karl Dungs GmbH & Co. KG P.O. Box 12 29 D-3602 Schorndorf, Germany Phone +9 (0)11-0-0 Fax +9 (0)11-0-166 e-mail info@dungs.com Internet http://www.dungs.com 6 6