LPG LEVEL GAUGE /INDICATOR manual

Similar documents
Job Sheet 1. Geothermal Energy

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

Automatic Twin Greasing System

unconventional-airsoft.com

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Reverse Osmosis System Installation Guide and Operation Manual.

UNIVERSITY OF WATERLOO

ProMaster Troubleshooting Guide

Copyright Velocomp LLP 2006

Operating Manual Body fat balance

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

MAINTENANCE AND OPERATING MANUAL

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

MAGNETIC CYCLING TRAINER SF-B0419 USER MANUAL

MoveRoll Conveyor Operating and Maintenance Manual

Wire ropes condition monitoring: conception and embodiment

POWER LIFT LOW PRESSURE LIFTING BAGS. Instructions for use

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

MP15 Jockey Pump Controller

A little technical and safety...

Troubleshooting Guide Aquarius

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Process Control Loops

Four common PRESSURE CALIBRATION PAIN POINTS

BUBBLER CONTROL SYSTEM

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

The Discussion of this exercise covers the following points:

Installation and commissioning instructions 255 series and 256 series

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

User Manual. Low Shear Viscometer LS 300. prorheo GmbH Bahnhofstr. 40/ Althengstett Tel

Parts Manual. Frusheez Machines

SWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Aquavar SOLO 2 Frequently Asked Questions

Part IV: Troubleshooting

Air Ball! Evaluation copy

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

TESTING AT VERY LOW FLOWRATE

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Code Basic module and level control complete with optionals code

Quick Installation Guide Doc nr.: C Date:

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

ECL Comfort 110, application 131 (valid as of software version 2.00)

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

Note: You will need a full tank of CO2 for connection and leak testing! Kit Number

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Declining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website:

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Pneumatics for Newbies Designing a Pneumatic Solution

Armfield Distillation Column Operation Guidelines

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

Operating Instructions Part No

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Easy Nest Kits. Installation Suggestions

NTF-230 OPERATION MANUAL

Discharge Relief Valve Operation & Maint.

User Manual for the Mars Calibration Bench

OPERATION OF LIQUID PARTICLE COUNTER. GP-B P0045 Rev -

Cover Page for Lab Report Group Portion. Pump Performance

Further technical information is available on

ACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION

P7810A-D Pressuretrol Controller

G96 Series BASOTROL Dual Operator Valve

9A5N Solid State CW Paddle

NIV EAU MATIC ST User Manual Made in Canada

Elevator Concepts ltd. by Wurtec Krause Riverview, MI Fax:

The Discussion of this exercise covers the following points:

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

G92 Series BASOTROL Automatic Pilot Gas Valve

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Exercise 3-2. Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Two-wire control

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

NEULOG OXYGEN LOGGER SENSOR GUIDE

MODEL NUMBER: P PORTABLE COMPRESSOR

Experiment C-6 Gas Solubility

Mapping a Magnetic Field. Evaluation copy. Figure 1: Detecting the magnetic field around a bar magnet

Installation Instructions Air Compressor Part # 2780, 2781

Additel761 Series Firmware Updates

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

High Pressure Chem-SCAN Operating Manual

Mass Spec will not pump down

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Document How to Set Single Stage Press Pressures

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

Sensoric 4-20 ma Transmitter Board Operation Manual

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10

KIV-SACS Safe automatic calibration system:

P7810C PressureTrol Controller

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

Chapter 10: Bidirectional Flow Controls

Read this material before using this product. Failure to do so can result in serious injury.

How many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.

SPIROVENT VACUUM DEGASSERS

Transcription:

LPG LEVEL GAUGE /INDICATOR manual All Rights Reserved. Copying the text, pictures, nameplates before prior permission is forbidden. FHT Production: FHT Export-Import, 05-300 Minsk Mazowiecki, Szczecinska 16G Street. FHT Foreign Trade Office info: +48 609-555-987, fax: +48 25-759-42-51. Enquiries at www.versuslpg.com, export@versuslpg.com.

The installation of VERSUS Gauge should be done according to the following scheme: 1) In most cases optimal position of the Gauge towards Multivalve is as on the picture: NOTE: THE MOST IMPORTANT IN VERSUS GAUGE CALLIBRATION IS TO SELECT PROPER POSITION OF THE GAUGE TOWARDS THE MULTIVALVE AND TO FIT THE INDICATOR SOLIDLY. The back side of the indicator have to be the closest to the MV (not far than 0,5 mm). If it is fitted in other way the indicator could not show every level of LPG inside the tank.

In most cases optimal position of the gauge is in the range between (pictures below): Not suggested positions (pictures below): INCORRECT! If the gauge is incorrectly fitted to the Multivalve the indication of LPG inside the tank could be different tan real level or proportionally different. www.versuslpg.com

There are 5 diodes on the indicator. One of them shines on red (low level of LPG in the tank). The rest of them indicate the level of LPG in the tank (green color). To set up proper indication of LPG level inside the tank you it is recommended: a) firstly to fill the tank with about ¼ real capacity. Real capacity means that if nominal capacity is 50 liters the tank can be filled only with 40 liters of LPG (20% of air safety area inside the tank). b) So in case of 50 liters capacity tank you have to fill the tank with 10 (1/4 of 40 liters = 10 liters) liters of LPG. Than; c) It is essential to set up proper indication on the gauge. The indication on that is as follows: Note: ONLY ONE OF THE DIODES SHINES. d) If the tank was filled with ¼ real capacity (in our case 50 ltr nominal capacity = 40 ltr real capacity. ¼ = 10 ltr) first step is to turn the indicator on the gauge to set up initially proper indication. There is no rule if you are to turn the indicator right or left. You have to turn the indicator till the moment the second diode starts to shine (first green diode from the diagram above). e) Next stem is to screw the indicator to the Multivalve (two screws from both sides of the indicator). www.versuslpg.com

f) If there is 10 ltr of LPG inside of 50 ltr nominal capacity the tank and the indicator was properly fitted to Multivalve on VERSUS change over switch inside driver cabin you can see red diode shining (not blinking, not any green diode shining). g) If there is any difference in the indication between VERSUS change over switch and VERSUS LPG Gauge you can set up proper indication in the software (described in further part of this manual). BEFORE THAT PLEASE MAKE SURE THE INDICATOR IS PROPERLY CONNECTED TO THE MULTIVAVLE (POSITION, SOLIDNESS). h) Than what should be done is to fill up the tank in full. In our case (50 ltr nominal capacity LPG tank it should be 10 ltr + 30 ltr = total 40 ltr). If LPG Tank is full the indicator fitted to Multivalve should show Full tank diode shining. On VERSUS change over switch you could see all of the diodes shining. If there is any difference in the indication you should set up adequate parameter in VERSUS software in LPG level sensor bookmark: NOTE: the changes should be performed when the car works on LPG. i) VERSUS software automatically set up VERSUS/AEB1050 sensor. Please check if you selected right sensor (should be as on the picture above in case of VERSUS LPG gauge). Than if the indication is not real you have the possibility to change it. In case of Full tank you should operate the value responsible for 1/1 (picture below).

There is no rule if you should decrease the value of to increase. In our case initial value of that is 241. If the diode 1/1 does not shine but the tank is full you have to increase or decrease the parameter in the window responsible for that indication till the moment the indication is proper (all diodes of VERSUS change over switch shines). NOTE: AFTER ANY CHANGE IN THE VALUE IN THE WINDOWS RESPONSIBLE FOR INDICATION YOU HAVE TO PRESS WRITE TO DEVICE. j) You can set up the value for ½, ¾ in the same way on the basis of the same rules. Note: if you intend to set up the parameter responsible for ¾th indication there should be ¾ LPG inside the tank. There are some reasons for improper indication: 1) the construction of Multivalve itself. Sometimes in case of 50 ltr nominal capacity the tank can be filled with 45 ltr (sometimes 37 ltr etc.). Also how many liters of LPG can be put inside the tank depends on LPG filling station pump pressure (some differences between different countries standards/allowed pressure). 2) The indication is based on some magnetic rules. Multivalve (E67R 01 ) has a coil. Coil generates electromagnetic field that can disturb proper work of any LPG gauge. EXAMINIG PROPER WORK OF THE INDICATOR. Therefore sometimes it is essential to set up proper indication in the software. To examine if the gauge works correct (if it is not broken) you should: 1) connect wiring to the indicator (+, - is to be connected) 2) to use Multivalve (recommended) or piece of magnet and to put it close to back side of the indicator. 3) Than to move the arm of Multivalve/magnet slowly. 4) If the gauge works correct EVERY DIODE SEPARATELY shines. All Rights Reserved. Copying the text, pictures, nameplates before prior permission is forbidden. FHT Production: FHT Export-Import, 05-300 Minsk Mazowiecki, Szczecinska 16G Street. FHT Foreign Trade Office info: +48 25 759-42-61, fax: +48 25-759-42-51. Inquiries at www.versuslpg.com, info@versuslpg.com.