Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

Similar documents
MSA AUER SSR 90 [K60]

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

Combination Breathing Apparatus

[MSA The Safety Company] TURBO-FLO. Blowers. Replacement Parts. Accessories. Masks. Exploded Diagrams. safetyscope. Product Portfolio for FABA

Training. Testor Training Manual

Training. tm PA90 Series - Lung Demand Valve

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 15 HI-SR 200 USA. Operating instruction APR SR 200 full face mask

Operating Manual. PremAire Combination. Self-Contained Breathing Apparatus for Escape. Order No /01. MSAsafety.com

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

MMR Air Mask With. with Quick-Connect Hose

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Spiromatic Face Mask and breathing valve User manual

SOTR Special Operations Tactical Respirator

Product Information News

Declaration of Conformity as per Directive 97/23/EC

Ultra Elite-H Mask Negative Pressure

Operating Manual. PremAire Escape. Self-Contained Compressed Air Breathing Apparatus for Escape. Order No. D /00. MSAsafety.

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

DM-RCWH (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Wheel Set. WH-RX31 SM-AX x12 SM-AX x12

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

RG1200 Service and Repair Manual

MAINTENANCE PROCEDURE FOR X 650

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

H4802, H4802-1, H , and Pole Tampers

BMR Low/High Pressure USERS MAINTENANCE INSTRUCTIONS

Instruction manual Divator MKII Face mask

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Course Firefighter I. Unit II Safety and Orientation

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

1.0 - OPENING AND CLOSING THE DOOR

Santa Fe Cycles Assembly Guide Introduction

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Shifting Lever. RAPIDFIRE Plus 11-speed

Phalanx Alpha Phalanx Beta and Ultra Elite

RHPS Series PRV 2 all types of connections User Manual

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Owner s Guide. ElevateSUP.com

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, Operation, and Maintenance Manual

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

OPERATING INSTRUCTIONS

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Underwater Housing for Canon EOS M

DM-WH (English) Dealer's Manual. MTB Wheel Set. Non-Series WH-MT68 WH-MT66 WH-MT35 WH-MT15

S.E.A. Full Face Mask

Pfeiffer. Operating, assembly and maintenance instructions for discontinuous sampling valve Series 27i. 1. Design, operation and dimensions

Model VR6 System. Installation, Operation & Maintenance

Dive Rescue International Terms & Conditions

DelVal Flow Controls Private limited

Vortex Tube Respirator

DM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700

Installation & Operation Manual Proven Quality since 1892

SERVICE MANUAL LEGEND FIRST STAGE

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

LIQUIP DRYBREAK COUPLER. LYNX Series MAINTENANCE INSTRUCTIONS

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

DIVE RESCUE INTERNATIONAL, INC. Divator MKII Parts Price List

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PAPR Flow Tester. instructions. part no WARNING

AR STYLE FIREARMS OWNER'S MANUAL: OPERATION, HANDLING, DISASSEMBLY / REASSEMBLY & SAFETY INSTRUCTIONS

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

AirXpress One. User Manual. Self-contained Open-circuit Compressed Air apparatus. P/N: Rev.2

HYDRAULIC MOBILE LIFTING TABLE

Maintenance manual. Flight helmet LA100 PP

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Invacare Twilight II Nasal Mask

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Constant Pressure Crude Oil Container Model CPCCP

RHPS Series PRV 6 User Manual

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01

Shifting Lever. Dealer's Manual. RAPIDFIRE Plus SL-M2000 SL-M3010 SL-M4010. Thumb Shifter SL-TZ500. ROAD MTB Trekking. City Touring/ Comfort Bike

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Front Chainwheel. Dealer's Manual MTB. Bottom bracket. ROAD MTB Trekking. City Touring/ Comfort Bike XTR FC-M9000 FC-M9020 SM-BB93 SM-BB94-41A

DM-MBRD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur SLX RD-M7000 DEORE RD-M6000

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Hydraulic Punch Drivers

Type BBS-03, BBS-05, BBS-06, BBS-25

Operating instructions - Translation of the original -

12S 1st Stage. -Maintenance Procedure-

Air Mask Low/High Pressure

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

DM-MARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike REAR DERAILLEUR XTR RD-M9100 RD-M9120

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Transcription:

Operating Manual 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask AirElite - Full Face Masks Order No.: 10065505/05

MSA AUER GmbH D-12059 Berlin Thiemannstraße 1 Germany MSA AUER GmbH. All rights reserved

MSA SAFETY REGULATIONS Contents 1. Safety Regulations... 4 1.1. Correct Use... 4 1.2. Liability Information... 4 2. Description... 5 3. Use... 8 3.1. Putting on the Mask... 8 3.2. Testing for Tight Fit... 10 3.3. Removing the Mask... 10 4. Cleaning and Disinfection... 11 4.1. Cleaning/Disinfection with a Washing Machine... 11 4.2. Cleaning/Disinfection with an Ultrasonic Cleaner... 12 4.3. Cleaning by Hand... 12 4.4. Disinfection by Hand... 12 5. Maintenance... 13 5.1. Replacement of the Speech Diaphragm... 13 5.2. Replacement of the Mask Lens... 15 5.3. Replacing the Lens Wiper... 16 5.4. Leak Test... 16 6. Testing Intervals... 17 7. Safekeeping and Storage... 17 8. Ordering Information... 18 8.1. 3S-R AirElite Full Face Mask... 18 8.2. Advantage AirElite Full Face Mask... 19 8.3. Advantage AirElite 4000 Full Face Mask... 20 3S-R AirElite / Advantage AirElite/ Advantage 4000 AirElite Full Face Masks 3

SAFETY REGULATIONS MSA 1. Safety Regulations 1.1. Correct Use The 3S-R AirElite, Advantage AirElite and Advantage 4000 AirElite full face masks act as a face piece (EN 136 CL3) for the MSA AirElite respiratory protection device. They are not themselves complete respiratory protection devices but rather the parts for connecting the device to the user's respiratory tracts. It is imperative that this operating manual be read and observed when using the full face masks. In particular, the safety instructions, as well as the information for the use and operation of the apparatus, must be carefully read and observed. Furthermore, the national regulations applicable in the user's country must be taken into account for a safe use. Alternative use, or use outside this specification will be considered as noncompliance. This also applies especially to unauthorised alterations to the apparatus and to commissioning work that has not been carried out by MSA or authorised persons. Danger! This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the function of the device and thereby seriously compromise the user s life. Before use the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used. 1.2. Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims, warranties also as guarantees made by MSA with respect to the product are voided, if it is not used, serviced or maintained in accordance with the instructions in this manual. 4 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA DESCRIPTION 2. Description The inhalation air flows from the full face mask connection piece directly to the nose cup of the mask. The exhalation air follows the same route however in the opposite direction. This does not flush the eye area. Any misting of the lens is remedied by using the lens wiper. 1 2 3 4 7 6 5 Fig. 1 Overview 3S-R AirElite 1 Lens Wiper 5 Mask Lens 2 Head straps 6 Cap with speech diaphragm 3 Buckles 7 Connection piece 4 Harness 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 5

DESCRIPTION MSA 1 2 6 3 5 4 Fig. 2 Overview Advantage AirElite 1 Lens Wiper 4 Buckles 2 Head straps 5 Connection piece 3 Mask Lens 6 Cap with speech diaphragm 6 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA DESCRIPTION 1 2 3 6 5 4 Fig. 3 Overview Advantage 4000 AirElite 1 Lens Wiper 4 Buckles 2 Head straps 5 Connection piece 3 Mask Lens 6 Cap with speech diaphragm 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 7

USE MSA 3. Use The 3S-R mask is either carried using the harness in front of the chest or in the 3S mask container. In order to protect the inside of the 3S-R mask from dirt, the harness hook is engaged in the front buckle when the mask is held in front of the chest. The Advantage masks must always be transported in a mask container. Before using, soak the lens wiper cover of all masks with some drops of the MSA anti-misting agent to avoid scratching the lens. 3.1. Putting on the Mask Attention! The top of the mask seal must lie directly on the user's forehead. Hair should not be between the mask's seal and the user's skin. The mask could otherwise leak. This danger also exists for mask wearers with beards in the sealing area. 3S-R AirElite Mask (1) Pull the head harness apart with both hands. (2) First position your chin in the chin rest. (3) Pull the head straps over your head. Whilst doing so, ensure that the harness is sitting correctly. (4) Tighten the straps in order as shown firmly and evenly. When tightening the head straps ensure that the correct sequence is followed ( Figure Pos. 1-3). 8 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA USE Advantage AirElite Mask / Advantage 4000 AirElite Mask (1) Grasp the head harness with one hand by the eyelet of the head plate (2) Place the chin into the chin stop, then pull the harness over the head until the entire head plate lies against the head. (3) After the head harness is in position, make sure it lies flat against the head. (4) Tighten both straps (position 1) evenly and firmly. (5) Tighten the straps on top (position 2) to fix the mask in an accurate and sealing position. If necessary, repeat the procedure. 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 9

USE MSA 3.2. Testing for Tight Fit In order to check that the fit is tight, a leak test must be carried out before each use (Figures: 3S-R AirElite Mask as an example). (1) Seal the mask connection piece with the palm of your hand (hand ball test). (2) Test the tightness by inhaling and exhaling. Whilst doing so when inhaling there must be negative pressure, no inflowing air should be noticeable and when exhaling there must be overpressure, no breathable air should escape over the sealing edge. If necessary retighten the straps. If the leak test fails the mask must not be used. 3.3. Removing the Mask (1) Loosen the head harness, press the buckles forwards using your thumbs. (2) Grip the mask by the connection piece and pull off backwards over your head. 10 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA CLEANING AND DISINFECTION 4. Cleaning and Disinfection The cleaning and disinfection of the full face masks 3S-R, Advantage AirElite and Advantage 4000 AirElite is performed in accordance with the cleaning intervals Section 6. There are three possible kinds of cleaning: Using a washing machine Using an ultrasonic cleaner Cleaning by hand. Attention! Do not use cleaning products containing hydrocarbons or solvents [e.g. nitro-thinner]. Cleaned parts must not be dried in radiant heat [sun, radiators]. When using a drying cabinet, the temperature must not exceed +60 C. Perform a tightness test after every cleaning, disinfection and maintenance or after every exchange of parts. There are no valves inside the mask. For cleaning and disinfection it is not necessary to unbutton inner mask. (1) Clean mask using lukewarm water and mild cleaning agent (e.g. EW 80) and thoroughly rinse in running water. (2) If necessary, disinfect the mask after cleaning. (3) Dry mask. (4) Carry out leak test ( Section 5.4). 4.1. Cleaning/Disinfection with a Washing Machine Please follow the MSA washing agent s user instructions. If in any doubt, ask your local MSA contact person. (1) After cleaning check the two screws for the lens ring. Retighten the screws hand-tight if necessary. 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 11

CLEANING AND DISINFECTION MSA 4.2. Cleaning/Disinfection with an Ultrasonic Cleaner When cleaning/disinfecting with an ultrasonic cleaner please follow the MSA cleaning agent s user instructions. If in any doubt, ask your local MSA contact person. 4.3. Cleaning by Hand (1) Remove inhalation and exhalation valve discs. (2) Unbutton the nose cup. (3) Unscrew the speaking diaphragm with the special tool. (4) Clean mask using lukewarm water and mild cleaning agent EW 80 and thoroughly rinse in running water. (5) Disinfect the mask after cleaning. Removed components must be separately cleaned and disinfected. (6) Dry mask and components and reassemble mask in reverse order. (7) Carry out leak test [ Section 5.4]. 4.4. Disinfection by Hand Clean the mask before disinfecting. Use a disinfectant according to the MSA user instructions. If in any doubt, ask your local MSA contact person. (1) Disassemble and clean the mask [ Section 4.3]. (2) Disinfect the mask using recommended disinfectant. Please observe the user instruction for the disinfectant. (3) Thoroughly rinse mask in running water. (4) Dry mask and components and reassemble mask in reverse order. (5) Carry out leak test [ Section 5.4]. 12 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA MAINTENANCE 5. Maintenance A function and leak test of the mask, as well as the replacement of parts, form part of maintenance (maintenance intervals Section 6). Only MSA spare parts are permitted for repairs. Attention! After all cleaning, disinfection, maintenance or replacement of parts, a leak test must be carried out. 5.1. Replacement of the Speech Diaphragm 3S-R AirElite Mask 2 1 3 4 Fig. 4 3S-R AirElite Disassembly 1 Cap 3 Speech diaphragm 2 Ring nut 4 Inner mask (1) In order to replace the speech diaphragm, unbutton the inner mask and unscrew the ring nut with the spanner D2055038. (2) Remove the old speech diaphragm and fit the new speech diaphragm with the gasket to the connection piece. 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 13

MAINTENANCE MSA Advantage /Advantage 4000 AirElite Mask 1 4 2 5 3 6 Fig. 5 Advantage AirElite/ Disassembly 1 Plug connector 4 Connection piece 2 Gasket 5 Circlip 3 Cap 6 Inner mask (1) Using spanner D2056738 unscrew plug connector and remove gasket. (2) Press the cap in the area of the adapter and loosen from the mask. (3) Push the circlip apart at the top ends with your thumbs until the fixing has lifted, push the circlip downwards and remove. (4) Push the inner mask with the connection piece inwards and remove. Then remove the inner mask completely from the connection piece. (5) Reassemble mask in reverse order as follows. Reinsert the connection piece in the inner mask so that both openings of the inner mask have a tight fit in the connection piece and the flange is seated neatly. Fit the inner mask again by pushing the connection piece through the lens opening. Fit the circlip and place the cap on the connection piece. Insert the gasket and screw on the plug connector with a torque of 250 Ncm (use spanner D2056738 in combination with a commercially torque wrench). (7) Carry out leak test ( Section 5.4). 14 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA MAINTENANCE When replacing the speech diaphragm, the entire connection piece incl. cap, speech diaphragm, circlip and O-ring must be replaced: (1) Disassemble the mask as described, ensuring that the inner mask is fully removed from the connection piece. (2) Fit the new connection piece to the inner mask and assemble the mask as already described. 5.2. Replacement of the Mask Lens 3S-R AirElite Mask Removing mask lens (1) Loosen screws on the lens frame. (2) Remove both halves of the lens frame. (3) Remove lens. (4) Disassemble lens wiper ( Section 5.3). Fitting new lens Ensure before fitting the new lens, that the mask body groove is completely clean. (1) Fit lens wiper to the new mask lens ( Section 5.3). (2) Fit the new mask lens in reverse order from the disassembly. After assembly, the markings in the centre must be in proportion at the top and the bottom on the mask body, lens and lens frame halves for all masks. The lens identification must point towards the connection piece. 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 15

MAINTENANCE MSA Advantage AirElite Mask Removing mask lens (1) Disassemble the mask as described in Section 5, ensuring that the inner mask is removed with the connection piece. (2) Loosen screws on the lens frame. (3) Remove both halves of the lens frame. (4) Remove lens. (5) Remove lens wiper ( Section 5.3). Fitting new lens Ensure before fitting the new lens, that the mask body groove is completely clean. (1) Fit lens wiper to the new mask lens ( Section 5.3). (2) Fit the new mask lens in reverse order from the disassembly. 5.3. Replacing the Lens Wiper (1) Unscrew wiper screw. (2) Remove washer and lens wiper from the shaft. (3) Before assembly of the new wiper remove the shaft with the O-ring and lightly coat with special grease. BARRIERTA 1 EL is recommended ( ordering information). (4) Fit the O-ring again with the shaft. (5) Place the lens wiper and washer on the shaft again and secure with the wiper screw. Secure the wiper screw during the assembly with unlockable screw sealing coat LOCTITE 242 ( ordering information). 5.4. Leak Test The testing of the full face masks for tightness is performed using the MSA mask leak testing instrument in combination with the MSA mask leak testing adapter with plug connector 10074842 in accordance with the relevant operating manual. The full face masks are considered tight when, with overpressure and underpressure respectively in the mask of 10 mbar, the pressure change is not more than 1 mbar within a minute. 16 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA TESTING INTERVALS 6. Testing Intervals The applicable regulations in each area of use must be observed (e.g. shorter intervals where there are higher risks). If necessary, the work must be performed at earlier intervals other than those in the table. Instruments Work to be carried out Before Use Maximum Intervals After Use 1) 6- Monthly Two Years Six Years Full face mask Cleaning and Disinfection X Visual, Functional and Tightness Check X X 2) Application of anti-misting agent X X Replacement of the Speech Diaphragm X Check by Apparatus user X 1) Face pieces which are used on a regular basis should be cleaned as often as necessary. They should be cleaned as soon as possible after each use. Disinfection must be carried out, at the latest, before handing over the device to another wearer. 2) Only random tests in the case of airtight packed devices. 7. Safekeeping and Storage For the safekeeping of the full face mask the mask container should be used. Storage must be in clean and dry conditions in a normal climate, i.e. cool, dry and free from contaminants, protected from light and heat radiation. Attention! In order to avoid deformation of the wiper place the lens wiper into the centre position. Attention! In order to avoid damage to or the deformation of the full face masks no additional objects shall be kept in the mask container. Observe the instructions on the lid of the mask container. 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 17

ORDERING INFORMATION MSA 8. Ordering Information 8.1. 3S-R AirElite Full Face Mask Description Part No. 3S-R AirElite Full Face Mask 10065153 Spare Parts Lens Lens wiper lever, complete D2055197 D2055747 Lens wiper 10071734 Speech diaphragm (2 per package) Lens frame (1 package) Accessories Spanner (for assembly of the speech diaphragm) 3S mask container Testing Instrument MSA mask leak testing instrument Mask leak testing adapter with connector (needed for mask leak testing instrument) Disinfectant D2055708 D2055746 D2055038 D2055709 D6063705 10074842 MSA anti-misting agent klar pilot Super Plus 10032164 Recommended Special Agents Cleaner EW 80, by Tremonia Chemie, Dortmund Special lubricant BARRIERTA, by Klüber Lubrication München KG, Geisenhausenerstraße 7, 81379 Munich Screw sealing agent LOCTITE 242, by LOCTITE Deutschland GmbH, Arabellastr. 17, 81925 Munich 18 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA ORDERING INFORMATION 8.2. Advantage AirElite Full Face Mask Description Part No. Advantage AirElite Full Face Mask 10065154 Spare Parts Lens 10068944 Lens frame (1 package) 10068943 Lens wiper lever, complete D2055747 Lens wiper 10071734 Harness (replacement) 10118775 Connection piece complete (incl. cap, speech diaphragm, circlip 10068941 and O-ring) Accessories Spanner for plug connector D2056738 Mask container 10026179 Tester MSA mask leak testing instrument D6063705 Mask leak testing adapter with connector 10074842 (needed for mask leak testing instrument) Cleaner and Disinfectant MSA anti-misting agent klar pilot Super Plus 10032164 Recommended Special Agents Cleaner EW 80, by Tremonia Chemie, Dortmund Special lubricant BARRIERTA, by Klüber Lubrication München KG, Geisenhausenerstraße 7, 81379 Munich Screw sealing agent LOCTITE 242, by LOCTITE Deutschland GmbH, Arabellastr. 17, 81925 Munich 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 19

ORDERING INFORMATION MSA 8.3. Advantage AirElite 4000 Full Face Mask Description Part No. Advantage 4000 AirElite Full Face Mask 10118774 Spare Parts Harness (replacement) 10118775 Lens 10068944 Lens frame (replacement) 10118776 Lens wiper lever, complete D2055747 Lens wiper 10071734 Connection piece complete (incl. cap, speech diaphragm, circlip 10068941 and O-ring) Accessories Spanner for plug connector D2056738 Mask container 10026179 Tester MSA mask leak testing instrument D6063705 Mask leak testing adapter with connector 10074842 (needed for mask leak testing instrument) Cleaner and Disinfectant MSA anti-misting agent klar pilot Super Plus 10032164 Recommended Special Agents Cleaner EW 80, by Tremonia Chemie, Dortmund Special lubricant BARRIERTA, by Klüber Lubrication München KG, Geisenhausenerstraße 7, 81379 Munich Screw sealing agent LOCTITE 242, by LOCTITE Deutschland GmbH, Arabellastr. 17, 81925 Munich 20 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks

MSA ORDERING INFORMATION 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks 21

ORDERING INFORMATION MSA Space holder for back page 22 3S-R AirElite / Advantage AirElite / Advantage 4000 AirElite Full Face Masks