AUTO PUMP STATUS CENTER

Similar documents
Deep Submersible Level Transducer Series 300DS

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

DPC-30 DPC-100. Reference Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

GasSense NDIR User Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

444C DUAL PERFORMANCE VALUE PACK

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

400C & 450C DUAL PERFORMANCE VALUE PACKS

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

BUBBLER CONTROL SYSTEM

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Model 6812C Dual Lane Scoreboard Owner s Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

MODEL CALIBRATION GAS DELIVERY SYSTEM

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

480C DUAL PERFORMANCE VALUE PACK

BUBBLER CONTROL SYSTEM

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

210 Series Transmitter with External Electrochemical Sensor

RGC-IR Remote Gas Calibrator for IR400

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Model PSI Compressor with 3-Gallon Air Tank 12VDC

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

100C Air Compressor Kit

Marschalk Model # 94000

User s Guide. CO2 & O2 Controller for miniature incubators

HLM-2000-TX Gas Transmitter User Manual

Stand-Alone Bubble Detection System

IMPORTANT SAFETY INSTRUCTIONS

DeltaSpan General Purpose Water Small Bore or Wastewater Pressure Level Transmitter LD34 and LD35 Series Manual

User s Guide. Vacuum Controller for liquid delivery systems

HLM-2000-TX Gas Transmitter User Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

700 SERIES BMS II BUBBLER MONITORING SYSTEM

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

ASIC-Based Small Bore Submersible Level Transducer

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

Flowline, Inc Humbolt Street Los Alamitos, CA Tel: (562) Fax: (562) Rev B MN of 16

RAM 4021 Operation Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

ASDX Series Silicon Pressure Sensors

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Aquavar SOLO 2 Frequently Asked Questions

SDX Submersible Depth Transmitter User Manual

Oxygen Meter User Manual

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Additel 761 Automated Pressure Calibrators

SPECIFICATIONS ATTENTION

SC HYDRAULIC ENGINEERING CORPORATION

METEOR LSR0640 UNDERWATER POOL LIGHT. Operating Instructions

AutoChanger Installation & User Guide Issue 2

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

TH-1800-T TRX-700-CNG Converter

IMPORTANT SAFETY INSTRUCTIONS

Wireless Belt Pack BP Conductor with Radio Transmit

Wireless Belt Pack BP Conductor Jack with Radio Transmit & Volume Control

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Additel 761 Automated Pressure Calibrators Selection Guide

Modbus Submersible Level Transducer

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Additel 761 Automated Pressure Calibrators

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

User s Guide. CO2 Controller for miniature incubators

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

YOU MUST READ THIS MANUAL BEFORE USE

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

TR Electronic Pressure Regulator. User s Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Design Features. General Description

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

RAM Operation Manual

Additel 761 Automated Pressure Calibrators Selection Guide

DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

INSTRUCTION MANUAL. DIGIVAC Model 801 Series. Digital Vacuum Gauge. 801W Ranges to 760 Torr 1 to 9999 microns.001 to 999 millibar

INSTALLATION & MAINTENANCE INSTRUCTIONS

NOVALYNX CORPORATION MODEL ANALOG OUTPUT EVAPORATION GAUGE INSTRUCTION MANUAL

FLOW CONTROL & AIR PILOT SWITCH VALVES

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Transcription:

INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY

INTRODUCTION The Auto Pump Status Center is an air pressure sensor with indicator that displays air pressure in pounds per square inch (PSI). The indicator contains a numerical display and bar graph. The PSI indicator works in conjuction with an air pressure sensor. The air pressure sensor port can be connected to an air supply to measure and display PSI. The indicator is designed to be mounted on the exterior of a vehicle so that the PSI condition may be easily viewed. The indicator fits the Kussmaul standard indicator panel cut out. FEATURES I. AUTO PUMP STATUS CENTER Pressure sensor interface with 5/32 air supply input port 2.5-digit display 4-segment bar graph II. AIR SUPPLY A 5/32 air supply input port is used to connect air supply to the pressure sensor interface and a 1/8 NPT is provided for connecting to the air tank. III. PSI NUMERICAL DISPLAY A 2.5-digit display provides a PSI reading of the supplied air pressure. IV. BAR GRAPH The 4-segment bar graph is a graphical representation of the air supply condition. The bottom bar will flash if the supply pressure is below 50 PSI. All bars are illuminated when the pressure reaches 150 PSI. OPERATION The 091-198-12-AP consists of a pressure senor interface and an indicator to measure and display PSI. A bar graph on the indicator provides a graphical representation of the air supply condition. During operation, the pressure sensor continiously monitors the air supply present at the air input port. The pressure sensor then genarates an analog signal, which is then sent to the indicator. The indicator then convertes the analog signal to the digital display. A 2-pin terminal connector is used to supply power to the pressure sensor interface. Additionally, a 4-pin terminal connector is used to interface the indicator with the pressure sensor. The 4-pin terminal provides power and pressure sensor signal to the indicator. Whenever the monitored air supply drops below 50 PSI the bottom bar graph LED will flash indicating low pressure. The 4-segment bar graph is fully illuminated when the air supply reaches 150 PSI. 2

INSTALLATION INSTRUCTIONS I. MOUNTING THE AUTO PUMP STATUS CENTER 1. Mount the pressure sensor interface in a suitable location protected from moisture and excessive heat. 2. The indicator is designed to be mounted on the exterior of a vehicle so that the PSI condition may be easily viewed. II. WIRING THE AUTO PUMP STATUS CENTER 1. See Figure 1, Wiring the Auto Pump Status Center 2. Connect the air supply to the air pressure sensor input port using 5/32 tubing. A straight fitting, 1/8 NPT, is supplied for connecting to the air tank. 3. Connect DC input power to the 2-pin terminal. For continuous operation, supply continuous power to the pressure sensor interface. 4. Connect the indicator to the 4-pin terminal located on the pressure sensor interface. III. FIGURE 1, WIRING THE AUTO PUMP STATUS CENTER AIR PRESSURE SENSOR Model 091-198 POWER +12 V GND AIR 150 PSI MAX +12V OUTPUT GND SIG. +12V AUX. 1 2 1 2 3 4 RED (20AWG) ¼ AMP FUSE BLACK (20AWG) FROM AIR SUPPLY (5/32 TUBING) Note: recommended 20 AWG cable not supplied + - BATTERY 3

SPECIFICATIONS Input Voltage: 7-16 VDC (12 VDC nominal) Input Current: 100 ma, maximum Input Fuse: 250 ma (1/4 Amp) Air Supply: 150 PSI, max Hardware Pack Provided: (1) PLBPC4-01: Fitting, Straight, 1/8 NPT X 5/32 (36 ) WIR1B-201-10: Nylon, M 5/32 O.D. Tubing Weight:.5 pounds OUTLINE DRAWING 5.25 3/16" DIA. 3.00 4,75 1.50 INTERFACE 0.75 2.375 3.20 4.70 3.90 INDICATOR 4

OPTIONAL ACCESSORIES I. INDICATOR SEAL, MODEL #: 091-39-109 Provides a waterproof seal for the status center display. 5

INSTALLATION RECORD DATE INSTALLED INSTALLED BY VEHICLE IDENTIFICATION VEHICLE OWNER WARRANTY POLICY All products of Kussmaul Electronics are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Defective products should be returned to Kussmaul Electronics with shipping charges prepaid. Upon repair, products will be returned to customer with shipping charges paid. Kussmaul Electronics shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. 6