Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Similar documents
Hydraulics. Hydraulic Pressure Control

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

[You may download this article at: ]

Introduction. Part one: Identify the Hydraulic Trainer Components

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

ATM 322 Basic Pneumatics H.W.6 Modules 5 7

Lesson 6: Flow Control Valves

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Basic Pneumatics. Module 7: Time delay valve and sequence control systems. Academic Services PREPARED BY. January 2013

ANTI SHOCK RELIEF VALVE

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Unit 24: Applications of Pneumatics and Hydraulics

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Basic Pneumatics. Module 9: Time delay valve. Academic Services PREPARED BY. April 2012

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Priority (Swing) Motors Data and Specifications

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Lecture 26 HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

Chapter 10: Bidirectional Flow Controls

Directional Control valves

Introduction to Pneumatics

Time-Delay Electropneumatic Applications

Electrically Operated Pressure-Relief Cartridge, Size 10

2015 Fluid Power Innovation & Research Conference (FPIRC 15) Empirical Method for Determining CB Efficiency and Stability

Leak free Pipe Rupture Valve for Excavators

(Refer Slide Time: 0:26)

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Leak-Free Load-Control Valve SAE ½ psi flange

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

PTS1120TSJB PTS2120TSTSJB

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

The University of Jordan. School of Engineering. Mechatronics Engineering Department

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Directional Controls

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

VACUUM REGULATORS CONTENTS

Smooth Vent Valve XVD. Series

HYDRAULIC CYLINDER TEST

Smooth Vent Valve. XVD Series

Directional Controls

Inverse Proportional Pressure-Relief Cartridge, Size 10

Double Pilot Operated Cartridge Check Valve, Size 8

Pilot Operated Check Valves Catalog Quick Reference

PRESSURE SEQUENCE VALVE TYPE UZK

SystemStak Valves. ISO4401 Size 02

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

Pressure on Demand. Air Pressure Amplifiers

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Specifications. Model VEX Operating style Fluid Proof pressure Max. operating pressure

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 2300 Units

Hydraulic Punch Drivers

Cartridges for pressure relief functions Hard seated ND 16 to 32 for water and oil up to 350bar

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Waterous Relief Valve

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Ball valve-combinations 105 Shut-off blocks with integrated bypass and safety-lock 106 Sandwich plates 108 Accumulator safety blocks 114

IFP C175-* REMOTE CONTROL RELIEF VALVE

BERMAD Waterworks. Level Control Valve. with Bi-Level Vertical Float. 700 Series. Major Additional Features. Features and Benefits.

Section 4: Sequence valve adjustments

Cover headline. Cover subheadline. Check Valves

Discharge Relief Valve Operation & Maint.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

INSTALLATION OPERATION MAINTENANCE

WORKHOLDING APPLICATION BOOKLET

SERVICE INSTRUCTIONS P-C SINGLE PRESSURE - SOFT START, SERIES F1U CONTROL

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

WATER HYDRAULIC SYSTEM FOR HIGH SPEED CYLINDER DRIVE

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. August 2015

Learning System for Automation and Communications. Hydraulics. Workbook Basic Level

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. November2015

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Full Range Pressure Compensating Variable Flow Control

CALEFFI. Ball zone valves. series /03 GB

SERVICE INSTRUCTIONS P-2 DUAL PRESSURE COMPENSATOR, SERIES F1U CONTROL

Safety Beyond the Electrics

EXH. Specifications. Descriptions. Min. working pressure MPa

SERVICE INSTRUCTIONS P-A OR P-B ELECTRONIC PRESSURE COMPENSATOR, SERIES F1U CONTROLS

Max operation pressure 6kg/cm 2. Boost pressure rate Air pressure supply 5kg/cm Hydraulic fluid expelled l/min

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Technical Data Sheet TI-F50 Locking Units series KFH

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow meter. bellow vaporizer. APL valve. Scavenging system

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

IWCF Equipment Sample Questions (Surface Stack)

Removal of hydraulic load holding valve incident causing injury

Case History. North Sea Platform Wellhead Isolation Tubing Hanger Body Seals Locking Device 20-3/4 x 13-3/8 Mandrel Neck Seal

The Size 16 Product Range

SERVICE MANUAL No. I-0043

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

SEMEM3-73 Maintaining medical gas pipeline systems and equipment

Integrating Safety and Automation

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

Transcription:

Lecture 19 PRESSURE-CONTROL VLVES [CONTINUED] 1.5 Counterbalance Valve Schematic diagram of counterbalance valve is shown in Fig. 1.14. These normally closed valves are primarily used to maintain a back pressure on a vertical cylinder to prevent it from falling due to gravity. They are used to prevent a load from accelerating uncontrollably. This situation can occur in vertical cylinders in which the load is a weight. This can damage the load or even the cylinder itself when the load is stopped quickly at the end of the travel. Spring Spring Figure 1.14 Counterbalance valve. valve s primary port is connected to the cylinder s rod end and the secondary port to the directional control valve. The pressure setting is slightly higher than that required to keep the load from free-falling. When the pressurized fluid flows to the cylinder s cap end, the cylinder extends, increasing pressure in the rod end and shifting the main spool in the counterbalance valve. This creates a path that permits the fluid to flow through the secondary port via the directional control valve and to the reservoir. s the load is raised, the integral check valve opens to allow the cylinder to retract freely. If it is necessary to relieve back pressure at the cylinder and increase the force at the bottom of the stroke, the counterbalance valve can be operated remotely. Counterbalance valves are usually drained internally. When the cylinder extends, the valve must open and its secondary port should be connected to the reservoir. When the cylinder retracts, it matters little that load pressure is felt in the drain passage because the check valve bypasses the valve s spool. Graphic symbol of a pressure-reducing valve is shown in Fig. 1.15.

Figure1.15 Symbolic representation of a counterbalance valve. 1.5.1pplication of a Counterbalance Valve Counterbalance valve W Figure 1.16pplication of a counterbalance valve. Counterbalance valves are commonly used to counterbalance a weight or external force or counteract a weight such as a platen or a press and keep it from freefalling.figure1.16 illustrates the use of a counterbalance or back-pressure valve to keep a vertically mounted cylinder in the upward position while the pump idles, that is, when the DCV is in its center position. During the downward movement of the

cylinder, the counterbalance valve is set to open at slightly above the pressure required to hold the piston up (a check valve does not permit flow in this direction). The control signal for the counterbalance valve can be obtained from the blank end or rod end of the cylinder. If derived from the rod end, the pressure setting of the counterbalance valve equals the ratio of the load to the annulus area of the piston. If derived from the blank end, the pressure setting equals the ratio of load to the area of piston. This pressure is less and hence usually it has to be derived from the blank end. This permits the cylinder to be forced downward when pressure is applied on the top. The check valve is used to lift the cylinder up as the counterbalance valve is closed in this direction. The directional control valve unloads the pump. 1.6 Source of Pilot Pressure in Counterbalance Valves When a counterbalance valve is used in large vertical presses, it may be important to analyze the source of pilot operating pressure. Figure 1.17 shows a comparison between direct pilot and remote pilot operation. Through the application of Pascal s law, we have Force 35000 p 55 bar 4 rea 65 10 If the pilot pressure is taken directly, then the counterbalance valve operates at about 55 bar or slightly higher because of inertia and friction. In the other case, where the remote pilot pressure is taken from the pressure line at the top of the cylinder, a choice of operating pressure can be made for the valve. counterbalance valve is normally a closed valve and remains closed until acted upon by the remote pilot pressure source. Therefore, a much lower spring force can be selected to allow the valve to operate at a lesser pilot pressure. It should also be noted that the press load cannot move downward unless flow from the pump is directed into the top of the cylinder, which isa normal function of the machine. From the 130 cm 2 From the pump 130 cm 2 To the 65 cm 2 To the tank 65 cm 2 35000 N 55 + bar (a) (b) Figure 1.17(a) Direct pilot and (b) remote pilot.

1.7 Pressure Sequence Valve sequence valve is a pressure-control valve that is used to force two actuators to operate in sequence. They are similar to pressure-relief valves. Schematic diagram of sequence valve is shown in Fig. 1.18. Instead of sending flow back to the tank, a sequence valve allows flow to a branch circuit, when a preset pressure is reached. The check valve allows the sequence valve to be bypassed in the reverse direction. The component enclosure line indicates that the check valve is an integral part of the component. The sequence valve has an external drain line; therefore, a line must be connected from the sequence valve s drain port to the tank. The symbol for a sequence valve is shown in Fig. 1.19. Drain In Secondar y port Out Direct pilot Remote pilot Figure 1.18Sequence valve. Figure 1.19Sequence valve with a check valve. 1.7.1 pplication of a Sequence Valve The hydraulic circuit shown in Fig. 1.20 is an example of an application of a sequence valve in which a clamp cylinder extends first to hold a workpiece and then a second cylinder extends to bend the workpiece in the desired shape.

Sequence valve 1 ending cylinder () Clamp cylinder () Sequence valve 2 W Figure 1.20pplication of a sequence valve. In this circuit, two cylinders are connected in parallel. Without the sequence valve, these cylinders would extend together as they are both unloaded. In order for this circuit to function properly, the clamp cylinder must extend completely before the bending cylinder begins to extend. The sequence valve accomplishes this by not allowing flow into the bending cylinder branch of circuit until the clamp cylinder has reached the end of its stroke. When the clamp cylinder extends completely, the pressure rises and opens the sequence valve,thus allowing the bending cylinder to extend. The sequence valve must be set high enough so that it opens only after the complete extension of the clamp cylinder. During the retraction of cylinders, the check valve allows the sequence valve to be bypassed. The sequence valve has no effect on the circuit in this situation. oth cylinders retract together because both are unloaded and split the pump flow. 1.8 Cartridge Valves Cartridge valves consist of a valve shell that can be mounted in a standard recess in a valve block or manifold. The machine manufacturer does not have to worry about tolerances of moving spools and poppets because these are taken care by the hydraulic valve manufacturer. This is very advantageous for

batch production and modularized packages or integrated circuits. Cartridge valves eliminate expensive and potentially leaking pipework and connectors.cartridge valves can be used as follows: 1. Leak-proof direction control valve. 2. Check valve to obtain unidirectional flow. 3. Throttle valve to control and limit the rate of flow. The valve shell or body has two main ports ( and ) that are connected or separated by a poppet or a spool. The poppet-type cartridge valve is basically a check valve that can be pilot operated in a number of ways, whereas the spool-type cartridge valve is used as a variable restrictor that is either normally open or closed by the action of the control or vice versa. The actions of the two types of cartridge valvesare completely different. 1.8.1 Poppet-Type Cartridge Valves In some designs, a poppet fits into cavity and is held in position by a cover or a top plate that contains all pilot connections. Others are designed to fit the standard cavities used by some conventional cartridge valves. Logic elements that have a balanced poppet or spools can be modulated and are largely used as pressure controls. Those with unbalanced poppets are primarily used for switching functions such as directional controls or where the poppet movement can be limited as flow controls. The principal advantages of poppet-type valves are as follows: 1. very high flow rate for a relatively small physical size. 2. positive seal can be obtained. 3. May be extremely rapid acting but can also be easily adopted for soft switching. 4. The shape of the poppet or spool together with its seat can be varied to give different operating characteristics to the valve assembly. The major disadvantage is that unbalanced poppets, being responsive to pressure changes on all ports, may malfunction owing to pressure surges. Particular care has to be taken in the circuit design to ensure the safe operation. The opening and closing movements of the poppet in a cartridge valve are pressuredependent and a function of the forces in these areas: Effective area of the poppet at port Then Effective area of the poppet at port Effective area of the poppet at port X X X In a balanced poppet-type shown diagrammatically and symbolically in Fig.1.21, 0 and the areas Xand are equal.pilot X controls the function of the valve. If X is connected to port, the valve operates as a check valve allowing flow from to by opening the poppet but preventing flow from to by closing the poppet. If port X is connected to the external pressure, the valve can be used to control closing or opening pressure.

x X Figure 1.21alanced poppet cartridge valve area ratio,. In an unbalanced poppet-type valve shown diagrammatically and symbolically in Fig.1.22, it is possible to obtain a different area ratio, typically : 1:1.1, where 0.1 X : 1:1.05, where 0.05 X : 1: 2, where X X X X

Figure 1.22Unbalanced poppet cartridge valve area ratio,. X With the pilot X vented, pressure at port or has to overcome the bias spring force only for flow in either direction. However, it can be held closed by a pressure on the pilot port that is dependent on the poppet area ratios. Figure 1.23 shows how a large double-acting cylinder can be controlled using cartridge valves. small double-solenoid-operated directioncontrol valve feeds pilot pressure signals to four cartridge valves that are coupled in pairs to each end of the double-acting cylinder. One cartridge valve from each pair is permanently connected to the tank drain line and the other to the pump pressure line. In the position drawn, all the four valves are held closed by the pilot pressure signals and the cylinder position is locked. When solenoid is energized, pilot pressure is maintained on valves 1 and 3 which remain closed. ut valves 2 and 4 are released and open under the influence of fluid pressure in the main system. The fluid under pressure, therefore, flows from the pump through the cartridge valve to the piston side of the cylinder and the cylinder extends. The fluid from the rod end of the cylinder flows through valve 4 back to the tank. When solenoid is energized, cartridge valves 2 and 4 are closed under pilot pressure and valves 1 and 2 are released, causing the cylinder to retract. T 1 2 3 4 T Figure 1.23 Control of a double-acting cylinder using cartridge logic valves.

Objective-Type Questions Fill in the lanks 1. relief valve is similar to a in an electrical system. 2. pilot-operated pressure relief valve consists of a small and a main relief valve. 3. is used to maintain reduced pressures in specified locations of hydraulic systems. 4. is used to maintain a back pressure on a vertical cylinder to prevent it from falling due to gravity. 5. pilot-operated unloading relief valve is the same as a pilot-operated relief valve with the addition of an spool. State True or False 1. Pressure-relief valves limit the maximum pressure in a hydraulic circuit by providing an alternate path for fluid flow when the pressure reaches a preset level. 2. pilot-operated pressure-relief valve cannot be operated using a remote. 3. common application of an unloading valve is in high low pump circuits and punching press. 4. Sequence valves are similar to pressure-relief valves. 5. n unloading valve requires electric signals. Review Questions 1. Explain the function of pressure-control valves in hydraulic power systems. 2. Discuss in detail the static characteristics of a direct-operated relief valve, and explain how to reduce the over-ride pressure. 3. Draw schematically a pilot-operated relief valve and explain its function. 4. Discuss the application of a pilot-operated relief valve. 5. Discuss the principle of pressure reduction in fluid power systems. 6. Discuss briefly the operation of a pilot-operated pressure reducer. 7. Explain the function of a direct-operated sequence valve. 8. What are the differences between relief and sequence valves? 9. Discuss the application of a sequence valve used in hydraulic systems. 10. Name two applications of a counterbalance valve. 11. What is the function of a sequence valve? 12. What is the function of an unloading valve? 13. How is the unloading valve different from a pressure relief valve? 14. What is the function of a pressure relief valve in fluid power systems? 15. What is the advantage of using an unloading circuit when feed and speed of a machine need to be varied?

nswers Fill in the lanks 1.Fuse 2.Pilot relief valve 3.Pressure-reducing valve 4.Counterbalance 5. Unloading State True or False 1.True 2.False 3.True 4.True 5.False