E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Similar documents
E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

onlinecomponents.com

E3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor

Norrsken Family Booklet

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

General-purpose Relays and Power Relays Sockets

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

SPS-5. Rate Computing Scale. Operation Manual

GasSense NDIR User Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

RTD Temperature sensor TH11

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

Cocoa Patio Pond with Lit Spillway

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

AND OPERATION INSTRUCTIONS

ASDX Series Silicon Pressure Sensors

Digital Vacuum Regulator

Electro-Pneumatic Converter YT-940 SERIES

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

JUMO dtrans p30 Pressure Transmitter

Ambient Weather WS-03 Thermo-Hygrometer

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

SPECIFICATIONS APCEPH1

Accu-Tab Systems 1000 Series by Axiall Corporation

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

FLANGED TWO-PIECE BALL VALVES

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

Instruction Manual for Intrinsically Safe - Reed Switches

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

E2B PROXIMITY SENSORS

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

453 Series Steam Heated Vaporizing Regulator

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

MANUAL KPS Pressure Control Valve

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Research Grade Blood Pressure Transducer User's Manual

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

PPS PORTABLE POWER SUPPLY

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

PRODUCT CATALOGUE WHATEVER YOU RIDE WHATEVER YOU DRIVE...

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Accu-Tab Systems 2000 P Series by Axiall Corporation

! Warning, refer to accompanying documents.

INSTALLATION & MAINTENANCE INSTRUCTIONS

PM105 PRESSURE METER USER S MANUAL

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

IMPACT RING BIT SYSTEM Care & Maintenance Instructions

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

SERIES L4E & L6E LADDER EXTENSIONS

Compact Pressure Switch

O3 3E 1 F Gas Sensor Module

Operation Manual. O2 Quickstick. Oxygen Analyzer

PyroCouple Series Operators Guide

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

FLANGED TWO-PIECE BALL VALVES

Accu-Tab PowerBase 3070AT by Axiall Corporation

Technical Data Sheet MF010-O-LC

Pressure transmitters EMP 2

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

T EK-SUB 4800C 19 mm Submersible Level Transmitter

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

210 Series Transmitter with External Electrochemical Sensor

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction

92831 TEL: (714) FAX:

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Digital Flow Switch. Series PFM7

TH-1800-T TRX-700-CNG Converter

AMS 2710 PCB pressure sensor module with V output

Transcription:

Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space. Be sure to read Safety Precautions on page 3. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information s [Refer to Dimensions on page.] Sensing method Applicable pipe diameters Appearance Output configuration/operation mode Model 8 to mm M Capacitive NPN open-collector output NO to mm EK-LMC M

Ratings and Specifications EK-L Item Model EK-LMC Materials Non-metal Applicable pipes Size Diameter Thickness * Stable detection will not be possible in the following cases. Confirm detection capability with the installed before actual application.. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive sensor.. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe are too thick 3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall Engineering Data (Reference Value) 8 to mm to mm mm max..5 mm max. Detectable object Liquid * Repeat accuracy ±. mm max. Differential travel (Reference value, varies with pipe size and liquid.). to 5 mm.3 to 3 mm Power supply voltage (operating voltage range) to VDC (.8 to 3 VDC), ripple (p-p): % max. Current consumption ma max. Control output Load current ma max. Residual voltage V max. (Load current: ma, Cable length: m) Sensing liquid position Indented mark position (For details, refer to Technical Guide (Operational version).) Indicators Ambient temperature range Operating: to 55 C (with no icing or condensation), Storage: to 5 C (with no icing or condensation) Ambient humidity range Operating/Storage: 5% to 85% (with no condensation) ± mm of detection level at 3 C in the temperature range of to 55 C (with pure water or % saline Temperature influence solution) (± mm for with pure water and a pipe diameter of 8 mm) Voltage influence ±.5 mm of detection level at the rated voltage in rated voltage ±% range Insulation resistance 5 MΩ min. (at 5 VDC) between current-carrying parts and case Dielectric strength 5 VAC, 5/ Hz for min between current-carrying parts and case Vibration resistance Destruction: to 55 Hz,.5-mm double amplitude for hours each in X, Y, and Z directions Shock resistance Destruction: 5 m/s 3 times each in X, Y, and Z directions Degree of protection IP (IEC) Connection method Pre-wired Models (Standard cable length: m) Weight (packed state) Approx. 7 g Materials Case, Cover Heat-resistant ABS Cable clamp NBR Accessories Two bands, Four slip-proof tubes, Instruction manual Influence of Temperature and Sensing Liquid Level EK-LMC Change in sensing liquid level (mm) - diameter:, Liquid: Pure water diameter:, Liquid: Saline solution diameter: 8, Liquid: Pure water diameter: 8, Liquid: Saline solution 3 5 Temperature ( C) Change in sensing liquid level (mm) diameter:, Liquid: Pure water diameter:, Liquid: Saline solution diameter:, Liquid: Pure water diameter:, Liquid: Saline solution 3 5 Temperature ( C)

I/O Circuit Diagrams EK-L Operation mode Model Timing chart Output circuit Brown +V NO EK-LMC Liquid level Load (between brown and black leads) Present None Operate Reset ON OFF Main circuit Black * Blue Load V Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. Design Influence of Surrounding Objects When mounting the, maintain at least the distances in the following diagrams from surrounding metal objects or other conductors to prevent the from being affected by objects other than the sensing object. Mutual Interference * Load current: ma max. Distance Model D * E F 5 EK-LMC 3 * Also, always adjust the bottom first because adjusting the bottom may affect the detection level of the top. Mounting Mounting Mount the securely to the pipe using the enclosed two bands and four slip-proof tubes (two tubes used for each band) as shown in the following diagram. When mounting the, be sure the entire is tight against the pipe along the sensing surface. A Face-to-face On One Side Influence of Surrounding Objects B On Both Sides Distance A B C Model 5 5 5 EK-LMC Mutual Interference When installing s in series, in parallel, or face-to-face, ensure that the minimum distances given in the following table are maintained. D C Liquid level Set position (indented mark) Bands Side View Slip-proof tubes Bands Slip-proof tubes Front View Top View Adjustment For information on the sensitivity adjustment, refer to Technical Guide for Operation for information for Proximity. In Series E In Parallel F Face-to-face 3

EK-L Wiring Power Supply If the load and are connected to different power supplies, always turn ON the power first. Switching noise can cause operating mistakes if a commercial switching regulator is used. When using a switching regulator, always ground the frame ground terminal and the ground terminal. Operating Environment Ambient Atmosphere Although the is water resistance, it is a capacitive sensor and should not be used where it will come into direct contact with liquids, such as water or cutting oil. The life of the will be shorten by rapid changes in temperature even within the ambient operating temperature range. Do not use the in locations subject to rapid temperature changes. Miscellaneous Drift will occur when the power supply is turned ON. If the specific inductive capacity of the sensing liquid is low, the detection level may increase by to 3 mm during the minutes required from the time the power supply is turned ON until operation stabilizes. Dimensions Tolerance class IT applies to dimensions in this data sheet unless otherwise specified. 5 R.5 R7.5 Mounting holes.5 3 33 5.5 Sensing surface.5 *.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m 3.5 EK-LMC 5 R3 R7.5 33 Mounting holes.5.5 3 3 3 Sensing surface 3.5 *.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m.5

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 5. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 5 All Right Reserved.