Two-stage valve type NE

Similar documents
Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-controlled shut-off valve type CNE

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Pressure-reducing valve type CDK

Diaphragm accumulator type AC

Pressure reducing valves type CDK

Diaphragm accumulator type AC

Over-center valves type LHT with oscillation damping, zero leakage

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure reducing valve, direct operated

Pressure reducing valve, pilot operated

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure reducing valve, direct operated

Universal Charging and Testing Unit FPU-1

Check valve hydraulically pilot operated

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Pressure relief valve, direct operated

180 Series Rotary Shear Directional Control Valve

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Safety and Shut-off Block SAF/DSV

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Technical Data Sheet TI-F50 Locking Units series KFH

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure reducing valve, pilot operated, Model 3DR

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pressure relief valve, direct operated Type DBD

FPD20 Series. Gear wheel flow sensor

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

DK ton, Double-acting, Die-type Crimping Tool

MANUAL. Sesame. Thermoplastic Tank Technologies

Pressure Limiting Valve SPVF Operating Instructions

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

1200B2 Series Service Regulators. Instruction Manual

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Type BBS-03, BBS-05, BBS-06, BBS-25

Electrically Operated Pressure-Relief Cartridge, Size 10

Leak free Pipe Rupture Valve for Excavators

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Installation and commissioning instructions 255 series and 256 series

HPB25 Hydraulic Paving Breaker

Operating and maintenance manual Filter and reducing station Series / 1.0

Pressure relief valves

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

3-Way Pressure-Reducing Cartridge, Size 2 4

1800C and 1800C-HC Series Service Regulators

Series IRV1000/2000/3000

Operation Manual Air Saver Unit ASV5000 Series

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Operating Instructions Hand Test Pump BHP 700

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Pressure maintenance valve SDV-P / SDV-P-E

PVQ 13 A2 R SE 1 S 20 C-11 D

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

INSTRUCTION MANUAL Pressure Relief Device LPT

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Two-port valves, male threaded, PN25

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Controllers DR, DP, FR and DFR

PENCOFLEX COUPLING ASSEMBLY AND MAINTENANCE

Inverse Proportional Pressure-Relief Cart., Size 2 4

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Inverse Proportional Pressure-Relief Cartridge, Size 10

Pressure-Relief Cartridge Valve, Size 4

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Operating manual for the pressure transducer unit CCS 1000

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Safety and operating instructions

Direct Operated Precision Regulator Modular Style. Standard Specifications

PV4 and PV6 Piston Valves

// ADapters GUIDelines

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Operating manual for Material pressure tanks Vol./1 and Vol./2

Yoke Block Instruction Manual

Seated valves VRB 3, VRG 3

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Fixed Displacement Motor A4FM

Related Products: Auto Drain Valve. Model/Specifications. Model

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Inverse Prop. Pressure-Relief Cart., Size 2 4

3-Way Safety Block DSV

OPERATING INSTRUCTIONS

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Operating instruction

EXH. Specifications. Descriptions. Min. working pressure MPa

Pressure Dump Valve Service Kit for Series 2300 Units

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Transcription:

Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0

by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted. Any breach or infringement will result in liability for damages. All rights reserved concerning patent or utility model application. 2/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

Contents 1 Overview of two-stage valve type NE...4 2 Available versions, main data... 5 3 Parameters... 6 3.1 General... 6 4 Dimensions... 8 5 Assembly, operation and maintenance recommendations...10 5.1 Intended application... 10 5.2 Assembly information... 10 5.2.1 Attachment...11 5.2.2 Subsequent pressure adjustment...13 5.3 Operating instructions...14 5.4 Maintenance information...14 6 Other information...15 HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 3/16

1 Overview of two-stage valve type NE Two-stage valves are a type of pressure control valve. They are used in hydraulic systems that are supplied by dual stage pumps, a combination of high-pressure pump and low-pressure pump. The two-stage valve type NE combines the two pump delivery ows into a common volumetric ow. It switches the low-pressure pump to unpressurised circulation if the pressure value set is reached. It protects both pumps against exceeding the high or low-pressure value set. The two-stage valve type NE is used with directional valves to control doubleacting hydraulic cylinders. Features and bene ts: Operating pressures up to 700 bar Direct mounting on hydraulic power packs Direct combination with valve banks Two-stage valve type NE Intended applications: Presses Test benches Hydraulic tools 4/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

2 Available versions, main data Circuit symbol: NE 20 NE 21 NE 70 NE 80 Order coding example: NE 70-350/10 Pressure setting (bar) Basic type and size Table 1 Basic type and size Table 1 Basic type and size Coding NE 20 NE 21 Pressure range from... to (bar) Flow rate Q max (lpm) High pressure Low pressure High pressure Low pressure 20 to 500 20 to 700 NE 70 20 to 500 16 to 30 31 to 50 51 to 65 66 to 80 10 to 30 31 to 60 10 40 16 100 NE 80 20 to 500 10 to 30 25 180 Type NE 21 has the same design as type NE 20, but is suitable for direct mounting of valve banks type VB 11 G and VB 21 G in accordance with D 7302. Note the max. ow rates of the valve banks. HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 5/16

3 Parameters 3.1 General General information Designation Design Model Material Tightening torques Installation position Two-stage valve Combinations of ball-seated check valves with ball-seated and piston-type pressure-limiting valves Pipe connection Steel; nitrided valve housing, electrogalvanised sealing nuts and connection block, hardened and ground functional inner parts Steel; valve housing galvanized zinc plated; hardened and ground functional inner parts See Chapter 4, "Dimensions" As desired Line connection HP and A: pipe screw connection series S DIN 2353 / DIN EN ISO 8434-1 NP and R: pipe screw connection series L DIN 2353 / DIN EN ISO 8434-1 Hydraulic uid Hydraulic oil: according to Part 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s opt. operation approx. 10... 500 mm 2 /s. Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol) and HEES (synthetic ester) at operating temperatures up to approx. +70 C. Cleanliness level ISO 4406 21/18/15...19/17/13 Temperatures Ambient: approx. -40... +80 C, Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biologically degradable pressure uids: Observe manufacturer's specifications. By consideration of the compatibility with seal material not over +70 C. 6/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

Characteristic curves Oil viscosity approx. 60 mm 2 /s Δp-Q characteristics For viscosities above approx. 500 mm 2 /s, a stronger increase in the ow resistance must be taken into account. Sp ow resistance (bar); Q ow rate (lpm) Weight Type NE 20 NE 21 NE 70 NE 80 = 2.1 kg = 2.1 kg = 3.4 kg = 7.0 kg HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 7/16

4 Dimensions All dimensions in mm, subject to change. If the NE 21 is purchased without the VB 21G.. bank, the side channel outlets are sealed with an end plate. In the case of subsequent retro tting with VB 21G.., this end plate must be added to the end of the valve bank. NE 20 NE 21 1 Type NE 21 2 Valve bank type VB 11 or VB 21 in accordance with D 7302 For missing dimensions, see type NE 20 or D 7302 Ports ISO 228-1 (BSPP) NP, A, R HP M G 1/2 G 1/4 G 1/8 For attachment of a h VB 11G -- 48 VB 21G 22.5 35 8/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

NE 70 NE 80 Type Ports ISO 228-1 (BSPP) A, R HP NP NE 70 G 1 G 1/4 G 3/4 NE 80 G 1 1/4 G 3/8 G 1 HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 9/16

5 Assembly, operation and maintenance recommendations 5.1 Intended application This valve is intended exclusively for hydraulic applications ( uid engineering). The valve meets high technical safety standards and regulations for uid and electrical engineering. The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the speci c complete system must also always be observed. If the product can no longer be operated safely: Remove the product from operation and mark it accordingly. It is then not permitted to continue using or operating the product. 5.2 Assembly information The product must only be installed in the complete system with standard connection components that comply with market requirements (screw ttings, hoses, pipes, etc.). The hydraulic system must be shut down correctly prior to dismounting; this applies in particular to hydraulic systems with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance. 10/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

5.2.1 Attachment Attachment on mounting panel (example NE 70) 1 Flat washers to compensate for any unevenness For threaded holes in the housing body, see hole pattern Attachment on tank cover NE 20, NE 21 NE 70, NE 80 (example NE 70) 1 Abil seal NE 20: Order no. 7223 050 1 Abil seal NE 70: Order no. 7161 050 NE 80: Order no. 7181 050 Ports R, NP and HP enter directly from below Route high-pressure line through the tank cover to side HP port using bulkhead tting HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 11/16

Hole pattern NE 20, NE 21 NE 70, NE 80 Type #D #D1 a b c NE 70 36 38.5 44 20 26 NE 80 48.5 55 31 46 Hole pattern required in the lid for line connection holes (top view) 12/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

5.2.2 Subsequent pressure adjustment Always monitor the pressure gauge when setting or changing the pressure yourself. The speci ed pressure change values per revolution or per millimetre of adjustment travel at the adjusting spindle are only rough indicative values for approximately nding the desired operating pressure. Note To ensure that the low-pressure idle circulation functions correctly, make sure that the high-pressure setting is always above the low-pressure setting. This also applies if the intended high-pressure end value is not yet being used, for example, during commissioning of the hydraulic system. Monitor the pressure gauge. NE 20, NE 21 NE 70, NE 80 1 Perforated washer 2 Tapped plug 3 Lock nut SEAL-Lock 4 Setting screw High-pressure adjustment: Loosen lock nut (at least 1 1/2 turns in order to free the vulcanized sealing lip from the thread turns). Turn setting screw with a screw driver: Clockwise = pressure increases 1 revolution, 100 bar (pressure range 20 to 500 bar) 1 revolution, 170 bar (pressure range 20 to 700 bar) and lock again. Low-pressure adjustment: Unscrew tapped plug and add or remove perforated washers #16x#10x1 1 Lock nut 2 Setting screw 3 Hex spring housing 4 Washers High-pressure adjustment: Loosen lock nut Turn setting screw with a screw driver: Clockwise = pressure increases 1 revolution, 80 bar (pressure range 20 to 500 bar) and lock again. Low-pressure adjustment: Unscrew spring housing. Remove washers as required = pressure falls; or add washers = pressure increases 1 mm, 2.5 bar (Pressure range 16 to 30 bar) 1 mm, 5 bar (Pressure range 31 to 50 bar) 1 mm, 9 bar (Pressure range 51 to 65 bar) 1 mm, 11 bar (Pressure range 66 to 80 bar) Switching point can be checked at M with a pressure gauge Type Coding for washers NE 70 5650 005 (0.5 mm thick) NE 80 Washer 13 DIN 125 (2.5 mm thick) Pressure change per washer Approx. 4 bar Approx. 2.5 bar Caution Risk of injury on overloading components due to incorrect pressure settings! Risk of minor injury. Always monitor the pressure gauge when setting and changing the pressure. HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 13/16

5.3 Operating instructions Product configuration and setting the pressure and ow rate The statements and technical parameters in this documentation must be strictly observed. The instructions for the complete technical system must also always be followed. Note Read the documentation carefully before usage. The documentation must be accessible to the operating and maintenance staff at all times. Keep documentation up to date after every addition or update. Caution Risk of injury on overloading components due to incorrect pressure settings! Risk of minor injury. Always monitor the pressure gauge when setting and changing the pressure. Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of a hydraulic power pack. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Pay attention to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters".) 5.4 Maintenance information This product is largely maintenance-free. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year. 14/16 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE

6 Other information Application examples Type NE 21 with valve bank VB 21 G. (D 7302); mounted on compact hydraulic power pack type MP (D 7200 H) Use of an NE 70 in a hydraulic mould closing device Example: MP 44A - H1.4 Z16 / B55 - NE 21-700/20 - - VB 21GM - RH-3G-G 24 1 Stroke 2 Type DG 1 in accordance with D 5440 3 Type RH 5V in accordance with D 6105 4 Type SG 5H - MD 3/.. in accordance with D 5650/1 5 Two-stage valve type NE 70 6 Type RZ 8.3/59 / B100-V5.5 - NE 70-200/20 in accordance with D 6010 H HAWE Hydraulik SE D 7161 - NE - 03-2017-1.0 15/16

Further information Additional versions Pressure-controlled shut-off valve type CNE: D 7710 NE Connection blocks type A for hydraulic power packs: D 6905 A/1 Valve bank (directional seated valve) type VB: D 7302 Switch unit type CR: D 7150 Compact hydraulic power pack type MPN and MPNW: D 7207 Dual-stage pump type RZ: D 6910 D 7161 - NE - 03-2017-1.0 HAWE Hydraulik SE Streitfeldstraße 25 81673 München Postfach 80 08 04 81608 München Germany Tel +49 89 379100-1000 Fax +49 89 379100-91000 info@hawe.de www.hawe.com