Transmitter CS 21 Operation Manual

Similar documents
Transmitter CS 21 Operation Manual

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

Operation Manual. Transmitter IR 24. Models MWG 2491 / MWG Worldwide Supplier of Gas Detection Solutions

RAM 4021-DPX Operation Manual

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

RAM Operation Manual

MODEL GT820 OXYGEN SENSOR

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Sensoric 4-20 ma Transmitter Board Operation Manual

Instruction Manual Differential Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10

Instruction and Maintenance Manual

Technical Data Sheet MF010-O-LC

GasSense NDIR User Manual

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

210 Series Transmitter with External Electrochemical Sensor

MANUAL KPS Pressure Control Valve

O3 3E 1 F Gas Sensor Module

Pressure Measurement Single-range transmitters for general applications

RAM 4021 Operation Manual

Electro-Pneumatic Converter YT-940 SERIES

Operating Instructions

Instruction and Maintenance Manual

Best Practice Guide, Servomex 2700

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Installation, operating and maintenance Instructions for Seemag bypass level indicator

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

Operating Instructions Temperature Measuring System MF420-5T-100

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Model PDT Dewpoint Transmitter

INSTALLATION & MAINTENANCE INSTRUCTIONS

Visualize Nitrogen Gas Consumption

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Instruction Manual Contact Pressure Vacuum Gauge

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

444C DUAL PERFORMANCE VALUE PACK

Climatic Independent Level Sensor LAR

Hand-held pressure calibrator with integrated pump Model CPH6600

SANP ACTING RELAYS YT-520/525/530 SERIES

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

400C & 450C DUAL PERFORMANCE VALUE PACKS

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

GAS FUEL VALVE FORM AGV5 OM 8-03

Operation and Maintenance Manual

Columbus Instruments

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Datasheet: K-30 ASCII Sensor

Oxymax COS61/COS61D. Technical Information

200 PSI COMPRESSORS - MODEL NUMBERS

CSA Sample Draw Aspirator Adapter Operator s Manual

RGC-IR Remote Gas Calibrator for IR400

OXY 3690 MP. Measuring transducer for air oxygen

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

FTC130 Transmitter. Operating Manual

FLAMMABLE GAS SENSOR/TRANSMITTER

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Instruction Manual Differential Pressure Transmitter

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Operating Instructions Part No

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

ISM-3 User Manual PBI D 04/2013

Operating Instructions Part No

Installation and Operation Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

EPP4 Pressure Regulator Basic G 1/4"

100C Air Compressor Kit

with O 2 Controller Instruction Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

Electrochemical Sensor

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Electronic gas volume corrector model DGVC-04

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Pressure Transmitters 36 F-27839

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

IMPORTANT SAFETY INSTRUCTIONS

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

ME3-HCL Electrochemical sensor

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Transcription:

Transmitter CS 21 Operation Manual

Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical Connections 6 Putting in Operation 7 Check of Electrical Zero point 7 Check of Sensitivity 7 Service 9 Maintenance and Inspection 9 Trouble Shooting 9 Spare Parts 9 Accessories 9 Connection Diagram CS21 / Built-in Sensor 10 Connection Diagram CS21 / External Sensor 11 Technical Data 12 2

T Y P E L ABE L I N S I D E ME NU C H A N N E L O N F A U L T % For your Safety As any piece of complex equipment, the GfG transmitter CS21 will do the job designed to do, only, if it is used and serviced in accordance with the manufacturer's instructions. Please protect yourself and your employees by following them. All individuals who have or will have the responsibility for using and servicing this product must carefully read this manual. The warranties made by GfG with respect to the product are voided, if the adjustment of functions or parameters is changed without permission from GfG. They are also voided, if the product is not used and serviced in accordance with the instructions in this manual. Failures or false alarms caused by interfering gases or electrical signals are not part of the warranty obligation. The above does not alter statements regarding GfG s warranties and conditions of sale and delivery. General Description A fixed gas monitoring system consists of a transmitter and a control module, which are connected by means of a transmitter cable. The transmitter converts the gas concentration into an electrical signal, which is sent to the control module for evaluation. Fixed Gas Monitoring System A 3 ou N A3 nm A2 A1 U 100 80 60 40 20 A 2 A 1 F A ULT U TEST MENU QU T MENU Detection Evaluation Warning Fig. 1 The CS21 is an "intelligent" transmitter. Its comprehensive electronic circuitry allows easiest handling and servicing and increases the measurement reliability and accuracy. The CS21 is characterized by following features: Easy calibration at site. Long sensor life. 3

Detection Principle The CS21 is operated on the chemosorption principle. The basic element is a sensor, which is different depending on the application and the gas to be monitored. As long as there is no gas in the ambient air, the internal resistance of the sensor is rather high. As soon as gas is adsorbed at the sensor surface, the internal resistance is reduced. The change in resistance is the measure for the gas concentration and is converted to a standardized current signal (0.2.. 1 ma or 4.. 20 ma) by the integrated electronic circuit. The chemosorption principle has proven a good long-term stability and, depending on the sensor design, a good selectivity. Operational Notes Before shipment, the CS21 passes a function and display test, being calibrated with suitable test gases. This does not, however, overrule the obligation to arrange for another function test after putting the transmitter in operation. Design The design of the CS21 is shown in Fig. 2. The sensor is mounted in the sensor support (pos. 5). The gas enters the sensor chamber through the diffusion inlet (pos. 6). The casing (pos. 2) includes a resin encapsulated p.c. board with electronic components. The electronic circuit on the p.c. board converts the measurement signal into the output of 0.2.. 1 ma or 4.. 20 ma, which is supplied to the evaluation unit by means of the transmitter cable. CS21 Design 1. Casing top 2. Casing bottom 3. Type label 4. EMC cable gland (PG 11) 5. Sensor support 6. Diffusion inlet Fig. 2 4

Poti N CS21 Schematic Poti 0 (option) Poti C Test Contacts Resin Fuse 1 2 3 6 5 4 Terminals EMC cable gland-pg 11 Sensor Fig. 3 Mounting Position of CS21 It is essential to exactly know the ambient conditions, which have to be taken into consideration before deciding on the mounting position. To achieve representative measurement results, take care of the room ventilation and the gas density, the danger highlights. Install the CS21 at a place where the gases pass the sensor even in case of bad ventilation. If necessary, use a smoke cartridge to check. Furthermore, take the following into consideration as well: Ambient temperature, Rain, hose water, dripping water, condensate and Dust in the atmosphere. The CS21 is to a great extent protected against the entering of water and dust (IP 54). Special accessories are available to provide additional protection for very difficult conditions. Please contact GfG for detailed information.! Warranty may be voided, if the transmitter is exposed to ambient conditions that were unknown to GfG during planning, production or delivery. When deciding on the mounting position, make sure that the transmitter is easily accessible for service and calibration. Mount the transmitter with the sensor support showing to the floor, to facilitate service and maintenance. A different mounting position, however, does not affect the sensor accuracy. 5

Mounting The CS21 is connected to the controller according to the connection diagram (please also refer to the terminal diagram of your GMA controller). For mounting the transmitter remove the four special screws and take the casing top off. Fix the casing by means of two screws through the relevant borings. Inside the casing you see a resin encapsulated p.c. board with electronic components. The optional potentiometer 0 is factory-set and MUST NOT be turned.! The CS21 is not certified for use in hazardous areas. Installation of Electrical Connections A specialist must do procurement of cable and electrical connections only, obeying the applicable regulations. Depending on model or operation of the transmitter CS21, installation has to be done using a shielded 3-core 18 AWG cable. Connections Terminals Resin Terminals Resin 0 1 2 3 6 5 4 red red Sensor green yellow Signall Ground Voltage Supply EMC-PG 11 0 1 2 3 6 5 4 green brown white blue Sensor Signall Ground Voltage Supply EMC-PG 11 Sensor Connecting Wire, max. 2 m External Sensor Fig. 4 The supply voltage for the transmitter (terminal 4) is 10.. 32 V DC. Once the installation is completed, close the casing top and fix it with the screws. Note: Shielding is done over the EMC cable screwing. 6

Transmitter Casing Shield Transmitter Cable EMC Screwing The shield is to be connected to the transmitter casing by means of the cable screwing. Fix the shield as shown in above sketch. Fig. 5 Putting in Operation Once the CS21 is installed, a skilled person can put it in operation. Before shipment, the CS21 has been calibrated and tested after a running-in time of several days. You do not have to wait for so long, but once you have started your new CS21, the chemosorption sensor needs a certain running-in time of approx. 15-30 minutes before you can check the sensitivity. Should you notice that a re-calibration is required, allow the transmitter to warm up for about 4 hours. Check of electrical zero point The CS21 is calibrated and tested before shipment. Certain deviations, however, are possible due to transport, mounting and ambient conditions. Inside the CS21 there are two test contacts (fig. 3) to check the electrical output signal. The voltage at the test contacts can be measured by means of a voltmeter. After the warm-up time of approx. 30 minutes, the signal must be approx. 197 mv, this corresponds to an output current of 4 ma (4.. 20 ma interface). In case of deviation it is possible to re-adjust the value by turning potentiometer 0 Check of Electrical Dead Band (Should not be adjusted without GFG authorization) The CS21 is calibrated and tested before shipment. Certain deviations, however, are possible due to transport, mounting and ambient conditions. Inside the CS21 there are two test contacts (fig. 3) to check the electrical output signal. The voltage at the test contacts can be measured by means of a voltmeter. After the warm-up time of approx. 30 minutes, the signal must be approx. 200mV for zero gas *. This corresponds to an output current of 0.2 ma (0.2.. 1 ma interface) respectively 4 ma (4.. 20 ma interface). In case of deviation it is possible to re-adjust the value by turning potentiometer N. Alternatively, for example when using a GMA controller, you can check the transmitter signal at the controller. After the warm-up time of approx. 30 minutes, you can read the zero point voltage at the controller resp. check with a voltmeter (please read the operation manual of your GMA controller). In case of deviation you can correct it at the controller. Check of Sensitivity To check the sensitivity of the CS21 fix a calibration adapter to the diffusion inlet of the transmitter. Then select a suitable test gas, taking into consideration, which gas has been used for initial calibration of the transmitter. You can see this information from the test report. The test gas concentration should be at least 20 % above the second alarm threshold. The basic adjustment can be seen from the test report. * In this case, zero gas is not fresh air but test gas with 30 ppm of the gas to be monitored in air 7

Use a multimeter to check the output signal by measuring the voltage at the test contacts. The voltage is proportional to the output current. 200mV correspond to an output current of 0.2 ma (0.2.. 1 ma interface) resp. 4 ma (4.. 20 ma interface). 1000mV correspond to an output current of 1 ma (0.2.. 1 ma interface) resp. 20 ma (4.. 20 ma interface). In case of deviation you can correct the value by turning potentiometer C. Alternatively, for example when using a GMA controller, you can check the transmitter signal at the GMA. After the warm-up time of approx. 30 minutes you can read the signal voltage at the controller or check it with a voltmeter (please read the operation manual of your GMA). Should you notice a deviation, you can correct it at the GMA.! Do not use a test gas with a balance of nitrogen You must use an inline humidifier, and a ½ l/min. valve with test gas. For measurement accuracy it is important to use the end range gas to calibrate the CS 21. Adhere to the following procedure for checking the sensitivity: Suppress alarm transmission. Put calibration adapter on transmitter. Supply test gas to CS21 without pressure and with a flow rate of approx. 0.5 l/min. Within about 2-5 minutes a voltage corresponding to the gas concentration can be measured at the test contacts. Alternatively the calibration can be checked at the GMA controller. Is the measured value equivalent to the calibration curve? yes no Re-adjust calibration by turning potentiometer C. Alternatively: Re-adjust calibration point at GMA controller. Please refer to the operation manual of your GMA controller. Disconnect test gas and calibration adapter. Disconnect alarm suppression. 8

Service This function checks: Check with alarm gas concentration Check of zero point and sensitivity (calibration) Check of response time Check of gas sampling and gas processing system (if any) Check of alarm signal activation Check of failure alarm An expert, who has to report the result in written form, must do the check. Generally the calibration intervals should not exceed 16 weeks. The function check is to be done before putting the system in operation, and it has to be done at least once a year. Maintenance and Inspection Maintenance and inspection mean measures that ensure the planned status of the gas monitoring system. The CS21 does not require special maintenance, a few points should be obeyed yet. Depending on the ambient conditions, gas monitoring systems may show a different behavior. It is important, therefore, to do a visual check every day, particularly during the first few days after putting in operation. Check of gas processing system and filters (if any). Check of gas supply for soiling or obstacles (for correct measurement the gas supply to the sensor must not be blocked). Sensors are subject to ageing and exhausting. Depending on their type and on their exposure to gas they are more or less used up, so a sensitivity check can only be done with a suitable test gas after certain periods. The sensitivity calibration is an expert calibration and is usually done by GfG service or by authorized persons. Trouble Shooting Failure Reason Solution Zero point cannot be adjusted Faulty sensor Replace sensor Full scale value cannot be set Faulty sensor Replace sensor Output current has fallen to 0 ma Spare Parts Defective fuse Defective electronics Faulty sensor Cable cut Replace fuse Replace p.c. board Replace sensor Re-fix connection Part No. Casing top 2211301 Accessories Part No. Screw-on calibration adapter 2000209 9

Connection Diagram CS21 / Built-in Sensor Built-in Sensor MK red green yellow white green brown 1 2 3 4 5 6 Connect shield to Cable Gland 0.2-1 ma GND 20V / 24V GMA 300 2 1 5 GMA 011 2 1 5 GMA 100 2 1 5 Motherboard from 1997 (blue) GMA 100 2 0 3 Motherboard until 1996 (no color) GMA101 2 1 5 GMA41 30 29 28 GMA81 (A) 3 2 1 10

Connection Diagram CS21 / External Sensor MK External Sensor brown green white white green brown 1 2 3 4 5 6 Connect shield to Cable Gland 0.2-1 ma GND 20V / 24V GMA 300 2 1 5 GMA 011 2 1 5 GMA 100 2 1 5 Motherboard from 1997 (blue) GMA 100 2 0 3 Motherboard until 1996 (no color) GMA101 2 1 5 GMA41 30 29 28 GMA81 (A) 3 2 1 11

Technical Data Transmitter CS21 Type: CS21 Sensor Type (MK): see test report Gas: See test report Range: see test report Gas Supply: Diffusion Detection Principle: Chemosorption (CS) Supply Voltage: 10.. 32 V DC Output Current: 0.2.. 1mA (4kΩ) or 4..20mA (200Ω) Response Time t A : < 14 s (depending on gas) Typical Sensor Life: > 5 years Climate Conditions Operational Temperature: - 30.. + 55 C Humidity: 20.. 96 % r. h., non condensing Atm. Pressure: 920.. 1100 hpa Casing Material: Aluminum Protection: IP 54 Cable Gland: PG 11 screwing, max. cross section 3 x 1.5 mm2 Transmitter Cable: Shielded cable - #18/3 shielded or Belden 8770 equal Dimensions: 100 x 100 x 57 mm (WxHxD) Weight: approx. 370 g 12

1194 Oak Valley Drive, Suite 20 Ann Arbor, Michigan 48108 United States of America Phone: (800) 959-0329 or (734) 769-0573 Fax (734) 769-1888 E-mail: info@gfg-inc.com Website: www.gfg-inc.com GfG reserves the right of modification. 6-9-06 JA 7004-CS21