Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Similar documents
Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Two-stage valve type NE

Pressure-controlled shut-off valve type CNE

Pressure-reducing valve type CDK

Diaphragm accumulator type AC

Pressure reducing valves type CDK

Diaphragm accumulator type AC

Over-center valves type LHT with oscillation damping, zero leakage

Pressure reducing valve, direct operated

Pressure reducing valve, pilot operated

Check valve hydraulically pilot operated

Pressure reducing valve, direct operated

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure relief valve, direct operated

Pressure reducing valve, pilot operated, Model 3DR

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Inverse Proportional Pressure-Relief Cart., Size 2 4

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Inverse Proportional Pressure-Relief Cartridge, Size 10

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

3-Way Safety Block DSV

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

1200B2 Series Service Regulators. Instruction Manual

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

MANUAL. Sesame. Thermoplastic Tank Technologies

OPERATING INSTRUCTIONS

Inverse Proportional Pressure-Relief Cart., Size 2 4

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Pressure-Relief Cartridge Valve, Size 4

Operation Manual Air Saver Unit ASV5000 Series

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

3-Way Pressure-Reducing Cartridge, Size 2 4

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Inverse Prop. Pressure-Relief Cart., Size 2 4

WW-720. Pressure Reducing Control Valve

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

FPD20 Series. Gear wheel flow sensor

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

1800C and 1800C-HC Series Service Regulators

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

HPB25 Hydraulic Paving Breaker

Manual Actuated Boiler Blowdown Valves

Pressure relief valve, direct operated Type DBD

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Leak free Pipe Rupture Valve for Excavators

Electrically Operated Pressure-Relief Cartridge, Size 10

Hydraulic Punch Drivers

Universal Charging and Testing Unit FPU-1

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Pressure maintenance valve SDV-P / SDV-P-E

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

180 Series Rotary Shear Directional Control Valve

Leak-Free Load-Control Valve SAE ½ psi flange

DK ton, Double-acting, Die-type Crimping Tool

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Technical Data Sheet TI-F52 Locking Unit KFHL Certified by Lloyd s Register

Pressure Reducing Valve DMV 750 set range: bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

WW-720. Pressure Reducing Control Valve

Operating and maintenance manual Filter and reducing station Series / 1.0

Overview of types. Technical data. Safety notes

Pressure relief valves

USER MANUAL. MACMAG magnetic separator MHK MHF

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Regulator from 1800 B series

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Safety and Shut-off Block SAF/DSV

Peak Pressure Indicator MSI-3

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

INSTRUCTION MANUAL Pressure Relief Device LPT

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

Transcription:

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3

by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document generated on: 06.03.2018 2/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

Contents 1 Overview of pressure-limiting valve and pre-load valve type MVG, MVE and MVP... 4 2 Available versions, main data... 5 3 Parameters... 7 4 Dimensions... 9 5 Assembly, operation and maintenance recommendations...11 5.1 Intended use... 11 5.2 Assembly information... 11 5.3 Operating instructions...12 5.4 Maintenance information...12 5.5 Adjusting the valve... 13 6 Appendix...14 6.1 Typical application examples...14 HAWE Hydraulik SE D 3726 - MVG, MVE, MVP - 02-2016-1.3 3/15

1 Overview of pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valves and sequence valves are types of pressure control valves. Pressure-limiting valves safeguard the system against excessive system pressure or limit the operation pressure. Sequence valves generate a constant pressure difference between the inlet and outlet ow. Type MV is a directly controlled valve that is damped as standard. Features and bene ts: Operating pressures up to 700 bar Various adjustment options Numerous configurations Valve for pipe connection type MVG Intended applications: General hydraulic systems Test benches Hydraulic tools Valve for manifold mounting type MVP Screw-in valve type MVE 4/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

2 Available versions, main data Circuit symbol: MVG, MVP, MVE Pressure-limiting valve Fixed Adjustable or Sequence valve Fixed MVGC Sequence valve Fixed only Order coding example: MVE 14 M R - 120 Pressure setting (see also note for Table 1) Adjustment Table 2 Adjustment Basic type and size Table 1 Basic type and size HAWE Hydraulik SE D 3726 - MVG, MVE, MVP - 02-2016-1.3 5/15

Table 1 Basic type and size Basic type and size Pressure range (bar) MVG 13 H 20... 700 MVG 13 M 20... 400 MVG 14 H 10... 400 MVG 14 M 0... 200 MVG 14 N 0... 50 MVP 13 H 20... 700 MVP 13 M 20... 400 MVP 14 H 10... 400 MVP 14 M 0... 200 MVP 14 N 0... 50 MVE 13 H 20... 700 MVE 13 M 20... 400 MVE 14 H 10... 400 MVE 14 M 0... 200 MVE 14 N 0... 50 MVGC 14 M 0... 200 MVGC 14 N 0... 50 Flow rate (lpm) 5 8 5 8 5 8 Connection type Valve for pipe connection: Ports P and R = G 1/4 (BSPP) Valve for manifold mounting: For dimension drawing see Chapter 4, "Dimensions" Screw-in valve: For mounting hole see Chapter 4, "Dimensions" Valve for pipe connection: Ports F and V = G 1/4 (BSPP) Brief description Valve for one ow direction (working direction) Valve for two ow directions (working direction and free return ow) Note Pressure setting If there is no pressure specification, the factory settings are: MV.. 13 H MV.. 13 M MV.. 14 H MV.. 14 M MV.. 14 N 400 bar 200 bar 400 bar 200 bar 30 bar Table 2 Adjustment Coding No designation R F Description Series, xed (tool adjustable) Manually adjustable Pin head; not for type MVGC Note During use as a sequence valve, the permissible pressure in the re ux must not exceed 400 bar! Adjustability under pressure over approx. 100 bar with coding R and F no longer possible. Adjustment should therefore only be carried out in pressureless state! 6/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

3 Parameters General General data Description Design Model Material Installation position Pressure-limiting valve Cone-seated valve According to type Steel; nitrided valve housing, electrogalvanised sealing nuts and connection block, hardened and ground functional inner parts Balls made of rolling bearing steel Steel; valve housing galvanized zinc plated; hardened and ground functional inner parts As desired Hydraulic uid Hydraulic oil: according to part 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s opt. operation approx. 10... 500 mm 2 /s. Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol) and HEES (synthetic ester) at operating temperatures up to approx. +70 C. Cleanliness level ISO 4406 21/18/15...19/17/13 Temperatures Ambient: approx. -40... +80 C, Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biologically degradable pressure uids: Observe manufacturer's specifications. By consideration of the compatibility with seal material not over +70 C. Weight Type MVG MVP MVE MVGC = 0.3 kg = 0.3 kg = 0.1 kg = 0.3 kg HAWE Hydraulik SE D 3726 - MVG, MVE, MVP - 02-2016-1.3 7/15

Characteristic curves Oil viscosity approx. 60 mm 2 /s Δp-Q characteristics MVG 14 N MVG 14 M Q ow rate (lpm); Sp ow resistance (bar) MVG 14 H Q ow rate (lpm); Sp ow resistance (bar) MVG 13 H Q ow rate (lpm); Sp ow resistance (bar) Q ow rate (lpm); Sp ow resistance (bar) Q ow rate (lpm); Sp ow resistance (bar) N actuation force for pin head; p operating pressure (bar) 1 Flow resistance MVGC with free return ow F d V 8/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

4 Dimensions All dimensions in mm, subject to change. MVG MVGC xed only P, R, F, V G 1/4 (BSPP) Connections (ISO 228-1) MVP MVE 1 Sealing ring A 22x27x1.5 DIN 7603 St HAWE Hydraulik SE D 3726 - MVG, MVE, MVP - 02-2016-1.3 9/15

Adjustment No designation Coding R Coding F 1 Adjustment travel 1 Switching travel H Fixed 28 Adjustable 30 Pin head 24 Base plate hole pattern (type MVP) Mounting hole (type MVE) 1 Round off edges Sealing of the ports: O-ring P R 17.12x2.62 NBR 90 Sh 4.47x1.78 NBR 90 Sh 10/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

5 Assembly, operation and maintenance recommendations 5.1 Intended use This valve is exclusively intended for hydraulic applications ( uid engineering). The valve demands high technical safety standards and regulations for uid engineering. The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the speci c complete system must also always be observed. If the product can no longer be operated safely: 1. Remove the product from operation and mark it accordingly It is then not permissible to continue using or operating the product 5.2 Assembly information The product must only be installed in the complete system with standard and compliant connection components (screw ttings, hoses, pipes, etc.). The hydraulic power pack must be shut down correctly prior to dismounting; this applies in particular to power packs with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance. HAWE Hydraulik SE D 3726 - MVG, MVE, MVP - 02-2016-1.3 11/15

5.3 Operating instructions Product configuration and setting the pressure and ow rate The statements and technical parameters in this documentation must be strictly observed. The instructions for the complete technical system must also always be followed. Note Read the documentation carefully before usage. The documentation must be accessible to the operating and maintenance staff at all times. Keep documentation up to date after every addition or update. Caution Risk of injury on overloading components due to incorrect pressure settings! Risk of minor injury. Always monitor the pressure gauge when setting and changing the pressure. Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of the hydraulic component. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Pay attention to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters"). 5.4 Maintenance information This product is largely maintenance-free. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year. 12/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

5.5 Adjusting the valve Note Always monitor the pressure gauge when setting or changing the pressure yourself. The speci ed pressure change values per revolution of the adjusting spindle are only rough indicative values for approximately nding the desired operating point. 1. Remove cap nut (1). 2. Loosen lock nut (3). 3. Unscrew adjusting spindle (2) to approx. h = 18.5 up to max. 19 mm (no noticeable spring preload). 4. If the consumer connected to the system has an end position restricted by a stop (e.g. hydraulic cylinder): Set the directional valve so that the consumer takes up an end position when the pump is switched on (e.g. remains retracted). If the pump has no end position (hydraulic motor): Close the pressure line blind at (A). 5. Prerequisite: The pump must be active. Screw in the adjusting spindle until the pressure gauge displays the desired pressure value (see table below for reference value for pressure change per revolution). 6. Tighten lock nut and cap nut again (don't forget sealing rings!) Type MV.. 13 H MV.. 14 H MV.. 14 M MV.. 14 N Pressure change per rotation, 370 bar, 200 bar, 90 bar, 20 bar HAWE Hydraulik SE D 3726 - MVG, MVE, MVP - 02-2016-1.3 13/15

6 Appendix 6.1 Typical application examples MVG, MVP and MVE As protection for the hydraulic system against overpressure MVG, MVP and MVE As a pre-load valve for generating minimum inlet pressure, e.g. for a control line MVGC For generating counter-pressure at the consumer 1 To the consumer 1 To the consumer 2 Control pressure line 1 To the directional valve 14/15 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE

Further information Additional versions Pressure-limiting valve type MV, SV and DMV: D 7000/1 Pressure-limiting valve (installation kit) type MV: D 7000 E/1 Pressure valve type CMV, CMVZ, CSV and CSVZ: D 7710 MV Pressure-limiting valve, pilot-controlled type DV, DVE and DF: D 4350 D 3726 - MVG, MVE, MVP - 02-2016-1.3 HAWE Hydraulik SE Einsteinring 17 85609 Aschheim/München Postfach 11 55 85605 Aschheim Germany Tel +49 89 379100-1000 Fax +49 89 379100-91000 info@hawe.de www.hawe.com