Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch

Similar documents
Rosemount 2130 Level Switch

Rosemount 2120 Full-featured

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Rosemount 2120 Vibrating Fork Liquid Level Switch

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Level transmitter LT 100

Guided Wave Radar in Solid Level Applications

Liquid level instruments BM 24 /BM 51

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

9700 Transmitter Submersible hydrostatic level transmitter

How to specify a product. Process Sensors and Mechanical Instruments

Specify the Right Remote Diaphragm Seal Solution for Vacuum Applications

DREXELBROOK A Leader In Level Measurement Solutions

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch. Quick Start Guide , Rev BA August 2012

Product information Vibrating

Mobrey MLT100 Displacer Level Transmitter

780S Ultra High Purity Series

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers

BUBBLER CONTROL SYSTEM

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Point Level Measurement. Switching Technology for Liquid and Solid Level Measurement

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Micro Motion 7812 Fiscal Gas Density Meter

Electronic Turbine Meter TERZ 94

Liquid level switch BM 34

SITRANS P measuring instruments for pressure

RCD - Ultra-Rugged Differential Pressure Flowmeter

Ultrasonic level transmitter and indicator

Torque Tube TB300 Digital Transmitters

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Magnetic level switch type MR783 Instruction Manual

Ultra High Purity Model 780S

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Differential pressure

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

RMG Meßtechnik GmbH. Publication No E

High-performance submersible pressure transmitter For level measurement Model LH-10

Features. Description

BUBBLER CONTROL SYSTEM

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Monitoring device NTS 30

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Pressure Measurement Single-range transmitters for general applications

Point level switches for safety systems

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

JUMO dtrans p30 Pressure Transmitter

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

GA24 Technical Datasheet

analytical bulk flow distance FLOW level pressure temperature industrial communication

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

For Multi-Parameter Meters see mvx

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Electro Controls. Level WattsIndustries.co.uk

Technical Data. Dimensions

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Differential pressure switch / Lube oil protection control MP 54 and MP 55

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Instrumentation & Data Acquisition Systems

Technical Data. General specifications. Rated operating distance s n 5 mm

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

process measurement solutions The level solutions catalogue

VA40 - VA45 Technical Datasheet

Rosemount 2130 Level Switch

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Pressure transmitters EMP 2

Electro-Pneumatic Converter YT-940 SERIES

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

sitrans p Operating Instructions (de/en) Edition 03/2004

Technical Data. Dimensions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Technical Data. Dimensions

[Instruments for vacuum measurement, checking and adjustment] 3

Transcription:

Technical Note ommunicate Rosemount 2130 Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch The Rosemount 2130 Vibrating Fork Level Switch, based on vibrating short fork technology, is designed for use in extreme temperatures of 94 to 500 F ( 70 to 260 ) and suitable for virtually all liquid applications. Features include a complete range of process connections, wide choice of housings and wetted parts materials, four different switching functions, extended fork lengths, and hazardous area approvals. This makes the Rosemount 2130 an ideal choice for a wide variety of challenging applications in the chemical, power generation, and oil and gas industries. MEASUREMENT PRIIPLE The Rosemount 2130 is a liquid point level switch designed using the principle of a tuning fork. A piezo-electric crystal oscillates the forks at their natural frequency. hanges to this frequency are continuously monitored. When the 2130 is used as a low alarm, the liquid in the vessel drains down past the fork causing a change of natural frequency that is detected by the electronics and switches the output state. When the 2130 is used as a high alarm, the liquid rises in the vessel, making contact with the fork causing the output to switch. Short Fork Technology The natural frequency (~1400Hz) of the fork avoids interference from plant vibration that may cause false switching. This allows for minimum intrusion into the vessel or pipe through the use of a short fork. Using Short Fork Technology, the Rosemount 2130 can be used in almost all liquid applications. Extensive research has maximized the operational effectiveness of the fork design, making it suitable for almost all liquids including coating liquids (avoid bridging of forks), aerated liquids, and slurries. SPEIAL FEATURES Mode Switch and Adjustable Time Delay A mode switch allows the 2130 to be set to switch from wet-to-dry (typically for low level alarm) or from dry-to-wet (typically for high level alarm). There is also a user-selectable time delay of 0.3, 1, 3, 10, or 30 seconds. Increasing the time delay in turbulent or splashing applications virtually eliminates the risk of false switching. Heartbeat LED The 2130 has a heartbeat LED that indicates status. The LED flashes when the 2130 output is off and is constantly lit when 'on'. The LED constantly indicates that state of the 2130. Magnetic Test Point A magnetic test-point is located on the side of the housing, allowing for a functional test of the 2130 and the system connected to it. Holding a magnet to the test-point causes the output to change states. Instrument Health Monitor and ontinuous Self-heck The 2130 continuously performs instrument health diagnostics to self-check the condition of the fork and sensor. These diagnostics can detect damage to the forks including corrosion, internal or external damage to the forks, and breakages to the internal wiring. Any of these conditions will trigger the 'heartbeat' LED to pulse intermittently, followed by safe handling of the electrical load. Electrical Hookup The terminal blocks extend above the housing and give easy terminal access. The polarity insensitivity on Direct Load and Relay electronics, and short-circuit protection on Direct Load and PNP/PL electronics make electrical hook-up safe and easy. Fork Design The fast drip fork design draws liquid away from the fork tips, together with a short switching delay allows the 2130 to react quickly and with greater sensitivity to density variations.

Rosemount 2130 Technical Note ommunicate Rosemount 2130 Application Examples High integrity Manual test facility Overfill Protection Spillage caused by overfilling can be hazardous to people and the environment, resulting in lost product and potentially high clean up costs. High temperature High pressure High and Low Level Alarm Maximum and minimum level detection in tanks containing different types of liquids are ideal applications. The Rosemount 2130 is robust and operates continuously across the temperature range of 94 to 500 F ( 70 to 260 ) and operating pressures of up to 1450 psig (100 barg), making it perfect for use as a high or low level alarm. It is common practice to have an independent high level alarm switch as a backup to an installed level device in case of primary failure. Time delay switching option Resistance to false switching Pump ontrol (Limit Detection) Batch processing tanks often contain stirrers and agitators to ensure mixing and product fluidity. The standard user selectable time delay, from 0.3 to 30 seconds, virtually eliminates the risk of false switching due from splashing. Small forks Low cost Extreme temperature range Thermal tube Pump Protection or Empty Pipe Detection With the fork projecting only 2 inches (50 mm) (dependant on connection type), the 2130 can be installed in small diameter pipes. Short forks mean minimum intrusion on the wetside and allow for simple, low cost installation at any angle into pipes or vessels. By selecting the option of direct load switching electronics, the 2130 is ideal for reliable pump control and can be used to protect against pumps running dry. Extreme Temperature Applications The 2130 is designed for extreme temperatures and is suitable for continuous operation within the temperature range of 94 to 500 F ( 70 to 260 ). Add wireless switches to existing or new plant Acts as a wireless repeater Wireless Applications The advent of wireless communications allows process plant managers to save up to 90% on installation cost compared to wired technologies. More data can be collected at central locations than ever before. The 2130 can be used with a Rosemount 702 Wireless Transmitter to enable these benefits for your applications. Hygienic surface finish Extended fork Hygienic Applications With the highly polished forks option providing a surface finish (Ra) better than 0.4 µm, the 2130 meets the most stringent hygienic requirements used in food and beverage, and pharmaceutical applications. Manufactured in stainless steel, the 2130 is robust enough to easily withstand steam cleaning (IP) routines. 2

Technical Note ommunicate Rosemount 2130 Selecting a Rosemount 2130 Vibrating Liquid Level Switch The 2130 consists of a housing, thermal tube, process connection, and forks. The process connection and forks are the only wetted parts. FIGURE 1. 2130 Features Direct Load, Relay (DPO), PL/PNP, and NAMUR Electronics NEMA Type 4X (IP66/67) Housings in Aluminum or 316/316L SST ATEX, FM, SA, IEEx, NEPSI Explosion-proof / Flameproof and Intrinsically Safe Short Fork Length with Extensions up to 118 in. (3 m) Switch Housing Magnetic Test Point Two able / onduit Entries Thermal Tube Threaded, Flanged, or Hygienic onnections Fast Drip Design Wetted material in 316/316L SST (1.4401/1.4404), or Alloy (UNS N10002) and Alloy -276 (UNS N10276) The switch housing is available in aluminum or SST, with two cable/conduit entries (M20 or 3 /4-in. NPT). It can be ordered with Explosion-proof / Flameproof or Intrinsically Safe approvals. See Product Data Sheet 00813-0100-4130 for approvals. Electronics Standard two-core cable can be used with any power supply from 20 to 264V ac (50/60 Hz) or 20 to 60V dc to connect the Rosemount 2130 in series with a load to achieve direct load switching (page 4). The output acts as a simple SPST switch that changes state with liquid presence. Alternatively, the switching function of the DPO dual relay electronics output can be used (page 4). The 2130 has an electronics option that can be interfaced directly to a Programmable Logic ontroller (PL) using the PNP transistor output model (page 4). The 2130 is also available with a NAMUR switching output (page 4). TE: See Product Data Sheet (00813-0100-4130) for available accessories and ordering information. Process onnection and Fork Fork Length Short fork, for minimum intrusion installation (minimum length is 2 in. [50 mm]). Fork extensions are available up to 118 in. (3 m). Threaded onnection Threads: R 3 /4-in. and 1-in. (BSPT); G 3 /4-in. and 1-in. (BSPP); 3 /4-in. and 1-in. NPT Material: 316/316L SST (1.4401/1.4404), or Alloy and Alloy -276 Accessories: A stainless steel adjustable clamp gland is available for use with the extended length 2130 (1-in. models only). This is a threaded 1 1 /2-in. BSPP to connect to the vessel, and allows the 1-in. extended length 2130 to be raised or lowered, as desired, and then clamped into position. Flanged onnections Flange: ASME B16.5 (1-in. or larger), or EN 1092-1(DN25 or larger) Material: 316/316L SST (1.4401/1.4404), or Alloy and Alloy -276 Hygienic onnections Fittings: 1 1 /2-in. (38 mm) or 2-in. (51 mm) Tri-lamp, or 1-in. BSPP (G) O-ring seal Material: 316/316L SST (1.4401/1.4404) Options: Hand polished wetside to a finish better than 0.4 µm meets the most stringent hygienic requirements. Accessories: A mounting kit comprising vessel fitting, Nitrile seal and clamp ring is available for use with the 2-in. (51-mm) Tri-lamp version of the 2130. A fitting boss with Fluorocarbon (FPM/FKM) O-ring is available for use with the O-ring seal version of the 2130. FIGURE 2. Tri-lamp Fitting 1.5-in. (38-mm) or 2-in. (51-mm) Tri-lamp 3

Rosemount 2130 Technical Note ommunicate Output Selection Do you require I.S. certification? Yes hoose the NAMUR cassette (Electronics ode N) Number of Wires: 2 No Note: I.S. cassettes can only be replaced with I.S. cassettes. Non-I.S. cassette types can be interchanged with other non-i.s. cassette types, but the new label must be fitted and the original part number transferred to the new label Do you require voltage free dry contacts (relay)? Yes hoose the Relay cassette (Electronics ode D) Number of Wires: 6 + Ground No Do you require 2-wire switching? Yes hoose the Direct Load cassette (Electronics ode L) Number of Wires: 2 Wires + Ground No Are you interfacing directly into a PL or DS? Yes hoose the PNP/PL cassette (Electronics ode P) Number of Wires: 3 Wires + Ground 4

Technical Note ommunicate Rosemount 2130 Isolating Amplifier To NAMUR (IE60947-5-6, EN50227) The 2130 Blue assette NAMUR Load Ion = 2.2 to 2.5 ma Ioff = 0.8 to 1.0 ma Non-Hazardous Area Hazardous Area The 2130 Green assette DPO Dual Relay Relay SPDT Load Load The 2130 Red assette Direct Load Switching Relay SPDT Load PNP/PL The 2130 Yellow assette PNP/PL Input 5

Rosemount 2130 Technical Note ommunicate Application and Installation Best Practices Application onsiderations: Ensure the process is operating within the instrument temperature and pressure ranges Ensure the liquid viscosity is within the recommended viscosity range heck that the liquid density is higher than 37.5 lb/ft 3 (600 kg/m 3 ), or above 31.2 lb/ft 3 (500 kg/m 3 ) when ordered with the Low Density Range option heck the risk of build-up on the forks. Drying and coating products may create excessive build-up Ensure there is no risk of bridging the forks Examples of products that can create bridging of forks are dense paper slurries and bitumen heck the solids content in the liquid As a guideline, 0.2 in. (5 mm) is the maximum solid particle diameter in the liquid When dealing with particles larger than 0.2 in. (5 mm), consult the factory Problems may occur if the product coats and dries, causing caking In almost all cases, the 2130 is insensitive (does not see) foams In rare cases, some very dense foams may be seen as liquid. An example of this is ice-cream and orange juice manufacturing Recommended Installation: Always install in the on state: For a high level, use the Dry on setting For a low level, use the Wet on setting Ensure the system is tested by using the local magnetic test-point during commissioning Ensure there is sufficient room for mounting and for electrical connections Avoid installing the 2130 near to liquid entering the tank at the fill point Avoid heavy splashing on the forks Increasing the time delay reduces accidental switching caused by splashing Ensure the forks do not come into contact with the tank wall, any internal fittings, or obstructions Ensure there is sufficient distance between build-up on the tank wall and the fork (Figure 3) Extra consideration is needed if the plant vibration is close to the 1400 Hz operating frequency of the 2130 Supporting the fork avoids long fork length vibration (Figure 4) FIGURE 4. Supports For Long Fork Lengths FIGURE 3. Avoid Build-up On A Tank Wall 3.3 ft. (1 m) Max. 3.3 ft. (1 m) 3.3 ft (1 m) 3.3 ft. (1 m) Max. TE: See Product Data Sheet 00813-0100-4130 for ordering information, specifications, approvals, and dimension drawings. 3.3 ft. (1 m) 3.3 ft. (1 m) 6

Technical Note ommunicate Rosemount 2130 7

Rosemount 2130 Technical Note ommunicate The Emerson logo is a trademark and service mark of Emerson Electric o. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. Standard Terms and onditions of Sale can be found at \terms_of_sale 2010 Rosemount, Inc. All rights reserved. Emerson Process Management Rosemount Inc. 8200 Market Boulevard hanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001 Emerson Process Management Bleigistrasse 23 P.O. Box 1046 H 6341 Baar Switzerland T +41 (0) 41 768 6111 F +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE T +971 4 883 5235 F +971 4 883 5312 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan rescent Singapore 128461 T +65 6777 8211 F +65 6777 0947 Service Support Hotline: +65 6770 8711 Email: Enquiries@AP.EmersonProcess.com 00840-0100-4130 Rev AA 09/10