Differential pressure switch MP 54, MP 55 and MP 55A

Similar documents
Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Pressure switch KP-E. Data sheet

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure switch and Thermostat CAS

Pressure controls, differential pressure controls type RT

Pressure switch and Thermostat Type KPS

Pressure switches for air and water CS

Pressure switch and Thermostat KPS

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switches and thermostats, type KPS

Evaporator pressure regulator Type KVP

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

Evaporator pressure regulator Type KVP

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure control, differental pressure control and thermostat Type RT

Condensing pressure regulator, type KVR Receiver pressure regulator, type NRD

Pressure transmitters EMP 2

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Pressure switch RT. Data sheet

TeSys protection components

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Solenoid valve type EVR for Hydrocarbons

Pressure switch Type BCP

Shut-off ball valve Type GBC

Float valves Types SV 1 and SV 3

Types and approvals. Page 1/6. Data Sheet

Position switches FP series

Pressure switch SANHUA PS01/50/15 SERIES. ideas worldwide STANDARD

Shut-off ball valve Type GBC

Electromechanical pressure switches

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Float valves Types SV 4, SV 5 and SV 6

Prewired position switches FA series

Electromechanical pressure switches

) for different types of systems Test of contact function The correct pressure control for your system

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

Pilot valves for pilot operated servo valves

2-step solenoid valve Type ICLX

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Meta-MEC Manual Motor Starters

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2-step solenoid valve Type ICLX

Liquid level regulating valves Types PMFL / PMFH and SV

SITRANS P measuring instruments for pressure

JUMO dtrans p30 Pressure Transmitter

CALEFFI. Ball zone valves. series /03 GB

Gas density monitor With integrated transmitter Model GDM-100-TI

Dual position solenoid valve Type ICSH 25-80

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

2-port seat valves PN25 with externally threaded connections

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Operating Instructions

ATH-EXx. B Operating Instructions

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Prewired position switches FA series

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

ATH-EXx. B Operating Instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Shut-off ball valve Type GBC

Operating Instructions

High-performance submersible pressure transmitter For level measurement Model LH-10

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

EX-RECESSED CEILING LIGHT FITTINGS

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Technical Data. Dimensions

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)

Monitoring device NTS 30

[Instruments for vacuum measurement, checking and adjustment] 3

DSL, DSH: Specially designed pressure limiter

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

Safety relief valves Type BSV-8

Solenoid Valves, one - or two step, on/off ICLX

XML Electromechanical Pressure Switches

Safety relief valves Type SFA 15 and SFA 15-50

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Compact pressure switches for gas and air

Pressure regulating valves Types OFV, OFV-SS

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Tightness controls TC 1 3 and TC 4

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Manual Power relay SR853

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Valve Proving System VDK 200 A S02

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

Valve Proving System VDK 200 A S06*

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Transcription:

Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating oil pressure. If the oil pressure fails, the oil differential pressure switch stops the compressor after a certain time period. MP 54 and MP 55 are used in refrigerating systems using HCFC and non-flammable HFC refrigerants. MP 55A is used in refrigerating systems with R717. MP 55A can also be used in systems with HCFC and non-flammable HFC refrigerants. MP 54 has a fixed differential pressure setting. It also incorporates a thermal time relay with a fixed release time setting. MP 55 and MP 55A have adjustable differential pressure and are available both with and without thermal time relay. Features Wide regulating range Can be used for deep freeze, refrigeration and air conditioning plant Can be used for HCFC and non-flammable HFC refrigerants Electrical connection at the front of the unit Suitable for both alternating and direct current (AC and DC) Screwed cable entry for cables from 6 14 mm diameter Small contact differential Approvals CE mark according to LVD 2006/95/EC EN 60947-1, EN 60947-4-1, EN 60947-5-1 China Compulsory Certificate, CCC Versions having UL and CSA approvals can be supplied to special order Ship approvals Germanischer Lloyd, GL Registro Italiano Navale, RINA (MP55) DKRCC.PD.CG0.B9.02 520H11529 1

Materials in contact with the medium Unit type MP 54 MP 55 MP 55A Material Stainless steel 19/11, no. 1.4306 to EN 10088 Cold forming steel, no. 1.0338, EN 10139 Free cutting steel, no. 1.0718, EN 10277 Stainless steel 19/11, no. 1.4306 to EN 10088 Cold forming steel, no. 1.0338, EN 10139 Free cutting steel, no. 1.0401, EN 10277-2 Technical data Control voltage Permissible voltage variation -15 10% Max. working pressure Max. test pressure Ambient temperature The time relay is temperature-compensated in the range 230 V or 115 V AC or DC PS/MWP = 17 bar P e = 22 bar -40 60 C Screwed cable entry P g 13.5 Cable diameter 6 14 mm Max. bellows temperature 100 C Switch differential max. p 0.2 Enclosure IP20 to EN 60529 / IEC 60529 Contact loads MP with time relay (contacts M-S) MP without time relay AC15 = 2 A, 250 V DC13 = 0.2 A, 250 V AC15 = 0.1 A, 250 V DC13 = 12 W, 125 V solid / stranded 0.2 1.5 mm 2 Wire dimensions flexible, without ferrules 0.2 1.5 mm 2 flexible, with ferrules 0.2 1 mm 2 Tightening torque Rated impulse voltage max. 1.2 Nm 4 kv Pollution degree 3 Short circuit protection, fuse Insulation 2 A 250 V Terminology Differential range The pressure difference between LP and OIL connections within which the switch can be set to operate. Scale reading The differential between the oil pump pressure and the pressure in the crankcase that exists at the moment the contact system cuts in current to the time relay on falling oil pressure. Operating range The pressure range on the LP connection within which the switch can operate. Contact differential The pressure rise above the set differential pressure (scale reading) necessary to cut off current to the time relay. Release time The period for which the differential pressure switch allows the compressor to run with too low an oil pressure during start-up and operation. 2 520H11529 DKRCC.PD.CG0.B9.02

Ordering For R22, R134a, R404A, R407A, R407C, R407F, R422B, R422D, R448A, R449A, R450A, R452A, R507A, R513A For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Type MP 54 MP 55 Differential p Operation range, LP side Relay release time [s] 1/4 in Flare Code no. Connection 1 m cap.tube 1/4 in ODF solder M12 x 1.5 with 6 mm cutting ring 0.65-1 12 0 2 ) 060B029766 0.65-1 12 45 060B016666 0.9-1 12 60 060B016766 0.65-1 12 90 060B016866 0.65-1 12 120 060B016966 0.3 4.5-1 12 45 060B017066 060B013366 0.3 4.5-1 12 60 060B017166 0.3 4.5-1 12 60 060B017866 1 ) 0.3 4.5-1 12 90 060B017266 0.3 4.5-1 12 120 060B017366 0.3 4.5-1 12 0 2 ) 060B029966 For R22, R134a, R404A, R407A, R407C, R407F, R422B, R422D, R448A, R449A, R450A, R452A, R507A, R513A, R717*) For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Type MP 55A Differential p Operation range, LP side Relay release time [s] Code no. Connection G 3/8 A supplied with ø6.5 / ø10 mm weld nipple M12 1.5 with 6 mm cutting ring 0.3 4.5-1 12 45 060B017466 060B018266 0.3 4.5-1 12 60 060B017566 060B018366 0.3 4.5-1 12 60 060B017966 1 ) 0.3 4.5-1 12 90 060B017666 060B018466 0.3 4.5-1 12 120 060B017766 060B018566 0.3 4.5-1 12 0 2 ) 060B029866 2 ) 060B029666 1 ) With glow lamp that remains on during normal operation. Note: If the operational light goes out, the compressor should not run longer than the release time. *) only for MP 55A 2 ) MP without time relay. Versions without time relay are for applications where an external time relay is required perhaps with a different release time than the one specified. Design 3 2 4 The operation of the pressure switch relies only on the differential pressure, i.e. the difference in pressure between the two counteracting bellows, whereas it is independent of the absolute pressure acting on both bellows. The MP 55 and 55A can be set for different differential pressures by the setting disc (3). The set differential pressure can be read from the internal scale. The MP 54 has a fixed differential and has no pressure setting disc. The factory-set differential pressure is stamped on the front plate of the switch. 1. Connection to pressure side of lubrication system, OIL 2. Connection to suction s ide of refrigeration plant, LP 3. Setting disk (MP 55 and MP 55A) 4. Reset button 5. Test device 5 MP 55 1 DKRCC.PD.CG0.B9.02 520H11529 3

Function If there is no oil pressure on starting, or if the oil pressure falls below the set pressure during operation, the compressor will stop after the release time has elapsed. The electrical circuit is divided into two completely separate circuits: a safety circuit and an operational circuit. Electrical diagram The timer (e) in the safety circuit is activated when the effective lubricating oil pressure, the oil differential pressure (the difference between the oil pump pressure and suction pressure), is lower than the set value. The timer is deactivated when the oil differential pressure is more than the set value plus the contact differential. Danfoss 60B55.13 OIL TEST RESET The two diagrams below explain the terms "oil differential pressure" and "contact differential". Both have to be considered when using oil differential pressure switches. The first diagram shows the function of the differential switch during start; the second shows the function of the switch during operation. During start Danfoss 60B59.13 Switch differential Control differential On start-up [s] 4 520H11529 DKRCC.PD.CG0.B9.02 Pos. A: Normal start-up. The lubricating oil pressure is built up during start to the set/fixed differential plus the contact differential, before the timer cuts out (in this example, after 45 seconds). At point A contacts T1-T2 open and timer (e) is stopped, i.e. normal lubricating oil conditions for the compressor have been established. Pos. B: The lubricating oil pressure does not reach the set/fixed differential plus the contact differential before the timer period elapses. At point B the timer cuts out operational circuit L-M and the compressor stops. If a signal source is connected to terminal S, it will be activated. Restart can only be performed after about 2 minutes by activation of the reset button, provided the cause of the fault has been determined.

Function (continued) During operation [s] Pos. C: The lubricating oil pressure falls during operation to a value lower than the set/fixed differential. At point C, safety circuit T1-T2 cuts in and the timer is activated. Pos. D: The lubricating oil pressure reaches the set/fixed differential plus the contact differential before the timer period elapses. At point D, safety circuit T1-T2 cuts out and the timer is stopped, i.e. normal lubricating oil conditions for the compressor have been established. Pos. E: The lubricating oil pressure falls to a value lower than the set/fixed differential during operation. At point E, safety circuit T1-T2 cuts in and the timer is activated. Pos. F: The lubricating oil pressure remains lower than the set/fixed differential. At point F the timer cuts out operational circuit L-M and the compressor stops. If a signal source is connected to terminal S, it will be activated. Restart can only be performed after about 2 minutes by activation of the reset button, provided the cause of the fault has been determined. After start-up It is important that a function check should be made to ensure that the differential pressure control is operating as it should. This check can be made by pressing the test device (inside the unit on the left hand side). When the test device is pressed down and held in this position, the compressor motor should stop after the release time determined by the time relay has elapsed. DKRCC.PD.CG0.B9.02 520H11529 5

Dimensions [mm] and weight [kg] MP 54, MP 55, MP 55A Danfoss 60B109.12 Net weight: approx. 0.8 kg DKRCC.PD.CG0.B9.02 520H11529 6