Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Operation Maintenance

Installation, Operation, & Maintenance Manual NX Seal Cooler

Mechanical Seal Piping Plans

Mechanical Seal Piping Plans

Improved Mean Time Between Planned Maintenance (MTBPM) for Mechanical Seals in Process Pumps

INSTALLATION, OPERATION & MAINTENANCE GUIDE

4400 TwinHybrid Gas Seal

John Crane Type 609HTC/ECS (High-Temperature Corrosion Resistant) Sealol Metal Bellows Seal Installation Instructions

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

Models: C62/63/64-A/D

Engineering Data Sheet

TITAN FLOW CONTROL, INC.

WHEATLEY Series 500 Swing Check Valve

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

1 DRIVE INDUSTRIAL IMPACT WRENCH

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Mechanical Seal Piping Plans

GREIG FILTERS, INC. OPERATION MANUAL

INSTRUCTION MANUAL. Anchor Darling 800 Globe Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

FLANGED TWO-PIECE BALL VALVES

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

4400H TwinHybrid Gas Seal

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Anti-flood device Model B-1

Edward Valves Equiwedge Forged Gate Valve

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

RS(H)20, 25 USER MANUAL

Dean Pump Self-Priming Chemical Process Pumps

Booster Pump PB4-60 Replacement Kits

Types 749B and R130 Changeover Manifolds

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

FLANGED TWO-PIECE BALL VALVES

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

Installation Instructions, Pressure Regulator Series

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

WHEATLEY Series 822/820 Swing Check Valve

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

BUTTERFLY VALVES Series 800

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

Pressure Dump Valve Service Kit for Series 3000 Units

INSTALLATION, OPERATION and MAINTENANCE MANUAL

TITAN FLOW CONTROL, INC.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Produc. Atmosph. here

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Constant Pressure Crude Oil Container Model CPCCP

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

VALVES & MEASUREMENT

Pressure Dump Valve Service Kit for Series 2300 Units

SECTION BUTTERFLY VALVES

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Type CT88 Backpressure Regulator

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Techcon Systems TS1254 Pressure Pot

3/8" Dr. Air Butterfly Impact Wrench

Installation Troubleshooting Maintenance Instructions Installation / Start-up

FLANGED MULTI-PORT BALL VALVES

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Preparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat 7I Insert, Full Bolted, and Union Type Holders

Eaton Filtration, LLC

APP pumps APP and APP Disassembling and assembling

1.0 - OPENING AND CLOSING THE DOOR

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Operating instruction

// ADapters GUIDelines

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE

Transcription:

Installation Instructions BW Seals Uniseal Series Cartridge metal bellows single and dual seals Experience In Motion

Description The Uniseal metal bellows seal series consists of: Uniseal I - Single seals for standard bore seal chambers Uniseal I Plus - Single seals for enlarged bore seal chambers Uniseal II - Dual seal for standard bore seal chambers Uniseal II Plus - Dual seal for enlarged bore seal chambers 1 Equipment Check 1.1 Follow plant safety regulations prior to equipment disassembly including, but not limited to, the following: Lock out motor and valves. Wear designated personal safety equipment. Relieve any pressure in the system. Consult plant MSDS files for hazardous material regulations. 1.2 Disassemble pump in accordance with equipment manufacturer s instructions and remove sealing arrangement. 1.3 Check seal documentation for seal design and materials of construction. Verify that the Uniseal is designed for the equipment being repaired. 1.4 Check seal assembly drawing for any modifications required to the equipment before installation and act accordingly. 1.5 Check shaft or pump sleeve OD, seal chamber depth, seal chamber bore, distance to the first obstruction, gland pilot and gland bolting to ensure they are dimensionally within the tolerances shown on the seal assembly drawing. Check gland bolt length to ensure adequate thread engagement for the actual seal gland. 1.6 Thoroughly inspect and clean the seal chamber and shaft or pump sleeve. Inspect for corrosion or any defects. Remove all burrs, cuts, dents or defects that might damage gaskets or allow a leak path. Replace worn shaft or pump sleeve. Remove sharp edges from keyways and threads. 1.7 Check equipment requirements as described in Figure 1. Any reading greater than what is allowed must be brought within specifications. 1.8 Handle the Uniseal with care; it is manufactured to precise tolerances. The seal faces are of special importance and should be kept perfectly clean at all times. 1.9 Tools needed for installation: An open-end wrench and torque wrench sized for the gland bolt nuts; a torque wrench for the set screws. All other tools are provided. The images of parts shown in these instructions may differ visually from the actual parts due to manufacturing processes that do not affect the part function or quality. 2

Seal Chamber Requirements Figure 1 To first obstruction Face of seal housing to be square to the axis of the shaft to within 0.013 mm per millimeter (0.0005 inches) of seal chamber bore FIM and have a 1.6 μm (63 μinch) R a finish or better Seal housing bore to have 3.2 μm (125 μinch) R a finish or better Sleeve or shaft finish to be 0.8 μm (32 μinch) R a or better 2 Uniseal Installation Gland pilot can be at either of these register locations, concentric to within 0.13 mm (0.005 inch) FIM of shaft or sleeve OD Shaft or sleeve OD +0.000 mm (+0.000 inch) -0.050 mm (-0.002 inch) ANSI +0.000 mm (+0.000 inch) API 610/682-0.025 mm (- 0.001 inch) DIN/ISO Bearings must be in good condition Maximum lateral or axial movement of shaft (end play) = 0.25 mm (0.010 inch) FIM Maximum shaft runout at face of seal housing = 0.05 mm (0.002 inch) FIM Maximum dynamic shaft deflection at seal housing = 0.05 mm (0.002 inch) FIM Note: No seal setting measurements are needed to install the seal. Instructions are for end-suction back pull-out pumps. Modification of these procedures may be required for other style pumps. Consult Flowserve for installation support. 2.1 Lubricate the shaft or pump sleeve lightly with silicone lubricant unless otherwise specified. 2.2 Tighten the setting device cap screws to ensure they are tight before installation. 2.3 Slide the Uniseal cartridge onto the shaft or pump sleeve with the setting devices toward the bearing housing. See Figure 2. 2.4 Install the seal chamber and bolt it in place on the bearing frame. See Figure 3. 2.5 Position the Uniseal with the gland tight against the seal chamber. Bearing Frame Bearing Housing Seal Chamber Setting Device Figure 3 Figure 2 3

2.6 Orient the Uniseal with the ports aiming as shown on the seal assembly drawing. See Section 3 for Piping Recommendations. 2.7 Tighten the gland nuts evenly in a diagonal sequence. Do not overtighten the gland nuts, as this can warp seal parts and cause leakage. Confirm adequate thread engagement before final torque setting. Recommended Uniseal minimum gland nut torque by size range: Seal mm 25-50 54-67 Size (inch) (1.000-2.000) (2.125-2.625) Torque 20 N-m 27 N-m (15 ft-lbs) (20 ft-lbs) 2.8 Assemble the equipment per manufacturer specifications. Avoid pipe strain. Align the coupling per manufacturer specifications. 2.9 With the impeller, shaft, coupling and bearings in their final operating position, tighten the drive collar set screws. See Figure 4. Recommended Uniseal minimum set screw torque by size range: Seal mm 25-60 67 Size (inch) (1.000-2.500) (2.625) Torque 4.5 N-m 13.5 N-m (40 in-lbs) (120 in-lbs) Figure 4 Figure 5 2.10 Remove the setting devices from the drive collar by loosening the cap screws. See Figure 5. Save the setting devices and fasteners for future use when the pump impeller is reset or when the seal is removed for repairs. 2.11 Turn the shaft by hand to ensure unobstructed rotation. 2.12 See Operational Recommendations before start-up. 4

3 Piping Recommendations 3.1 Install and maintain an adequate piping plan. The Uniseal requires a clean, cool environment for maximum seal life. Typical piping plans are listed below. Contact Flowserve for additional piping plan information or technical support. Plan 11: Plan 13: Plan 21: Plan 32: Plan 52: Plan 53: Plan 62: default inner seal flush from pump discharge on horizontal pumps (single seals) default inner seal flush and vent from pump suction on vertical pumps (single seals) inner seal flush from pump discharge through a cooler for use with hot products (single seals) inner seal clean external flush for use with abrasive products or products that are incompatible with the seal (single seals) dual seal circulation through a low pressure reservoir (dual seals) dual seal circulation through a pressurized reservoir (53A), finned tube array (53B) or Q piston accumulator (53C) (dual seals) external quench on atmospheric side of F F seal (single seals) a b 3.2 For single seals, follow the port connections listed below, see Figure 6. Quench and Drain ports on single seals should be plugged if not used as a good housekeeping practice. For Plans 11, 21 and 32: Shaft Rotation Inlet Plugged (from exposed end of gland) Port Clockwise (CW) Port b Port a Counterclockwise (CCW) Port a Port b For Plan 13: Shaft Rotation Outlet Plugged (from exposed end of gland) Port Clockwise (CW) Port a Port b Counterclockwise (CCW) Port b Port a CCW Rotation D CW Rotation Single seal port connections Figure 6 5

3.3 For dual seals, follow the port connections listed below, see Figure 7. Uniseals are unidirectional and piping the correct inlet and outlet is important to proper circulation. The liquid barrier inlet should draw from the bottom of the support system while the liquid barrier outlet feeds the top of the system. After venting, plug the vent port. F CCW Rotation a V CW Rotation b F Dual seal port connections Figure 7 For Plans 52 and 53: Shaft Rotation Inlet Outlet (from exposed end of gland) Clockwise (CW) Port b Port a Counterclockwise (CCW) Port a Port b 3.4 For dual pressurized seal (double seal) operation, supply a clean, compatible barrier fluid at a pressure at least 1.7 bar (25 psi) above the seal chamber pressure. See Figure 8. The pressure of the barrier fluid must not exceed the recommended maximum pressure. Dual pressurized (Plan 53A) Uniseal with Supply Tank Figure 8 Image is not to scale 6

3.5 For dual unpressurized (tandem seal) operation, supply a clean, compatible buffer fluid at a pressure below the seal chamber pressure. The pressure in the seal chamber must not exceed the recommended maximum pressure. 3.6 Dual seal recommendation: For enhanced seal performance and reduced coking, use DuraClear as a barrier fluid. Refer to DuraClear brochure FSD123 or contact a Flowserve representative for further details. 4 Operational Recommendations 4.1 Remove lock outs on equipment and valves. 4.2 Do not start up the pump dry to check motor rotation or for any other reason. Open valves to flood pump with product fluid. Ensure that the seal flush or support system is operating. Vent air from the casing of the pump and the seal chamber before start-up. 4.3 Observe the start-up. If the seal runs hot or squeals, check the seal flush system. Do not allow the pump to run for any extended time if the seal gets hot or squeals. 4.4 Do not exceed corrosion limits. The Uniseal is designed to resist corrosion through proper material selection. Do not expose the Uniseal materials of construction to products outside of their corrosion limits. Consult Flowserve for chemical resistance recommendations. 4.5 Do not exceed pressure and speed limits established for the Uniseal. 4.6 Do not exceed the temperature limits of the Uniseal based on the materials of construction. For dual seals using supply tanks with cooling coils, turn on cooling water to the supply tank before start-up. 4.7 Do not start up or run the Uniseal dry. The seal chamber, pump and support systems should be thoroughly vented before start-up. Buffer or barrier fluid must flood the seal cavity of dual seals at all times during operation. Process fluid must be in the seal chamber at all times during single seal operation. 7

TO REORDER REFER TO B/M # F.O. 5 Repairs This product is a precision sealing device. The design and dimension tolerances are critical to seal performance. Only parts supplied by Flowserve should be used to repair a seal. To order replacement parts, refer to the part code and B/M number. A spare backup seal should be stocked to reduce repair time. When seals are returned to Flowserve for repair, decontaminate the seal assembly and include an order marked "Repair or Replace." A signed certificate of decontamination must be attached. A Material Safety Data Sheet (MSDS) must be enclosed for any product that came in contact with the seal. The seal assembly will be inspected and, if repairable, it will be rebuilt, tested, and returned. FIS213eng REV 05/13 Printed in USA To find your local Flowserve representative and find out more about Flowserve Corporation, visit www.flowserve.com USA and Canada Kalamazoo, Michigan USA Telephone: 1 269 381 2650 Telefax: 1 269 382 8726 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2013 Flowserve Corporation Europe, Middle East, Africa Roosendaal, the Netherlands Telephone: 31 165 581400 Telefax: 31 165 554590 Asia Pacific Singapore Telephone: 65 6544 6800 Telefax: 65 6214 0541 Latin America Mexico City Telephone: 52 55 5567 7170 Telefax: 52 55 5567 4224 flowserve.com