EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING.

Similar documents
EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. Report Holder:

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS.

EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS

EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. Report Holder:

Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications 1

Effective Date: July 2016 Void After: July Product: ABS-DWV Pipe and Fittings File No. 9266

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS

PVC DWV FITTINGS PVC-0312 MARCH 2012 SUPERCEDES PVC-0112 ASTM D2665

Effective Date: April 2018 Void After: April 2019

Effective Date: May 2017 Void After: May Product: Press and Nail Connections File No. M-8332

ABS DWV FITTINGS BOW INDUSTRIAL CORPORATION

EVALUATION SUBJECT: FIBERGLASS ONE-PIECE SWIMMING POOL SHELLS DIVISION: SPECIAL CONSTRUCTION SECTION: BELOW-GRADE SWIMMING POOLS

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

Effective Date: December 2017 Void After: December 2018

PVC Fittings Price Sheet. Description 1 1/4 1 1/2 8 COUPLING DWV. Description. Description. Description. Description. Description 1 1/2 TRAP

Effective Date: January 2018 Void After: January Product: Fill Valves (Anti-Siphon) File No. 3733

Effective Date: February 2018 Void After: February Product: Bathtubs (Plastic) File No. 3638

Effective Date: not available -Rev. 12/1/2017- Void After: Product: Water Closets with Dual Flush Feature File No. 5645

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

-Proline Polypropylene Single Wall Piping

Suction fittings for use in swimming pools, wading pools, spas, hot tubs, and other aquatic facilities.

Multi-Flow Product Catalog

1805 Series Relief Valves

BS Series Basket Strainer

Submittal Package. Viega MegaPress Fitting System. Chilled Water. Hydronic Heating. Fire Protection. Low Pressure Steam. Compressed Air (no oil)

Brass Tubular. P-Traps. Item # Description Qty

June For do-it-yourselfers as well as pros, Genova is the only way to go in home plumbing and vinyl building materials.

T208VR Series Tank Blanketing Vacuum Regulator

PIP PNE00012 Piping Examination and Leak Test Guide

Code Compliance Research Report CCRR-0145

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018

ABS-DWV Fittings / Raccords ABS DÉÉ

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Code Compliance Research Report CCRR-0145

MSC Guidelines for Sanitary & Sewage Systems

Y692VB Series Vacuum Breaker

WSC Performance Standard and Recommended Installation Procedures for Sanitary Water Well. Pitless Adapters, Pitless Units, And Well Caps

Supplement Catalog For. Marine/RV & Manufactured Housing

April For do-it-yourselfers as well as pros, Genova is the only way to go in home plumbing and vinyl building materials.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Catalog C-PF-0213 A h e A d O F t h e F l O w P l a s t i c F i t t i n g s

Effective Date: October 2017 Void After: October Product: Ceramic Plumbing Fixtures File No. 2467

210 & 220 series gas pressure regulators for industrial applications

HYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet

EPOXY FITTINGS DIMENSIONS

Design DSA Steam-Atomized Desuperheater

S300 Series. Valve Link. Features. Fisher Controls

Price Schedule # Effective: MAy 5, 2014

PIPE, VALVE & FITTING

Installation, Operation, and Maintenance Manual

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Fisher DSA Steam-Atomized Desuperheater

APPRENTICESHIP PROGRAM

Installation, Operation and Maintenance Manual

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

R-3501-E2 R-3501-H4. R-3501-HL Mountable Curb Frame, Grate

Buttweld Fittings ANSI B16.9, ANSI B16.28, MSS-SP-43, MSS-SP-95, MSS-SP-97

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

1805 Series Relief Valves

CLEANING, INSPECTION, AND TESTING OF SEWERS

GENERAL NOTES FOR SWIMMING POOLS AND SPAS

Type 1190 Low-Pressure Gas Blanketing Regulator

TITAN FLOW CONTROL, INC.

SPIRAL PIPE - OVAL SINGLE WALL

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.

Flue Gas Venting Systems

MSC Guidelines for Independent Fuel Tanks

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

IAPMO IS PUBLIC REVIEW DRAFT Thrust Blocking for Rubber Gasketed and Solvent Cement Joints

Compressed Gases and Cryogens

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings

2016/2017 Product Catalog

TN-20/2007. Special Precautions for Fusing Saddle Fittings to Live PE Fuel Gas Mains Pressurized on the Basis of a 0.

Eaton Filtration, LLC

CheerSpirit.com Plug-In Pack 3 Kneeling

Fisher DVI Desuperheater Venturi Inline

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (ELEVENTH REVISION)

THE KEENEY MANUFACTURING COMPANY

Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: Installed Date:

Submittal / Substitution Request

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

PAGE (Rev. A - 06/17)

SR100 Series Service Regulators. Technical Bulletin

22. Specialty Valves.

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

ob or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: Installed Date: 1 1/2" 4" 1/8 Bend PVDF 1 1/2" 4" Caps PVDF

A112 STANDARDS STATUS REPORT

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Transcription:

ICC-ES Report PMG-1407 Reissued 10/2017 This report is subject to renewal 10/2018 EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 13 16 SANITARY WASTE AND VENT PIPING Report Holder: JC CAST IRON CORP PO BOX 3044 SOUTH EL MONTE, CA 91733

ICC-ES PMG Product Certificate PMG-1407 Effective Date: October 2017 This listing is subject to re-examination in one year. www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council CSI: DIVISION: 22 00 00 PLUMBING Section: 22 13 16 Sanitary Waste and Vent Piping Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier s stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier s quality system. Product: Listee: Cast Iron Soil Pipe and Fittings JC Cast Iron Corp PO Box 3044 South El Monte, California 91733 www.jccastiron.com Compliance with the following codes: 2018, 2015, 2012 and 2009 International Plumbing Code (IPC) 2018, 2015, 2012 and 2009 International Residential Code (IRC) 2015, 2012 and 2009 Uniform Plumbing Code (UPC)* *Copyrighted publication of the International Association of Plumbing and Mechanical Officials Compliance with the following standards: Identification: CISPI 301-2012, (excluding Annex A) Standard Specification for Hubless Cast Iron Soil Pipe and Fittings For Sanitary and Storm Drain, Waste, and Vent Piping Applications ASTM A888-2015, (excluding Annex A1) Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications Each length of pipe and each fitting shall be plainly marked with the country of origin, the manufacturer s name or the manufacturer s registered trademark by which the manufacturer can be readily identified after installation and any appropriate collective mark (optional). The marking shall be adequate identification of the manufacturer of the pipe and fittings if it readily identifies the manufacturer to the end user of the product. Markings shall be cast on fittings. Pipe markings: The pipe shall be marked continuously on the barrel with a minimum of 0.75 inch (19mm) lettering starting within 3 inches of each end of the pipe. Each pipe shall be marked with the date of manufacture and the ICC-ES PMG listing mark. The marking shall be stenciled on the pipe or otherwise applied so as to be clear and legible. Fitting markings: The marking shall be cast with raised letters that are not to be located within the Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

PMG-1407 Most Widely Accepted and Trusted Page 2 of 4 Installation: Models: W dimension. Cast markings shall be raised from the wall of the fitting unless otherwise noted. Fittings or fittings packaging shall be marked with ICC-ES PMG listing mark. The JC Cast Iron Corp pipe and fittings are to be installed in accordance with the manufacturer's instructions and the applicable code JC Cast Iron Corp. pipe and fittings are used in Sanitary Waste Systems and Storm Drain Systems in accordance with the applicable code. PIPE: Hubless Cast Iron Pipe in 5 and 10 Feet Nominal Lengths 0156 Pipe 1-1/2" 0158 Pipe 2 0160 Pipe 3 0162 Pipe 4 0168 Pipe 6 0170 Pipe 8 0172 Pipe 10 FITTINGS: 0188 ¼ Bend 1-1/2" 0190 ¼ Bend 2 0192 ¼ Bend 3 0194 ¼ Bend 4 0198 ¼ Bend 6 0200 ¼ Bend 8 0280 Low Heel ¼ Bend 3" x 2" 0282 Low Heel ¼ Bend 4" x 2 0462 Short Sweep ¼ Bend 2 0464 Short Sweep ¼ Bend 3 0468 Short Sweep ¼ Bend 4 0472 Short Sweep 6 0474 Short Sweep ¼ Bend 8 0492 Long Sweep ¼ Bend 1-1/2" 0494 Long Sweep ¼ Bend 2 0496 Long Sweep ¼ Bend 3 0498 Long Sweep ¼ Bend 4 0536 1/5 Bend 2 0538 1/5 Bend 3 0540 1/5 Bend 4 0570 1/6 Bend 2 0572 1/6 Bend 3 0574 1/6 Bend 4 0604 1/8 Bend 1-1/2" 0606 1/8 Bend 2 0608 1/8 Bend 3 0610 1/8 Bend 4 0614 1/8 Bend 6 0616 1/8 Bend 8

PMG-1407 Most Widely Accepted and Trusted Page 3 of 4 0676 1/16 Bend 1-1/2" 0678 1/16 Bend 2 0680 1/16 Bend 3 0682 1/16 Bend 4 0686 1/16 Bend 6" 0688 1/16 Bend 8 0806 Sanitary Tee 1-1/2" 0808 Sanitary Tee 2 x 1-1/2" 0810 Sanitary Tee 2 0814 Sanitary Tee 3 x 2 0816 Sanitary Tee 3 0818 Sanitary Tee 4 x 2 0820 Sanitary Tee 4 x 3 0822 Sanitary Tee 4 0834 Sanitary Tee 6 x 4" 0836 Sanitary Tee 6 1210 Sanitary Tapped Tee 1-1/2" 1214 Sanitary Tapped Tee 2 x 1-1/2" 1216 Sanitary Tapped Tee 2 x 2 1220 Sanitary Tapped Tee 3 x 1-1/2" 1222 Sanitary Tapped Tee 3 x 2 1226 Sanitary Tapped Tee 4 x 1-1/2" 1228 Sanitary Tapped Tee 4 x 2 1312 Wye 1-1/2" 1314 Wye 2 1316 Wye 3 x 2 1318 Wye 3 1320 Wye 4 x 2 1322 Wye 4 x 3" 1324 Wye 4 1338 Wye 6 x 4 1342 Wye 6 1348 Wye 8 x 4 1352 Wye 8 x 6 1538 Double Wye 2 1540 Double Wye 3 x 2 1542 Double Wye 3 1544 Double Wye 4 x 2 1546 Double Wye 4 x 3 1646 Wye Branch Upright 2 1648 Wye Branch Upright 3 x 2 1650 Wye Branch Upright 3 1694 Combination Wye 1/8 Bend 1-1/2" 1696 Combination Wye 1/8 Bend 2 x 1-1/2" 1698 Combination Wye 1/8 Bend 2 1700 Combination Wye 1/8 Bend 3 x 2 1702 Combination Wye 1/8 Bend 3 1704 Combination Wye 1/8 Bend 4 x 2 1706 Combination Wye 1/8 Bend 4 x 3" 1708 Combination Wye 1/8 Bend 4 1722 Combination Wye 1/8 Bend 6 x 4 1726 Combination Wye 1/8 Bend 6 1728 Combination Wye 1/8 Bend 8 x 4 1732 Combination Wye 1/8 Bend 8 x 6 1734 Combination Wye 1/8 Bend 8 1854 Sanitary Cross Tee 3 x 2 1856 Sanitary Cross Tee 3

PMG-1407 Most Widely Accepted and Trusted Page 4 of 4 1860 Sanitary Cross Tee 4 x 3 1862 Sanitary Cross 4 2046 Test Tee 2 2048 Test Tee 3 2050 Test Tee 4 2138 Increaser/Reducer 2 x 1-1/2" 2140 Increaser/Reducer 3 x 2 2142 Increaser/Reducer 4 x 2 2144 Increaser/Reducer 4 x 3 2154 Increaser/Reducer 6 x 3 2156 Increaser/Reducer 6 x 4 2242 Tapped Adapter 2 x 1-1/2" 2244 Tapped Adapter 2 x 2 2250 Tapped Adapter 3 x 2 2482 Blind Plug 2 2484 Blind Plug 3 2486 Blind Plug 4 2490 Blind Plug 6 2506 P-Trap 1-1/2" 2508 P-Trap 2 2510 P-Trap 3 2512 P-Trap 4 2586 P-Trap w/ Tapped Inlet 2 x 1-1/2" 2832 Closet Bend 3 x 4 x 6 x 12 2840 Closet Bend 3 x 4 x 6 x 15 2904 Closet Bend 4 x 4 x 6 x 12 2908 Closet Bend 4 x 4 x 6 x 15 2912 Closet Bend 4 x 4 x 6 x 18 8003 Closet Flange 4 x 2 9480 Closet Flange 4 x 2 9482 Closet Flange 4 x 4 8002 Figure 1A Fitting 2 x 2 x 1-1/2" x 1-1/2" 8052 Figure 5 Fitting 2 8054 Figure 5 Fitting 3 x 2 8056 Figure 5 Fitting 3 8058 Figure 5 Fitting 4 x 2 8062 Figure 5 Fitting 4 8088 Figure 5 Extended Fitting 3 x 2 8442 Two-Way Cleanout 3 x 3 x 4 8446 Two-Way Cleanout 4 x 4 x 4 8530 P-Trap w/ ½ Tap Primer 2 8532 P-Trap w/ ½ Tap Primer 3 8564 Iron Body Cleanout, Tapped 3 8566 Iron Body Cleanout, Tapped 4 Conditions of Listing: 1. JC Cast Iron Corp pipe and fittings must be installed in accordance with this listing, the applicable code and the manufacturer s published installation instructions. The instructions within this listing must govern if there are any conflicts between the manufacturer s published instructions and this listing. 2. The models recognized in this listing are distributed JC Cast Iron Corp in El Monte, California under a quality control program with annual surveillance inspections by ICC-ES.