DRAW WIRE SENSOR. Series SX draw wire mechanics for encoder assembly. Content: Key-Features:

Similar documents
Draw-wire system SZG165

INSTALLATION GUIDE FIRST STEPS MOUNTING OF THE SENSOR HANDLING THE WIRE ROPE

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

CFSW. Hinges with built-in safety multiple switch

Hoisting Equipment Cable puller & Accessories

INSTALLATION INSTRUCTIONS

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

CFSW. Hinges with built-in safety multiple switch

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

[Instruments for vacuum measurement, checking and adjustment] 3

C-Flow Coriolis Mass Flow Meters

Prewired position switches FA series

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Expansion Thermometers Stainless Steel Series, Model 70

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

pneumatic power clamps

TECHNICAL INFORMATION

Preferred Instruments Danbury, CT USA

AMS 2710 PCB pressure sensor module with V output

Deluxe Gourd Racks I D E G A. Parts List. Shown above are parts for the two-level, Deluxe Gourd Rack (DGR 12V)with 12 arms for vertically hung gourds.

INSTRUCTION MANUAL. January 23, 2003, Revision 0

User Manual V14.1 IP68 LED FLEX NEON

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

Boat Boat Loader Fitting Instructions

Flow controller Type ED/CCB311 Instruction manual

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Mass Flow Controller (MFC) for Gases

Instruction Manual Differential Pressure Transmitter

Level transmitter LT 100

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Mass Flow Controller (MFC) for Gases

Infrared Linescanners

TECHNICAL INFORMATION

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Manual winch MANISTOR 100 and 200

Pneumatic spool valve islands

Mass Flow Meter (MFM) for gases

DPS-400 SERIES DPH-100 SERIES

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

TRAVSMART permanent single-cable horizontal lifeline system

10.2. Basketball Single Post System

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

GWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight

Pressure Dump Valve Service Kit for Series 2300 Units

Order No Projection Backboard

CHAPTER 5 REWIND STARTERS

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Coiling Tube with Twist-Proof Fitting

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

MANUAL KPS Pressure Control Valve

Hand lever valves VHER

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

SpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

Position switches FP series

Magnetic level switch type MR783 Instruction Manual

Security and confidence at height.

Figure 1 - Parts Identification

INSTRUCTION MANUAL Pressure Relief Device LPT

Sizes Weight Gripping force Stroke per finger Workpiece weight Pieces : kg N mm kg

Retrofitting Green SkiErg Handles

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Torque Tube TB300 Digital Transmitters

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Saab Seaeye Cougar XT Compact

PZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

Rolled Rotary Ball Screw

ATS430 turbidity sensor Retractable insertion assembly

2-jaw self-centering pneumatic parallel gripper (series SX)

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

AREA VALVE SERVICE UNITS

Hand winch MANIBOX VS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Hand winch MANIBOX GR

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

MagneticTurbo TM. TurboDrag pumps with pumping speed up to 1500 l/s TMH/U 1000 M / TMH/U 1600 M. Pumping speed. Start / Chapter content

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

JUMO dtrans p30 Pressure Transmitter

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

OXYGEN MONITORING SYSTEM OMS

MSA Latchways Ladder System

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Transcription:

DRAW WIRE SENSR Series SX draw wire mechanics for encoder assembly Content: Introduction...2 Technical Data...3 Technical Drawing...4 s...5 Encoder Mounting...6 Sensor Mounting...7 Accessories...8 rder Code..10 KeyFeatures: Fast and easy encoder mounting Measurement ranges from 1.0 to 42.5 m Linearity ±0.05% of full range (with encoder) al high corrosion protection Temperature range 20...+85 C (optional 40 C) High dynamics Customised versions available 18.01.17

2 INTRDUCTIN WayCon Positionsmesstechnik GmbH is a manufacturer of high quality draw wire position sensors for industrial use. Due to its small overall size, its short assembly time and its possible customisation, the SX sensor technology is a costeffective and flexible solution for a wide range of industrial applications. The dynamics of the draw wire transducer allows a high motion speed and acceleration of the measuring target. Its rugged design and high quality makes applications in harsh industrial environments possible. Special instruments are available with mounting service of encoder on site, as well as customised versions of housing. Sensor principle: The key component of a draw wire sensor is a highly flexible steel wire rope, that is winded singlelayered on an ultra light capstan. This capstan is connected to the sensor housing by a prestressed spring. The end of the steel wire rope, that is equipped with a rope clip gets connected to the target object. As soon as the distance between sensor and target object changes, the steel wire rope gets pulled out of the sensor and is rolled off the capstan (or vice versa). The shaft of the capstan is connected to a potentiometer (for analog output signals), or to an encoder (for digital output signals). If there is a rotation of the capstan due to a change in the distance to the target object, the sensor element will turn proportionally. This way the potentiometer, or the encoder converts a linear movement into a proportional electrical signal. If a standard analog output signal, like 0...10 V or 4...20 ma is needed, the sensor is equipped with an additional electronics. rotating shaft sensor element: potentiometer measuring rope rope capstan example: SX50 tension spring electronics: converts the potentiometer output into an analog output SPECIAL FEATURES easy rope fixation with rope clip ball bearing drill protection flexible and shielded sensor cable measuring rope (stainless steel) M12connector system or cable output bushing anodised aluminium housing waterproof housing IP65 or IP67 dynamic spring drive with PA6 case for high displacement speed 2 ball bearings high linearity quick and easy mounting WARNING NTICES Don t let the rope snap back. If the rope is retracted freely, this may lead to injuries (whiplash effect) and the device may be damaged. Caution when unhooking and retracting the rope into the sensor. Never exceed the specified measurement range when extracting the rope! Do not try to open the device. The stored energy of the spring drive may lead to injuries when being mishandled. Do not touch the rope when operating the sensor. Avoid guiding the rope over edges or corners. Use a deflection pulley instead. Do not operate the sensor if the rope is buckled or damaged. A ripping of the rope may lead to injuries or a damaging of the sensor.

3 TECHNICAL DATA SX80 Measurement range [mm] 1000 1500 2000 2500 3000 Linearity ±[%] 0.05 (with encoder output) Disc circumf erence [mm] 200 Temperature [ C] standard: 20...+85 / optional: 40...+85 (please pay attention to maximum permitted encoder temperature) Weight [g] 700 to 900, depending on the measurement range Housing aluminium, anodised, spring case PA6 Encoder requirements clamping flange (diameter 36 mm), a shaft diameter of 10 mm and a shaft length of 10 20 mm Accessories cables, connectors, digital display s, def lection pulley, rope extensions, magnetic clamp (see pages 9 and 10) Measurement range [mm] Extraction Force F min [N] Extraction Force F max [N] Speed V max [m/s] Acceleration a max [m/s²] 1000 4.2 5.4 8 120 1500 4.2 5.4 8 120 2000 5.0 6.4 8 120 2500 5.0 6.4 8 120 3000 5.0 6.4 8 120 TECHNICAL DATA SX120 Measurement range [mm] 3125 4000 5000 Linearity ±[%] 0.05 (with encoder output) Disc circumf erence [mm] 317.68 Temperature [ C] standard: 20...+85 / optional: 40...+85 (please pay attention to maximum permitted encoder temperature) Lif e expectancy approx. 2 million f ull strokes (dependent on the displacement speed) Weight [g] 1300 to 1600, depending on the measurement range Housing aluminium, anodised, spring case PA6 Encoder requirements clamping flange (diameter 36 mm), a shaft diameter of 10 mm and a shaft length of 10 20 mm Accessories cables, connectors, digital display s, def lection pulley, rope extensions, magnetic clamp (see pages 9 and 10) Measurement range [mm] Extraction Force F min [N] Extraction Force F max [N] Speed V max [m/s] Acceleration a max [m/s²] 3125 8.0 10.0 8 120 4000 8.0 11.0 8 120 5000 8.0 11.6 8 120 TECHNICAL DATA SX135 Measurement range [m] 6.0 7.0 8.0 10.0 12.0 15.0 20.0 25.0 30.0 35.0 40.0 42.5 Linearity ±[%] 0.05 (with encoder output) Disc circumf erence [mm] 357.14 333.33 Temperature [ C] standard: 20...+85 / optional: 40...+85 (please pay attention to maximum permitted encoder temperature) Lif e expectancy approx. 2 million full strokes (dependent on the displacement speed) Weight [g] 3200 to 5000, depending on the measurement range Housing aluminium, anodised, spring case PA6 Encoder requirements clamping flange (diameter 36 mm), a shaft diameter of 10 mm and a shaft length of 10 20 mm Accessories cables, connectors, digital display s, def lection pulley, rope extensions, magnetic clamp (see pages 9 and 10) Measurement range [mm] Extraction Force F min [N] Extraction Force F max [N] Speed V max [m/s] Acceleration a max [m/s²] 6 7.8 13.6 8 120 7 8.2 15.0 8 120 8 8.2 15.2 8 120 10 / 12 4.8 7.2 6 80 15 6.8 11.2 6 80 20 6.4 9.2 5 60 25 7.8 11.4 5 60 30 6.4 9.6 5 60 35 7.4 11.6 5 60 40 / 42,5 5.4 9.0 5 60

4 TECHNICAL DRAWING SX80 SX120 SX135

5 INSTALLATIN Mount the sensor at the designated place by using the fixing holes before extracting the rope and before attaching the rope to the measuring target. pen the rope clip after the sensor is fully mounted and extract the measuring rope. Hook the rope clip on the measuring object and close the bracket of the clip. For safety reasons put a screw driver trough the clip to extract the rope. Check the track of the measuring target on collision with the sensor housing and on exceeding the specified measurement range. When installing the sensor make sure that the rubber stopper does not touch the rope outlet. Connect the electronics according to the sensor type. When laying the cables be careful not to underrun the minimal allowed bending radius of the cable (5 x cable diameter). The rope must be extracted from the sensor vertically. The maximum variation from the vertical is 3. Avoid carefully extracting the rope at an inclination, since the durability of the instrument would shorten considerably. If it is not possible to keep the limit of 3, a deflection pulley has to be used. The measuring range begins after approximately 2 mm extracted rope (=zero point). The mechanical reserve at the end of the measuring range is about 20 mm. When mounting outdoors protect the sensor and the rope from icing at temperatures below 0 C. Guide the rope preferably in corners or guarded in channels to prevent pollution or accidental touch. When operating the sensor, take care not to let the rope snap back by mistake or extract the rope over the specified measurement range, as this might destroy the sensor. Maintenance: These instruments are maintenancefree. If however, the rope is soiled due to adverse environmental conditions, it can be cleaned with a cloth drenched in resinfree machine oil. PTINS rder code Corrosion protection CP (e. g. sea water) with a hard ceramicslike layer. Increased temperature range Low Special components and a low temperature grease make a working temperature down to 40 C (up to +85 C) possible. Rope fixation by thread al, pivoted rope fixation Includes a V4A wire rope, stainless steel bearings and option. The sensors rope drum gets HARTCAT coated. This coating is a hardanodic oxidation that protects the sensor from corrosion by aggressive media with screw thread, length 22 mm. Ideal for attachment to through holes or thread holes. rope clip with drill protection (standard) optional rope fixation Ring eye The end of the wire rope is equipped with a ring ey e instead of a rope clip. Inside diameter 20 mm

6 Befestigungsmöglichkeiten SX80, SX120, SX1358 ENCDER ASSEMBLY 1. Please insert the encoder into the clamping flange. 2. The encoder is now connected to the clamping flange. 3. By tightening (approx. 2 Nm) the inner radial screw with a 2.5 mm hex wrench the encoder shaft will be clamped to the sensor mechanics and secured from twisting. 4. By tightening (approx. 2 Nm) the outer radial screw with a 2.5 mm hex wrench the encoder housing will be clamped to the sensor housing and secured from twisting. The system is now ready to be used. Befestigungsmöglichkeiten SX135 ENCDER ASSEMBLY BY EASYCLAMPMECHANISM IMPRTANT: All incremental and absolute encoders must have a clamping flange (diameter 36 mm), a shaft diameter of 10 mm and a shaft length of 1020 mm. 1. Please mount the included coupling (1) on the shaft of the encoder and fix the set screw (1.0 Nm). Therefore you will need a hexagon screwdriver, size 2. Please pay attention that the dimension between contact surface of the encoder and the end of the cylinder bolt is 35 mm. 2. Please mount the encoder into the easyclampflange. The cylinder bolt must slip into the spring (2). 3. By tightening (1.5 Nm) the radial screw the encoder will be clamped and secured from twisting. Please use a hexagon screwdriver, size 3. (1) (2)

7 SX80, SX120 MUNTING PTINS SX80, SX120: standard rope outlet, rope outlet sideways top (S1) The sensor is usually installed by using the regular mounting plate (see technical drawing on page 4). By disassembling the mounting plate, there are 4 threads (2 x M3, 2 x M5) in the sensor housing for alternative installation. SX80: rope outlet sideways bottom (S2), rope outlet bottom (S3) Sensors with option rope outlet S2 and S3 have a modified base plate. SX120 rope outlet sideways bottom (S2), rope outlet bottom (S3) Sensors with option rope outlet S2 and S3 have a modified base plate. SX135 MUNTING PTINS 1. by using the grooves in the sensor housing The included Tslot nuts can be easily inserted into the grooves of the sensor housing. The nuts have a metric thread M6. Each sensor up to 20 m measurement range comes with 2 nuts, from 20 to 42.5 m four nuts are included. 2. by angle clamp brackets The angle clamp brackets feature a bore for M6 screws to fix it on a plate/ slab or a profile. Each sensor up to 20 m measurement range comes with 2 brackets, from 20 to 42.5 m four brackets are included. 2 Important: The grooves of the sensor housing, the nuts and brackets are compatible to the aluminium building kit system from item Industrietechnik GmbH (www.item.info). 1 Position of the grooves: Mounting by using brackets:

8 ACCESSES Deflection pulley UR2 The rope must be extracted from the sensor vertically. The maximum variation from the vertical is 3. A deflection pulley allows a change in the direction of the wire rope. Several pulleys may be used. The rope clip must not be guided over the deflection pulley. material: anodised aluminium, PM mounting: by 2 hexagon socket or countersunk screws M6, vertical or horizontal mounting possible. Ball bearings: with special low temperature grease and RSsealing. Temperature: 40...+80 C. Rope extension SV For bridging a greater distance between the measuring target and the sensor a rope extension can be applied. The rope clip must not be guided over the deflection pulley. Please specify the length needed in your order (XXXX). The minimum length is 150 mm: SV1XXXX: rope extension (150...4995 mm) SV2XXXX: rope extension (5000...19995 mm) SV3XXXX: rope extension (20000...40000 mm) Magnetic clamp MGG1 Use the magnetic clamp to quickly attach the rope to metallic objects without any assembly time. A rubber coating provides gentle contact (e. g. on varnished surfaces) and prevents from slipping due to vibration. The magnet consists of a neodym core for an increased adhesive force of 260 N. The hook makes it easy to attach the rope clip.

9 ACCESSES DIGITAL UTPUT INCREMENTAL Cable with connector M12, 8 poles, shielded Mating connector M12, 8 poles, shielded Mating connector M23, 12 poles K8P2MSM12 2 m, connector straight D8GM12S mating connector straight CN012S straight, metal housing K8P5MSM12 5 m, connector straight D8WM12S mating connector angular wire diameter: AWG 16...26 mm² K8P10MSM12 10 m, connector straight protection class: IP67 cable diameter: ø 5.5...10 mm K8P2MSWM12 2 m, connector angular temperature: 25...+90 C K8P5MSWM12 5 m, connector angular cable passage: ø 4...8 mm K8P10MSWM12 10 m, connector angular wire diameter: 0.14...0.34 mm² CN012S Digital distance and speed display WAYD for incremental output signals Use the WAYD display to visualise the measured distance or the speed (tachometer) of the position transducer. A transfer of data to a PC or PLC can be done with the RS232 interface of the WAYDR. Protection class: IP65 (front panel) Display: 6 digits Supply: 115 / 250 VAC utput Linedriver L (TTL, RS422): WAYDS5VH: WAYDG5VH: WAYDR5VH: display only, input level TTL display with two presets and switching outputs, input level TTL display with serial interface RS232 / RS485, input level TTL utput PushPull G: WAYDS: WAYDG: WAYDR: display only, input level HTL display with two presets and switching outputs, input level HTL display with serial interface RS232 / RS485, input level HTL For further information please see the WAYD data sheet. ACCESSES DIGITAL UTPUT ABSLUTE SSI output: CANopen output: K12P02MSM23SSI K12P05MSM23SSI K12P10MSM23SSI K12P15MSM23SSI 2 m cable, shielded, M23 connector straight K5P2MBM12CAN 2 m cable, plug f emale M12, 5 poles, open ends 5 m cable, shielded, M23 connector straight K5P2MSBM12CAN 2 m cable, connector male M12, 5 poles, plug f emale M12 10 m cable, shielded, M23 connector straight K5P2MSM12CAN 2 m cable, connector male, M12, 5 poles, open ends 15 m cable, shielded, M23 connector straight EtherCAT / Profinet: CN012S Mating connector M23 shielded, straight, 12 poles K4P2MSM12CAT 2 m cable, connector male M12, 4 poles, open ends Profibus DP: K4P5MSM12CAT 5 m cable, connector male M12, 4 poles, open ends K5P2MBM12PRF 2 m cable, plug f emale M12, 5 poles, open ends K4P10MSM12CAT 10 m cable, connector male M12, 4 poles, open ends K5P2MSBM12PRF 2 m cable, connector male M12, 5 poles, plug f emale M12 K4P2MSSM12CAT 2 m cable, connector male M12 on both ends, 4 poles K5P2MSM12PRF 2 m cable, connector male, M12, 5 poles, open ends K4P5MSSM12CAT 5 m cable, connector male M12 on both ends, 4 poles M12PRFAW terminator K4P10MSSM12CAT 10 m cable, connector male M12 on both ends, 4 poles Digital distance and speed display WAYSSI for SSI output signals Use the WAYSSI display to visualise the measured distance or the speed (tachometer) of the position transducer. A transfer of data to a PC or PLC can be done with the RS232 interface of the WAYSSIR. Protection class: IP65 (front panel) Display: 6 digits Supply: 115 / 250 VAC WAYSSIS: WAYSSIA: WAYSSIG: WAYSSIR: display only display with analog output display with two presets and switching outputs display with serial interface RS232 / RS485 For further information please see the WAYSSI data sheet.

10 SX80 RDER CDE DRAW WIRE MECHANICS SX80 F58NK Measurement range [mm] 1000 / 1500 / 2000 / 2500 / 3000 S1 S2 S3 rope fixation be thread synthetic wire rope, made out of Coramid rope outlet sideways top rope outlet sideways bottom rope outlet bottom increased temperature range low 40...+85 C corrosion protection SX80 ranges 2500/3000 mm, SX120 RDER CDE DRAW WIRE MECHANICS SX120 F58NK Measurement range [mm] 3125 / 4000 / 5000 S1 S2 S3 rope fixation be thread synthetic wire rope, made out of Coramid rope outlet sideways top rope outlet sideways bottom rope outlet bottom increased temperature range low 40...+85 C corrosion protection SX120, SX135 UP T 8.0 M RDER CDE DRAW WIRE MECHANICS SX135 F58NK Measurement range [m] 6 / 7 / 8 rope fixation be thread synthetic wire rope, made out of Coramid increased temperature range low 40...+85 C corrosion protection SX1356/7/8 ranges 7 / 8 m,

11 SX80 RDER CDE DRAW WIRE MECHANICS SX80 F58NK Measurement range [mm] 1000 / 1500 / 2000 / 2500 / 3000 S1 S2 S3 rope fixation be thread synthetic wire rope, made out of Coramid rope outlet sideways top rope outlet sideways bottom rope outlet bottom increased temperature range low 40...+85 C corrosion protection SX80 ranges 2500/3000 mm, SX120 RDER CDE DRAW WIRE MECHANICS SX120 F58NK Measurement range [mm] 3125 / 4000 / 5000 S1 S2 S3 rope fixation be thread synthetic wire rope, made out of Coramid rope outlet sideways top rope outlet sideways bottom rope outlet bottom increased temperature range low 40...+85 C corrosion protection SX120, SX135 UP T 8.0 M RDER CDE DRAW WIRE MECHANICS SX135 F58NK Measurement range [m] 6 / 7 / 8 rope fixation be thread synthetic wire rope, made out of Coramid increased temperature range low 40...+85 C corrosion protection SX1356/7/8 ranges 7 / 8 m,

12 SX135 10.0 M AND GREATER RDER CDE DRAW WIRE MECHANICS SX135 F58K Measurement range [m] 10 / 12 / 15 / 20 / 25 / 30 / 35 / 40 / 42.5 CP(135) rope fixation be thread increased temperature range low 40...+85 C corrosion protection SX135 CP(135) CP(135) CP(135), GENERAL ACCESSES UR2 Def lection pulley SV1XXXX rope extension (150...4995 mm) MGG1 Magnetic clamp SV2XXXX rope extension (5000...19995 mm) SV3XXXX rope extension (20000...40000 mm) Subject to change without prior notice. WayCon Positionsmesstechnik GmbH email: info@waycon.de internet: www.waycon.de Head ffice Mehlbeerenstr. 4 82024 Taufkirchen Tel. +49 (0)89 67 97 130 Fax +49 (0)89 67 97 13250 ffice Köln Auf der Pehle 1 50321 Brühl Tel. +49 (0)2232 56 79 44 Fax +49 (0)2232 56 79 45