Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Similar documents
Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

1 Technical specifications

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

1 Technical specifications

1 Technical specifications

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

TYPE APPROVAL CERTIFICATE

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Transmitters for general requirements. SITRANS P DS III - Technical description

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pressure Measurement. Transmitters for general requirements SITRANS P DS III Technical description. 2/74 Siemens FI

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Pressure transmitter PASCAL Ci4

Differential pressure

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals

Multi Vision. Digital Transmitter 10/ EN

Flow Measurement SITRANS F X

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology

Torque Tube TB300 Digital Transmitters

OPTIBAR P 1010 C Technical Datasheet

ATM.1ST/Ex - High Precision Transmitter

Bourdon tube pressure gauge for diaphragm seals

Model 266MST Differential Model 266RST Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Technical Data. Dimensions

Model 261GR for gauge pressure Model 261AR for absolute pressure

SITRANS P measuring instruments for pressure

Differential Pressure Transmiter

ABB measurement & analytics data sheet. 266MST and 266RST Differential and absolute pressure transmitters

Model 266MST Differential Model 266RST Absolute. 2600T Series Pressure Transmitters. Engineered solutions for all applications

2600T Series Pressure Transmitter

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM/Ex - Analog Pressure Transmitter

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

1 Overview. Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure

Technical Data. Dimensions

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Pressure switch with bourdon tube

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

High-performance submersible pressure transmitter For level measurement Model LH-10

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Precision digital pressure gauge Model CPG1000

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Design Features. General Description

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition

Model 266HSH Gauge Model 266NSH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

Precision pressure sensor Basic version Model CPT6020

9700 Transmitter Submersible hydrostatic level transmitter

Hand-held pressure calibrator with integrated pump Model CPH6600

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Pressure Measurement. Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure. 2/34 Siemens FI

ATM - Analog Pressure Transmitter

Technical Data. Dimensions

Pressure Measurement

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

High-performance submersible pressure transmitter For level measurement Model LH-20

Programmable pressure and temperature transmitters PTM/RS485

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SITRANS P measuring instruments for pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Additel 780 Series Pressure Controller

Programmable pressure and temperature transmitters PTM/RS485

VG5 Supplementary instructions

High-performance submersible pressure transmitter For level measurement Model LH-20

sitrans p Operating Instructions (de/en) Edition 03/2004

Sales presentation. SITRANS P portfolio extension P310 P DS III P410

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

AT9000 Advanced Transmitter Differential Pressure Transmitters

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Model 266HSH Gauge Model 266NSH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

Flow Measurement SITRANS F X

Relative pressure transmitter type 520

Transcription:

Siemens AG 06 Technical specifications SITRANS P, DS III for differential pressure and flow Input Measured variable Differential pressure and flow Span (fully adjustable) or measuring range, max. operating pressure (in accordance with 04/68/EU Pressure Equipment Directive) and max. test pressure (pursuant to DIN 6086) HART PROFIBUS PA/ FOUNDATION Fieldbus Span Nominal measuring Max. operating pressure MAWP (PS) range Lower measuring limit Measuring cell with silicone oil filling Measuring cell with inert filling liquid - for process temperature -0 C < +60 C (-4 F < +40 F) - for process temperature 60 C < +00 C (max. 85 C for measuring cell 0 bar) (40 F < + C (max. 85 C for measuring cell 45 psi)) Upper measuring limit Start of scale value... 0 mbar 0.... kpa 0.4... 8 inh O... 60 mbar 0.... 6 kpa 0.4... 4 inh O.5... 50 mbar 0.... 5 kpa... 00 inh O 6... 600 mbar 0.6...60 kpa.4... 40 inh O 6... 600 mbar.6...60 kpa 6.4... 64 inh O 50... 5000 mbar 5...500 kpa 0... 000 inh O 0.... 0 bar 0.0... MPa 4.5... 45 psi.5... 50 mbar 0.... 5 kpa... 00 inh O 6... 600 mbar 0.6...60 kpa.4... 40 inh O 6... 600 mbar.6...60 kpa 6.4... 64 inh O 50... 5000 mbar 5...500 kpa 0... 000 inh O 0.... 0 bar 0.0... MPa 4.5... 45 psi 0 mbar kpa 8 inh O 60 mbar 6 kpa 4. inh O 50 mbar 5 kpa 00 inh O 600 mbar 60 kpa 40 inh O 600 mbar 60 kpa 64 inh O 5000 mbar 500 kpa 000 inh O 0 bar MPa 45 psi 50 mbar 5 kpa 00 inh O 600 mbar 60 kpa 40 inh O 600 mbar 60 kpa 64 inh O 5000 mbar 500 kpa 000 inh O 0 bar MPa 45 psi bar. MPa 464 psi 60 bar 6 MPa 0 psi 40 bar 4 MPa 609 psi (500 bar/50 MPa/750 psi can be ordered optionally with Order Code D56) -00 % of max. span (- % with measuring cell 0 bar/ MPa/45 psi) or 0 mbar a/ kpa a/0.44 psia -00 % of max. span (- % with measuring cell 0 bar/ MPa/45 psi) or 0 mbar a/ kpa a/0.44 psia 0 mbar a + 0 mbar a. ( - 60 C)/ C kpa a + kpa a. ( - 60 C)/ C 0.44 psi a + 0.9 psi a. ( - 08 F)/ F 00 % of max. span (for oxygen measurement max. 00 bar/0 MPa/450 psi and 60 C (08 F) ambient temperature/process temperature) Between the measuring limits (fully adjustable) Siemens FI 0 06 US Edition /55

Siemens AG 06 SITRANS P, DS III for differential pressure and flow Output HART PROFIBUS PA/FOUNDATION Fieldbus Output signal 4... 0 ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable).55 ma, factory preset to.84 ma - Upper limit (infinitely adjustable) ma, factory preset to 0.5 ma or - optionally set to.0 ma Load Without HART R B (U H - 0.5 V)/0.0 A in, - U H : Power supply in V With HART R B = 0... 500 (SIMATIC PDM) or - R B = 0... 00 (HART Communicator) Physical bus - IEC 658- Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0. s) Set to s (0... 00 s) Measuring accuracy Acc. to IEC 60770- Reference conditions (All error data refer always refer to the set span) Increasing characteristic Start-of-scale value 0 bar/kpa/psi Stainless steel seal diaphragm Silicone oil filling Room temperature 5 C (77 F) Measuring span ratio r (spread, Turn-Down) r = max. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility Linear characteristic - 0 mbar/ kpa/0.9 psi r 5 : 5<r 0 : 0<r 0 : - 60 mbar/6 kpa/0.87 psi r 5 : 5<r 60 : - 50 mbar/5 kpa/.6 psi 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi 5 bar/500 kpa/7.5 psi 0 bar/ MPa/45 psi Square-rooted characteristic (flow > 50 %) r 5 : 5<r 00 : - 0 mbar/ kpa/0.9 psi r 5 : 5<r 0 : 0<r 0 : - 60 mbar/6 kpa/0.87 psi r 5 : 5<r 60 : - 50 mbar/5 kpa/.6 psi 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi 5 bar/500 kpa/7.5 psi 0 bar/ MPa/45 psi Square-rooted characteristic (flow > 5... 50 %) r 5 : 5<r 00 : - 0 mbar/ kpa/0.9 psi r 5 : 5<r 0 : 0<r 0 : - 60 mbar/6 kpa/0.87 psi r 5 : 5<r 60 : - 50 mbar/5 kpa/.6 psi 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi 5 bar/500 kpa/7.5 psi 0 bar/ MPa/45 psi r 5 : 5<r 00 : 0.075 % (0.009 r + 0.07) % (0.0045 r + 0.07) % 0.075 % (0.005 r + 0.05) % 0.065 % (0.004 r + 0.045) % 0.075 % (0.009 r + 0.07) % (0.0045 r + 0.07) % 0.5 % (0.005 r + 0.05) % 0.065 % (0.004 r + 0.045) % 0.5 % (0.0058 r + 0.4) % (0.009 r + 0.4) % 0.05 % (0.0 r+0.) % 0. % (0.008 r + 0.09) % /56 Siemens FI 0 06 US Edition

Siemens AG 06 SITRANS P, DS III for differential pressure and flow Measuring accuracy (continued) Acc. IEC 60770- Influence of ambient temperature (in percent per 8 C (50 F)) 0 mbar/ kpa/0.9 psi (0.5 r + 0.) % 60 mbar/6 kpa/0.87 psi (0.075 r + 0.) % 50 mbar/5 kpa/.6 psi (0.05 r + 0.5) % 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi 5 bar/500 kpa/7.5 psi 0 bar/ MPa/45 psi Influence of static pressure on the zero point - 0 mbar/ kpa/0.9 psi (0.5 r) % per bar (zero-point correction is possible with position error adjustment) - 60 mbar/6 kpa/0.87 psi 50 mbar/5 kpa/.6 psi 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi - 5 bar/500 kpa/7.5 psi 0 bar/ MPa/45 psi on the span (0. r) % per 70 bar (zero-point correction is possible with position error adjustment) (0. r) % per 70 bar (zero-point correction is possible with position error adjustment) - 0 mbar/ kpa/0.9 psi 0. % per bar - 60 mbar/6 kpa/0.87 psi 0.4 % per 70 bar 50 mbar/5 kpa/.6 psi 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi 5 bar/500 kpa/7.5 psi 0 bar/ MPa/45 psi Long-term stability Static pressure max. 70 bar/7 MPa/ 05 psi (temperature change ± 0 C (± 54 F)) 0 mbar/ kpa/0.9 psi (0. r) % per year 60 mbar/6 kpa/0.87 psi (0.5 r) % in 5 years 0 bar/ MPa/45 psi 50 mbar/5 kpa/.6 psi (0.5 r) % in 5 years 600 mbar/60 kpa/8.7 psi 600 mbar/60 kpa/. psi 5 bar/500 kpa/7.5 psi Effect of mounting position (in pressure per change in angle) 0.7 mbar/0.07 kpa/0.08 inh O per 0 inclination (zero-point correction is possible with position error adjustment) Effect of auxiliary power supply 0.005 % per V (in percent per change in voltage) Measuring value resolution for PROFIBUS PA and 0-5 of nominal measuring range FOUNDATION Fieldbus Siemens FI 0 06 US Edition /57

Siemens AG 06 SITRANS P, DS III for differential pressure and flow Rated conditions Degree of protection (to EN 6059) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium Measuring cell with silicone oil filling -40... +00 C (-40... + F) -0... +00 C (-4... + F) with 0 bar measuring cell Measuring cell with inert filling liquid -0... +00 C (-4... + F) In conjunction with dust explosion protection -0... +60 C (-4... +40 F) Ambient conditions Ambient temperature - Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40... +85 C (-40... +85 F) -0... +85 C (-4... +85 F) with 0 bar measuring cell - Display readable -0... +85 C (-... +85 F) Storage temperature -50... +85 C (-58... +85 F) Climatic class - Condensation Relative humidity 0... 00 % Condensation permissible, suitable for use in the tropics Electromagnetic Compatibility - Emitted interference and interference Acc. to IEC 66 and NAMUR NE immunity Design Weight (without options) Die-cast aluminum: 4.5 kg ( 9.9 lb) Stainless steel precision casting: 7. kg ( 5.6 lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi or stainless steel precision casting, mat. no..4408 Wetted parts materials Seal diaphragm Stainless steel, mat. no..4404/6l or Hastelloy C76, mat. no..489, Monel, mat. no..460, tantalum or gold Process flanges and sealing screw Stainless steel, mat. no..4408, Hastelloy C4, mat. no..460 or Monel, mat. no..460 O-Ring FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 00 bar (450 psi) at 60 C (40 F)) Process connection Female thread ¼-8 NPT and flange connection with mounting thread M0 to DIN 9 or / 6-0 UNF to IEC 658 Material of mounting bracket Steel Sheet-steel, Mat. No..00, chrome-plated Stainless steel Sheet stainless steel, mat. no..40 (SS 04) Power supply U H HART PROFIBUS PA/ FOUNDATION Fieldbus Terminal voltage on transmitter 0.5... 45 V DC - 0.5... 0 V DC in intrinsically-safe mode Power supply - Supplied through bus Separate 4 V power supply necessary - No Bus voltage Not Ex - 9... V With intrinsically-safe operation - 9... 4 V Current consumption Basic current (max.) -.5 ma Start-up current basic current - Yes Max. current in event of fault - 5.5 ma Fault disconnection electronics (FDE) available - Yes /58 Siemens FI 0 06 US Edition

Siemens AG 06 SITRANS P, DS III for differential pressure and flow Certificates and approvals HART PROFIBUS PA/ FOUNDATION Fieldbus Classification according to PED 04/68/EU PN /60 (MAWP 464/0 psi) for gases of fluid group and liquids of fluid group ; complies with requirements of article 4, paragraph (sound engineering practice) PN 40 (MAWP 609) for gases of fluid group and liquids of fluid group ; complies with basic safety requirements of Article 4, paragraph (appendix ); assigned to category III, conformity evaluation module H by the TÜV Nord. Drinking water approval Und. Lab. Clfd in accordance with NSF/ANSI 7 Explosion protection Intrinsic safety "i" PTB ATEX 007 X - Marking Ex II / G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +70 C (-40... +58 F) temperature class T5; -40... +60 C (-40... +40 F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: U i = 0 V, I i = 00 ma, P i = 750 mw; R i =00 FISCO supply unit: U o = 7.5 V, I o = 80 ma, P o = 5. W Linear barrier: U o = 4 V, I o = 50 ma, P o =. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Explosion-proof "d" PTB 99 ATEX 60 - Marking Ex II / G Ex d IIC T4/T6 Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +60 C (-40... +40 F) temperature class T6 - Connection To circuits with values: U H = 0.5... 45 V DC Dust explosion protection for zone 0 PTB 0 ATEX 055 - Marking Ex II D Ex ta IIIC T0 C Da Ex II / D Ex ta/tb IIIC T0 C Da/Db - Permissible ambient temperature -40... +85 C (-40... +85 F) - Max. surface temperature 0 C (48 F) - Connection To certified intrinsically-safe circuits with peak values: U i = 0 V, I i = 00 ma, P i = 750 mw, R i = 00 To circuits with values: U H =9... V DC FISCO supply unit: U o = 7.5 V, I o = 80 ma, P o = 5. W Linear barrier: U o = 4 V, I o = 50 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Dust explosion protection for zone / PTB 0 ATEX 055 - Marking Ex II D Ex tb IIIC T0 C Db - Connection To circuits with values: U H =0.5...45 V DC; P max =. W Type of protection "n" (zone ) PTB ATEX 007 X - Marking Ex II / G Ex na IIC T4/T5/T6 Gc Ex II / G Ex ic IIC T4/T5/T6 Gc - Connection (Ex na) U m = 45 V U m = V - Connection (Ex ic) To circuits with values: U i = 45 V To circuits with values: U H =9... V DC; P max = W FISCO supply unit ic: U o = 7.5 V, I o = 570 ma Linear barrier: U o = V, I o = ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Explosion protection acc. to FM Certificate of Compliance 008490 - Identification (XP/DIP) or (IS); (NI) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; CL I, ZN 0/ AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance 565 - Identification (XP/DIP) or (IS) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Siemens FI 0 06 US Edition /59

Siemens AG 06 HART communication HART 0... 00 Protocol HART Version 5.x Software for PC SIMATIC PDM PROFIBUS PA communication Simultaneous communication with 4 master class (max.) The address can be set using Configuration tool or local operation (standard setting address 6) Cyclic data usage Output byte 5 (one measured value) or 0 (two measured values) Input byte 0,, or (register operating mode and reset function for metering) Internal preprocessing Device profile PROFIBUS PA Profile for Process Control Devices Version.0, class B Function blocks Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0... 00 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container Max. 0 nodes characteristic with - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function FOUNDATION Fieldbus communication Function blocks function blocks analog input, function block PID Analog input - Adaptation to customerspecific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable 0... 00 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FOUNDATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /60 Siemens FI 0 06 US Edition

Siemens AG 06 SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN /60 (MAWP 464/0 psi) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Article No. 7 M F 4 4-7 7 7 7 7-7 7 7 7 Y Silicone oil normal Inert liquid ) grease-free to cleanliness level Measuring span (min.... max.) PN (MAWP 464 psi)... 0 mbar ) (0.405... 8.0 inh O) B PN 60 (MAWP 0 psi)... 60 mbar (0.405... 4.09 inh O) C.5... 50 mbar (.004... 00.4 inh O) D 6... 600 mbar (.409... 40.9 inh O) E 6... 600 mbar (6.44... 64.4 inh O) F 50... 5000 mbar (0.08... 008 inh O) G 0.... 0 bar (4.5... 45 psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum ) Tantalum E Monel ) Monel H Gold ) Gold L Version for diaphragm seal4) 5) 6) 7) Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to IEC 658 - Mounting thread M0 to DIN 9 0 (only for replacement requirement) Vent on side of process flange ) - Mounting thread 7 / 6-0 UNF to IEC 658 6 - Mounting thread M0 to DIN 9 4 (only for replacement requirement) Non-wetted parts materials process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision casting 8) Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, setting for pressure unit: bar Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Article No. SITRANS P DS III with HART pressure transmitters for differential pressure and flow, 7 M F 4 4-7 7 7 7 7 PN /60 (MAWP 464/0 psi) - 7 7 7 7 Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 9) D - "Intrinsic safety and flameproof enclosure" P (Ex ia + Ex d)" 0) - "Ex na/ic (Zone )" ) E - "Intrinsic safety, explosion-proof enclosure R and dust explosion protection (Ex ia+ Ex d + Zone D/D)" 0)) FM + CSA intrinsic safe (is) ) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + S Zone D/D 0))) With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof N C (is + xp)" 9)) Electrical connection/cable entry Screwed gland M0 x.5 B Screwed gland ½-4 NPT C Han 7D plug (plastic housing) incl. mating D connector 4)5) M connectors (stainless steel) 6)7) F Display Without display 0 Without visible display (display concealed, setting: ma) With visible display (setting: ma) 6 with customer-specific display 7 (setting as specified, Order code "Y" or "Y" required) Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: Brief instructions (Leporello) DVD with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) ) For oxygen application, add Order code E0. ) Not suitable for connection of remote seal. Position of the top vent valve in the process flange (see dimensional drawing). ) Not in conjunction with max. span 0 and 60 mbar (8.0 and 4.09 inh O)) 4) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF44.-..Y..-... and 7MF4900-...-.B 7) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 8) Not in conjunction with Electrical connection "Han7D plug". 9) Without cable gland, with blanking plug 0) With enclosed cable gland Ex ia and blanking plug ) Configurations with HAN and M connectors are only available in Ex ic. ) Only in connection with IP66. ) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 4) Only in connection with Ex apporval A, B or E. 5) Permissible only for crimp-contact of conductor cross-section mm 6) Only in connection with Ex approval A, B, E or F. 7) M delivered without cable socket. Siemens FI 0 06 US Edition /6

Siemens AG 06 Y Article No. Pressure transmitters for differential pressure and flow PN /60 (MAWP 464/0 psi) SITRANS P DS III with PROFIBUS PA (PA) 7 M F 4 4 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7 M F 4 4 5 - Click on the Article No. for the online configuration 7 7 7 7 7-7 7 7 7 in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) grease-free to cleanliness level Nominal measuring range PN (MAWP 464 psi) 0 mbar ) (8.0 inh O) B PN 60 (MAWP 0 psi) 60 mbar (4.09 inh O) C 50 mbar (00.4 inh O) D 600 mbar (40.9 inh O) E 600 mbar (64.4 inh O) F 5 bar (008 inh O) G 0 bar (45 psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum ) Tantalum E Monel ) Monel H Gold ) Gold L Version as diaphragm seal 4) 5) 6) 7) Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to IEC 658 - Mounting thread M0 to DIN 9 0 (only for replacement requirement) Venting on side of process flanges ) - Mounting thread 7 / 6-0 UNF to IEC 658 6 - Mounting thread M0 to DIN 9 4 (only for replacement requirement) Non-wetted parts materials process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision casting Version Standard versions International version, English label inscriptions, documentation in 5 languages on DVD (no Order code selectable) Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, setting for pressure unit: bar Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Article No. Pressure transmitters for differential pressure and flow PN /60 (MAWP 464/0 psi) SITRANS P DS III with PROFIBUS PA (PA) 7 M F 4 4 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7 M F 4 4 5-7 7 7 7 7-7 7 7 7 Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 8) D - "Intrinsic safety and flameproof enclosure" P (Ex ia + Ex d)" 9) - "Ex na/ic (Zone )" 0) E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (Ex ia + Ex d + Zone D/D)" 9)) (not for DS III FF) FM + CSA intrinsic safe (is) ) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX)+ S Zone D/D 9))) With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)" 8)) N C Electrical connection/cable entry Screwed gland M0 x.5 B Screwed gland ½-4 NPT C M connectors (stainless steel) ) 4) F Display Without display 0 Without visible display (display concealed, setting: bar) With visible display (setting: bar) 6 With customer-specific display 7 (setting as specified, Order code "Y" required) Included in delivery of the device: Brief instructions (Leporello) DVD with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) ) For oxygen application, add Order code E0. ) Not suitable for connection of remote seal. Position of the top vent valve in the process flange (see dimensional drawing). ) Not in conjunction with max. span 0 and 60 mbar (8.0 and 4.09 inh O)) 4) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF44.-..Y..-... and 7MF4900-...-.B 7) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 8) Without cable gland, with blanking plug. 9) With enclosed cable gland Ex ia and blanking plug. 0) Configurations with HAN and M connectors are only available in Ex ic. ) Only in connection with IP66. ) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. ) Only in connection with Ex approval A, B, E or F. 4) M delivered without cable socket /6 Siemens FI 0 06 US Edition

Siemens AG 06 Further designs Add "-Z" to Article No. and specify Order code. Order code HART PA FF Pressure transmitter with mounting bracket (x fixing angle, x nut, x U-washer or x bracket, x nut, x U-washer) made of: Steel A0 Stainless steel 04 A0 Stainless steel 6L A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A FFPM (Kalrez, compound 4079), for measured medium temperatures -5... 00 C (5... F) A NBR (Buna N) A plug Han 7D (metal) A0 Han 8D (instead of Han 7D) A Angled A Han 8D (metal) A Sealing screws ( units) A40 ¼-8 NPT, with valve in mat. of process flanges Cable sockets for M connectors A50 (metal (CuZn)) Rating plate inscription (instead of German) English B French B Spanish B Italian B4 Cyrillic (russian) B6 English rating plate B Pressure units in inh O and/or psi Quality Inspection Certificate (5-point C characteristic curve test) according to IEC 60770- ) Inspection certificate ) to EN 004-. C Factory certificate to EN 004-. C4 Functional safety (SIL) C0 Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Functional safety (PROFIsafe) C ) Certificate and PROFIsafe protocol Functional safety (SIL/) C Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Drinking water approval C6 Und. Lab. Clfd in accordance with NSF/ANSI 7 Device passport Russia C99 Order code Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Setting of upper limit of D05 output signal to.0 ma Manufacturer's declaration acc. to NACE (MR 00-0 and MR 075-009) D07 (only together with seal diaphragm made of Hastelloy and stainless steel) Degree of protection IP66/IP68 D (only for M0 x.5 and ½-4 NPT) Process flange screws made of Monel D4 (max. nominal pressure PN0) Supplied with oval flange set D7 ( items), PTFE packings and screws in thread of process flanges Capri cable gland 4F CrNi and clamping D59 device (848699 + 8064) included Use in or on zone D/D E0 (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-...-.B.. Ex ia) and IP66) Overfilling safety device for flammable E08 and non-flammable liquids (max. PN (MAWP 464 psi), basic device with type of protection "Intrinsic safety (Ex ia)", to WHG and VbF, not together with measuring cell filling "inert liquid") Oxygen application E0 (In the case of oxygen measurement and inert liquid max. 00 bar (450 psi) at 60 C (40 F)) Export approval Korea E CRN approval Canada E (Canadian Registration Number) Dual seal E4 Explosion-proof "Intrinsic safety" (Ex ia) E5 4) to INMETRO (Brazil) (only for transmitter 7MF4...-...-.B..) "Flameproof" explosion protection E6 4) according to INMETRO (Brazil) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Intrinsic safety" (Ex ia E8 4) + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-...-.P..) Ex Approval IEC Ex (Ex ia) E45 4) (only for transmitter 7MF4...-...-.B..) Ex Approval IEC Ex (Ex d) E46 4) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Intrinsic safety" to E55 4) NEPSI (China) (only for transmitter 7MF4...-...-.B..) Explosion protection "Explosion-proof" E56 4) to NEPSI (China) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Zone " to NEPSI E57 4) (China) (only for transmitter 7MF4...-...-.E..) Ex protection Ex ia, Ex d and Zone E58 4) to NEPSI (China) (only for transmitter 7MF4...-...-.R..) "Intrinsic safety" and "Explosion-proof" E70 4) explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-...-.[B, D]..-Z + E) Siemens FI 0 06 US Edition /6

Siemens AG 06 Order code Order code Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. HART PA FF Further designs HART PA FF Add "-Z" to Article No. and specify Order code. Ex-protection Ex ia according to EAC Ex E80 5) (Russia) Ex-protection Ex d according to EAC Ex E8 5) (Russia) Ex-protection Ex na/ic (Zone ) according E8 5) to EAC Ex (Russia) Ex-protection Ex ia + Ex d + Zone D/D E8 5) according to EAC Ex (Russia) Two coats of lacquer on casing and G0 cover (PU on epoxy) Interchanging of process connection H0 side Vent on side for gas measurements H0 Stainless steel process flanges for vertical H0 differential pressure lines (not together with K0, K0 and K04 6) Transient protector 6 kv (lightning protection) J0 Chambered graphite gasket for process J0 flange Chambered PTFE graphite gasket J0 EPDM O-rings for process flange with J05 approval (WRC/WRAS) Vent valve or blanking plug of process J08 flange welded-in (orientation: on right when viewing the display) 7) Vent valve or blanking plug of process J09 flange welded-in (orientation: on left when viewing the display) 7) Process flange Hastelloy K0 Monel K0 Stainless steel with PVDF insert max. PN 0 (MAWP 45 psi), max. temperature of medium 90 C (94 F) For ½-4 NPT inner process connection on the side in the middle of the process flange, vent valve not possible K04 Factory mounting of valve manifolds, see accessories. Supplementary electronics for 4-wire connection, see accessories. = available ) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. ) If the acceptance test certificate..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. ) Profisafe transmitters can only be operated with the S7 F Systems V6. configuration software in combination with S7-400H 4) Option does not include ATEX approval, but instead includes only the countryspecific approval. 5) Approval pending. 6) Not suitable for connection of remote seal. 7) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. Measuring range to be set Specify in plain text: in the case of linear characteristic curve (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Y0 ) in the case of square rooted characteristic Y0 (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Stainless steel tag plate and entry in Y5 device variable (measuring point description) Max. 6 characters, specify in plain text: Y5:... Measuring point text (entry in device Y6 variable) Max. 7 char., specify in plain text: Y6:... Entry of HART address (TAG) Y7 Max. 8 char., specify in plain text: Y7:... Setting of pressure indicator in Y pressure units Specify in plain text (standard setting: bar): Y: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indicator in nonpressure units ) Specify in plain text: Y:... up to... l/min, m /h, m, USgpm,... (specification of measuring range in pressure units "Y0" or "Y0" is essential, unit with max. 5 characters) Y ) + Y0 or Y0 Preset bus address Y5 possible between and 6 Specify in plain text: Y5:... Damping adjustment in seconds (0... 00 s) Y0 Factory mounting of valve manifolds, see accessories. Only Y0, Y5, Y6, Y7, Y, Y, Y5 and D05 can be factory preset = available ) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. ) Preset values can only be changed over SIMATIC PDM. ) Not in conjunction with over-filling safety device for flammable and nonflammable liquids (Order code "E08") /64 Siemens FI 0 06 US Edition

Siemens AG 06 SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 40 (MAWP 609 psi) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Article No. 7 M F 4 5-7 7 7 7 7-7 7 7 7 Y Silicone oil normal Inert liquid ) grease-free to cleanliness level Measuring span (min.... max.).5... 50 mbar (.004... 00.4 inh O) D 6... 600 mbar (.409... 40.9 inh O) E 6... 600 mbar (6.44... 64.4 inh O) F 50... 5000 mbar (0.08... 008 inh O) G 0.... 0 bar (4.5... 45 psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Gold ) Gold L Version for diaphragm seal ) 4) 5) 6) Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to IEC 658 - Mounting thread M to DIN 9 (only for replacement requirement) Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing) - Mounting thread 7 / 6-0 UNF to IEC 658 7 - Mounting thread M to DIN 9 5 (only for replacement requirement) Non-wetted parts materials process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision casting 7) Version Standard version, German plate inscription, setting for pressure unit: bar) International version, English plate inscription, setting for pressure unit: bar Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 8) D - "Intrinsic safety and flameproof enclosure" P (Ex ia + Ex d)" 9) - "Ex na/ic (Zone )" 0) E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (Ex ia+ Ex d + Zone D/D)" 9)) FM + CSA intrinsic safe (is) ) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + S Zone D/D 9))) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)" 8)), max PN 60 N C Article No. SITRANS P DS III with HART pressure transmitters for differential pressure and flow, 7 M F 4 5-7 7 7 7 7 PN 40 (MAWP 609 psi) - 7 7 7 7 Electrical connection/cable entry Screwed gland M0x.5 B Screwed gland ½-4 NPT C Han 7D plug (plastic housing) incl. mating connector )4) D M connectors (stainless steel) 5) 6) F Display Without display 0 Without visible display (display concealed, setting: ma) With visible display (setting: ma) 6 with customer-specific display 7 (setting as specified, Order code "Y" or "Y" required) Power supply units see Chap. 7 "Supplementary Components". Scope of delivery: Pressure transmitter as ordered (Instruction Manual is extra ordering item) ) For oxygen application, add Order code E0. ) Not in conjunction with max. span 600 mbar (40.9 inh O) ) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) If the acceptance test certificate..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF45.-..Y..-... and 7MF4900-...-.B 6) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 7) Not in conjunction with Electrical connection "Han7D plug". 8) Without cable gland, with blanking plug 9) With enclosed cable gland Ex ia and blanking plug 0) Configurations with HAN and M connectors are only available in Ex ic. ) Only in connection with IP66. ) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. ) Only in connection with Ex approval A, B or E. 4) Permissible only for crimp-contact of conductor cross-section mm 5) Only in connection with Ex approval A, B, E or F. 6) M delivered without cable socket. Siemens FI 0 06 US Edition /65

Siemens AG 06 Y Article No. Pressure transmitters for differential pressure and flow, PN 40 (MAWP 609 psi) SITRANS P DS III with PROFIBUS PA (PA) 7 M F 4 5 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7 M F 4 5 5 - Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) grease-free to cleanliness level Nominal measuring range 50 mbar (00.4 inh O) D 600 mbar (40.9 inh O) E 600 mbar (64.4 inh O) F 5 bar (008 inh O) G 0 bar (45 psi) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Gold ) Gold L ) 4) 5) 6) Version for diaphragm seal Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to IEC 658 - Mounting thread M to DIN 9 (only for replacement requirement) Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing). - Mounting thread 7 / 6-0 UNF to IEC 658 7 - Mounting thread M to DIN 9 5 (only for replacement requirement) Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision casting Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, setting for pressure unit: bar Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. 7 7 7 7 7-7 7 7 7 Article No. Pressure transmitters for differential pressure and flow, PN 40 (MAWP 609 psi) SITRANS P DS III with PROFIBUS PA (PA) 7 M F 4 5 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7 M F 4 5 5-7 7 7 7 7-7 7 7 7 Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 7) D - "Intrinsic safety and flameproof enclosure" P (Ex ia + Ex d)" 8) - "Ex na/ic (Zone )" 9) E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (Ex ia + Ex d + Zone D/D)" 8) 0) (not for DS III FF) FM + CSA intrinsic safe (is) ) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX)+ S Zone D/D 9)0)) With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof N C (is + xp)" 7)), max PN 60 Electrical connection/cable entry Screwed gland M0 x.5 B Screwed gland ½-4 NPT C M connectors (stainless steel) ) ) F Display Without (display hidden) 0 Without visible display (display concealed, setting: bar) With visible display (setting: bar) 6 With customer-specific display (setting as 7 specified, Order code "Y" required) Included in delivery of the device: Brief instructions (Leporello) DVD with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) ) For oxygen application, add Order code E0. ) Not in conjunction with max. span 600 mbar (40.9 inh O) ) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) If the acceptance test certificate..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF45.-..Y..-... and 7MF4900-...-.B 6) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 7) Without cable gland, with blanking plug. 8) With enclosed cable gland Ex ia and blanking plug. 9) Configurations with HAN and M connectors are only available in Ex ic. 0) Only in connection with IP66. ) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. ) Only in connection with Ex approval A, B, E or F. ) M delivered without cable socket /66 Siemens FI 0 06 US Edition

Siemens AG 06 Further designs Add "-Z" to Article No. and specify Order code. Order code HART PA Pressure transmitter with mounting bracket (x fixing angle, x nut, x U-washer or x bracket, x nut, x U-washer) made of: Steel A0 Stainless steel 04 A0 Stainless steel 6L A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A FFPM (Kalrez, compound 4079), for measured medium temperatures -5... 00 C (5... F) A NBR (Buna N) A Plug Han 7D (metal) A0 Han 8D (instead of Han 7D) A Angled A Han 8D (metal) A Sealing screws ( units) A40 ¼-8 NPT, with valve in mat. of process flanges Cable sockets for M connection A50 (metal (CuZn)) Rating plate inscription (instead of German) English B French B Spanish B Italian B4 Cyrillic (russian) B6 English rating plate B Pressure units in inh O and/or psi Quality Inspection Certificate (5-point characteristic C curve test) according to IEC 60770- Inspection certificate C Acc. to EN 004-. Factory certificate C4 Acc. to EN 004-. Functional safety (SIL) C0 Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Functional safety (PROFIsafe) C ) Certificate and PROFIsafe protocol Functional safety (SIL/) C Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Device passport Russia C99 Setting of upper limit of output signal to D05.0 ma Manufacturer's declaration acc. to NACE D07 (MR 00-0 and MR 075-009) (only together with seal diaphragm made of Hastelloy and stainless steel) Degree of protection IP66/IP68 D (only for M0 x.5 and ½-4 NPT) Nom. press. rating PN 500 (MAWP 750 psi) D56 (Only for measuring cell 600 mbar... 0 bar (40 inh O... 45 psi), SIL- and Ex-options not possible)) ) Capri cable gland 4F CrNi and clamping D59 device (848699 + 8064) included Use in or on zone D/D E0 (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-...-.B.. Ex ia) and IP66) FF Order code Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Export approval Korea E CRN approval Canada E 4) (Canadian Registration Number) Dual seal E4 Explosion-proof "Intrinsic safety" (Ex ia) to E5 ) INMETRO (Brazil) (only for transmitter 7MF4...-...-.B..) "Flameproof" explosion protection according E6 ) to INMETRO (Brazil) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Intrinsic safety" (Ex ia + Ex E8 ) d) to INMETRO (Brazil) (only for transmitter 7MF4...-...-.P..) Ex Approval IEC Ex (Ex ia) E45 ) (only for transmitter 7MF4...-...-.B..) Ex Approval IEC Ex (Ex d) E46 ) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Intrinsic safety" E55 ) to NEPSI (China) (only for transmitter 7MF4...-...-.B..) Ex prot. "Explosion-proof" to NEPSI (China) E56 ) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Zone " to NEPSI (China) E57 ) (only for transmitter 7MF4...-...-.E..) Ex protection Ex ia, Ex d and Zone to E58 ) NEPSI (China) (only for transmitter 7MF4...-...-.R..) "Intrinsic safety" and "Explosion-proof" E70 ) explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-...-.[B, D]..-Z + E) Ex-protection Ex ia acc. to EAC Ex (Russia) E80 4) Ex-protection Ex d acc. to EAC Ex (Russia) E8 4) Ex-protection Ex na/ic (Zone ) according to E8 4) EAC Ex (Russia) Ex-protection Ex ia + Ex d + Zone D/D E8 4) according to EAC Ex (Russia) Two coats of lacquer on casing and cover G0 (PU on epoxy) Interchanging of process connection side H0 Stainless steel process flanges for vertical H0 differential pressure lines Transient protector 6 kv (lightning protection) J0 Chambered graphite gasket for process flange J0 EPDM O-rings for process flange with approval J05 (WRC/WRAS) Vent valve or blanking plug of process J08 flange welded-in (orientation: on right when viewing the display) 5) Vent valve or blanking plug of process flange welded-in (orientation: on left when viewing the display) 5) J09 ) Profisafe transmitters can only be operated with the S7 F Systems V6. configuration software in combination with S7-400H ) Tested according to IEC 600. Only for measuring materials of the group of fluids in accordance with PED permissible. Not for use with dangerous media suitable. ) Option does not include ATEX approval, but instead includes only the country-specific approval. 4) Approval pending. 5) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. Siemens FI 0 06 US Edition /67

Siemens AG 06 Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text: in the case of linear characteristic curve (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Y0 ) in the case of square rooted characteristic Y0 (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Stainless steel tag plate and entry in Y5 device variable (measuring point description) Max. 6 characters, specify in plain text: Y5:... Measuring point text (entry in device variable) Y6 Max. 7 char., specify in plain text: Y6:... Entry of HART address (TAG) Y7 Max. 8 char., specify in plain text: Y7:... Setting of pressure indication in pressure Y units Specify in plain text (standard setting: bar): Y: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H O *), inh O *), fth O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C Setting of pressure indication in non-pressure units ) Specify in plain text: Y:... up to... l/min, m /h, m, USgpm,... (specification of measuring range in pressure units "Y0" or "Y0" is essential, unit with max. 5 characters) Y + Y0 or Y0 Preset bus address Y5 possible between and 6 Specify in plain text: Y5:... Damping adjustment in seconds (0... 00 s) Y0 Factory mounting of valve manifolds, see accessories. Only Y0, Y5, Y6, Y7, Y, Y, Y5 and D05 can be factory preset. = available ) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. ) Preset values can only be changed over SIMATIC PDM. /68 Siemens FI 0 06 US Edition

Siemens AG 06 Dimensional drawings 5 (0.6) 4 (5.6) 69 (.7) 5 (.) 9 (.4) 4 (0.94) 84 (.) 5 Ø80 (.5) 50 (.97) 8 (5.04) 6 7 8 66 (6.54) 4 (5.8) min. 90 (.54) 4) Space for rotation of housing approx. 96 (.78) 7 (0.67) 5 (.05) 9 0 96 (.8) 6 (0.) 4 7 (.8) 05 (4.) 68 (.7) 0 (4.7) 4 5 Electronic side, digital display (longer overall length for cover with window) ) Terminal side ) Electrical connection: Screwed gland M0 x,5 or Screwed gland ½-4 NPT or Han 7D/ Han 8D ) ) plug Harting adapter Protective cover over keys 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Lateral venting for liquid measurement (Standard) 9 Lateral venting for gas measurement (suffix H0) 0 Mounting bracket (option) Sealing screw with valve (option) Process connection: ¼-8 NPT (IEC 658) ) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "Explosion-proof enclosure" ) Not with type of protection "FM + CSA" [IS + XP]" 4) 9 mm (.6 inch) for minimum distance to permit rotation with indicator SITRANS P DS III pressure transmitters for differential pressure and flow, dimensions in mm (inch) Siemens FI 0 06 US Edition /69

Siemens AG 06 5 4 (5.6) (0.6) 5 (.) 4 (0.94) approx. 96 (.78) 7 (0.67) 9 (.4) 84 (.) 5 Ø80 (.5) 50 (.97) min. 90 (.54) 4) Space for rotation of housing 4 8 approx. 85 (.5) 6) 6 7 8 9 8 (5.04) approx. 7 (8.54) 7) 60 (.6) 5) 65 (.56) approx. 87 (.4) 4 Electronic side, digital display (longer overall length for cover with window) ) Terminal side ) Electrical connection: Screwed gland M0 x,5 or Screwed gland ½-4 NPT or Han 7D/ Han 8D ) ) plug Harting adapter 5 Protective cover over keys 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Sealing screw with valve (option) 9 Process connection: ¼-8 NPT (IEC 658) ) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "Explosion-proof enclosure" ) Not with type of protection "FM + CSA" [IS + XP]" 4) 9 mm (.6 inch) for minimum distance to permit rotation with indicator 5) 74 mm (.9 inch) for PN 40 (MAWP 609 psi) 6) 9 mm (.6 inch) for PN 40 (MAWP 609 psi) 7) 9 mm (8.6 inch) for PN 40 (MAWP 609 psi) SITRANS P DS III pressure transmitters for differential pressure and flow, with process covers for vertical differential pressure lines, optional "H0", dimensional drawing, dimensions in mm (inch) SITRANS P DS III pressure transmitters for differential pressure and flow, with process covers for vertical differential pressure lines /70 Siemens FI 0 06 US Edition