Pressure Sensing Valve - Model 4023

Similar documents
Low Pressure Valve. Model Overview. Typical applications. Key features and benefits.

Choosing the right miniature instrument and control valve is a snap

Installation, Operation and Maintenance Manual for Back Pressure Regulator

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q= Cv S

Type R622 Pressure Reducing Regulator

64 Series Pressure Reducing Regulators

1805 Series Relief Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

1805 Series Relief Valves

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Related Products: Auto Drain Valve. Model/Specifications. Model

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Precision and Instrument Regulators 1/4" port size

Model Series 62 Constant Differential Relay

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

TECHNICAL DATA. Q = C v P S

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Type FEQ Slam-Shut Valve

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

1305 Series Pressure Reducing Regulators

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Data Sheet Issue A

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Hydraulic Punch Drivers

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

TECHNICAL DATA. Q = C v P S

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Pneumatic Powered - Plunger Pumps

V43 Pressure Actuated Water Regulating Valve

Type 92S Pilot-Operated Steam Regulator

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Air Operated Hydraulic Pumping Systems to 50,000 psi

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

TECHNICAL DATA CAUTION

Suggested Installation & Operating Instructions for Sidewinder Pumps

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

Type CT88 Backpressure Regulator

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA OBSOLETE

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Operator: Save these instructions for future use!

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

Anti-flood device Model B-1

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

1301 Series High-Pressure Regulators

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

TECHNICAL DATA. Page 1 of 12

Pressure Dump Valve Service Kit for Series 2300 Units

Right-Angle Tube Roller Model

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Type EZH Relief or Backpressure Regulator

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Instruction Manual Updated 7/26/2011 Ver. 2.2

1200B2 Series Service Regulators. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Directional Valves. Hydraulic Operated Directional Valves

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

1200 Series Pressure Regulators

PRO-50 Instrument Supply Regulator

WHEATLEY Series 822/820 Swing Check Valve

Operation Manual Piston Sensed Gas Pressure Regulators

Actuator HON 670 / 671

100C Air Compressor Kit

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Standard Specifications

Type 63EG Relief Valve or Backpressure Regulator

PNEUMATIC PRESSURE CONTROLLERS

Transcription:

Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge pressure sensing at high pressure levels. Dual purpose construction provides a wide latitude of applications and permits easy field adjustment or changeover from trip on falling to trip on rising pressure. Trip settings are adjustable in eight ranges from 1.2 bar (18 psi) falling to 524 bar (7600 psi) rising pressure. The 4023 valve is suitable for use on air, hydraulic, or gas control systems with control systems pressure up to 8.6 bar (125) psi. Typical applications Well head control Actuator piloting valve Suction/discharge pressure Key features and benefits Setting to 524 bar (7600 psi) 2 or 3-way action Balanced 3-way valve - pressure can be applied to any port 3-way valve suitable for LP gases, natural gas, oil, air etc Bubble-tight seals with center dead spot (no port overlap) Field adjustable - rising or falling Adjustable setpoint Gulfproof finish standard

Pressure Sensing Valve - Model 4023 Operation The 3-way valve has a pressure actuated, spring return operator. Without pressure applied to the sensed pressure port, Port 3 is open to Port 2. With pressure applied to the sensed pressure port, Port 3 closes before Port 1 opens to Port 2. A small dead spot on the center of the stroke prevents valve port overlap. The valve is normally set at the factory so that Port 1 just opens to Port 2 on a pressure rise to the specified tripping pressure setting. The valve is converted to 2-way action by plugging Port 1 or Port 3. A manual reset feature is available to reset the valve after tripping. Pull out the reset knob to reset after trip on falling pressure. Push in the reset knob to reset after trip on rising pressure Units with pressure range code numbers 1 and 2 use a diaphragm with a gulfproofed aluminum housing to sense pressure. Units with a higher pressure range use a Teflon lip-type seal on a stainless steel piston inside a stainless steel cylinder to sense pressure. Specification Housings Piston and cylinder 3-way valve spool Standard seals and diaphragm Piston seal Anodized aluminum Stainless steel Anodized aluminum Nitrile/Buna N Teflon Maximum Operation Pressure at Ports 1, 2 and 3 8.6 bar (125 psi) Maximum Temperature 66 C (150 F) Valve free flow area (9/32 diameter port) Kv = 1.0 Cv = 1.2 Net weight 1.81 kg (4 lbs) Shipping Weight 2.26 kg (5 lbs) Installation Model 4023 can be mounted in any position. Use two 1/4 diameter screws through the holes in the back of the case, or two 3/8-16 screws into the case through a mounting plate on the back side. When manual reset (trip on falling pressure) is included, the valve should be mounted with the reset knob down. With manual reset (trip on rising pressure), the valve should be mounted with the reset knob up. Frictional force of the seal rings holds Valve Spool (20) in position. Machine vibration can cause the valve to reset if not mounted as instructed. for a long period of time, the Teflon seal may leak slightly. It is recommended that this seal be exercised by running the sensed pressure up and down its complete range about six times to overcome any leakage problems. Control pressure, sensed pressure sources and interconnecting tubing must be free of dirt, chips, rust and other contaminants. Apply a quality thread sealant such as Loctite Pipe Sealant to pipe thread connections. Avoid applying excessive torque on fittings at Ports 1, 2 and 3. If a 4023 valve with pressure code range numbers 3 or higher have been in stock without being used page 2

Installation continued Pressure Sensing Valve - Model 4023 Maintenance Properly applied and installed 4023 valves require minimal maintenance. Unless leakage or other problems are noticed earlier, an inspection of the units at yearly intervals is adequate to detect and make provision for normal wear and preventive maintenance. It is recommended that Model 4023 be checked monthly for proper functioning by simulating an unsafe condition. AMOT designs and tests all products to ensure that high quality standards are met. This product should last for many years. For good product life, carefully follow the installation and maintenance instructions; failure to do so could result in damage to the equipment being protected. Service kits Service Kit 9132X - Model 4023E1--A, E2--A 19 4 Seal Ring, Buna N 58 1 O-ring, Buna N 59 1 Diaphragm, Buna N Service Kit 9132X0001 - Model 4023E1--C, E2--C 19 4 Seal Ring, Buna N 58 1 O-ring, Buna N 59 1 Diaphragm, Buna N Service Kit 9155X001 - Model 4023E3--D, E3--D 3 4 Seal Ring, Teflon 4 1 O-ring, Buna N 5 1 O-ring, Viton 19 4 Seal Ring, Viton Service Kit 9155X003 - Model 4023E5--D, E6--D 4 1 O-ring, Buna N 5 1 O-ring, Viton 19 4 Seal Ring, Viton 33 1 Seal Ring, Teflon page 3

How to order Pressure Sensing Valve - Model 4023 Use the tables below to select the unique specification of your 4023 Pressure Sensing Valve: Example: Model 4023E A B C D A Pressure Range bar (psi) Rising Falling Differential Proof 1 1.4-3.4 (20-50) 2 2.1-8.6 (30-125) 3 9.0-27.6 (130-400) 4 17.2-55.2 (250-800) 5 27.6-75.8 (400-1100) 1.2-3.4 (18-50) 1.7-7.9 (25-115) 6.8-25.5 (100-370) 13.8-48.3 (200-700) 19.0-62.1 (275-900) 0.28-0.48 (4-7) 0.48-0.83 (7-12) 2.4-3.4 (35-50) 3.2-4.1 (46-60) 6.9-10 (100-145) 24 (350) 24 (350) 103 (1500) 103 (1500) 241 (3500) B Port Threads and Finish Thread Finish 4 NPT Anodized (Gulfproof) C Reset Type 0 Automatic 1 Manual 3 Pneumatic (Special Order) D A C D Seal Material Buna N (Nitrile) for pressure ranges 1 and 2 Viton for pressure ranges 1 and 2 Viton for pressure ranges 3 to 8 6 44.8-155.1 (650-2250) 34.5-137.9 (500-2000) 8.3-11.7 (120-170) 241 (3500) 7 68.9-241.3 (1000-3500) 51.7-206.8 (750-3000) 20.7-27.6 (300-400) 690 (10000) 8 100-524 (1450-7600) 68.9-482.6 (1000-7000) 27.6-41.4 (400-600) 690 (10000) page 4

Dimensions Pressure Sensing Valve - Model 4023 1.4 [36.5] 1.1 [28.6] Manual reset after trip on rising or falling pressure 1.1 [28.6] 1/4 Pipe Thread 1.1 [28.6] 3 Ports 1/4 - NPT Pneumatic reset only after trip on rising pressure 0.8 [20.6] 0.8 [20.6] 2.0 [50.8] 7.2 [182.6] 2 Mounting holes tapped 3/8-16 N.C. through back of Case. Can take 1/4 O.D. bolts. 7.8 [196.9] 0.6 [15.9] 3.0 [76.2] Sensed Pressure Port 1/4 - NPT Pipe Thread 0.6 [15.9] 2.1 [54.0] 2.1 [54.0] 7.1 [179.4] 1.0 [25.4] 0.9 [22.2] 2.2 [55.6] 0.9 [23.8] Note: Drain hole may be rotated 360. Drain 1/8 - NPT Pipe Thread Pressure Range Codes 7 and 8 only Pressure Range Codes 3-8 only Pressure in marked P 2.9 [73.0] 8.3 [209.6] Overall page 5

Americas AMOT USA 8824 Fallbrook Dr Houston TX 77064 USA Tel: +1 (281) 940 1800 Fax +1 (713) 559 9419 Email sales@amotusa.com Europe, Middle East, Africa AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Tel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email info@amot.com Asia Pacific AMOT Shanghai Rm 4102-4104 United Plaza 1468 Nanjing Road West Shanghai 200040 China AMOT Controls GmbH Rondenbarg 25 22525 Hamburg Germany Tel +49 (0) 40 8537 1298 Fax +49 (0) 40 8537 1331 Email germany@amot.com Tel +86 (0) 21 6279 7700 Fax +86 (0) 21 5237 8560 Email shanghai@amot.com AMOT Singapore 10 Eunos Road 8 #12-06 Singapore Post Centre Singapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email singapore@amot.com www.amot.com