Operation of WinVent 4.0

Similar documents
CISAP-2 2 nd International Conference on Safety & Environment in Process Industry CISAP-2. May, 21-24, 2006, Naples, Italy

SHAPA TECHNICAL PAPER 10 (Revised) SIZING OF EXPLOSION RELIEF VENTS DAVID BURN FIKE UK LTD

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

The Powerful Sealing Calculation

Gas Pressure Regulator HON 200

Pneumatic high-pressure controller Model CPC7000

Calculations of hydraulic resistance of simple pipelines for liquid viscous and non-newtonian products.

Hazard Operability Analysis

Tutorial. BOSfluids. Relief valve

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Type Testing Procedure for Crankcase Explosion Relief Valves

T208VR Series Tank Blanketing Vacuum Regulator

Rotary air valves used for material feed and explosion protection are required to meet the criteria of NFPA 69 (2014)

Laboratory studies of water column separation

Dimensioning of Safety Valves Auditorium Tecnimont

THE EXTERNAL EXPLOSION CHARACTERISTICS OF VENTED DUST EXPLOSIONS.

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Pressure Piping Code-Industrial Piping. Part 6: Safeguarding

Mass Spec will not Autotune

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

solids Rotary Valves Type ZRS

North American 7337A/B/C-4 High Pressure Gas Regulators

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

MRO Oil-Air Ratio Regulator

4-3 Rate of Change and Slope. Warm Up. 1. Find the x- and y-intercepts of 2x 5y = 20. Describe the correlation shown by the scatter plot. 2.

Pressure Relief Device Investigation Testing Lessons Learned

Instruction Manual Dräger MSI P7 and MSI P7 plus

ECL Comfort 110, application 131 (valid as of software version 2.00)

Manual Chapter 1. 1 st Generation 2 nd Generation

Operating instructions Pitot Static Tube

Ratio Regulator Zero Governor. FRG/6 Series

ANTI-EXPLOSION PANELS

Pneumatic high-pressure controller Model CPC7000

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications

6-5 Maintenance Manual

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

PRESSURE REDUCING VALVE RP45 (EN)

1305 Series Pressure Reducing Regulators

Steam generator tube rupture analysis using dynamic simulation

Installation and Operation Manual

Tank Blanketing Pressure Regulators RHPS Series

Körting Liquid Jet Vacuum Ejectors

OPERATING INSTRUCTIONS

Unofficial translation into English of the Sections of Swiss Standard SIA 262/1:2013 referring to in Situ Air-Permeability Tests

Gas Pressure Regulator HON 300

V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER

PSK Standards Association PSK 4917 Appendix 14

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

PASSENGER SHIPS Guidelines for preparation of Hull Structural Surveys

Explosion Isolation. No matter what happens - nothing happens. / RICO Slide Valve RSV-D, RSV-G, RSV-P

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

Karl Suss MJB4 Mask Aligner

SYSTEM FOR HYPERBARIC OXYGEN THERAPY MONOPLACE HYPERBARIC CHAMBER FOR MEDICAL TREATMENTS MODEL OXICAB MO-13-H TECHNICAL OFFER

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Bakery Flour-Handling equipment and ovens

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

EXPLOSION VENTING OF BUCKET ELEVATORS

HON 219 Pressure Reducer (D119a)

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Gas Pressure Regulator R 51

Comparison of Large-Scale Vented Deflagration Tests to CFD Simulations for Partially Congested Enclosures

CHE Well Testing Package/Service:

USER S INFORMATION MANUAL

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

The Discussion of this exercise covers the following points:

Section - III SYSTEMS DESCRIPTION

Table of contents. Table of contents 1. Installation 2. Introduction ( Display, monitor ) 3. Introduction ( Operating elements ) 4

The API states the following about tube rupture for a shell-and-tube heat exchangers:

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Committee on NFPA 85

Technical Data Sheet MF010-O-LC

ICHEME SYMPOSIUM SERIES NO. 144

Air preparation units

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Service Test Unit for ROSS Proportional Valves RESK

SIMULATIONS OF HYDROGEN RELEASES FROM A STORAGE TANKS: DISPERSION AND CONSEQUENCES OF IGNITION

WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION)

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

INSTALLATION GUIDE Gas Rangetops

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Additional sheet to leaflet Pressure regulators with safety assemblies, Print No Inlet pressures up to max. 1 bar Page 2

DESCRIPTION AND OPERATION OXYGEN SYSTEM OXYGEN SYSTEM

Engineering Models for Vented Lean Hydrogen Deflagrations

Nordiko Metal Sputtering System Standard Operating Procedure

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

Gas explosion venting protective systems

Low-Pressure Airjet-Filter MVRT

Combined Pressure / Vacuum Relief Valve KITO VD/o

Pump-Fan-Compressor Sizing

BMW proposal for. Technical requirements concerning LIQUID HYDROGEN STORAGE SYSTEMS. for the use in hydrogen powered road vehicles

Relief Systems. 11/6/ Fall

This document is a preview generated by EVS

Transcription:

1 Operation of WinVent 4.0 by Christoph Cesana and Richard Siwek Introduction The following will help to understand the use of WinVent 4.0. After starting WinVent 4.0 a decision must be made regarding the fuel involved in the design of a proper explosion venting system. When pushing one of the two fuel buttons the main window will appear. In the following example it will be Dust. Main window Main window of WinVent: This window summarizes 7 additional windows: Each one must be treated separately. After that the most important parameters will appear on the main window. F3 Vessel Silos: The position of the Vent Device on the Silos must be considering during the selection of a silo. Filters: The position of the Vent Device with respect to the filter elements is very important and must be taken into account during the selection of a filter. Cyclone: The only position of the Vent Device is on the top of the air outlet pipe. Therefore only the necessary pressure resistance has to be calculated. Building: For a proper design please consider the Handbook (Chapter 6.5) and EN 14491.

2 F4 Standard Dust Dispersion: Choose the type of dust dispersion and give the additional information. Default value is Standard (ISO/VDI) dispersion). This dispersion system is the most conservative. Note: In case of doubt use the standard dispersion. F5 Product data Product Data: Consider the wide scatter and large standard deviation of the laboratory data. To deal with this increase the laboratory data at least by 10%. Example: Pmax = 8.1 bar insert 9 bar and Kmax = 176 m*bar/s insert 200 m*bar/s. Indicate also if the dust is a metal dust or the dust contains solvent. F6 Disk / Vent Rupture Disk: For calculation of the vent area insert only the shape, the static activation overpressure Pstat, the vent efficiency EF and the specific weight GE of vent device. Flameless Vent: If a flameless venting device is used please use the rupture disk window.

3 F6 Door / Valve Explosion Door: For calculation of the vent area insert only the shape, the static activation overpressure Pstat, the vent efficiency EF and the specific weight GE of vent device. If the system is reclosing then insert the vacuum resistance of the vessel VRes for calculation the size of vacuum breakers. Flameless Valve: If an explosion relief valve system is used please use the explosion door window. Because this flameless valve is a re-closing system, installation of vacuum breakers must be considered. If so insert the vacuum resistance of the vessel VRes. R, P, K, S, A Calculation Calculation of... A = vent area... and without vent duct... R = resistance P = explosion overpressure K = product. spec. constant S = activation overpressure... as a function of other variables F7 Vent duct Position of vent duct: Choose the position of the vent duct: longitudinal or transversal. Note: Default value is transversal: This settings represents the worst case. Influence of vent duct: With this tool Winvent 4.0 shows the influence of the effective vent area Ae on the maximum reduced explosion overpressure Pred,max for the given situation.

4 Influence of Vent duct Example: V = 20 m³ L/De = 6 P max = 9 bar K max = 200 m bar/s P stat = 0.1 bar Problem With increasing vent area first the pressure decreases in order to rise again continuously after reaching a minimum! The standard EN14491calculates the maximum reduced explosion overpressure with vent duct with formula (17): P = P0 ( 1 + 17.3 LA (Ag V -0.753 ) 1.6 ) The formula gives this strange behavior. WinVent 4.0 takes the minimum pressure and keeps this value constant with increasing vent area (green line). No Influence of Vent duct The presence of the vent duct has no influence if the ratio of length to diameter LA/DE <= 0.5

5 F8 Addenda Recoil forces: WinVent calculates always: The recoil force maximum FRmax, The recoil duration IR and The transferred impulse IR. Flame length external to a vent: If the conditions for these calculations are fulfilled WinVent calculates: The flame range horizontally LFh, The flame range vertical LFv and The flame with WF. Pressure effects external to a vent: If the conditions for these calculations are fulfilled WinVent calculates: The external pressure max. PAmax at a distance of Rs and the external pressure Par at any distance r > R. Note: WinVent calculates always the worst case, that is horizontal venting and outside vent with secondary explosion. F2 Info We recommend to enter all comments and other information s in the corresponding fields in the window project - info rather than to edit the report. Changes in the report, e.g. added comment, would be lost!

6 Print the Report or... 1. Select a mask The WinVent-software contains some sample masks for the report in different languages. 2. Print the report The results of your calculations are then inserted automatically by the program in the mask and a report is produced. This can be edited as a whole and then printed out. Editing masks Aim and object of the mask is to enter repetitive text and to define all those fields in which variables should be entered automatically for the report. The WinVent-software contains some sample masks in different languages. These masks can be easily adapted to your requirements. Any Editor-program supporting the Rich-Text-Format (.rtf) is suitable (e.g. "Write", "WordPad" and "Word"). These masks are split into several sections. Each section starts with a "@:"-code. Please do never modify this codes. All fields for variables are marked by "#"-code. Advanced formatting features (e.g. tables, frames, background colors) are not supported. The functionality corresponds to "Write" or "WordPad".