Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Similar documents
PERSONAL AIR BREATHING UNIT

STERILIZABLE DISSOLVED OXYGEN SENSORS

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

SPECIFICATIONS APCEPH1

Dissolved Oxygen Sensor

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

RAM 4021 Operation Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Oxygen Measurement Systems High Reliability and Wide Application Coverage

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Operation Manual. O2 Quickstick. Oxygen Analyzer

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Installation, Operation, and Maintenance Manual

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

NEULOG OXYGEN LOGGER SENSOR GUIDE

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

with O 2 Controller Instruction Manual

Columbus Instruments

Technical Data Sheet MF010-O-LC

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

AIR/OVER HYDRAULIC JACK 20 TON

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

BI-680 Online Dissolved Oxygen Controller Instruction Manual

NIV EAU MATIC ST User Manual Made in Canada

OxyProbe II Instruction Manual

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

200 PSI FAST-FILL AIR SOURCE KIT

QUICK START GUIDE TO DRINKING WATER MONITORING

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Stainless Steel 142 mm Filter Holder YY

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

RAM Operation Manual

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

VERTICAL AIR COMPRESSORS

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

VERTICAL AIR COMPRESSORS

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Operating Instructions Part No

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

200 PSI HIGH-FLOW AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

This test shall be carried out on all vehicles equipped with open type traction batteries.

1 DRIVE INDUSTRIAL IMPACT WRENCH

CSA Sample Draw Aspirator Adapter Operator s Manual

HBLT-A1 LIQUID LEVEL SENSOR

DTG - LCD Digital Temperature Gauge USER MANUAL

Transmitter CS 21 Operation Manual

Manual of SF6 Comprehensive Tester

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

MODEL GT820 OXYGEN SENSOR

RAM 4021-DPX Operation Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Transmitter CS 21 Operation Manual

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Hydraulic Punch Drivers

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Operator Quick Guide ORBISPHERE 3654

Manual Actuated Boiler Blowdown Valves

SILENTAIRE TECHNOLOGY

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

PANACEA P125 USER MANUAL

BD Cytopeia Fluidic Kit User s Guide

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Transferpette -8/-12

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor

Free Chlorine Sensor For additional information, please visit our website at

Oxygen Sensor with Electrode

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

DISSOLVED OXYGEN SENSOR BT34i

TECHNICAL DATA CAUTION

User Instruction Manual

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

444C DUAL PERFORMANCE VALUE PACK

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

Operating Instructions Part No

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

PURITY INSTALLATION INSTRUCTIONS MODEL P40

Transcription:

Dextens Thermo Conductivity Sensors Type 52101, 54101, 55101 Operating Manual May 2012

Table of Content 1 GENERAL INFORMATION...4 1.1 DISCLAIMER...4 1.2 SYMBOLS AND CONVENTIONS...4 1.3 SERVICES AND REPAIRS...4 1.4 CE CONFORMITY...4 2 INTRODUCTION...5 2.1 CONTENT OF PACKAGE: THERMO CONDUCTIVITY (TC) SENSOR...5 2.2 ACCESSORIES...5 2.3 STORAGE INFORMATION...6 2.4 TECHNICAL SPECIFICATIONS...6 2.5 SENSOR DIMENSIONS...7 2.6 PRINCIPLE OF MEASUREMENT...7 3 MAINTENANCE AND CALIBRATION...8 3.1 INTRODUCTION...8 3.2 WHAT TO MAINTAIN...8 3.3 DISASSEMBLY...8 3.4 REPLACING THE MEMBRANE...10 3.5 REASSEMBLY...14 3.6 CALIBRATION...16 4 TROUBLE SHOOTING...17 4.1 CALIBRATION OUTSIDE OF THE DEFINED RANGE...17 4.2 PUNCTURED MEMBRANE...17 4.3 EMPTY ELECTROLYTE RESERVOIR...17 4.4 DIRTY SENSOR...17 4.5 SLOW SENSOR...17 3

1 General Information 1.1 Disclaimer Please read and understand the user manual before installing and using the products described herein. It is also recommended to follow the safety recommendations from this manual. The material in this manual is for informational purposes only. The products it describes are subject to change without prior notice, due to the manufacturer s continuous development program. Dextens makes no representations or warranties with respect to this manual and shall not be liable for any damages, losses, costs or expenses, direct, indirect or incidental, consequential or special, arising out of, or related to the use of this manual. All rights reserved. No part of this manual may be used or reproduced in any form or by any means without prior written permission of Dextens. 1.2 Symbols and Conventions The danger sign (below) indicates actions or configurations that may be dangerous for the user or that may lead to wrong measurements. Read and understand these paragraphs before starting to use the described material. 1.3 Services and Repairs No sensor components can be repaired by the user. Only personnel from Dextens or its approved representative(s) is (are) authorized to attempt repairs to the sensor and only components formally approved by the manufacturer should be used. Any attempt at repairing the sensor in contravention of these principles could cause damage to the sensor and corporal injury to the person carrying out the repair. It renders the warranty null and void and could compromise the correct working of the sensor and the electrical integrity or the CE compliance of the sensor. 1.4 CE Conformity The TC sensors instruments are manufactured conforming to the requirements of the electromagnetic compatibility directive 89/336/CEE and the low voltage directive 73/23/CEE. 4

2 Introduction 2.1 Content of Package: Thermo Conductivity (TC) Sensor When ordering a TC sensor, you will receive the following item: 52201: H2 sensor / 52401 CO2 sensor / 52501 N2 sensor Physical Description: 1.Purge Gas Outlet 2.Protection Cap 1 2 3 3.Purge Gas Inlet 4.Output Connection to instrument 5.Input Connection from in-line temperature sens 4 5 This user manual 2.2 Accessories Depending on your order, additional accessories can be delivered: Part Nr. 75502.mmm Cable for connecting the sensor to a process instrument 5

Part Nr. 87410 / 87411 Sensor maintenance kit 2.3 Storage Information During a long period of inactivity (more than 1 week) the sensor should be removed, wiped dry and stored properly. For shorter periods of inactivity (weekends) it is not necessary to remove the sensor: it may stay in place with the instrument turned on, and with purge gas supplied. Storage instructions: - rinse possible deposits on sensor s head (rinse under tap water) - wipe sensor head dry - put a small silica desiccant bag inside the storage cap - put the storage cap in place - store the sensor in a safe dry place - temperature of storage place must be stable and correspond to common indoor levels Rapid temperature changes must be avoided (for instance air conditioning turned on and off daily) : they can create condensation inside the sensor s cell and damage the electronics inside. 2.4 Technical Specifications Sensor Model CO2 H2 N2 Sensor serial number 52401 52201 52201 52501 Membrane model number 90956 90956 90952 90956 Measurement range at 25 C 0-15 g/kg 0-2 ppm 0-10 ppm 0-350 ppm Linear flow rate 50 cm/sec N/A N/A 150 cm/sec Accuracy 1% of the measured value or lowest value whichever is greater Temperature compensation 0 C to + 50 C / 32 F to 113 F Temperature range CIP or SIP resistant up to 120 C / 248 F Pressure range 0 20 bars Cycle time 20 sec Recommended purge gas N2 or air N2 or air N2 or air CO2 or air Weight 0.6 kg Enclosure protection IP65 Material in contact with sample ANSI 316L, PFA or Tefzel Sensor cable 3m standard length / optional extension up to 1000 m 6

Introduction 2.5 Sensor Dimensions Length: 159 mm Max Diameter: 59 mm Min Diameter: 27.95 mm D 59 mm 159 mm M42x1.5 D 27.95 mm 2.6 Principle of Measurement This thermal conductivity sensor is designed to continuously measure Carbon dioxide (CO2), Nitrogen (N2) or Hydrogen (H2). Measurements are possible in dissolved or gaseous applications. The sensor operates on the following principle: the gas to measure diffuses from the sample into a micro volume contained in the sensor through a semi-permeable membrane, and comes into contact with a gas thermal conductivity detector. The temperature and the change in thermal conductivity induced by the presence of the gas is measured. The duration of a single measurement is too short to get a reliable measure: successive measurements are made, which induce each time a conductivity curve. The average slope of each measurement curve determines the average conductivity, which gives the gas concentration of the sample. To perform the successive measurements, it is necessary to purge the gas enclosed in the micro-volume (every 10 seconds). This purge is done by injecting a purge gas, which is different from the sample to be measured (for instance N2 for a CO2 measurement). A purge valve controlled by an electronic card drives this process. After each purge, the gas to be measured diffuses again through the membrane into the sensor and a new measurement is performed. 7

3 Maintenance and Calibration 3.1 Introduction This guide explains how to clean and carry out basic maintenance of Dextens thermo-conductivity (TC) sensor models: There is no definitive rule to when you clean a sensor. Nor is there is a standard service interval. However, you should clean a sensor when: It is slow It is noisy The calibration is out of range It is visibly dirty Dextens offers a maintenance kit and cleaning unit which provides all the components necessary to complete the cleaning and basic maintenance of a sensor. Periodically, check the sensor calibration using a known standard. As long as the reading is ±1 % of the expected value no action needs to be taken. If the calibration has changed ±1 10 %, perform a new calibration. If the deviation is more than 10% of the original values, a membrane service will be required. Only change the sensor membrane when troubleshooting indicates that the membrane has failed. A visual inspection of the sensor face will also reveal any problem like dust deposits or accumulation of dirt onto the protection grill. Please carry out the following operations in a clean dry place in order to avoid the possibility of blocking or damaging the stainless steel grill in the sensor s face, or of allowing water to get into the sensor. Very Important Note: Unlike your O2 sensor, please remember that the TC sensors do not require regular servicing. While the membrane replacement procedure on these sensors is similar to that of the electrochemical sensor, no chemical or electrochemical cleaning is required, and furthermore, membrane changes need be performed far less often, if at all. 3.2 What to maintain There are just two components which should require maintenance on a TC sensor: The Dacron gauze filter The membrane We recommend that whenever the membrane is changed, the Dacron gauze filter is also changed. 3.3 Disassembly Remove the sensor from its flow chamber: Before removing the sensor from a sensor socket, make sure to first drain all liquid from the pipe. (If you are using a model 74001.00, 28mmTuchenhagen insertion/extraction valve, the sample is sealed off automatically as the sensor is withdrawn.) Holding the sensor handle in one hand, carefully unscrew the collar and pull the sensor out of the mounting (sensor socket, flow chamber, or other mounting, see section 2.2). You can stop the opening by replacing the sensor with the stainless steel plug and collar supplied for this purpose. 8

Maintenance and Calibration After removing the sensor from the line, unscrew the protection cap. Lift off the cap, taking care not to lose the grill and washers inside. Note: never remove the protection cap unless the membrane has failed. Dry the sensor thoroughly with a paper towel. The protective cap has a number of components which should come out with the cap when it is removed. To remove the Dacron gauze, simply gently push the contents of the protective cap apart. 9

Maintenance and Calibration Note the different components and washers. With the exception of the Dacron gauze, these can usually be re-used. 1. Protective cap 2. Tefzel washers 3. Grill (0.2 mm) 4. Dacron Gauze 5. Silicone washers 1 2 3 4 5 3.4 Replacing the Membrane Remove the membrane tightening ring with the tool. Place the larger section of the tool over the ring and pull to tool until it is tight around the rings middle section. Now just lift the removal tool and the membrane and tightening ring will come free. Take care that the protective pastille remains in place (it can fall out). If it does fall out, simply replace it with great care DO NOT TOUCH the chip. It is extremely delicate and easily damaged. Remove the old membrane to reveal the stainless steel grill in the sensing face. The grill must be clean and dry. If necessary, wipe it with a paper tissue. Be careful not to drop the membrane support disk. If the mesh covering this support disk is damaged, replace the support disk with a new one. If the support disk is removed, the delicate sensing element is exposed. Do not touch it, even with a tissue bonding wires would be irreversibly damaged. 10

Maintenance and Calibration You are now ready to replace the membrane: Stand the sensor on a flat bench surface so that it rests on its back end, with its working end facing up. Take the membrane installation tool from the maintenance kit and separate it into its two parts. Attach the tightening ring to the inner part as shown in the image on the right. 11

Maintenance and Calibration Place the lower part of the tool onto the sensor head as shown. Select a membrane from the maintenance kit. Take care do NOT touch the middle surface of the membrane. Using a set of tweesers, place the membrane in the installation tool as shown. 12

Maintenance and Calibration The membrane should be evenly spaced, centrally within the support. Attaching the membrane: Place the upper section, with the tightening ring, over the lower part of the tool and press down slowly with an even but firm pressure. You will feel and hear the tightening ring click into place. 13

Maintenance and Calibration The attached membrane will look as follows: 3.5 Reassembly Replacing washers, dacron and grill. It is important to place the various protective cap components in the correct order. 1.Place 2 tefzel washers in the cap 2. Place the grill 14

Maintenance and Calibration 3. Place the dacron gauze pastille 4. Place the silicone washer Replacing the protective cap: Finally, replace the protective cap by screwing it back onto the sensor head. Take care that the components within the cap remain in place. 15

Maintenance and Calibration 3.6 Calibration The Dextens sensors are sold pre-calibrated and there should be no need to calibrate them between service intervals. For calibration process please refer to the operating manual of Dextens TC instruments. 16

4 Trouble shooting Even if Dexens sensors have been designed to reduce the sources of trouble, some harsh working condition may lead to sensor malfunction. This chapter is here to give some tips to find and correct the problem. 4.1 Calibration outside of the defined range Calibration below 80% - it is possible that the reservoir is overfilled. Open and close the reservoir to reduce pressure and re-measure efficiency. Calibration above 120% - membrane is probably too tight. Place in warm water overnight and re-measure efficiency. 4.2 Punctured Membrane A common problem with our sensor is that the membrane is fragile and can be easily punctured or torn (when not protected by the protective grill). The symptoms of this problem are reading that are not going down or very slowly. The only response to this is to thoroughly clean the sensor and replace the membrane. When the membrane has been broken the sampling liquid enters the reservoir. To get a fully working sensor you will remove all traces of the liquid. 4.3 Empty Electrolyte Reservoir Another frequent problem is that the electrolyte leaks out of the reservoir. This happens after bad maintenance when the operator has not completely closed the reservoir. But the effect of this problem can sometimes be detected after a quite long time because of a small leak. The symptoms of this problem are a sensor that is not measuring anything and which becomes very sensitive to pressure changes. To correct the problem, do a complete maintenance taking much care to completely close the electrolyte reservoir. 4.4 Dirty Sensor After some time, in normal use, the sensors becomes dirty. They are much slower to go down and the response signal is quite noisy. The only thing to do is a maintenance, some times with a chemical clean (see 4.4.4). 4.5 Slow Sensor If, when completing the sodium sulfite test, the sensor does not reach 10 ppb in 10 minutes AND 0.4 ppb in 60 minutes then let the sensor sit for 1 hour connected to the instrument. This will allow the sensor to consume any oxygen which may reside in the electrolyte. Inspect the sensor for air bubbles. If there are none, then, retest the sensor speed. If there are bubbles you must rework the reservoir to remove them either by topping-up the reservoir or completely refilling it. (Note if you completely refill the reservoir you should recalibrate the sensor). If the sensor is still not delivering to specification (bullet point 1 above) allow it to sit overnight connected to the instrument and retest. If after testing and allowing the sensor to sit either for an hour or overnight performance is still not to specification check the following: Is the membrane clean? Are there no bubbles in the reservoir? Inspect the cathode, guard and anode are they clean? Even if they appear clean, re-clean the sensor (we recommend both aggressive and basic cleaning) and recalibrate and retest. If after cleaning, re-cleaning and retesting the sensor is still not performing well, we recommend you contact Dextens 17